首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A rapid thermospray liquid chromatography-mass spectrometry (TSP LC-MS) method is described for the simultaneous determination of nicotine and 17 of its metabolites. Chemical ionization of nicotine and its metabolites separated by reversed-phase HPLC is achieved by postcolumn addition of ammonium acetate buffer with the filament of the ion source turned off. Quantification is accomplished by selectively monitoring the unique protonated molecular ion of each metabolite. Trideuterated cotinine serves as an internal standard. Linear responses for cotinine, demethylcotinine, and trans-3'-hydroxycotinine were observed over a concentration range of 20-8000 ng/mL, and 80-8000 ng/ml for nicotine and nicotine-1'-N-oxide. Of the 17 metabolites examined, only nicotine, cotinine, demethylcotinine, and trans-3'-hydroxycotinine were detected in smokers' urine.  相似文献   

2.
A liquid chromatographic-mass spectrometric method for the simultaneous determination of nicotine, cotinine, trans-3'-hydroxycotinine, and norcotinine in human plasma was developed and validated. Analytes and deuterated internal standards were extracted from human plasma using solid-phase extraction and analyzed by liquid chromatography/atmospheric pressure chemical ionization-mass spectrometric detection with selected ion monitoring (SIM). Limits of detection and quantification were 1.0 and 2.5 ng/ml, respectively, for all analytes. Linearity ranged from 2.5 to 500 ng/ml of human plasma using a weighting factor of 1/x; correlation coefficients for the calibration curves were > 0.99. Intra- and inter-assay precision and accuracy were < 15.0%. Recoveries were 108.2-110.8% nicotine, 95.8-108.7% cotinine, 90.5-99.5% trans-3'-hydroxycotinine, and 99.5-109.5% norcotinine. The method was also partially validated in bovine serum, owing to the difficulty of obtaining nicotine-free human plasma for the preparation of calibrators and quality control (QC) samples. This method proved to be robust and accurate for the quantification of nicotine, cotinine, trans-3'-hydroxycotinine, and norcotinine in human plasma collected in clinical studies of acute nicotine effects on brain activity and on the development of neonates of maternal smokers.  相似文献   

3.
An SPE-LC-MS/MS method was developed, validated and applied to the determination of nicotine and five major metabolites in human urine: cotinine, trans-3'-hydroxycotinine, nicotine-N-glucuronide, cotinine-N-glucuronide and trans-3'-hydroxycotinine-O-glucuronide. A 500 microL urine sample was pH-adjusted with phosphate buffer (1.5 mL) containing nicotine-methyl-d3, cotinine-methyl-d3 and trans-3'-hydroxycotinine-methyl-d3 internal standards. For the unconjugated metabolites, an aliquot (800 microL) of the buffered solution was applied to a 30 mg Oasis HLB-SPE column, rinsed with 2% NH4OH/H2O (3.0 mL) and H2O (3.0 mL) and eluted with methanol (500 microL). The eluate was analyzed isocratically (100% methanol) by LC-MS/MS on a diol column (50 x 2.1 mm). For the total metabolites, a beta-glucuronidase/buffer preparation (100 microL) was added to the remaining buffered solution and incubated at 37 degrees C (20 h). An aliquot (800 microL) of the enzymatically treated buffered solution was extracted and analyzed in the same manner. The conjugated metabolites were determined indirectly by subtraction. The quantitation range of the method (ng/mL) was 14-10,320 for nicotine, 15-9800 for cotinine and 32-19,220 for trans-3'-hydroxycotinine. The validated method was used to observe diurnal variations from a smoker's spot urine samples, elimination half-lives from a smoker's 24 h urine samples and metabolite distribution profiles in the spot and 24 h urine samples.  相似文献   

4.
A high-performance liquid chromatographic method with ultraviolet photometric detection has been developed for the quantitation of cotinine and trans-3'-hydroxycotinine in human serum. A solid-phase extraction procedure was performed for the analytes and the internal standard, N-ethylnorcotinine, before chromatography. The use of a 30-cm reversed-phase column and a mobile phase of water-methanol-0.1 M sodium acetate-acetonitrile (67:24.5:6.5:2, v/v), pH 4.3, prevented the co-elution of caffeine with cotinine. The limit of quantitation observed with this method was 5 ng/ml for both cotinine and trans-3'-hydroxycotinine. The present method proved useful for the determination of serum levels of these metabolites, correlating with nicotine daily intake.  相似文献   

