首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
邓洁丽  郭彩欣  鲁闻生  刘涛  江龙 《化学进展》2006,18(11):1397-1408
有序排列的联乙炔分子,在紫外光照射下发生聚合。聚联乙炔(PDA)线性骨架的离域π电子,在可见光区产生π-π* 跃迁,显示特有的蓝色。聚联乙炔囊泡表面的分子探针(受体)在遇到可识别的生物大分子(如DNA,抗体-抗原和细菌等)的配体时,可使其颜色从蓝色转变为红色,有时能产生荧光。这种囊泡将检测与显示集为一体,是一种典型的生物分子器件,近年来已被用于很多物质的测定,其中包括病毒、细菌、亲脂性酶、抗菌肽类、哺乳动物肽类、离子、抗体、蛋白质和寡核苷酸等。此外,聚合囊泡还可以与金结合形成空心金球,可以作为一种三维纳米金的载体,对DNA的固定、识别和分离具有极为诱人的应用前景。通过对各种影响因素的研究和检测条件的改进,聚联乙炔生物传感器的灵敏度和选择性还能进一步提高,具有广阔的应用前景。  相似文献   

2.
Luo Y  Yu F  Zare RN 《Lab on a chip》2008,8(5):694-700
We have designed and fabricated a polydimethylsiloxane (PDMS) microfluidic device containing an array of gold spots onto which antigens or antibodies of interest can be attached. We use surface plasmon resonance (SPR) imaging to monitor the antibody-antigen recognition and binding events. This combination offers two significant advantages: (1) the microfluidic device dramatically reduces reaction time and sample consumption; and (2) the SPR imaging yields real-time detection of the immunocomplex formation. Thus, an immunoreaction may be detected and quantitatively characterized in about 10 min. The sensitivity of this method is at the subnanomolar level. When gold nanoparticles are selectively coupled to the immunocomplex to cause signal amplification, the sensitivity reaches the ten to one hundred picomolar level but the time required increases to about 60 min.  相似文献   

3.
Force mapping with the atomic force microscope (AFM) allows the simultaneous acquisition of topography and probe-sample interaction data. For example, AFM probes functionalised with an antigen can be employed to map the spatial distribution of recognition events on a substrate functionalised with its specific antibody. However, to date this method has been limited to the detection of single receptor-ligand species. Were the detection of multiple receptor-ligand interactions possible, force mapping would offer great scope as a sensitive tool for bioassay and screening applications. We have developed an immobilisation strategy, which allows two different molecular species (in this case human serum albumin and the β subunit of human chorionic gonadotropin) to be present simultaneously on an AFM probe. Single point force spectroscopy results have revealed the ability of such probes to discriminate between their corresponding recognition points (anti-HSA and anti-βhCG IgG antibodies). As a control, force measurements were re-recorded in the presence of the known antigen (free in solution) for each antibody species and a marked decrease in the frequency of specific interaction is observed. As an additional control interactions between anti-βhCG IgG and the multifunctional probe are taken in the presence of free βhCG (“true” antigen) and free HSA (“false” antigen). It is shown that measurements recorded in the presence of a non-related protein species results in no change in either the force observed or the frequency of specific interactions, further confirmation that the specificity of force observed is due to the separation of antibody-antigen complex.  相似文献   

