首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Shi G  Luo M  Xue J  Xian Y  Jin L  Jin JY 《Talanta》2001,55(2):241-247
A novel electrochemical sensor for the detection of sulfur dioxide in both gas and solution is described. The chemically modified electrode was constructed by polymerizing (4-VP), palladium and iridium oxide (PVP/Pd/IrO(2)) onto a platinum microelectrode which exhibits excellent catalytic activity toward sulfite with an oxidation potential of +0.50 V. The SO(2) gas sensor is based on the PVP/Pd/IrO(2) modified electrode as working electrode, Ag/AgCl electrode as reference electrode, Pt electrode as counter electrode and a porous film, which is in direct contact with the gas-containing atmosphere. The effect of different internal electrolyte solutions of hydrochloric acid, sulfuric acid, phosphates buffer solution, mixed solution of dimethyl sulfoxide and sulfuric acid to the determination of SO(2) was also studied. The sensor was found to have a high current sensitivity, a short response time and a good reproducibility for the detection of SO(2). It has good potential to be used in the field of environmental monitoring and controlling.  相似文献   

2.
Yamamoto K  Shi G  Zhou T  Xu F  Xu J  Kato T  Jin JY  Jin L 《The Analyst》2003,128(3):249-254
In this paper, multi-walled carbon nanotubes (MWCNTs) were successfully immobilized on the surface of a glassy carbon electrode by mixing with horse-radish peroxidase (HRP). The electrochemical behavior of H2O2 was also studied with the MWCNTs-HRP modified electrode as a working electrode. The MWCNTs-HRP modified electrode showed excellent response of reduction current for the determination of H2O2 at the potential of -300 mV (vs. Ag/AgCl). We assembled the MWCNTs-HRP modified electrode in a thin-layer flow cell and the H2O2 solution was continuously introduced into the cell with a syringe pump. We optimized the sensitivity of the H2O2 sensor by adjusting the working potential and the pH of the buffer solution. The peak current increased linearly with the concentration of H2O2 in the range 3.0 x 10(-7) to approximately 2.0 x 10(-4) mol L(-1). The detection limit is 1.0 x 10(-7) mol L(-1) (S/N = 3). The interferences from ascorbic acid, uric acid and other electroactive substances can be greatly excluded since the sensor can be operated at -300 mV. Stability and reproducibility of the MWCNTs-HRP chemically modified electrode were also studied in this paper. Fabricated with glucose and lactate oxidase, the MWCNTs-HRP electrode was also applied to prepare the on-line glucose and lactate biosensors because of the high sensitivity for the determination of H2O2.  相似文献   

3.
T Ponnuswamy  J J Chen  F Xu  O Chyan 《The Analyst》2001,126(6):877-880
Potentiometric detection of trace levels of metallic contamination onset in hydrofluoric acid using a silicon-based sensor in conjunction with two non-contaminating reference electrode systems is presented in this paper. In the first case, conductive diamond was used as a non-contaminating reference electrode. Cyclic voltammetry and open-circuit potential experiments demonstrated the feasibility of using a conductive diamond film electrode as a quasi-reference electrode in the HF solution. In the second case, a dual silicon electrode system was used with one of the silicon-based electrodes protected with an anion permeable membrane behaving as the quasi-reference electrode. The dual silicon sensing electrode system possessed an additional operational advantage of being unaffected by the solution acidity. Though both sensing configurations were able to detect the metal ion contamination onsets at the parts-per-trillion to parts-per-billion levels, the dual silicon electrode design showed a greater compatibility for the on-line detection of metallic impurities in HF etching baths commonly used in semiconductor processing.  相似文献   

4.
The influence of the iridium oxide thin film on the electrocatalytic properties of platinum nanoparticles was investigated using the electro-oxidation of methanol and CO as a probe. The presence of the IrO(2) thin film leads to the homogeneous dispersion of Pt nanoparticles. For comparison, polycrystalline platinum and Pt nanoparticles dispersed on a Ti substrate in the absence of an IrO(2) layer (Ti/Pt) were also investigated in this study. Inverted and enhanced CO bipolar peaks were observed using an in situ electrochemical Fourier transform infrared technique during the methanol oxidation on the Pt nanoparticles dispersed on a Ti substrate. Electrochemical impedance studies showed that the charge transfer resistance was significantly lower for the Ti/IrO(2)/Pt electrode compared with that of the massive Pt and Ti/Pt nanoparticles. The presence of the IrO(2) thin film not only greatly increases the active surface area but also promotes CO oxidation at a much lower electrode potential, thus, significantly enhancing the electrocatalytic activity of Pt nanoparticles toward methanol electro-oxidation.  相似文献   

