首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A catalytic flow-injection (FI) method was developed for the determination of 10−9 mol l−1 levels of vanadium(IV, V). The method is based on the catalytic effect of vanadium(V) on oxidation of N-(3-sulfopropyl)-3,3′,5,5′-tetramethylbenzidine (TMBZ·PS) using bromate as oxidant to form a yellow dye (λmax=460 nm). The use of 5-sulfosalicylic acid (SSA) as an activator enhanced the sensitivity of the method. The calibration graphs with a working range 0.05–8.0 ng ml−1 were obtained for vanadium(V). Vanadium(IV) was also determined, being oxidized by bromate. The detection limit (signal/noise, S/N=3) was 0.01 ng ml−1 (ca. 2×10−10 mol l−1) vanadium. The relative standard deviations (R.S.D.) for 15 determinations of 0.5 ng ml−1 vanadium, and for ten determinations of 0.1 and 1.0 ng ml−1 vanadium were 0.41, 2.6 and 0.25%, respectively, with a sampling rate of 15 samples h−1. The proposed method was successfully applied to the determination of vanadium in natural waters.  相似文献   

2.
By designing a novel flow-through electrolytic cell (FEC), bromine was produced near to the surface of the platinum electrode by electrochemical oxidation of acidic KBr. The fast and weak chemiluminescence signal produced by the chemical reaction of the electrogenerated bromine with H2O2 was greatly enhanced by tetracyclines Based on these observations, a new, sensitive and simple electrogenerated chemiluminescence (ECL) method for the determination of tetracyclines was developed. Under the optimum experimental conditions, the calibration graphs are linear over the range 3.0×10−8 to 5.0×10−5 g ml−1 for tetracycline, 2.0×10−7 to 2.4×10−5 g ml−1 for oxytetracycline and 1.0×10−7 to 5.0×10−5 g ml−1 for chlortetracycline. The limits of detection (S/N=3) are 1.0×10−8 g ml−1 for tetracycline, 7.0×10−8 g ml−1 for oxytetracycline and 1.5×10−7 g ml−1 for chlortetracycline. For the determination 5.0×10−7 g ml−1 tetracycline, the relative standard deviation was <5%. The proposed method was used to determine tetracyclines in pharmaceutical formulations.  相似文献   

3.
A highly sensitive and selective method is described for the determination of trace amounts of nitrite based on its effect on the oxidation of carminic acid with bromate. The reaction was monitored spectrophotometrically by measuring the decrease in absorbance of carminic acid at 490 nm after 3 min of mixing the reagents. The optimum reaction conditions were 1.8×10−1 mol l−1 H2SO4, 3.8×10−3 mol l−1 KBrO3, and 1.2×10−4 mol l−1 carminic acid at 30°C. By using the recommended procedure, the calibration graph was linear from 0.2 to 14 ng ml−1 of nitrite; the detection limit was 0.04 ng ml−1; the R.S.D. for six replicate determinations of 6 ng ml−1 was 1.7%. The method is mostly free from interference, especially from large amounts of nitrate and ammonium ions. The proposed method was applied to the determination of nitrite in rain and river water.  相似文献   

4.
Two independent methods for the determination of diclofenac were simultaneously implemented in an automated analytical system, based on the concept of sequential injection analysis, providing real-time assessment of results quality. The potentiometric detection was carried out with an ion-selective electrode based on a cyclodextrin while for the fluorimetric determination the sample was previously subject to in-line irradiation with UV light. The potentiometric and photochemical-fluorimetric determinations exhibited linear working ranges of 5×10−6 to 1×10−2 and 1×10−6 to 1×10−4 mol dm−3, respectively. Relative standard errors of 0.5% for the potentiometric determination and 0.6% for the photochemical-fluorimetric determination were obtained after 10 consecutive injections of a 5×10−5 mol dm−3 diclofenac standard solution. The sampling rate was about 32 samples h−1. Both methods were applied in the analysis of pharmaceutical formulations. The quality of results obtained was evaluated by comparison to the reference method, with no statistically significant differences for a 95% confidence level.  相似文献   