4.
We report a high-sensitivity, disposable lab-on-a-chip with a thin-film organic light-emitting diode (OLED) excitation source and an organic photodiode (OPD) detector for on-chip fluorescence analysis. A NPB/Alq3 thin-film green OLED with an active area of 0.1 cm(2) was used as the excitation source, while a CuPC/C(60) thin-film OPD with 0.6 cm(2) active area was used as a photodetector. A novel cost-effective, cross-polarization scheme was used to filter out excitation light from a fluorescent dye emission spectrum. The excitation light from the OLED was linearly polarized and used to illuminate a microfluidic device containing a 1 microL volume of dye dissolved in ethanol. The detector was shielded by a second polarizer, oriented orthogonally to the excitation light, thus reducing the photocurrent due to excitation light leakage on the detector by approximately 25 dB. The fluorescence emission light, which is randomly polarized, is only attenuated by approximately 3 dB. Fluorescence signals from Rhodamine 6G (peak emission wavelength of 570 nm) and fluorescein (peak emission wavelength of 494 nm) dyes were measured in a dilution series in the microfluidic device with emission signals detected by the OPD. A limit-of-detection of 100 nM was demonstrated for Rhodamine 6G, and 10 microM for fluorescein. This suggests that an integrated microfluidic device, with an organic photodiode and LED excitation source and integrated polarizers, can be fabricated to realize a compact and economical lab-on-a-chip for point-of-care fluorescence assays.  相似文献   

5.
This paper described a convenient semiquantitative method for colorimetric detection of protein with self-calibration integrated on the test strip. Hydrophilic paper was employed as microfluidic device for running colorimetric assay, tree-shaped design was developed to ensure uniform microfluidic flow for multiple branches. The approach was validated with bovine serum albumin (BSA) colorimetric detection, and colorimetric results observed by naked eyes were consistent with that from apparatus. The device could be coupled with digital transmission of images for remote monitoring system for diagnosis, food control, and environmental analysis.  相似文献   

6.
Biomolecular recognition of antigens and epitopes by antibodies is a fundamental event in the initiation of immune response and plays a central role in a variety of biochemical processes. Peptide binding requires, in many cases, presentation of the peptides at interfaces, such as protein surfaces, cellular membranes, and synthetic polymer surfaces. We describe a novel molecular system in which interactions between antibodies and peptide epitopes displayed at a biomimetic membrane interface can be detected through induction of visible, rapid color transitions. The colorimetric assembly consists of a phospholipid/polydiacetylene matrix anchoring a hydrophobic peptide displaying the epitope at its N-terminus. The colorimetric transitions observed in the assembly, corresponding to perturbation of the polydiacetylene framework, are induced only upon recognition of the displayed epitope by its specific antibody present in the aqueous solution. Significantly, the color changes occur after a single mixing step, without further chemical reactions or enzymatic processing. The new molecular system could be utilized for studying antigen-antibody interactions and peptide-protein recognition, epitope mapping, and rapid screening of biological and chemical libraries.  相似文献   

7.
Yang F  Li XC  Zhang W  Pan JB  Chen ZG 《Talanta》2011,84(4):1155-1106
In this paper, a compact and inexpensive light emitting diode induced fluorescence (LED-IF) detector with simplified optical configuration was developed and assembled in an integrated microfluidic device for microscale electrophoresis. The facile detector mainly consisted of an LED, a focusing pinhole, an emission filter and a photodiode, and was encapsulated in the upper layer of an aluminum alloy device with two layers. At the bottom layer, integrated circuit (IC) was assembled to manipulate the voltage for sample injection and separation, LED emission and signal amplifying. A high-power LED with fan-shaped heat sink was used as excitation source. The excitation light was focused by a 1.1 mm diameter pinhole fabricated in a thin piece of silver foil, and the obtained sensitivity was about 3 times as high as that using electrode plate. Other important parameters including LED driven current, fluorescence collection angle and detection distance have also been investigated. Under optimal conditions, considerable high-response of 0.09 fmol and 0.18 fmol mass detection limits at 0.37 nL injection volume for sodium fluorescein (SF) and FITC was achieved, respectively. This device has been successfully employed to separate penicillamine (PA) enantiomers. Due to such significant features as low-cost, integration, miniaturization, and ease of commercialization, the presented microfluidic device may hold great promise for clinical diagnostics and bioanalytical applications.  相似文献   

