首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A sulphur dioxide probe is utilised as a sensor in an automated, continuous-flow system for the determination of glucose oxidase. The analytical method is based on a coupled indicator reaction scheme in which the product of the enzymatic reaction (hydrogen peroxide) oxidises hydrogensulphite ions. The change in concentration of hydrogen-sulphite is then measured with the SO2 probe. The method is shown to be sufficiently sensitive to detect 0.01 IU ml-1 of the enzyme with few interference problems at sampling rates of up to 90 samples per hour.  相似文献   

2.
《Analytical letters》2012,45(11-12):2403-2411
Abstract

The modification of the surface of a platinum electrode by coating with a layer of a lipid mixture (asolectin), allows the relative measurement of hydrogen peroxide in the presence of interfering analytes. The lipid-enzyme complex and the platinum amperometric sensor offer greater selectivity and extended stability of the resulting probe. Measurements of glucose with the glucose oxidase enzyme and detection of the liberated hydrogen peroxide have been performed as a model system. Linear response of the signal versus glucose concentration was observed in the range of glucose concentration 1.10?3 ? 1.10?5 M with a response time of 20 s. The interferences of ascorbic acid, uric acid, iron (II), paracetamol, tyrosine and glutathion can be drastically minimized by appropriate adjustment of the amount of lipid contained in the biocatalyst layer.  相似文献   

3.
L-酒石酸和一水柠檬酸为混合碳源,以乙二胺为氮源和聚合试剂,并添加六水三氯化铁,通过一锅溶剂热法合成了氮、铁共掺杂碳纳米粒子(N/Fe-CNPs),采用制备的N/Fe-CNPs模拟过氧化物酶催化过氧化氢(H2O2)氧化3,3',5,5'-四甲基 产生可溶性的蓝色产物,联合葡萄糖氧化酶建立了测定H2O2和葡萄糖含量的新方法。 结果显示:H2O2及葡萄糖的浓度与反应体系的吸光度呈良好的线性关系,H2O2的线性范围为0.2~20 μmol/L,葡萄糖的线性范围为0.1~1.0及1.0~80 μmol/L,最低检出限分别可达42.5和76.1 nmol/L。  相似文献   

4.
The performance and analytical characteristics of a glassy carbon glutaraldehyde immobilized glucose oxidase electrode have been established with regard to the direct detection of hydrogen peroxide produced from the reaction of glucose with oxygen. Measurements were performed at + 1.1 V vs. SCE, and selectivity was obtained by casting the surface with a cellulose acetate membrane. Results compared favorably with the classical platinum-enzyme probe. The mechanism of ascorbic acid interference in hydrogen peroxide detection is reported. Mediated detection was also investigated for oxidase enzymes (glucose oxidase and xanthine oxidase) immobilized on the bare glassy carbon electrode. The probes were characterized using a specific enzyme mediator in solution (phenazine methosulfate or dichlorophenol-indophenol) plus hexacyanoferrate(III) as an electrochemical mediator. The electrode was poised at + 0.36 V vs. SCE for the detection of hexacyanoferrate(II). The advantages of this dual mediator configuration include high stability and sensitivity of the electrochemical signal and the ability to use less positive potentials for increased selectivity. Application to other enzymes, such as hydrogenases, using such a binary redox configuration is suggested.  相似文献   

5.
The performance of carbon nanotubes paste electrodes (CNTPE) prepared by dispersion of multi-wall carbon nanotubes (MWNT) within mineral oil is described. The resulting electrode shows an excellent electrocatalytic activity toward ascorbic acid, uric acid, dopamine, 3,4-dihydroxyphenylacetic acid (dopac) and hydrogen peroxide. These properties permit an important decrease in the overvoltage for the oxidation of ascorbic acid (230 mV), uric acid (160 mV) and hydrogen peroxide (300 mV) as well as a dramatic improvement in the reversibility of the redox behavior of dopamine and dopac, in comparison with the classical carbon (graphite) paste electrodes (CPE). The substantial decrease in the overvoltage of the hydrogen peroxide reduction (400 mV) associated with a successful incorporation of glucose oxidase (GOx) into the composite material, allow the development of a highly selective and sensitive glucose biosensor without using any metal, redox mediator or anti-interference membrane. No interference was observed at −0.100 V even for large excess of ascorbic acid, uric acid and acetaminophen. A linear response up to 30 mM (5.40 g l−1) glucose with a detection limit of 0.6 mM (0.11 g l−1) were obtained with the CNTPE modified with 10% w/w GOx. Such an excellent performance of CNTPE toward hydrogen peroxide, represents a very good alternative for developing other enzymatic biosensors.  相似文献   