5.
A method of vortex‐assisted dispersive liquid–liquid extraction coupled with gas chromatography and tandem mass spectrometry for the determination of nicotine and cotinine in urine was developed. Response surface methodology was applied to obtain the optimum extraction conditions. In this method, Plackett–Burman design was utilized to evaluate the impact of five selected factors on pretreatment procedure. Then, three main factors were optimized using a Box–Behnken design. The optimized method showed good linearities at 1–2000 μg/L with correlation coefficients of 0.9998 for nicotine and 0.9986 for cotinine. Recovery was 91.4–106 and 91.7–108% for nicotine and cotinine, respectively. The intraday relative standard derivations of determination were 1.47–4.06% for nicotine and 0.41–3.16% for cotinine, and interday relative standard derivations were 3.03–6.70% for nicotine and 1.64–6.38% for cotinine. The method detection limits for nicotine and cotinine were 0.33 and 0.34 μg/L, respectively. A total of 87 urine samples from smokers and nonsmokers were tested with the proposed method. Urinary nicotine and cotinine were 23.0–6.67 × 103 and 18.4–4.17 × 103 μg/(g·cr) for smokers and 1.31–286 and 1.39–131 μg/(g·cr) for nonsmokers, respectively. The method is sensitive, suitable and reliable for the determination of nicotine and cotinine in urine and meets the requirements for evaluating short‐term tobacco exposure.  相似文献   

6.
Consumption of nicotine in the form of smokeless tobacco (snus, snuff, chewing tobacco) or nicotine-containing medication (gum, patch) may benefit sport practice. Indeed, use of snus seems to be a growing trend and investigating nicotine consumption amongst professional athletes is of major interest to sport authorities. Thus, a liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the detection and quantification of nicotine and its principal metabolites cotinine, trans-3-hydroxycotinine, nicotine-N'-oxide and cotinine-N-oxide in urine was developed. Sample preparation was performed by liquid-liquid extraction followed by hydrophilic interaction chromatography-tandem mass spectrometry (HILIC-MS/MS) operated in electrospray positive ionization (ESI) mode with selective reaction monitoring (SRM) data acquisition. The method was validated and calibration curves were linear over the selected concentration ranges of 10-10,000 ng/mL for nicotine, cotinine, trans-3-hydroxycotinine and 10-5000 ng/mL for nicotine-N'-oxide and cotinine-N-oxide, with calculated coefficients of determination (R(2)) greater than 0.95. The total extraction efficiency (%) was concentration dependent and ranged between 70.4 and 100.4%. The lower limit of quantification (LLOQ) for all analytes was 10 ng/mL. Repeatability and intermediate precision were ≤9.4 and ≤9.9%, respectively. In order to measure the prevalence of nicotine exposure during the 2009 Ice Hockey World Championships, 72 samples were collected and analyzed after the minimum of 3 months storage period and complete removal of identification means as required by the 2009 International Standards for Laboratories (ISL). Nicotine and/or metabolites were detected in every urine sample, while concentration measurements indicated an exposure within the last 3 days for eight specimens out of ten. Concentrations of nicotine, cotinine, trans-3-hydroxycotinine, nicotine-N'-oxide and cotinine-N-oxide were found to range between 11 and 19,750, 13 and 10,475, 10 and 8217, 11 and 3396, and 13 and 1640 ng/mL, respectively. When proposing conservative concentration limits for nicotine consumption prior and/or during the games (50 ng/mL for nicotine, cotinine and trans-3-hydroxycotinine and 25 ng/mL for nicotine-N'-oxide and cotinine-N-oxide), about half of the hockey players were qualified as consumers. These findings significantly support the likelihood of extensive smokeless nicotine consumption. However, since such conclusions can only be hypothesized, the potential use of smokeless tobacco as a doping agent in ice hockey requires further investigation.  相似文献   