5.
Hassan SS  Ali MM  Attawiya AM 《Talanta》2001,54(6):1153-1161
Two novel uranyl PVC matrix membrane sensors responsive to uranyl ion are described. The first sensor incorporates tris(2-ethylhexyl)phosphate (TEHP) as both electroactive material and plasticizer and sodium tetraphenylborate (NaTPB) as an ion discriminator. The sensor displays a rapid and linear response for UO22+ ions over the concentration range 1×10−1–2×10−5 mol l−1 UO22+ with a cationic slope of 25.0±0.2 mV decade−1. The working pH range is 2.8–3.6 and the life span is 4 weeks. The second sensor contains O-(1,2-dihydro-2-oxo-1-pyridyl)-N,N,N′,N′-bis(tetra-methylene)uronium hexafluorophosphate (TPTU) as a sensing material, sodium tetraphenylborate as an ion discriminator and dioctyl phenylphosphonate (DOPP) as a plasticizer. Linear and stable response for 1×10−1–5×10−5 mol l−1 UO22+ with near-Nernstian slope of 27.5±0.2 mV decade−1 are obtained. The working pH range is 2.5–3.5 and the life span of the sensor is 6 weeks. Interference from many inorganic cations is negligible for both sensors. However, interference caused by some ions (e.g. Th4+, Cu2+, Fe3+) is eliminated by a prior ion exchange or solvent extraction step. Direct potentiometric determination of as little as 5 μg ml−1 uranium in aqueous solutions shows an average recovery of 97.2±1.3%. Application for the determination of uranium at levels of 0.01–1 wt.% in naturally occurring and certified ores gives results with good correlation with data obtained by X-ray fluorescence.  相似文献   

6.
Chen GN  Zhang L  Lin RE  Yang ZC  Duan JP  Chen HQ  Hibbert DB 《Talanta》2000,50(6):1275-1281
The electrogenerated chemiluminescent (ECL) behavior of hemin at a platinum electrode in the alkaline solution has been investigated in detail. Under the optimum conditions the linear response range of hemin is 1.0×10−5–1.0×10−8 g ml−1, the detection limit was 1.0×10−8 g ml−1, and the relative standard derivation for 1×10−7 g ml−1 hemin was 2.8%. It has been also found that hemin would catalyze the ECL of lucigenin at a platinum electrode in a neutral solution in the presence of hydrogen peroxide, the catalytic ECL intensity was linear with the concentration of hemin in the range of 1.0×10−14–1.0×10−10 g ml−1. IgG labeled with hemin was used to examine the ECL catalytic activity of hemin after conjugating to protein, and the results showed that hemin retained ECL catalytic activity when conjugated to protein.  相似文献   

7.
An adsorptive stripping voltammetric (AdSV) procedure for simultaneous determination of Ni(II) and Co(II) in the presence of nioxime as a complexing agent at an in situ plated lead film electrode was described. The Co(II) signal was enhanced by exploitation of the catalytic process in the presence of nitrite. Ni(II) and Co(II) signals are better separated than in the case of bismuth film electrodes. Calibration graphs for an accumulation time of 120 s are linear from 1 × 10−9 to 1 × 10−7 mol L−1 and from 1 × 10−10 to 5 × 10−9 mol L−1 for Ni(II) and Co(II), respectively. The proposed procedure was applied for Ni(II) and Co(II) determination in water certified reference materials.  相似文献   

8.
Electrochemical studies of famotidine were carried out using voltammetric techniques: cyclic voltammetry, linear sweep and square wave adsorptive stripping voltammetry. The dependence of the current on pH, buffer concentration, nature of the buffer, and scan rate was investigated. The best results for the determination of famotidine were obtained in MOPS buffer solution at pH 6.7. This electroanalytical procedure enabled to determine famotidine in the concentration range 1 × 10−9–4 × 10−8 mol L−1 by linear sweep adsorptive stripping voltammetry (LS AdSV) and 5 × 10−10–6 × 10−8 mol L−1 by square wave adsorptive stripping voltammetry (SW AdSV). Repeatability, precision and accuracy of the developed methods were checked. The detection and quantification limits were found to be 1.8 × 10−10 and 6.2 × 10−10 mol L−1 for LS AdSV and 4.9 × 10−11 and 1.6 × 10−10 mol L−1 for SW AdSV, respectively. The method was applied for the determination of famotidine in urine.  相似文献   