5.
《Electroanalysis》2018,30(3):561-570
Complete all‐in‐one multi‐arrayed glutamate (Glut) sensors have been constructed on a silicon‐based micromachined probe composed of micro‐platinum (Pt) working electrodes, a micro‐silver/silver chloride (Ag/AgCl) reference electrode (RE), and a micro‐Pt counter electrode (CE). The OCP shift of the electrodeposited Ag/AgCl on‐probe micro‐reference electrode compared with a Ag/AgCl wire is <0.1 mV/h. The composition ratio of Ag, Cl, and Pt on the electrodeposited on‐probe micro‐reference electrode is observed to be 1.00 : 0.48 : 0.02 analyzed by EDS. The miniaturized amperometric Glut biosensors were constructed on working electrode sites (electrode area: ∼8.5×10−5 cm2) of the microprobe modified with glutamate oxidase (GlutOx) enzyme layers for the selective, fast, and continuous detection of L‐glutamate. The sensor selectivity towards common electroactive interferents has been improved significantly by coating the electrode surface with perm‐selective polymer layers, overoxidized polypyrrole (PPY) and Nafion®. The sensitivity, detection range, and response time of the proposed all‐in‐one Glut biosensors are 204.7±5.8 nA μM−1 cm−2 (N=5), 4.99–109 μM, and 2.7±0.3 sec, respectively and no interferent signals of AA and DA were observed. The sensor can be reused over 19 times of continuous repetitive operation (total measurement time: ∼4 hours) and the sensor sensitivity can retain up to four weeks of storage.  相似文献   

6.
A planar platinum electrode was covered by a photopolymer membrane containing glucose oxidase (GOD) to construct an amperometric glucose sensor. The application of a photopolymer system in membrane formation gives the opportunity to manufacture cheap biosensors with good reproducibility by means of automated techniques and to miniaturise sensors using photolithography. The electrodes were pretreated mechanically and chemically resulting in a half-wave potential (E1/2) of the H2O2 oxidation shifted towards more negative potentials. This shift allows the determination of glucose at a low working potential (300 mV vs. SCE) without addition of mediators. The important advantage of such applied potential decreasing lies in minimising the interference of oxidisable substances such as uric acid, bilirubin and paracetamol. The selectivity to ascorbic acid could also be proved without the application of additional protection layers. The glucose sensor developed has a high life-time, selectivity and sensitivity and a linear working concentration range from 0.05 up to 10 mmol/l of glucose. The sensor was used for the glucose determination in human serum samples with a very good correlation to a common photometric reference method. Received: 13 July 1996 / Revised: 11 September 1996 / Accepted: 14 September 1996  相似文献   

7.
Xiangjie Bo  Jing Bai 《Talanta》2010,82(1):85-214
A simple and facile synthetic method to incorporate Pt nanoparticles inside the mesopores of ordered mesoporous carbons (OMCs) is reported. The Pt/OMCs nanocomposite was characterized by transmission electron microscopy (TEM), X-ray diffraction (XRD), X-ray photoelectron spectroscopy (XPS), Raman spectroscopy, and nitrogen adsorption-desorption. The results show that the incorporation of Pt nanoparticles inside the pores of OMCs does not change the highly ordered two-dimensional hexagonal mesostructure of OMCs matrix. Nonenzymatic amperometric sensor of hydrogen peroxide and glucose based on the Pt/OMCs nanocomposite-modified glassy carbon (GC) electrode is developed. Compared with the original OMCs-modified electrode, the Pt/OMCs-modified electrode displays improved current response towards hydrogen peroxide and gives linear range from 2 to 4212 μM. At an applied potential of −0.08 V, the Pt/OMCs nanocomposite gives linearity in the range of 0.5-4.5 mM glucose in neutral buffered saline solution. This glucose sensor also exhibits good ability of anti-interference to electroactive molecules. The combination the unique properties of Pt nanoparticles and the ordered mesostructure of OMCs matrix guarantees the enhanced response for hydrogen peroxide and glucose.  相似文献   