8.
Zhu L  Lee CS  DeVoe DL 《Lab on a chip》2006,6(1):115-120
An integrated UV absorbance detection system employing a novel silicon-in-plastic technology to seamlessly integrate bare UV photodiode chips into polymer microfluidic systems has been developed. Detection platforms fabricated using this approach exhibit exceptionally low concentration and mass detection limits down to 15 nM and 9.8 amol, respectively, for bovine serum albumin (BSA) as a model protein. In addition to providing high sensitivity, sub-nanoliter detection volumes are enabled by the use of direct photodiode integration. The fabrication methodology is detailed, and system performance metrics including detection limits, detection volume, dynamic range, and linearity are reported.  相似文献   

9.
Fluorescence polarization detection for affinity capillary electrophoresis   总被引:1,自引:0,他引:1  
Le XC  Wan QH  Lam MT 《Electrophoresis》2002,23(6):903-908
Affinity capillary electrophoresis (ACE) with laser-induced fluorescence polarization (LIFP) detection is described, with examples of affinity interaction studies. Because fluorescence polarization is sensitive to changes in the rotational motion arising from molecular association or dissociation, ACE-LIFP is capable of providing information on the formation of affinity complexes prior to or during CE separation. Unbound, small fluorescent probes generally have little fluorescence polarization because of rapid rotation of the molecule in solution. When the small fluorescent probe is bound to a larger affinity agent, such as an antibody, the fluorescence polarization (and anisotropy) increases due to slower motion of the much larger complex molecule in the solution. Fluorescence polarization results are obtained by simultaneously measuring fluorescence intensities of vertical and horizontal polarization planes. Applications of CE-LIFP to both strong and weak binding systems are discussed with antibody-antigen and DNA-protein binding as examples. For strong affinity binding, such as between cyclosporine and its antibody, complexes are formed prior to CE-LIFP analysis. For weaker binding, such as between single-stranded DNA and its binding protein, the single-stranded DNA binding protein is added to the CE separation buffer to enhance dynamic formation of affinity complexes. Both fluorescence polarization (and anisotropy) and mobility shift results are complementary and are useful for immunoassays and binding studies.  相似文献   

10.
11.
微流控芯片实验室   总被引:3,自引:0,他引:3  
林炳承  秦建华 《色谱》2005,23(5):456-463
以作者所在课题组近年来的研究工作为基础,就芯片实验室平台建设及相应的以系统生物学为最终目标的功能化研究作一说明,对在分子和细胞层面,甚至是单分子、单细胞水平上实现以规模集成为特征的临床诊断和药物筛选的努力予以特别的关注。  相似文献   

12.
Towards developing rapid and portable diagnostics for detecting zoonotic diseases, we have developed microchip-based electrophoretic immunoassays for sensitive and rapid detection of viruses. Two types of microchip-based electrophoretic immunoassays were developed. The initial assay used open channel electrophoresis and laser-induced fluorescence detection with a labeled antibody to detect influenza virus. However, this assay did not have adequate sensitivity to detect viruses at relevant concentrations for diagnostic applications. Hence, a novel assay was developed that allows simultaneous concentration and detection of viruses using a microfluidic chip with an integrated nanoporous membrane. The size-exclusion properties of the in situ polymerized polyacrylamide membrane are exploited to simultaneously concentrate viral particles and separate the virus/fluorescent antibody complex from the unbound antibody. The assay is performed in two simple steps--addition of fluorescently labeled antibodies to the sample, followed by concentration of antibody-virus complexes on a porous membrane. Excess antibodies are removed by electrophoresis through the membrane and the complex is then detected downstream of the membrane. This new assay detected inactivated swine influenza virus at a concentration four times lower than that of the open-channel electrophoresis assay. The total assay time, including device regeneration, is six minutes and requires <50 microl of sample. The filtration effect of the polymer membrane eliminates the need for washing, commonly required with surface-based immunoassays, increasing the speed of the assay. This assay is intended to form the core of a portable device for the diagnosis of high-consequence animal pathogens such as foot-and-mouth disease. The electrophoretic immunoassay format is rapid and simple while providing the necessary sensitivity for diagnosis of the illness state. This would allow the development of a portable, cost-effective, on-site diagnostic system for rapid screening of large populations of livestock, including sheep, pigs, cattle, and potentially birds.  相似文献   