7.
《Analytical letters》2012,45(8):1217-1233
The measurement of the primary nicotine metabolites, cotinine and trans-3′-hydroxycotinine, is a useful biomarker of nicotine exposure and metabolism genetics for smoking cessation research. Herein is described an ultra-high performance liquid chromatography–tandem mass spectrometry method for the determination of these primary nicotine metabolites in urine. Urine samples were diluted one hundred-fold with water and introduced into an ultra-high performance liquid chromatography triple quadrupole mass spectrometer using positive ion electrospray ionization with multiple reaction monitoring. Levels of urinary nicotine metabolites: cotinine, trans-3′-hydroxycotinine, and their respective glucuronides were determined directly using deuterated internal standards and compared with indirect determination by enzymatic hydrolysis. The assay was applied to a community sample of smokers’ urine (n = 280). The assay demonstrated satisfactory performance (relative standard deviation of 1.6–6.5 percent at the 1000 nanograms per milliliter level and >98 percent recovery) suitable for application to smoking studies with a run time less than five minutes. The mean (min-max) levels of cotinine and cotinine-glucuronide were 968 (31-3831) and 976 (9-5607) nanograms per milliliter. The mean (min-max) levels of trans-3′-hydroxycotinine and trans-3′-hydroxycotinine-glucuronide were 3529 (13-21337) and 722 (0-4633) nanograms per milliliter. Direct determination of glucuronide metabolites was superior to indirect measurement using enzymatic hydrolysis, where there was evidence of loss of metabolites during sample preparation. A sensitive and selective ultra-high performance liquid chromatography–tandem mass spectrometry assay was successfully developed for the determination of cotinine, trans-3′-hydroxycotinine, and their glucuronides in urine. The rapid and simple sample preparation makes this assay suitable for high throughput studies involving nicotine metabolism phenotype for both cytochrome P450 2A6 and uridine 5′-diphospho-glucuronosyltransferase, smoking prevalence, and cessation studies.  相似文献   

8.
The nicotine metabolites, cotinine and trans-3′-hydroxycotinine (3HC) are considered as superior biomarkers for identifying tobacco exposure. More importantly, the ratio of 3HC to cotinine is a good indicator to phenotype individuals for cytochrome P450 2A6 activity and to individualize pharmacotherapy for tobacco addiction. In this paper, a simple, robust and novel method based on surface-enhanced Raman spectroscopy coupled with thin-layer chromatography (TLC) was developed to directly quantify the biomarkers in human urine samples. This is the first time surface-enhanced Raman spectroscopy (SERS) was used to detect cotinine and 3HC in urine samples. The linear dynamic range for the detection of cotinine is from 40 nM to 8 μM while that of 3HC is from 1 μM to 15 μM. The detection limits are 10 nM and 0.2 μM for cotinine and 3HC, respectively. The proposed method was further validated by quantifying the concentration of both cotinine and 3HC in smokers’ urine samples. This TLC-SERS method allows the direct detection of cotinine in the urine samples of both active and passive smokers and the detection of 3HC in smokers.
Figure
Scheme of the procedure for detection of cotinine and 3HC  相似文献   

9.
A liquid chromatographic mass spectrometric (LC-MS) assay for the quantification of nicotine and cotinine in human specimens was developed. Human serum and urine (100 μL) were subjected to liquid-liquid extraction. For glucuronidated cotinine, serum was alkalinized and hydrolyzed before extraction. The dried samples were reconstituted and run using gradient flow reverse-phase liquid chromatography with MS detection. The ions utilized for quantification of nicotine, cotinine and milrinone (internal standard) were 162.8, 176.9 and 211.9 m/z, respectively. The mean recoveries were over 80% for cotinine and nicotine with excellent linearity between nominal concentrations and peak area ratios, over a wide concentration range. The percentage coefficient of variation and mean error of the inter- and intra-day validations were <15% for nicotine and cotinine. Analysis of serum from cardiac patients receiving amiodarone suggested that a number of patients were either active smokers or exposed to second-hand smoke. Significant concentrations of nicotine and cotinine were measured in the urine of a known smoking volunteer. The method was highly specific, sensitive and applicable as a tool in detecting and monitoring the passive exposure to tobacco smoke using small specimen volumes (0.1 mL).  相似文献   