9.
A new spectrophotometric flow-injection (FI) method is proposed for the determination of glucose based on the redox reaction of hydroquinone with iron(III). When a glucose solution containing quinone is passed through the immobilized glucose oxidase column introduced in FI system, quinone is reduced to hydroquinone by glucose. In the presence of 1,10-phenanthroline (phen), iron(III) is then quantitatively reduced by hydroquinone to iron(II) followed by the formation of iron(II)-phen complex (λmax=510 nm). An FI peak observed at 510 nm corresponds to the concentration of glucose. The wide dynamic range for glucose was obtained in the range of 1×10−6–1×10−3 mol l−1 at a sampling rate of 24 h−1 and the detection limit (S/N=3) was 5×10−7 mol l−1. Relative standard deviations were 0.78, 0.44 and 0.23% (n=5) for 5×10−6, 5×10−5 and 5×10−4 mol l−1 of glucose, respectively. The proposed method was successfully applied to the determination of glucose in control blood sera, human blood plasma and wine.  相似文献   

10.
A new, highly sensitive and simple kinetic method for the determination of thyroxine was proposed. The method was based on the catalytic effect of thyroxine on the oxidation of As(III) by Mn(III) metaphosphate. The kinetics of the reaction was studied in the presence of orthophosphoric acid. The reaction rate was followed spectrophotometrically at 516 nm. It was established that orthophosphoric acid increased the reaction rate and that the extent of the non-catalytic reaction was extremely small. A kinetic equation was postulated and the apparent rate constant was calculated. The dependence of the reaction rate on temperature was investigated and the energy of activation and other kinetic parameters were determined.

Thyroxine was determined under the optimal experimental conditions in the range 7.0 × 10−9 to 3.0 × 10−8 mol L−1 with a relative standard deviation up to 6.7% and a detection limit of 2.7 × 10−9 mol L−1. In the presence of 0.08 mol L−1 chloride, the detection limit decreased to 6.6 × 10−10 mol L−1. The proposed method was applied for the determination of thyroxine in tablets. The accuracy of the method was evaluated by comparison with the HPLC method.  相似文献   


11.
Agnihotri NK  Singh VK  Singh HB 《Talanta》1993,40(12):1851-1859
Derivative photometric methods for trace analysis of Th(IV) and UO2(II), and their simultaneous determination in mixtures using 5,8-dihydroxy-1,4-naphthoquinone in a micellar medium are reported. Molar absorptivity and Sandell's sensitivity of 1:2 Th(IV) and 1:1 UO2(II) complexes at their λmax, 614.5 nm and 637.0 nm are, 1.19 × 104 1/mol/cm and 1.12 × 104 1/mol/cm and 1.95 × 10−2 μg/cm2 and 2.13 × 10−2 μg/cm2 μg/cm2, respectively. Calibration graph is linear over the range 9.28 × 10−2−18.56 μg/ml of Th(IV) and 9.52 × 10−2−19.04 μg/ml of UO2(II). Though presence of Th(IV) and UO2(II) causes interference in each others determination, 9.28 × 10−1−9.28 μg/ml Th(IV) and 9.52 × 10−1−9.52 μg/ml UO2(II) when present together, can be simultaneously determined using derivative spectra.  相似文献   

12.
For elimination of copper interference in anodic stripping determinations of zinc at mercury and bismuth film electrodes gallium ions are usually added to the supporting electrolyte. In the presented studies novel ex situ formed gallium film electrode was applied for this purpose. The proposed electrode is less toxic than mercury one while the detection limit for zinc was lower than for bismuth film electrode following the same deposition time. The calibration graph for deposition time of 60 s was linear from 5 × 10−8 to 2 × 10−6 mol L−1. The determinations of zinc were carried out from undeaerated solutions. The proposed procedure was applied to zinc determination in certified reference material and tap water sample.  相似文献   

