首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Here we describe the application of a recently developed high-resolution microcantilever biosensor resonating at the air-liquid interface for the continuous detection of antigen-antibody and enzyme-substrate interactions. The cantilever at the air-liquid interface demonstrated 50% higher quality factor and a 5.7-fold increase in signal-to-noise-ratio (SNR) compared with one immersed in the purified water. First, a label-free detection of a low molecular weight protein (insulin, 5.8 kDa) in physiological concentration was demonstrated. The liquid facing side of the cantilever was functionalized by coating its surface with insulin antibodies, while the opposite side was exposed to air. The meniscus membrane at the micro-slit around the cantilever sustained the liquid in the microchannel. After optimizing the process of surface functionalization, the resonance frequency shift was successfully measured for insulin solutions of 0.4, 2.0, and 6.3 ng ml(-1). To demonstrate additional application of the device for monitoring enzymatic protein degradation, the liquid facing microcantilever surface was coated with human recombinant SOD1 (superoxide dismutase 1) and exposed to various concentrations of proteinase K solution, and the kinetics of the SOD1 digestion was continuously monitored. The results showed that it is a suitable tool for sensitive protein detection and analysis.  相似文献   

2.
Hwang KS  Lee JH  Park J  Yoon DS  Park JH  Kim TS 《Lab on a chip》2004,4(6):547-552
We report on a novel technique of resonant frequency shift measurement based on a nanomechanical cantilever with a PZT actuating layer for label-free detection of a prostate-specific antigen (PSA) in a liquid environment. The nanomechanical PZT thin film cantilever is composed of SiO(2)/Ta/Pt/PZT/Pt/SiO(2) on a SiN(x) supporting layer for simultaneous self-exciting and sensing; it was fabricated using a standard MEMS (micro electromechanical system) process. The specific binding characteristics of the PSA antigen to its antibody, which is immobilized with Calixcrown self-assembled monolayers (SAMs) on a gold surface deposited on a cantilever, are determined to a high sensitivity. For the bioassay in a liquid environment, a liquid test cell with a 20 microl volume reaction chamber has been fabricated, using a bonding technique between poly(dimethyl siloxane) (PDMS) bilayers. An observed trend of resonant frequency change with respect to time could be explained by the binding kinetics due to the Langmuir isotherm and diffusion and by the effects of a small volume reaction chamber. In the saturated regimes, the resonant frequency of the cantilever increased with increase of the PSA concentration in the reaction chamber, showing that the trend of the resonance frequency change was similar to that of the fluorescence results. The saturated resonance frequency shift of the cantilever was proportional to the PSA antigen concentration of analyte solution.  相似文献   

3.
A new method for studying the dynamics of a sessile drop by atomic force microscopy (AFM) is demonstrated. A hydrophobic microsphere (radius, r ~ 20-30 μm) is brought into contact with a small sessile water drop resting on a polytetrafluoroethylene (PTFE) surface. When the microsphere touches the liquid surface, the meniscus rises onto it because of capillary forces. Although the microsphere volume is 6 orders of magnitude smaller than the drop, it excites the normal resonance modes of the liquid interface. The sphere is pinned at the interface, whose small (<100 nm) oscillations are readily measured with AFM. Resonance oscillation frequencies were measured for drop volumes between 5 and 200 μL. The results for the two lowest normal modes are quantitatively consistent with continuum calculations for the natural frequency of hemispherical drops with no adjustable parameters. The method may enable sensitive measurements of volume, surface tension, and viscosity of small drops.  相似文献   

4.
We demonstrate a new sensitive biosensor for detection of vital fungal spores of Aspergillus niger. The biosensor is based on silicon microfabricated cantilever arrays operated in dynamic mode. The change in resonance frequency of the sensor is a function of mass binding to the cantilever surface. For specific A. niger spore immobilization on the cantilever, each cantilever was individually coated with anti-Aspergillus niger polyclonal antibodies. We demonstrate the detection of single A. niger spores and their subsequent growth on the functionalized cantilever surface by online measurements of resonance frequency shifts. The new biosensor operating in humid air allows quantitative and qualitative detection of A. niger spores as well as detection of vital, functional spores in situ within approximately 4 h. The detection limit of the sensor is 103 CFU mL-1. Mass sensitivity of the cantilever sensor is approximately 53 pg Hz-1.  相似文献   

5.
Extracting quantitative information from amplitude-modulation atomic force microscopy (AM-AFM) in viscous ionic liquids is difficult because existing theory requires knowledge of the cantilever natural frequency, which cannot be measured in the absence of a resonance peak. We present a new model that describes cantilever dynamics in an overdamped medium (Q < 0.5) and derive the theory necessary to extract the stiffness and damping in highly viscous liquids. The proposed methodology is used to measure the solvation layers of an ionic liquid at a gold electrode.  相似文献   