10.
A rapid, highly specific and sensitive isotope-dilution liquid chromatography/tandem mass spectrometry (LC/MS/MS) method coupled with an on-line solid-phase extraction (SPE) system was developed to measure N7-methylguanine (N7-MeG) in urine. 15N5-Labeled N7-MeG was synthesized to serve as an internal standard, and an on-line SPE cartridge was used for on-line sample cleanup and enrichment. The urine sample can be directly analyzed within 15 min without prior sample purification. The detection limit for this method was estimated as 8.0 pg/mL (4.8 pmol) on-column. This method was further applied to study exposure to methylating agents arising from cigarette smoke. Sixty-seven volunteers were recruited, including 32 regular smokers and 35 nonsmokers. Urinary cotinine, a major metabolite of nicotine, was also determined using an isotope-dilution LC/MS/MS method. The results showed that urinary levels of N7-MeG observed in smokers (4215 +/- 1739 ng/mg creatinine) were significantly (P < 0.01) higher than those in nonsmokers (3035 +/- 720 ng/mg creatinine). It was further noted that the urinary level of N7-MeG was found to be correlated with that of cotinine for smokers, implying that cigarette smoking resulted in increased DNA methylation, followed by depurination and excretion of N7-MeG in urine. As a result of the on-line extraction system, this method is capable of routine high-throughput analysis and accurate quantitation of N7-MeG, and could be a useful tool for health surveillance of methylating agent exposure.  相似文献   

11.
Improved methods have been developed for the determination of nicotine and its major metabolite, cotinine, in blood, plasma, and urine samples. These methods utilize gas chromatography with alkali flame ionization (nitrogen--phosphorus) detection and structural analogs of nicotine and cotinine as internal standards.  相似文献   

12.
A procedure based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) is described for the determination of nicotine and its principal metabolites cotinine, trans-3-hydroxycotinine and cotinine-N-oxide, caffeine and arecoline in breast milk, using N-ethylnorcotinine as internal standard. Liquid/liquid extraction with chloroform/isopropanol (95:5, v/v) was used for nicotine, cotinine, trans-3-hydroxycotinine, cotinine-N-oxide and caffeine under neutral conditions and for arecoline under basic conditions. Chromatography was performed on a C(8) reversed-phase column using a gradient of 50 mM ammonium formate, pH 5.0, and acetonitrile as a mobile phase at a flow rate of 0.5 mL/min. Separated analytes were determined by electrospray ionization tandem mass spectrometry in the positive ion mode using multiple reaction monitoring. Limits of quantification were 5 microg/L for nicotine, cotinine, trans-3-hydroxycotinine, cotinine-N-oxide and caffeine, and 50 microg/L for arecoline using 1 mL human milk per assay. Calibration curves were linear over the calibration ranges for all the substances under investigation, with a minimum r(2) > 0.998. At three concentrations spanning the linear dynamic range of the assay, mean recoveries from breast milk ranged between 71.8 and 77.4% for different analytes. This method was applied to the analysis of analytes in human milk to assess substance exposure in breast-fed infants in relation to eventual clinical outcomes. This LC/MS/MS assay provides adequate sensitivity and performance characteristics for the simultaneous quantification of biomarkers of three of the drugs most commonly used worldwide (tobacco, caffeine and areca nut).  相似文献   

13.
Cotinine, the main metabolite of nicotine in human body, is widely used as a biomarker for assessment of direct or passive exposure to tobacco smoke. A method for molecularly imprinted solid-phase extraction (MISPE) of cotinine from human urine has been investigated. The molecularly imprinted polymer (MIP) with good selectivity and affinity for cotinine was synthesized using cotinine as the template molecule, methacrylic acid as the functional monomer, and ethylene glycol dimethacrylate as the cross-linker. The imprinted polymer was evaluated for use as a SPE sorbent, in tests with aqueous standards, by comparing recovery data obtained using the imprinted form of the polymer and a non-imprinted form (NIP). Extraction from the aqueous solutions resulted in more than 80% recovery. A range of linearity for cotinine between 0.05 and 5 μg mL−1 was obtained by loading 1 mL blank urine samples spiked with cotinine at different concentrations in acetate buffer of pH 9.0, and by using double basic washing and acidic elution. The intra-day coefficient of variation (CV) was below 7% and inter-day CV was below 10%. This investigation has provided a reliable MISPE–HPLC method for determination of cotinine in human urine from both active smokers and passive smokers. Figure  相似文献   