13.
The cathodic adsorptive electrochemical behavior of guanine in the presence of some metal ions at the static mercury drop electrode was investigated. A 1.0×10−3 mol l−1 NaOH or a 2.0×10−2 mol l−1 Hepes buffer at pH 8.0 solutions were used as supporting electrolytes. The reduction peak potential for guanine was found to be around −0.15 V, which is very close to the mercury reduction wave. A new peak appears at −0.60 V in the presence of copper or at −1.05 V in the presence of zinc. A square wave voltammetric procedure for electroanalytical determination of guanine in 2.0×10−2 mol l−1 Hepes buffer at pH 8.0 containing 1.6×10−5 mol l−1of copper ions, was developed. An accumulation potential of −0.15 V during 270 s for the prior adsorption of guanine at the electrode surface was used. The response of the system was found to be linear in the range of guanine concentration from 6.62×10−8 to 1.32×10−7 mol l−1 and the detection limit was 7.0×10−9 mol l−1. The influence of DNA bases such as adenine, cytosine and thymine was also examined. Cyclic voltammetry was used to characterize the interfacial and redox mechanism.  相似文献   

14.
Gong X  Zhou YK  Li HL 《Talanta》2001,55(6):1103-1107
2,2,6,6-Tetramethyl-4-hydroxypiperidine-1-oxyl (TMHPO) shows catalytic electroactivity in homogeneous oxidation of benzoyl hydrazine (BH) on a glassy carbon electrode. The catalytic current is affected by the concentration of TMHPO and the pH of the solution. A possible catalytic reaction mechanism is proposed and a non-toxic, convenient method for the determination of BH in the concentration range 1×10−5–2×10−3 M has been developed.  相似文献   

15.
Ohura H  Imato T  Yamasaki S 《Talanta》1999,49(5):1383-1015
A rapid potentiometric flow injection technique for the simultaneous determination of oxychlorine species such as ClO3–ClO2 and ClO3–HClO has been developed, using both a redox electrode detector and a Fe(III)–Fe(II) potential buffer solution containing chloride. The analytical method is based on the detection of a large transient potential change of the redox electrode due to chlorine generated via the reaction of the oxychlorine species with chloride in the potential buffer solution. The sensitivities to HClO and ClO2 obtained by the transient potential change were enhanced 700–800-fold over that using an equilibrium potential. The detection limit of the present method for HClO and ClO2 is as low as 5×10−8 M with use of a 5×10−4 M Fe(III)–1×10−3 M Fe(II) buffer containing 0.3 M KCl and 0.5 M H2SO4. On the other hand, sensitivity to ClO3 was low when a potential buffer solution containing 0.5 M H2SO4 was used, but could be increased largely by increasing the acidity of the potential buffer. The detection limit for ClO3 was 2×10−6 M with the use of a 5×10−4 M Fe(III)–1×10−3 M Fe(II) buffer containing 0.3 M KCl and 9 M H2SO4. By utilizing the difference in reactivity of oxychlorine species with chloride in the potential buffer, a simultaneous determination method for a mixed solution of ClO3–ClO2 or ClO3–HClO was designed to detect, in a timely manner, a transient potential change with the use of two streams of potential buffers which contain different concentrations of sulfuric acid. Analytical concentration ranges of oxychlorine species were 2×10−5–2×10−4 M for ClO3, and 1×10−6–1×10−5 M for HClO and ClO2. The reproducibility of the present method was in the range 1.5–2.3%. The reaction mechanism for the transient potential change used in the present method is also discussed, based on the results of batchwise experiments. The simultaneous determination method was applied to the determination of oxychlorine species in a tap water sample, and was found to provide an analytical result for HClO, which was in good agreement with that obtained by the o-tolidine method and to provide a good recovery for ClO3 added to the sample.  相似文献   