6.
The evaporation of water drops with radii approximately 20 microm was investigated experimentally by depositing them onto atomic force microscope (AFM) cantilevers and measuring the deflection versus time. Because of the surface tension of the liquid, the Laplace pressure inside the drop, and the change of interfacial stress at the solid-liquid interface, the cantilever is deflected by typically a few hundred nanometers. The experimental results are in accordance with an analytic theory developed. The evaporation process could be monitored with high accuracy even at the last stage of evaporation because (1) cantilever deflections can be measured with nanometer resolution and (2) the time resolution, given by the inverse of the resonance frequency of the cantilever of approximately 0.3 ms, is much faster than the typical evaporation time of 1 s. Experimental results indicate that evaporation of the last thin layer of water is significantly slower than the rest of the drop, which can be due to surface forces. This drop-on-cantilever system can also be used to analyze the drop impact dynamics on a surface and to determine the spring constant of cantilevers.  相似文献   

7.
Resonant microcantilevers have demonstrated that they can play an important role in the detection of chemical and biological agents. Molecular interactions with target species on the mechanical microtransducers surface generally induce a change of the beam's bending stiffness, resulting in a shift of the resonance frequency. In most biochemical sensor applications, cantilevers must operate in liquid, even though damping deteriorates the vibrational performances of the transducers. Here we focus on diamond-based microcantilevers since their transducing properties surpass those of other materials. In fact, among a wide range of remarkable features, diamond possesses exceptional mechanical properties enabling the fabrication of cantilever beams with higher resonant frequencies and Q-factors than when made from other conventional materials. Therefore, they appear as one of the top-ranked materials for designing cantilevers operating in liquid media. In this study, we evaluate the resonator sensitivity performances of our diamond microcantilevers using grafted carboxylated alkyl chains as a tool to investigate the subtle changes of surface stiffness as induced by electrostatic interactions. Here, caproic acid was immobilized on the hydrogen-terminated surface of resonant polycrystalline diamond cantilevers using a novel one-step grafting technique that could be also adapted to several other functionalizations. By varying the pH of the solution one could tune the -COO(-)/-COOH ratio of carboxylic acid moieties immobilized on the surface, thus enabling fine variations of the surface stress. We were able to probe the cantilevers resonance frequency evolution and correlate it with the ratio of -COO(-)/-COOH terminations on the functionalized diamond surface and consequently the evolution of the electrostatic potential over the cantilever surface. The approach successfully enabled one to probe variations in cantilevers bending stiffness from several tens to hundreds of millinewtons/meter, thus opening the way for diamond microcantilevers to direct sensing applications in liquids. The evolution of the diamond surface chemistry was also investigated using X-ray photoelectron spectroscopy.  相似文献   

8.
Sensors are crucial in many daily operations including security, environmental control, human diagnostics and patient monitoring. Screening and online monitoring require reliable and high-throughput sensing. We report on the demonstration of a high-throughput label-free sensor platform utilizing cantilever based sensors. These sensors have often been acclaimed to facilitate highly parallelized operation. Unfortunately, so far no concept has been presented which offers large datasets as well as easy liquid sample handling. We use optics and mechanics from a DVD player to handle liquid samples and to read-out cantilever deflection and resonant frequency. Also, surface roughness is measured. When combined with cantilever deflection the roughness is discovered to hold valuable additional information on specific and unspecific binding events. In a few minutes, 30 liquid samples can be analyzed in parallel, each by 24 cantilever-based sensors. The approach was used to detect the binding of streptavidin and antibodies.  相似文献   

9.
We report on a bistable MEMS device actuated by spin-crossover molecules. The device consists of a freestanding silicon microcantilever with an integrated piezoresistive detection system, which was coated with a 140 nm thick film of the [Fe(HB(tz)3)2] (tz=1,2,4-triazol-1-yl) molecular spin-crossover complex. Switching from the low-spin to the high-spin state of the ferrous ions at 338 K led to a reversible upward bending of the cantilever in agreement with the change in the lattice parameters of the complex. The strong mechanical coupling was also evidenced by the decrease of approximately 66 Hz in the resonance frequency in the high-spin state as well as by the drop in the quality factor around the spin transition.  相似文献   

10.
A composite self-excited millimeter-sized lead zirconate titanate (PZT) glass cantilever (2 mm x 1.8 mm; sensing area of 6 mm2) was fabricated for the detection of Escherichia coli (E. coli) O157:H7. The fundamental and second mode resonance in air was 10.95 +/- 0.05 kHz and 43.45 +/- 0.05 kHz, respectively. Affinity purified monoclonal antibody (anti-E. coli O157:H7) specific to the pathogen E. coli O157:H7 was immobilized at the cantilever glass tip, and then immersed in liquid containing the pathogen (70 to 7 x 10(7) cells/mL). The resonant frequency showed a reduction and reached a steady state shift of 0 +/- 5, 46 +/- 5, 260 +/- 5, and 1010 +/- 5 Hz corresponding to 0, 700, 7000, and 7 x 10(7) cells/mL. From the experiments conducted, the detection limit of the sensor was 700 cells/mL.  相似文献   

