L. Molina-García 《Talanta》2009,79(3):627-632
Disodium cromoglycate (SCG) is an anti-allergic drug, which is applied locally or inhaled. After administration, a very small portion of the drug is absorbed, being the most eliminated part unchanged in the urine and bile; therefore, its determination in urine is indicative of the dose absorbed. Here, the first spectroscopic method for the determination of SCG, making use of a sequential injection optosensor with terbium-sensitized luminescence detection, is described. The cationic resin Chelex-100 was used as solid support in the detection area. The measurements were made at 336/545 nm (λex/λem) and the system was calibrated for two sample volumes, 150 and 800 μl, depending on the samples analyzed. A detection limit of 15 ng ml−1 and a RSD lower than 2% (n = 10) were observed using the highest sample volume. The proposed method does not use any organic solvent or surfactant, so being environmental friendly. The analyte was satisfactorily determined in pharmaceuticals and human urine, the latter being spiked at the concentrations found after the administration of the drug.  相似文献   

2.
The principle of sequential injection (SI) was exploited to develop a fully automated pre-column derivatization procedure combined on-line to liquid chromatography (LC). Using SI-LC derivatization 14 amino acids were determined fluorimetrically in pharmaceuticals with o-phthaldialdehyde (OPA) as the derivatization reagent. The SI system was used for the handling of samples and reagents, on-line mixing and introduction to the LC injection system. Chemical (pH and reagents concentrations) and instrumental variables (sample and reagent volumes, reaction time and flow rate) were optimized to attain the highest reaction yield and detector signal. Reversed phase chromatographic resolution of 14 amino acids was achieved within 35 min using gradient elution. The automated operation of the coupled SI-LC system resulted in very satisfactory performance. The method was applied for the simultaneous determination of amino acids in pharmaceutical formulations.  相似文献   

3.
An amperometric immunosensor based on graphite paste (graphite powder and paraffin oil) has been constructed for the assay of azidothymidine (AZT). The graphite paste is impregnated with anti-AZT. The immunosensor can be reliably used for the assay of AZT in its pharmaceutical formulation. The potential used for AZT assay was 435 mV vs Ag/AgCl electrode. The surface of the immunosensor can be regenerated by simply polishing, obtaining fresh immunocomposite ready to be used in a new assay. Due to its reliability, the immunosensor was successfully used as a detector in a sequential injection analysis system, and gave reliable results for on-line assay of AZT purity in raw material and AZT contents in pharmaceutical formulations.  相似文献   

4.
A sequential injection analysis (SIA) using lab-on-valve with air segmentation and spectrophotometric detection was designed for copper(II) determination. It is based on the reaction of copper(II) and 2-carboxy-2′-hydroxy-5′-sulfoformazyl benzene (Zincon) in a weak alkaline solution between the air zones. Beer's Law was obeyed over the range of 0.1-2.0 mg L−1 copper(II) with a correlation coefficient 0.9985 and a slope of 0.2893 absorbance unit/mg L−1. The relative standard deviation was 2.0% for a series of 10 measurements of 0.5 mg L−1 copper(II) solution. The detection limit (3 S/N) and the limit of quantification (LOQ) were 0.05 and 0.17 mg L−1 respectively. This method has been successfully applied to determination of copper(II) in wastewater with a sample throughput of 120 h−1. The method is superior to the batchwise method in that it provides fully automation, rapidity, less reagents and sample consumption with little waste generation.  相似文献   

5.
Frank C  Schroeder F  Ebinghaus R  Ruck W 《Talanta》2006,70(3):513-517
A sequential injection analysis system (SIA) is described which is suited for the fast determination of filterable molybdate reactive phosphate (FRP, 0.2 μm) in coastal waters. It processes up to 270 samples per hour with a detection limit (3σ) of 0.05 μM and is used for surface mapping of phosphate in areas with steep concentration gradients like the Wadden Sea. The determination is based on the reaction of phosphate with acidic molybdate to phosphomolybdate, which builds non-fluorescent ion pairs with rhodamine 6G. The remaining rhodamine fluorescence is detected at 550 nm with an excitation at 470 nm. Syringe pump, valve and detector were controlled by a self made python programme, which was optimised for high speed SIA measurements in monitoring applications.  相似文献   