6.
Chemiluminescence detection was developed as an alternative to amperometric detection for glucose analysis in a portable, microfluidics-based continuous glucose monitoring system. Amperometric detection allows easy determination of hydrogen peroxide, a product of the glucose oxidase-catalyzed reaction of glucose with oxygen, by oxidation at a microelectrode. However, (micro)electrodes in direct contact with physiological sample are subject to electrode fouling, which leads to signal drift, decreased reproducibility and shortened detector lifetimes. Moreover, there are a few species present in the body (e.g. ascorbic acid, uric acid) which can undergo oxidation at the same applied potential as hydrogen peroxide. These species can thus interfere with the glucose measurement, reducing detection specificity. The rationale for exploring chemiluminescence as opposed to amperometric detection is thus to attempt to improve the lifetime and reproducibility of glucose analysis for monitoring purposes, while reducing interference caused by other chemicals in the body. The study reported here represents a first step in this direction, namely the realization of a microfluidic device with integrated silicon photodiode for chemiluminescence detection of glucose. This microflow device uses a chaotic mixing approach to perform enzymatic conversion of glucose, followed by reaction of the hydrogen peroxide produced with luminol to produce light at 425 nm. The chemiluminescence reaction is catalyzed by horseradish peroxidase in the presence of iodophenol. The performance of the fabricated chip was characterized to establish optimal reaction conditions with respect to sample and reagent flow rates, pH, and concentrations. A linear calibration curve was obtained for current response as a function of glucose concentration in the clinically relevant range between 2 and 10 mM, with a sensitivity of 39 pA/mM (R = 0.9963, one device, n = 3) and a limit of detection of 230 μM (S/N = 3).  相似文献   

7.
This work reports the synthesis of single‐wall carbon nanotubes (SWCNT) covalently functionalized with polylysine (Plys) and the analytical performance of glassy carbon electrodes (GCE) modified with this material (GCE/SWCNT‐Plys). The resulting electrodes showed an important decrease in the overvoltages for the oxidation of ascorbic acid, uric acid and hydrogen peroxide as well as for the reduction of hydrogen peroxide. The favorable interaction of glucose oxidase (GOx) with SWCNT‐Plys allowed the sensitive and selective glucose biosensing at ?0.100 V without any permselective membrane. The proposed sensor was challenged with different real samples without pretreatment showing an excellent correlation with the reported values.  相似文献   

8.
A multilayered glucose biosensor via sequential deposition of Prussian blue (PB) nanoclusters and enzyme-immobilized poly(toluidine blue) films was constructed on a bare Au electrode using electrochemical methods. The whole configuration of the present biosensor can be considered as an integration of several independent hydrogen peroxide sensing elements. In each sensing element, the poly(toluidine blue) film functioned as both the supporting matrix for the glucose oxidase immobilization and the inhibitor for the diffusion of interferences, such as ascorbic acid and uric acid. Meanwhile, the deposited Prussian blue nanocluster layers acts as a catalyst for the electrochemical reduction of hydrogen peroxide formed from enzymatic reaction. Performance of the whole multilayer configuration can be tailored by artificially arranging the sensing elements assembled on the electrode. Under optimal conditions, the biosensors exhibit a linear relationship in the range of 1 x 10(-4) to 1 x 10(-2) mol/L with the detection limit down to 10(-5) mol/L. A rapid response for glucose could be achieved in less than 3 s. For 1 mM glucose, 0.5 mM acetaminophen, 0.2 mM uric acid, and 0.1 mM ascorbic acid have no obvious interferences (<5%) for glucose detection at an optimized detection potential. The present multilayered glucose biosensor with a high selectivity and sensitivity is promising for practical applications.  相似文献   