11.
Nanogram amounts of paraffin were coated onto a silicon cantilever, and the resonance frequency and deflection of the cantilever were measured as a function of temperature. Changes in the cantilever resonance frequency were used to determine the temperatures at which phase transitions between the rotator phases of tricosane, tetracosane, and pentacosane occurred. The phase transition measured using the cantilever was found to be more apparent than that obtained using conventional methods. The thermal hysteresis in the resonance frequency of a tetracosane-coated cantilever differed from that of the tricosane- and pentacosane-coated cantilevers, which was attributed to the even-odd effect on the crystal structures of paraffin. The even-odd effect was also observed in the temperature dependent deflection measurements. Further, the overshoot at the transition R(V) → crystal in the deflection measurement was observed and attributed to the steep increase in the modulus of paraffin during the transition.  相似文献   

12.
We report on a bistable MEMS device actuated by spin‐crossover molecules. The device consists of a freestanding silicon microcantilever with an integrated piezoresistive detection system, which was coated with a 140 nm thick film of the [Fe(HB(tz)3)2] (tz=1,2,4‐triazol‐1‐yl) molecular spin‐crossover complex. Switching from the low‐spin to the high‐spin state of the ferrous ions at 338 K led to a reversible upward bending of the cantilever in agreement with the change in the lattice parameters of the complex. The strong mechanical coupling was also evidenced by the decrease of approximately 66 Hz in the resonance frequency in the high‐spin state as well as by the drop in the quality factor around the spin transition.  相似文献   

13.
Differentiation between species of similar biological structure is of critical importance in biosensing applications. Here, we report specific detection of Bacillus anthracis (BA) spores from that of close relatives, such as B. thuringiensis (BT), B. cereus (BC), and B. subtilis (BS) by varying the flow speed of the sampling liquid over the surface of a piezoelectric microcantilever sensor (PEMS). Spore binding to the anti-BA spore IgG coated PEMS surface is determined by monitoring the resonance frequency change in the sensor's impedance vs. frequency spectrum. Flow increases the resonance frequency shift at lower flow rates until the impingement force from the flow overcomes the binding strength of the antigen and decreases the resonance frequency shift at higher flow rates. We showed that the change from increasing to decreasing resonance frequency shift occurred at a lower fluid flow speed for BT, BC, and BS spores than for BA spores. This trend reduces the cross reactivity ratio of BC, BS, and BT to the anti-BA spore IgG immobilized PEMS from around 0.4 at low flow velocities to less than 0.05 at 3.8 mm s(-1). This cross reactivity ratio of 0.05 was essentially negligible considering the experimental uncertainty. The use of the same flow that is used for detection to further distinguish the specific binding (BA to anti-BA spore antibody) from nonspecific binding (BT, BC, and BS to anti-BA spore antibody) is unique and has great potential in the detection of general biological species.  相似文献   

14.
This paper presents a liquid surface biosensor whose potential applications are analogue to the well-known quartz crystal microbalance. The technique involved is based on the resonance of meniscus capillary waves here excited at a functionalized air-water interface. The strategy proposed in this paper can be seen as a promising way to avoid as much as possible any transfer of Blodgett type. Meniscus capillary waves supplied by the electrodynamical vibration of a brimful cylinder filled with water are used as a way to characterize the surface aging of an air-water interface covered by a lipidic monolayer. An optical technique based on one-dimensional interferometry is developed to measure continuously the resonant behavior of the surface elevation at the center of the cell around the natural frequencies of the meniscus waves. The frequency dependence of the wave amplitude is investigated during the transient regime associated to the immobilization of DNA strands at the lipidic matrix. Resonant frequencies are found to be very sensitive to the chemical loading supported by the air-water interface. The technique is seen as a mean to discriminate between single- and double-stranded DNA.  相似文献   

15.
We have used a spectral analysis method to characterize changes in the local damping coefficient for an acoustically driven cantilever as it approaches a hard surface in liquid. We show a significant distance dependence of the damping coefficient (and associated quality factor) that must be accounted for to achieve successful theoretical reproduction of experimental tapping-mode force curves. We model the cantilever dynamics using a forced damped harmonic oscillator model and solve the equation of motion using the method of finite differences. Experiments in solutions of differing viscosities show that bulk viscous damping is not the source of the system dissipation, while simulations of the cantilever dynamics including adhesion hysteresis also eliminate this as the origin of the dissipation. We conclude that frictional dissipation that occurs with the intermittent contact is the likely source of dissipation in the system. Our results identify a semiquantitative means of interpreting tapping-mode force curves on nondeformable surfaces in liquid.  相似文献   