16.
Nie F  Lu J 《Talanta》2008,74(5):1242-1246
Calcein was found to be able to use as chemiluminescence reagent and post-chemiluminescence was observed when fenfluramine was injected into the mixture after the CL reaction of calcein–potassium permanganate. Based on this phenomenon, a flow injection CL method was established for the determination of fenfluramine. The possible CL mechanism was proposed. The CL intensity was correlated linearly with the concentration of fenfluramine over the range of 1.0 × 10−7 to 6.0 × 10−6 g mL−1 and the detection limit was 6 × 10−8 g mL−1. The relative standard deviation was 2.2% for 5.0 × 10−7 g mL−1 fenfluramine (n = 11). This method was applied to the determination of fenfluramine in weight-reducing tonic successfully.  相似文献   

17.
Wang Z  Zhang H  Zhou S  Dong W 《Talanta》2001,53(6):1133-1138
A novel method is described for determination of metoclopramide (MCP) by second-derivative adsorptive anodic stripping voltammetry with a nafion-modified electrode. The stripping peak current is proportional to the concentration of MCP over the range 1.2×10−9–4.6×10−7 M. The detection limit is 8.0×10−11 M with 4-min accumulation. The method has been successfully applied to the determination of MCP in human serum.  相似文献   

18.
Tomiyasu T  Teshima N  Nakano S  Kawashima T 《Talanta》1998,47(5):434-1098
A new kinetic-catalytic method by the initial rate procedure for the determination of nanogram level of iron(III) is developed, which is based on its catalytic effect on the oxidative coupling of 3-methyl-2-benzothiazolinone hydrazone (MBTH) with N,N-dimethylaniline (DMA) to form an indamine dye (λmax=590 nm) in the presence of hydrogen peroxide. Iron(II) is also determined, being oxidized to iron(III) by hydrogen peroxide. Calibration graphs obtained by the initial rate method are linear in the range 1–1000 ng ml−1 Fe and as low as 10−8 M Fe(II, III) can easily be determined. The relative standard deviations are 6.6, 2.5 and 1.5% for ten determinations of 1, 20 and 60 ng ml−1 of Fe(III), respectively. The method is applicable to the determination of iron in natural waters without preconcentration and separation.  相似文献   

19.
Xu J  Wang Y  Xian Y  Jin L  Tanaka K 《Talanta》2003,60(6):1123-1130
A multiwall carbon nanotubes (MWNTs) film modified electrode was prepared and used as an amperometric sensor for the simultaneous determination of oxidizable amino acids including cysteine, tryptophane and tyrosine. The electrochemical behaviors of these amino acids at this modified electrode were studied by cyclic voltammetry (CV). The results indicated that the MWNTs chemically modified electrode (CME) exhibited efficient electrocatalytic activity towards the oxidation of these amino acids with relatively high sensitivity, stability and long-life. Following separation by ion chromatography (IC) with 2.0×10−3 mol l−1 citric acid buffer solution (pH 6.5) as eluent, cysteine, tryptophane and tyrosine could be determined by the MWNTs CME successfully. Under the optimal conditions, the detection limits were 7.0×10−7 mol l−1 for cysteine, 2.0×10−7 mol l−1 for tryptophane and 3.5×10−7 mol l−1 for tyrosine at the signal-to-noise of 3, respectively. The method was applied successfully to the determination of these substances in plasma.  相似文献   

20.
Plasticized poly(vinyl chloride) (PVC) membranes of different compositions were tested for use in the construction of potentiometric flow detectors for triiodide. A membrane with a 2:1 (w/w) 2-nitrophenyl octyl ether to PVC ratio was selected. The influence of thiosulphate in the carrier solution composition and of the flow-injection variables on the determination of triiodide was studied. In the selected conditions, a linear relationship between peak height and log[I3] was obtained between 5 × 10−6 and 1 × 10−4 mol l−1 triiodide. Peak height relative standard deviations for 2 × 10−5 and 1 × 10−4 mol l−1 triiodide were ±0.4 and ±1.8%, respectively, and sampling frequency was 80 samples per hour. The method proposed was applied satisfactorily to the iodometric determination of different chlorine-containing disinfectants, among them trichloroisocyanuric acid and dichloroisocyanurate in several types of commercial sample.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号