9.
An electrophoresis capillary that incorporates two enzymes for the simultaneous determination of glucose and L ‐glutamate is described. The enzymes deposited along the separation capillary walls react with their respective substrate as they are separated during the electrophoresis to produce hydrogen peroxide that is detected by amperometry as the hydrogen peroxide zone emerges from the end of the capillary. Even though both enzyme reactions produce a common product, hydrogen peroxide, the hydrogen peroxide produced by each enzyme reaction stays in narrow zones that migrate the length of the capillary at different rates. The rate of migration for the individual H2O2 zones is consistent with the expected mobility of neutral glucose and of anionic L ‐glutamate, respectively. This property allows each enzyme substrate to be characterized in a single experiment and in the presence of other electroactive substances.  相似文献   

10.
硼酸及硼酸酯类过氧化氢荧光探针的最新研究进展   总被引:2,自引:0,他引:2  
生物新陈代谢过程中产生的过氧化氢(H2O2)是生命活动所必需的,但是过量过氧化氢的存在可以引发多种疾病,因此对体内过氧化氢的检测具有重要意义.采用荧光探针法,借助激光共聚焦成像技术能够实现对活细胞和组织内的过氧化氢"实时、可见、定量"的检测,为深入阐明过氧化氢在生理和病理过程中所起的作用提供了一个重要手段.本文按荧光探针的结构分类,对近几年来以硼酸及硼酸酯基团作为荧光开关的具有高选择性和灵敏度的过氧化氢荧光探针进行了综述,主要探讨其设计思想、作用机制及应用,为过氧化氢探针的设计提供了新思路.  相似文献   

11.
An electrochemical in vivo flow-injection system with an on-line microdialysis sampling is proposed for the simultaneous monitoring of L-lactate and glucose in rat brain. In the first stage of the operation, the dialysate from the microdialysis probe is delivered to a sample loop of the six-way autoinjector by perfusing Ringer's solution for 80 s at 5 microl min(-1). In the second stage, the dialysate collected in the sample loop is automatically injected for 10 s into the flow-injection line. Injected dialysate is split into two streams and two portions pass through two channels with two different immobilized enzyme reactors (glucose oxidase and lactate oxidase immobilized reactors) to produce hydrogen peroxide from glucose and L-lactate in the dialysate. After a subsequent confluence of the streams, produced hydrogen peroxide can be detected amperometrically at a downstream poly(1,2-diaminobenzene) film-coated platinum electrode, without any interference from oxidizable species and proteins present in the dialysate. Because each channel has a different residence time, two peaks are obtained. The first peak corresponds to L-lactate and the second peak to glucose. The peak current is linearly related to the concentrations of L-lactate between 0.2 and 10 mM and glucose between 0.1 and 20 mM. The present method can be successfully applied to the simultaneous in vivo monitoring of L-lactate and glucose in rat brain. The analytical speed is 45 dialysates h(-1).  相似文献   

12.
Development of a highly sensitive fluorescence probe for hydrogen peroxide   总被引:2,自引:0,他引:2  
Hydrogen peroxide is believed to play a role in cellular signal transduction by reversible oxidation of proteins. Here, we report the design and synthesis of a novel fluorescence probe for hydrogen peroxide, utilizing a photoinduced electron transfer strategy based on benzil chemistry to control the fluorescence. The practical value of this highly sensitive and selective fluorescence probe, NBzF, was confirmed by its application to imaging of hydrogen peroxide generation in live RAW 264.7 macrophages. NBzF was also employed for live cell imaging of hydrogen peroxide generated as a signaling molecule in A431 human epidermoid carcinoma cells.  相似文献   

13.
We report determination of the apparent Michaelis constant of glucose oxidase (GOx) immobilized on a microelectrode with respect to oxygen. We used a GOx‐modified microelectrode as a probe for scanning electrochemical microscopy. We detected hydrogen peroxide generated by the enzyme reaction at the microelectrode under controlling the oxygen concentration using water electrolysis at an interdigitated array (IDA) electrode. The response depends on the oxygen concentration, which is regulated by the microelectrode position and the potential applied to the IDA electrode. We estimated the apparent Michaelis constant with respect to oxygen in this experimental condition to be about 0.28 mM.  相似文献   