8.
The direct electrochemistry of glucose oxidase (GOD) immobilized on a hexagonal mesoporous silica modified glassy carbon electrode was investigated. The adsorbed GOD displayed a pair of redox peaks with a formal potential of -417 mV in 0.1 M pH 6.1 phosphate buffer solution (PBS). The response showed a diffusion-controlled electrode process with a two-electron transfer coupled with a two-proton transfer reaction process. GOD immobilized on a hexagonal mesoporous silica retained its bioactivity and stability. In addition, the immobilized GOD could electrocatalyze the oxidation of glucose to gluconlactone by taking ferrocene monocarboxylic acid (FMCA) as a mediator in N(2) saturated solutions, indicating that the electrode may have the potential application in biosensors to analyze glucose. The sensor could exclude the interference of commonly coexisted uric acid, p-acetaminophenol and ascorbic acid and diagnose diabetes very fast and sensitively. This work demonstrated that the mesoporous silica provided a novel matrix for protein immobilization and the construction of biosensors.  相似文献   

9.
本文利用欠电位沉积亚单层的Cu及Pt置换取代Cu的方法, 制备了具有不同表面元素组成的Pd/Pt二元合金电极(用Pd/Ptx表示, x指欠电位沉积Cu-Pt置换取代Cu过程的次数),并对其表面元素组成、氧还原性能进行了表征. 在控制欠电位沉积Cu的下限电位恒定(0.34 V)的前提下, 表面Pt/Pd的元素组成比通过重复欠电位沉积Cu及Pt置换取代Cu的次数(1~5次)来可控地调变. 光电子能谱(XPS) 以及红外光谱实验表明,Pd/Ptx电极表层区的Pt:Pd元素组成比随着Pt沉积次数增加而增加, 对Pd/Pt4电极, 在电极表层区约2~3 nm内的Pt/Pd的原子比大约是1:4,而最表层裸露Pd原子的比例仍在20%以上。循环伏安结果显示, 随着Pt沉积次数的增加(1-5次), Pd/Ptx电极表面越不易被氧化。氧还原测试结果显示随着Pt沉积次数的增加(1~4次), Pd/Ptx二元金属电极的氧还原活性依次增加, 经过第3次沉积后其氧还原活性已优于纯Pt,而经4次以上沉积,其氧还原活性基本不变。在其它反应条件相同条件的前提下, Pd/Pt4电极上氧还原的半波电位与纯Pt相比右移约25 mV。结合本文与文献的实验结果,我们初步认为Pd/Ptx二元金属体系氧还原性能改善主要源自表层Pd原子导致其邻近的Pt原子上含氧物种吸附能的降低.  相似文献   

10.
A novel dimethyl sulfoxide (DMSO) sensor using DMSO reductase and film electrodes was constructed. The Au and Ag electrodes were fabricated on slide glass by vacuum deposition and the application of a photolithographic technique. The micro-chamber (4 x 50 x 1 mm, volume 200 microl) was fabricated on a poly(dimethylsiloxane) (PDMS) polymer. The Pt electrode was implanted in a PDMS polymer. DMSO reductase was immobilized on a Au film electrode with bovine serum albumin (BSA)-glutaraldehyde. This sensor could determine DMSO in an unpurged aqueous solution with glucose oxidase (GOD) and catalase (CAT) for oxygen removal. The DMSO sensor showed a linear response within 1 mM DMSO with a correlation coefficient of 0.999. The detection limit was 200 microM (3sigma), and the sensitivity was 23.8 mA M(-1) cm(-2). The relative standard deviations at each concentration were within 3.6%.  相似文献   

11.
Multi‐analyte real‐time interrogation of cellular activity allows for the potential discovery of novel insights into disease. In this report, the addition of electrochemical biosensors to a previously developed platform utilizing Au microfabricated electrodes was explored. Glucose oxidase was immobilized at the electrode surface with an osmium redox polymer, using hand‐casting and electrodeposition techniques, allowing for the first comparison of deposition techniques at a Au microfabricated array. This preliminary work is the first step toward the goal of creating a multi‐analyte array for cellular analysis.  相似文献   