13.
A microfluidic lab-on-a-chip (LoC) platform for in vitro measurement of glucose for clinical diagnostic applications is presented in this paper. The LoC uses a discrete droplet format in contrast to conventional continuous flow microfluidic systems. The droplets act as solution-phase reaction chambers and are manipulated using the electrowetting effect. Glucose is measured using a colorimetric enzyme-kinetic method based on Trinder’s reaction. The color change is detected using an absorbance measurement system consisting of a light emitting diode and a photodiode. The linear range of the assay is 9-100 mg/dl using a sample dilution factor of 2 and 15-300 mg/dl using a sample dilution factor of 3. The results obtained on the electrowetting system compare favorably with conventional measurements done on a spectrophotometer, indicating that there is no change in enzyme activity under electrowetting conditions.  相似文献   

14.
介绍了用于DNA检测的各种光学分析方法及其原理,主要包括荧光法、化学发光法、光纤传感法、比色法、表面等离子共振法以及其他光学衍生方法。  相似文献   

15.
We report an integrated microfluidic device for fine-scale manipulation and confinement of micro- and nanoscale particles in free-solution. Using this device, single particles are trapped in a stagnation point flow at the junction of two intersecting microchannels. The hydrodynamic trap is based on active flow control at a fluid stagnation point using an integrated on-chip valve in a monolithic PDMS-based microfluidic device. In this work, we characterize device design parameters enabling precise control of stagnation point position for efficient trap performance. The microfluidic-based hydrodynamic trap facilitates particle trapping using the sole action of fluid flow and provides a viable alternative to existing confinement and manipulation techniques based on electric, optical, magnetic or acoustic force fields. Overall, the hydrodynamic trap enables non-contact confinement of fluorescent and non-fluorescent particles for extended times and provides a new platform for fundamental studies in biology, biotechnology and materials science.  相似文献   

16.
Single-molecule detection (SMD) has demonstrated some attractive benefits for many types of biomolecular analyses including enhanced processing speed by eliminating processing steps, elimination of ensemble averaging and single-molecule sensitivity. However, it's wide spread use has been hampered by the complex instrumentation required for its implementation when using fluorescence as the readout modality. We report herein a simple and compact fluorescence single-molecule instrument that is straightforward to operate and consisted of fiber optics directly coupled to a microfluidic device. The integrated fiber optics served as waveguides to deliver the laser excitation light to the sample and collecting the resulting emission, simplifying the optical requirements associated with traditional SMD instruments by eliminating the need for optical alignment and simplification of the optical train. Additionally, the use of a vertical cavity surface emitting laser and a single photon avalanche diode serving as the excitation source and photon transducer, respectively, as well as a field programmable gate array (FPGA) integrated into the processing electronics assisted in reducing the instrument footprint. This small footprint SMD platform was tested using fluorescent microspheres and single AlexaFluor 660 molecules to determine the optimal operating parameters and system performance. As a demonstration of the utility of this instrument for biomolecular analyses, molecular beacons (MBs) were designed to probe bacterial cells for the gene encoding Gram-positive species. The ability to monitor biomarkers using this simple and portable instrument will have a number of important applications, such as strain-specific detection of pathogenic bacteria or the molecular diagnosis of diseases requiring rapid turn-around-times directly at the point-of-use.  相似文献   