6.
A simple, specific and sensitive sequential injection analysis (SIA) system based on non-immunoassay fluorescent detection has been developed for the determination of urinary albumin. The specific binding of the dye Albumin Blue 580 (AB 580) to albumin in urine generated high emission fluorescent signals. The excitation and emission wavelengths were set at 590 and 610 nm, respectively. The analytical range was obtained from 1 to 100 mg L−1, with a detection limit of 0.3 mg L−1 (S/N = 3). The SIA system gave high precision with relative standard deviations (R.S.D.s) of 0.9% and 1.4% when evaluated with 15 and 100 mg L−1 albumin (n = 15), respectively. The method exhibited good reproducibility, as assessed by performing four analytical curves on different days, and intra-run CVs (2.3-3.3%) and inter-run CVs (3.8%) were obtained. Rapid operation was achieved with a sample throughput of 37 h−1. This method was successfully applied to the determination of urinary albumin, and the method was highly correlated with the immunoturbidimetric method (r2 = 0.965; n = 72).  相似文献   

7.
Two new flow methods, flow injection analysis (FIA) and sequential injection analysis (SIA), for the spectrophotometric determination of Cu(II) in water at trace levels have been developed and optimised. Both methods are based on the reaction with oxalic acid bis(cyclohexylidene hydrazide) (cuprizone) in alkaline media. The two procedures have been developed for the final aim to compare their performances and to offer new rapid heavy metals analysis tools, avoiding the use of extraction steps. A detailed study of the physico-chemical parameters affecting the systems performances has been carried out. The reversed FIA and sandwich SIA approaches offered the best sensitivity. In both cases, an extremely good linearity has been obtained within the range 0.06-4 μg ml−1 (correlation coefficient r=0.9999), whereas the observed detection limits were 0.013 and 0.004 μg ml−1, for FIA and SIA, respectively. Furthermore, due to the great similarity of the diffusion zones in the reaction slugs, our approach offers the opportunity to compare the two methods in analogous conditions. This SIA method, besides keeping its typical reagent saving features, offered analytical performances equivalent to those of FIA. To obtain these results, an original “stop-flow like” method was successfully employed in the SIA approach. Both methods were validated by analysis of real water samples, after copper addition, and certified reference samples of fortified and waste waters.  相似文献   

8.
A selective procedure for the determination of Al3+ in drinking and natural waters is proposed. The analytical procedure is based both on the complex formation between Al3+ and 8-hydroxyquinoline-5-sulfonic acid (HQS) and on a fluorimetric detection of the complex. The reaction was carried out in presence of thioglycolic acid as a masking agent. This procedure has been adapted to a sequential injection analysis (SIA) system. Operative conditions both for batch and SIA procedures were investigated including reagent concentration, volumes, pH and wavelengths used for the fluorimetric detection. Batch procedure allows determination of Al3+ at ppb level (LOQ: 2.8 μg l−1) within a working range of 2.2-300 μg l−1. The SIA procedure was successfully employed for the determination of Al3+ in several commercial drinking and tap waters.  相似文献   

9.
在磷酸介质中 ,甲醛可以催化溴酸钾氧化 花青的反应使其退色 ,据此建立了顺序注射催化动力学光度法测定织物和室内空气中痕量甲醛的新方法。方法的线性范围 0 .5~ 7.0 μg mL ,检出限 0 .1 μg mL。用于树脂整理特殊织物和室内空气中痕量甲醛的测定 ,回收率在 97.0 %~ 1 0 5 .0 %之间。  相似文献   

10.
The present work describes a sequential injection analysis (SIA) system adapted to direct analysis of oil samples. In this way, the flow system was designed by incorporation, in the SIA system, of an injection valve that was responsible for the sample insertion. With the developed sampling strategy the sample pre-treatment outside the flow system is avoided and also the problems associated with viscous samples in flow systems.The developed SIA system was applied to the determination of iron (Fe(III)) in edible oil samples and was based on the formation of a red complex (λ = 510 nm) between Fe(III) and thiocyanate in organic medium. A mixture of methanol:chloroform (85:15) was used as carrier solution and possible refractive index associated with the spectrophotometric detection was avoided by introduction of a mixing chamber in the flow system. The presented methodology produced 4.2 ml of effluent and consumed 150 μl of sample and 0.95 mg of thiocyanate per determination.Linear calibration plots were obtained for Fe(III) concentrations up to 25 mg l−1 and the detection limit of the determination was 0.31 mg l−1. The developed methodology exhibited a good precision, with an R.S.D. < 3.5% (n = 15) and a determination frequency of 20 determinations h−1. The results of the analysis were evaluated by recovery studies (96.5-104.5%) and by the analysis of two AOCS reference samples.  相似文献   

11.
A sequential injection analysis (SIA) method for the at-line determination of formaldehyde in a cultivation process of Pichia pastoris is presented. A genetically modified yeast strain was used for cultivation processes wherein methanol feed induced the production of the recombinant protein 1-3del I-TAC. Recurring measurements of culture medium, its blank and including standard addition were performed with Nash reagent using an automated syringe device and photometric detection. The apparatus was coupled via a laboratory-made flow-through adapter to a continuous filtered and cell-medium flow from the bioreactor. At-line monitoring of formaldehyde was performed at two cultivations, each of 250 h during fed-batch phases with glycerol and methanol as carbon sources. High reliability, robustness and reproducibility of the method, the software and the instrumentation as well as the high selectivity of the reaction were demonstrated.  相似文献   