12.
Two different biodegradable latex polymers functionalised by hydroxy (1) or gluconamide (2) groups proved to be good immobilisation matrixes for glucose oxidase. The responses of these biosensors to glucose additions were measured by potentiostating the modified electrodes at 0.6 V/SCE in order to oxidise the hydrogen peroxide generated by the enzymatic oxidation of glucose in the presence of oxygen. The response of such electrodes was evaluated as a function of film thickness, pH and temperature. Rotating disk electrode experiments showed the influence of the enzyme on the structure of both latex films, namely a marked improvement in matrix permeability. The high permeability of the latex 1 based enzyme sensor (bilayer, P(m)=8.10x10(-4) cm s(-1)) resulted in a high dynamic range. Furthermore, the activation energy for a latex 1 sensor was determined to be 44.55 and 18.03 kJ mol(-1), respectively depending on the conformation of the enzyme.  相似文献   

13.
We report here a nonenzymatic sensor by using a nanoporous platinum electrode to detect glucose directly. The electrode was fabricated by electrochemical deposition and dissolution of PtZn alloy in zinc chloride‐1‐ethyl‐3‐methylimidazolium chloride (ZnCl2‐EMIC) ionic liquid. Both SEM and electrochemical studies showed the evidences for the nanoporous characteristics of the as‐prepared Pt electrodes. Amperometric measurements allow observation of the electrochemical oxidation of glucose at 0.4 V (vs. Ag/AgCl) in pH 7.4 phosphate buffer solution. The sensor also demonstrates significant reproducibility in glucose detection; the higher the roughness factor of the Pt electrode, the lower the detection limit of glucose. The interfering species such as ascorbic acid and p‐acetamidophenol can be avoided by using a Pt electrode with a high roughness factor of 151. Overall, the nanoporous Pt electrode is promising for enzymeless detection of glucose at physiological condition.  相似文献   

14.
《Electroanalysis》2003,15(13):1109-1114
The electrochemical characterization of a hydrogen peroxide sensor based on a ferrocene‐containing polymer electrochemically deposited onto a platinum electrode is described. The redox polymer consists of a siloxane‐based homopolymer, with pendant electronically communicated ferrocenyl moieties. The electrodes were used as the transducer for glucose and lactate‐sensing enzyme sensors. Amperometric biosensors were prepared by immobilization of glucose oxidase (Gox) or lactate oxidase (Lox) onto these modified electrodes. The steady‐state amperometric response of the sensors is investigated as a function of the applied potential and substrate concentration. Interferences, sensitivity and stability of the sensors were also studied.  相似文献   

15.
《Electroanalysis》2006,18(5):465-470
Nickel and platinum find extensive use in preparation of biosensors. In the present work, Ni/Pt alloy was plated on graphite to make acetylcholine sensor. The microstructure, surface composition and electrochemical performance of the electrode was analyzed by different techniques. The sensing performance was evaluated by cyclic voltammetry. The prepared alloy plate exhibited very good linear relationship between acetyl choline concentration and response current. The sensitivity and reproducibility of the prepared electrode were found better than other nickel electrodes reported.  相似文献   

16.
Glucose biosensors based on lyophilised, crystalline and cross-linked glucose oxidase (GOx, CLEC(R)) and commercially available lyophilised GOx immobilised on top of glassy carbon electrodes modified with electrodeposited Prussian Blue are critically compared. Two procedures were carried out for preparing the biosensors: (1) deposition of one layer of adsorbed GOx dissolved in an aqueous solution followed by deposition of two layers of low molecular weight Nafion(R) dissolved in 90% ethanol, and (2) deposition of two layers of a mixture of GOx with Nafion dissolved in 90% ethanol. The performance of the biosensors was evaluated in terms of linear response range for hydrogen peroxide and glucose, detection limit, and susceptibility to some common interfering species (ascorbic acid, acetaminophen and uric acid). The operational stability of the biosensors was evaluated by applying a steady potential of -50 mV versus Ag/AgCl to the glucose biosensor and injecting standard solutions of hydrogen peroxide and glucose (50 muM and 1.0 mM, respectively, in phosphate buffer) for at least 5 h in a flow-injection system. Scanning electron microscopy was used for visualisation of the Prussian Blue redox catalyst and in the presence of the different GOx preparations on the electrode surface.  相似文献   