16.
A mass sensor innovative concept is presented here, based on a hollow plate Micro Electro Mechanical System (MEMS) resonator. This approach consists in running a solution through an embedded microchannel, while the plate resonator is actuated according to a Lamé-mode by electrostatic coupling in dry environment. The experimental results have shown a clear relationship between the measured shift of the resonance frequency and the sample solution density. Additionally, depending on the channel design and the solution properties, the quality factor (Q-factor) was noticed maintaining its level and even substantial improvement in particular cases. Resonators demonstrate resonance frequencies close to 78 MHz and Q-factor of a few thousands for liquid phase detection operating at ambient temperature and atmospheric pressure. Frequency fluctuations study revealed a 13 Hz instability level, equivalent to 1.5 fg in mass. Using a fully electronic readout configuration, a mass responsivity of ca. 850 fg kHz(-1) was monitored.  相似文献   

17.
We demonstrate the accurate nanoscale mapping of near-surface loss and storage moduli on a polystyrene-polypropylene blend with contact resonance force microscopy (CR-FM). These viscoelastic properties are extracted from spatially resolved maps of the contact resonance frequency and quality factor of the AFM cantilever. We consider two methods of data acquisition: (i) discrete stepping between mapping points and (ii) continuous scanning. For point mapping and low-speed scanning, the values of the relative loss and storage modulus are in good agreement with the time-temperature superposition of low-frequency dynamic mechanical analysis measurements to the high frequencies probed by CR-FM.  相似文献   

18.
Liquid coating of moving fiber at the nanoscale   总被引:1,自引:0,他引:1  
Using large scale molecular dynamics, we study the contact line motion of a liquid meniscus crossed by a moving nanofiber. Varying the amplitude of the liquid/solid interactions, we analyze the shape of the meniscus versus time for a range of velocities. The associated contact angles are estimated by fitting the profiles using the James equation. The corresponding flux lines describing the displacement of the liquid molecules inside the meniscus have also been measured. The analysis of the dynamic contact angle is in agreement with the molecular-kinetic theory and confirms the existence of an optimal speed for wetting.  相似文献   

19.
Capillary condensation at the nanoscale differs from condensation in the bulk phase, because it is a strong function of surface geometry and gas-surface interactions. Here, the effects of geometry on the thermodynamics of capillary condensation at the neck region between nanoparticles are investigated via a grand canonical Monte Carlo simulation using a two-dimensional lattice gas model. The microscopic details of the meniscus formation on various surface geometries are examined and compared with results of classical macromolecular theory, the Kelvin equation. We assume that the system is composed of a lattice gas and the surfaces of two particles are approximated by various shapes. The system is modeled on the basis of the molecular properties of the particle surface and lattice gas in our system corresponding to titania nanoparticles and tetraethoxy orthosilicate molecules, respectively. This system was chosen in order to reasonably emulate our previous experimental results for capillary condensation on nanoparticle surfaces. Qualitatively, our simulation results show that the specific geometry in the capillary zone, the surface-surface distance, and the saturation ratio are important for determining the onset and broadening of the liquid meniscus. The meniscus height increases continuously as the saturation ratio increases and the meniscus broadens faster above the saturation ratio of 0.90. The change of the radius of curvature of the particle surface affects the dimensions of the capillary zone, which drives more condensation in narrow zones and less condensation in wide zones. The increase of surface-surface distance results in the decrease of the meniscus height or even the disappearance of the meniscus entirely at lower saturation ratios. These effects are significant at the nanoscale and must be carefully considered in order to develop predictive relationships for meniscus height as a function of saturation conditions.  相似文献   

20.
We measured the interfacial tension and the density of air/n-hexane, n-decane, 1-perfluorohexane/1-hexyl-3-methyl-imidazolium hexafluorophosphate systems as a function of temperature. From the air/ionic liquid surface tension values, it was suggested that Coulombic interaction between imidazolium cations and counter anions are not so much different between the surface and bulk. The density values indicated that the decrease of surface tension by saturating organics was closely correlated to the mutual solubility between ionic liquid and organics. Interfacial tension at the oil/ionic liquid interfaces suggested that ionic liquid molecules were more ordered at the oil/ionic liquid interfaces compared to the air/ionic liquid interfaces, but the decrease of the entropy due to the interfacial orientation of ionic liquid was compensated by the increase of the entropy due to the contact of different chemical species. The initial spreading coefficients and the Hamaker constants indicated that all the oil phases spread at the air/ionic liquid interfaces spontaneously, and form the complete wetting films.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号