12.
A sequential injection system with spectrophotometric detection was proposed for the determination of copper, zinc and lead in brass. In view of the high analyte concentrations and the sensitivity of the involved catalytic methods, optimization of the flow system was carried out aiming mild reaction conditions. Copper and lead determinations were based on the catalytic effects of Cu2+ and Pb2+ on the oxidation rates of resorcinol and pyrogallol red by H2O2, respectively, and zinc determination involved precipitate formation after oxidation of 1-nafthylethylenediamine by K3Fe(CN)6. The analytical procedures were designed with some common parameters such as pH=9.0 (borate system), λ=530 nm, and H2O2 as oxidizing agent; system geometry was maintained.The proposed system is rugged, and base line drift is not observed during 4 h operation periods. Twenty samples are run per hour (60 determinations) and reagent consumption is minimal, thus avoiding drawbacks related to waste management. Precise results (R.S.D.<1.0%; n=7) are obtained and a detection limit of 1% (w/w) was estimated for the three analytes. Results were in agreement with flame atomic absorption spectrometry.  相似文献   

13.
A review on sequential injection methods for water analysis   总被引:1,自引:0,他引:1  
The development of fast, automatic and less expensive methods of analysis has always been the main aim of flow methodologies. The search for new procedures that still maintain the reliability and accuracy of the reference procedures is an ever growing challenge. New requirements are continually added to analytical methodologies, such as lower consumption of samples and reagents, miniaturisation and portability of the equipment, computer interfaces for full decision systems and so on. Therefore, the development of flow methodologies meeting the extra requirements of water analysis is a challenging work.Sequential injection analysis (SIA) presents a set of characteristics that make it highly suitable for water analysis. With sequential injection analysis, most routine determinations in waters can be performed more quickly with much lower reagent consumption when compared to reference procedures. Additionally, SIA can be a valuable tool for analyte speciation and multiparametric analysis. This paper critically reviews the overall work in this area.  相似文献   

14.
The limits of detection (3s) for ascorbic acid were 5×10−8 M with acidic potassium permanganate using both flow injection analysis (FIA) and sequential injection analysis (SIA) whereas the soluble manganese(IV) afforded 1×10−8 M and 5×10−9 M for FIA and SIA, respectively. Determinations of ascorbic acid in Vitamin C tablets were achieved with minimal sample pretreatment using a standard additions calibration and gave good agreement with those of iodimetric titration.  相似文献   

15.
J. F. van Staden  A. Botha 《Talanta》1999,49(5):1154-1108
A sequential injection system, based on the reaction of Cu(II) with diethyldithiocarbamate (DDTC), was developed for the determination of Cu(II) in plant food and water samples. The extraction procedure, generally used to extract the Cu(II)–DDTC complex for subsequent analysis was eliminated in this procedure. The complex was detected spectrophotometrically in aqueous solutions at 460 nm. The physical and chemical parameters depicting the system were studied to obtain optimum conditions for sample analysis. The system developed is fully computerized and able to monitor Cu(II) in samples at seven samples per hour with a relative standard deviation of <4.50%. The calibration curve is linear from 0.5–5.0 mg/l with a detection limit of 0.2 mg/l. Interferences were reduced by introducing multiple flow reversals, to increase mixing between the reagent and sample zones, and subsequently enhance working of the masking agents (EDTA/citrate).  相似文献   

16.
A method that combines sequential injection analysis (SIA), flow injection analysis and chemiluminescence (CL) detection was developed for the quasi-simultaneous determination of antioxidative activities against superoxide anion and nitric oxide (NO). The antioxidative activity was expressed as the decrease in luminol CL intensity caused by the quenching of or NO by an antioxidant. The SIA system consisted of two syringe pumps, two selection valves, two holding coils, an HPLC pump to deliver luminol solution, and a CL detector. Operation of the syringe pumps and multiport valves was controlled automatically using a personal computer with appropriate software. A hypoxanthine (HX)-xanthine oxidase (XOD) system was used for the generation of , and (±)-(E)-4-methyl-2-[(E)-hydroxyimino]-5-nitro-6-methoxy-3-hexenamide (NOR1) was employed as NO donor agent. The repeatability of the method was evaluated with 35.2 μg ml−1 L-ascorbic acid, and the relative standard deviations (RSD) of the antioxidative activities were less than 3.8%. The quasi-simultaneous determination of the antioxidative activities in one sample was completed within 2.0 min. The antioxidative activities of some antioxidants and commercially available supplements containing certain antioxidants were successfully determined using this system. The proposed system is rapid and reproducible, and thus may be useful for the screening of functional foods, supplements and pharmaceutical formulations that exhibit antioxidative activity. Figure The system that utilizes a combination of SIA and FIA with CL for the quasi-simultaneous determination of antioxidative activity against a NO and b . SP1, 2: syringe pump, HC1, 2: holding coil, MV1, 2: multi-port valve, P: pump, D: chemiluminescence detector, I: integrator, M1, 2: mixing tee, NOR1: (±)-(E)-4-methyl-2-[(E)- hydroxyimino]-5-nitro-6-methoxy-3-hexenamide, HX: hypoxanthine, XOD: xanthine oxidase.  相似文献   