17.
An integrated microfluidic biosensor is presented that combines sample pre-concentration and liposome-based signal amplification for the detection of enteric viruses present in environmental water samples. This microfluidic approach overcomes the challenges of long assay times of cell culture-based methods and the need to extensively process water samples to eliminate inhibitors for PCR-based methods. Here, viruses are detected using an immunoassay sandwich approach with the reporting antibodies tagged to liposomes. Described is the development of the integrated device for the detection of environmentally relevant viruses using feline calicivirus (FCV) as a model organism for human norovirus. In situ fabricated nanoporous membranes in glass microchannels were used in conjunction with electric fields to achieve pre-concentration of virus–liposome complexes and therefore enhance the antibody–virus binding efficiency. The concentrated complexes were eluted to a detection region downstream where captured liposomes were lysed to release fluorescent dye molecules that were then quantified using image processing. This system was compared to an optimized electrochemical liposome-based microfluidic biosensor without pre-concentration. The limit of detection of FCV of the integrated device was at 1.6 × 105 PFU/mL, an order of magnitude lower than that obtained using the microfluidic biosensor without pre-concentration. This significant improvement is a key step toward the goal of using this integrated device as an early screening system for viruses in environmental water samples.  相似文献   

18.
Li J  Yao QH  Fu HE  Zhang XL  Yang HH 《Talanta》2011,85(1):91-96
Horseradish peroxidase mimicking DNAzyme (HRP-DNAzyme) attracts growing interest as an amplifying label for biorecognition and biosensing events, especially for DNA detection. However, in the traditional designs, one target molecule can only generate one HRP-DNAzyme, which limits the signal enhancement and thus its sensitivity. In this article, we propose an amplified and label-free colorimetric DNA detection strategy based on nicking endonuclease (NEase)-assisted activation of HRP-DNAzymes (NEAA-DNAzymes). This new strategy relies on the hairpin-DNAzyme probe and NEase-assisted target recycling. In the hairpin-DNAzyme probe, the HRP-DNAzyme sequence is protected in a “caged” inactive structure, whereas the loop region includes the target complementary sequence. Upon hybridization with target, the beacon is opened, resulting in the activation of the HRP-DNAzyme. Meanwhile, upon formation of the duplex, the NEase recognizes a specific nucleotide sequence and cleaves the hairpin-DNAzyme probe into two fragments. After nicking, the fragments of the hairpin-DNAzyme probe spontaneously dissociate from the target DNA. Amplification is accomplished by another hairpin-DNAzyme probe hybridizing to the released intact target to continue the strand-scission cycle, which results in activation of numerous DNAzymes. The activated HRP-DNAzymes generate colorimetric or chemiluminescence readout signals, thus providing the amplified detection of DNA. The detection limit of the colorimetric method is 10 pmol/L, which are three orders of magnitude lower than that without NEase. In addition, the detection limit of the chemiluminescence method is 0.2 pmol/L. Meanwhile, this strategy also exhibits high discrimination ability even against single-base mismatch.  相似文献   

19.
Staphylococcal enterotoxins are a family of toxic proteins secreted by S. aureus. Using capillary electrophoresis (CE) linked with laser-induced fluorescence, a highly sensitive and selective assay using antibody-antigen recognition was developed for the determination of Staphylococcal enterotoxin A. Staphylococcal enterotoxin A (SEA) was chemically labeled with fluorescein and the product was used as a fluorescent tracer. A competitive assay was developed to detect SEA at concentrations between 0.3 nM and 6.5 nM with standard deviations of less than 5%. The detection limit was found to be 3 amol with the potential improvement by further optimization of the assay. No cross-reactivity between staphylococcal enterotoxin B and the SEA antibody was found at the concentrations used for the CE immunoassay.  相似文献   

20.
A novel sandwich assay with molecular beacons as report probes has been developed and integrated into one-dimensional microfluidic beads array (1-D chip) to pursue a label-free and elution-free detection of DNA/mRNA targets. In contrast with the immobilized molecular beacons, this sandwich assay can offer lower fluorescence background and correspondingly higher sensitivity. Furthermore, this sandwich assay on 1-D chip operating in conjunction with molecular beacon technique allows multiple targets detection without the need of laborious and time-consuming elution, which makes the experiment process simple, easy to handle, and reproducible results. In the experiment, the synthesized DNA targets with different concentrations were detected with a detection limit of ∼0.05 nM. Moreover, the mRNA expression changes in A549 cells before and after anticancer drug 5-flouorouracil treatments were detected and the results were validated by the conventional RT-PCR method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号