14.
李明昕  王倩  朱婧  任琳  雍莉  邹晓莉 《色谱》2017,35(8):826-831
建立了测定人尿液中尼古丁和可替宁含量的亲水作用色谱-串联质谱(HILIC-MS/MS)方法。尿样加入尼古丁-d4和可替宁-d3同位素内标后,用水稀释10倍,经过滤后的滤液由超高效液相色谱-串联质谱(UPLC-MS/MS)进行分离分析。采用ACQUITY UPLC~BEH HILIC色谱柱(50 mm×3.0 mm,1.7μm),以甲醇和体积分数为0.1%的氨水为流动相,流速为0.2 mL/min,在电喷雾电离源正离子模式下测定尿液中尼古丁和可替宁的含量,用标准曲线法定量。尼古丁和可替宁在1.0~1 000μg/L范围内线性关系良好,相关系数分别为0.994 9和0.995 8;检出限分别为0.082μg/L和0.077μg/L;定量限分别为0.27μg/L和0.26μg/L;加标回收率分别为90.4%~103.5%和93.0%~104.6%;相对标准偏差分别为4.80%~6.21%和4.22%~7.15%。应用所建立的方法测定了200份尿样,结果表明,吸烟人群尿中尼古丁含量为26.68~854.30μg/L,可替宁含量为36.66~1 191.18μg/L(n=86,M_(nicotine)=76.00μg/L,M_(nicotine)=83.52μg/L,M为中位数);非吸烟人群尿中尼古丁含量为5.08~69.66μg/L,可替宁含量为3.16~28.21μg/L(n=114,Mnicotine=7.53μg/L,M_(nicotine)=3.79μg/L)。该方法快速灵敏,操作简单,适用于尿样中尼古丁和可替宁的批量测定,能满足烟草暴露评价的需要。  相似文献   

15.
Nicotine is the primary psychoactive component in tobacco. It is taken into the body by tobacco smoking, and mainly metabolized to cotinine in the hepatic cytochrme P450 (CYP) 2A6. The objective of this study was to develop a sensitive method for the determination of nicotine metabolism to cotinine using HPLC. The internal standard, trans-4'-carboxycotinine methyl ester was synthesized with a simple method. The nicotine and cotinine were separated completely and detected by C(18) 5-μm analytical column (L-column Octa decyl silyl (ODS), 150 mm × 4.6 mm i.d.) equipped with a C(18) 5-μm guard column (L-column ODS, 10 mm × 4.6 mm i.d.) and ultraviolet detection at 260 nm. The detection limit of the assay was 0.05 μM for cotinine (n=5, R.S.D) and 0.1 μM for nicotine. Thus the present results provided a sensitive and useful method for the determination of nicotine metabolism catalyzed by CYP2A6.  相似文献   

16.
A screening method has been developed for the determination of 23 organochlorine pesticides (OCPs) and 3-pyrethroid metabolities [cis- and trans-3-(2,2-dichlorovinyl)-2,2-dimethyl-(1-cyclopropane) carboxylic acid, cis-3-(2,2-dibromovinyl)-2,2-dimethyl-(1-cyclopropane) carboxylic acid and 3-phenoxybenzoic acid] from human urine. OCPs were directly detected in urine samples while pyrethroid metabolites required acid-induced hydrolysis to convert their conjugates into free acids; all compounds were then cleaned-up/preconcentrated using solid phase extraction. Determination and quantitation was achieved by gas chromatography with a mass spectrometer detector operating in selected ion monitoring mode. Limits of detection varied between 0.1 and 0.3 ng/mL with linear ranges from 0.3 to 700 ng/mL; the precision of the method was high (4.3-7.2%). Recoveries of all analytes from urine samples fortified at levels of 30 ng/mL for each OCP and 15 ng/mL for each pyrethroid metabolite ranged from 88 to 101% (captan gave the lowest recovery). The results obtained from the analysis of real urine samples show the suitability of the proposed method for monitoring people exposed to organochlorine and pyrethroid pesticides.  相似文献   