17.
Edge plane pyrolytic graphite (EPG) electrodes coated with 5-(4-pyridyl)-10,15,20-tris(3-methoxy-4-hydroxyphenyl)porphyrin and its Pt(II) and Co(II)/Pt(II) analogs undergo an electrochemical-chemical-electrochemical (ECE) reaction when anodically scanned in 1.0 M HClO4. The new redox couple formed from this anodic conditioning of the coated electrode is dependent on the pH of the solution. Roughened EPG electrodes coated with the Co(II)/Pt(II) bimetallic porphyrin show a catalytic shift of 500 mV for the reduction of O2 when compared to the reduction of O2 at a bare EPG electrode. An additional catalytic shift of ca. 100 mV is observed for O2 reduction at an EPG electrode coated with the Co(II)/Pt(II) porphyrin which has been oxidized in 1.0 M HClO4. In addition to the added electrocatalysis a significant percentage of O2 reduced at the oxidized Co(II)/Pt(II) EPG electrode is converted to H2O as determined by rotating disk electrode measurements.  相似文献   

18.
For a series of graphite electrodes, modified with microquantities of Pd+Pt mixture in varied proportions, surface morphology of the catalytically active phase was studied with scanning electron microscopy (SEM), while the catalytic activity was examined at electrochemical reduction of hydrogen peroxide by means of steady-state polarization curves and constant potential amperometry. It was proven that the graphite, exhibiting the highest electrocatalytic activity (modified with Pd+Pt mixed in the ratio 70%:30% at t(deposit)=10 s) is distinguished with the smallest average size of the microformations. The operational characteristics of the same electrode and graphite modified with microquantities of Pd+Au mixed in the same ratio (70%:30%; t(deposit)=10 s) were compared. The application of these electrodes as basic transducers in highly selective biosensors for glucose and xanthine was demonstrated.  相似文献   

19.
Yang S  Lu Y  Atanossov P  Wilkins E  Long X 《Talanta》1998,47(3):735-743
A microfabricated glucose biosensor based on an amperometeric hydrogen peroxide electrode has been developed. A sol-gel layer with 5 A pore size and 2 mum thickness was used as the glucose oxidase entrapping matrix. The sol-gel matrix formed over the silicon-based sensor has good mechanical and chemical stability, and the ability to entrap a large amount of enzyme. The miniaturized electrode sensing system is composed of platinum as both working and counter electrodes and silver as a reference electrode. Nafion(R) coating was applied as the interference limiting layer. A series of technologies, such as standard photolithography, electron beam evaporation and image reverse lift-off were utilized for mass production allowing 143 electrodes to be produced at the same time. The effect of oxidable interferences was <10% of the background value of the sensor response. Calibration tests of a series of individual sensors manufactured from the same silicon wafer and dip coated in the same conditions, showed a highly reproducible response characteristics (linear range up to 500 mg dl(-1) and mean sensitivity of 0.54+/-0.14 nA mg(-1) dl(-1) (n=10)).  相似文献   

20.
《Analytical letters》2012,45(7):746-753
In this work, we report the direct electrochemistry of glucose oxidase (GOD) observed at a gold electrode modified with graphene nanosheets. Initially, graphene nanosheets were synthesized and conjugated to the enzyme GOD and immobilized on to a gold electrode surface. Cyclic voltammetry was then performed using Gold-Graphene-GOD modified electrodes in a pH 7.2 phosphate buffered saline (PBS). A pair of well-defined redox peaks was obtained for GOD with the reduction peak centered at +180 mV and a peak separation of 70 mV in PBS under physiological conditions. Moreover, the electron transfer rate of GOD redox reaction was greatly enhanced and the peak potential was found to be pH dependent at the graphene-GOD surface. Further, the performance of the Gold-Graphene-GOD was found to be stable and excellent under physiological conditions indicating the possibility of employing this platform for real time analysis. The observed results indicated that the 2D-graphene holds great promise for conjugation ability with a variety of enzymes. Further, our results also confirmed that graphene is capable of holding the enzyme GOD in a favorable position and retains its original structure and functionality that are essential for biosensing.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号