17.
Polásek M  Jambor M 《Talanta》2002,58(6):1253-1261
Antibacterial drug trimethoprim [2,4-diamino-5-(3,4,5-trimethoxybenzyl)-pyrimidine] (I) was determined in pharmaceutical formulations by using a lab-made PC-controlled SIA analyser linked to conventional HPLC fluorimetric detector equipped with a chemiluminescence module. The chemical principle is the oxidation of I by KMnO(4) in acid medium; the reaction is accompanied by the emission of chemiluminescence, which is enhanced in the presence of hexametaphosphate (HMP). The optimum sequence and the flow parameters and concentrations and volumes of reagents aspirated optimised by a computer-aided simplex method were, 100 mul of 5 mM HMP, 40 mul of a test solution of I, 2 mul of 0.5 M H(2)SO(4) and 20 mul of 1 mM KMnO(4); the luminescing zone was pushed into the detector at a flow rate of 49 mul s(-1). The calibration graph relating the intensity of luminescence to concentration of I was parabolic (r=0.9994) in the range 0.5-100 mug ml(-1) of I with rectilinear part (r=0.9999) in the range 20-100 mug ml(-1) of I; the limit of detection was 0.1 mug ml(-1) of I. The method was used for the assay of Triprim(R) tablets (with nominal content 100 or 200 mg of I) for the active substance as well as for content uniformity tests; the R.S.D. values did not exceed 1% (n=5). The SIA results did not show statistical difference from those obtained by pharmacopoeial acidimetric titration in non-aqueous medium; the excipients such as microcrystalline cellulose, maze starch, povidone, talc, magnesium stearate and gelatin did not interfere.  相似文献   

18.
Kullberg N  Vilén M  Sund P  Talaslahti M  Sara R 《Talanta》1999,49(5):234-968
A number of sequential injection analysis (SIA) measurement methods have been developed during the last years. Almost all have been used in laboratory conditions with good results, but very few have been implemented as on-line methods, applied to non-stop measurements, producing immediate results for process control. The transfer of an SIA system from laboratory to an industrial facility [J. Ruzicka, Anal. Chim. Acta 261 (1992) 3] requires a whole new range of details to be taken into account. Some SIA platform related topics will be discussed. There are numerous ways of building an SIA system that meets the needs of the industry. One alternative, SIAmate, is presented.  相似文献   

19.
Sequential injection analysis (SIA) with lab-at-valve (LAV) approach for on-line liquid-liquid micro-extraction has been exploited. Sample, reagent and organic solvent were sequentially aspirated into a coil attached to a central port of a conventional multiposition selection valve, where the extraction process was performed. The aqueous and organic phases were separated in a conical separating chamber LAV unit attached at one port of the valve. The organic phase containing extracted product was then monitored spectrophotometrically. The system offers a novel alternative on-line automated extraction in a micro-scale and has been successfully demonstrated for the assays of diphenhydramine hydrochloride (DPHH) in pharmaceutical preparations and anionic surfactant in water samples.  相似文献   

20.
An automatic sequential injection system, combining monosegmented flow analysis, sequential injection analysis and sequential injection titration is proposed for acidity determination. The system enables controllable sample dilution and generation of standards of required concentration in a monosegmented sequential injection manner, sequential injection titration of the prepared solutions, data collecting, and handling. It has been tested on spectrophotometric determination of acetic, citric and phosphoric acids with sodium hydroxide used as a titrant and phenolphthalein or thymolphthalein (in the case of phosphoric acid determination) as indicators. Accuracy better than |4.4|% (RE) and repeatability better than 2.9% (RSD) have been obtained. It has been applied to the determination of total acidity in vinegars and various soft drinks. The system provides low sample (less than 0.3 mL) consumption. On average, analysis of a sample takes several minutes.  相似文献   