17.
The determination of nicotine and cotinine in plasma   总被引:2,自引:0,他引:2  
A method to determine plasma nicotine and cotinine simultaneously is described. After a simple extraction procedure, the amounts of nicotine and cotinine present in a sample are determined by gas chromatography using nitrogen-sensitive detection and a fused silica capillary column. The method has been demonstrated to detect nicotine and cotinine plasma concentrations within 1 and 9 ng/ml, respectively. The accuracy and precision of the method was demonstrated using spiked calf and human sera. Data are presented for the direct comparison of the present method with other methods of determination for plasma nicotine and cotinine.  相似文献   

18.
A polarization fluoroimmunoassay for cotinine, a major metabolite of nicotine, has been adapted for fully automated screening of urine samples on the Abbott TDx analyser. The method has sensitivity and specificity suitable for the discrimination of active smokers from non-smokers (including passive smokers) by application of a cut-off at 0.5 mg l-1 of total urinary cotinine. Most active smokers' urine gave results over 1 mg l-1, whereas apparent levels in non-smokers were 0.08 mg l-1 or lower. A result for one sample can be obtained in about 5 min and a throughput of 80 samples h-1 can be maintained for large-scale screening applications.  相似文献   

19.
This study reports on the development of a rapid and simple method for the determination of the antinerve agent drug pyridostigmine bromide (3-dimethylaminocarbonyloxy-N-methyl pyridinium bromide) (PB), its metabolite N-methyl-3-hydroxypyridinium bromide, nicotine (S-1-methyl-5-(3-pyridyl)-2-pyrrolidine), and its metabolites nornicotine (2-(3-pyridyl)pyrrolidine) and cotinine (S-1-methyl-5-(3-pyridyl)-2-pyrrolidone) in rat plasma and urine. The compounds are extracted and eluted by methanol and acetonitrile using C18 Sep-Pak cartridges and separated using high-performance liquid chromatography by a gradient of methanol, acetonitrile, and water (pH 3.2) at a flow rate of 0.8 mL/min in a period of 14 min. UV detection was at 260 nm for nicotine and its metabolites and at 280 nm for PB and its metabolite. The limits of detection ranged between 20 and 70 ng/mL, and the limits of quantitation were 50-100 ng/mL. The average percent recovery of five spiked plasma samples were 85.7 +/- 7.3%, 80.4 +/- 5.8%, 78.9 +/- 5.4%, 76.7 +/- 6.4%, and 79.7 +/- 5.7% and for urine were 85.9 +/- 5.9%, 75.5 +/- 6.9%, 82.6 +/- 7.9%, 73.6 +/- 5.9%, and 77.7 +/- 6.3% for nicotine, nornicotine, cotinine, PB, and N-methyl-3-hydroxypyridinium bromide, respectively. The calibration curves for standard solutions of the compounds of peak areas and concentration are linear for a range between 100 and 1,000 ng/mL. This method is applied in order to analyze the previously mentioned chemicals and metabolites following their oral administration in rats.  相似文献   

20.
Toraño JS  van Kan HJ 《The Analyst》2003,128(7):838-843
A method using gas chromatography (GC)-mass spectrometry (MS) for the simultaneous determination of the smoke uptake parameters thiocyanate, nicotine and cotinine in human tissues is reported. Nicotine, cotinine and thiocyanate, in combination with a phase-transfer catalyst, were extracted from urine, saliva and hair into dichloromethane (DCM). Thiocyanate was alkylated in the DCM-layer to form a pentafluorobenzyl derivative. The biochemical markers in DCM were directly injected into the GC system and separated on a DB-1MS column using a 9.4 min temperature program. The method was validated in urine and saliva between the limits of quantitation (1.0-15 microg ml(-1) thiocyanate, 0.010-3.0 microg ml(-1) nicotine and cotinine in urine, 0.010-1.0 microg ml(-1) nicotine and cotinine in saliva). The calibration curves were found to be linear (r > 0.996), the within- and between-day accuracy's were 83-120%, the repeatability coefficients of variation were 3-20% and the limits of detection were 0.060 ng ml(-1) thiocyanate and 0.60 ng ml(-1) nicotine and cotinine. The results of the analysis of the biomarkers in the urine of 44 volunteers were used to develop a predictive model for smoking status, using discriminant analysis. The classification model correctly classified 93.2% of cross-validated grouped cases. Saliva samples were used to confirm the results of the classification method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号