14.
《Analytical letters》2012,45(5):913-926
Abstract

A new nanocomposite was developed by combination of prussian blue (PB) nanoparticles and multiwalled carbon nanotubes (MWNTs) in the matrix of biopolymer chitosan (CHIT). The PB and MWNTs had a synergistic electrocatalytic effect toward the reduction of hydrogen peroxide. The CHIT/MWNTs/PB nanocomposite‐modified glassy carbon (GC) electrode could amplify the reduction current of hydrogen peroxide by ~35 times compared with that of CHIT/MWNTs/GC electrode and reduce the response time from ~60 s for CHIT/PB/GC to 3 s. Besides, the CHIT/MWNTs/PB nanocomposite‐modified GC electrode could reduce hydrogen peroxide at a much lower applied potential and inhibit the responses of interferents such as ascorbic acid (AA) uric acid (UA) and acetaminophen (AC). With glucose oxidase (GOx) as an enzyme model, a new glucose biosensor was fabricated. The biosensor exhibited excellent sensitivity (the detection limit is down to 2.5 µM), fast response time (less than 5 s), wide linear range (from 4 µM to 2 mM), and good selection.  相似文献   

15.
Arnold MA  Zhou X  Petsch RS 《Talanta》1994,41(5):783-787
Feasibility is demonstrated for a novel gas-sensing, internal enzyme biosensing scheme for the selective measurement of hydrogen peroxide. Two horseradish peroxidase catalysed reactions are evaluated for the detection of hydrogen peroxide as it crosses a microporous Teflon membrane at 37 degrees C. The rate at which hydrogen peroxide crosses the membrane is determined by either a fluorescence or chemiluminescence measurement and this rate is related to the concentration of hydrogen peroxide in the sample solution. Detection limits of 0.7 mM and 10 muM are estimated for the fluorescence and chemiluminescence methods, respectively. Selectivity is demonstrated for hydrogen peroxide over ascorbic acid, uric acid and tyrosine.  相似文献   

16.
Jianzhong L  Zhujun Z  Ling L 《Talanta》1994,41(11):1999-2002
A simplified enzyme-based fiber optic sensor system has been developed for selective determination of hydrogen peroxide. Horseradish peroxidase (HRP) is immobilized on bovine albumin matrix with glutaraldehyde. A new fluorimetric substrate, thiamine is used to indicate the sensing process. Under optimized condition the measuring range of sensor is up to 1 x 10(-4)M hydrogen peroxide with a limit of detection of 5 x 10(-7)M in a 5 min response period. It can be easily incorporated in multienzyme sensors for biochemical substances which produce hydrogen peroxide under catalytic oxidation by their oxidase. This possibility has been tested for the determination of uric acid, D-amino acid, L-amino acid, glucose cholesterol, choline and acetylcholine, respectively, using a membrane with co-immobilized oxidase and horseradish peroxidase.  相似文献   

17.
An amperometric enzyme electrode for L-aspartate determination was developed. The probe consisted of a platinum electrode which senses hydrogen peroxide produced from the reactions catalyzed by two enzymes co-immobilized on a preactivated polymeric membrane, α-Ketoglutarate in the presence of L-aspartate was transaminated to L-glutamate by aspartate aminotransferase and the glutamate produced was oxidized by glutamate oxidase, with concomitant production of hydrogen peroxide. Additional protective membranes eliminated interferences from glutamate and most electroactive compounds. The response curve of the probe was linear over the concentration range 1.0 × 10?6 M to 2.0 × 10?4 M aspartate and was useful for at least two months. Aspartic acid in some pharmaceutical products was determined and the results correlated well with a liquid chromatographic reference method and the manufacturer's specification.  相似文献   

18.
The use of grape tissue as a source of catalase for the determination of hydrogen peroxide is reported. A slice of grape tissue attached to the membrane of a Clark-type oxgen sensor was used to monitor the oxidation of hydrogen peroxide by catalase. At the steady state, the sensor responds linearly to hydrogen peroxide in the concentration range 1 × 10?5–5 × 10?4 M. The response time (T90) was of the order of 1 min for this sensor. No interference was observed from ethanol, amino acids, glucose and lactic acid. The long-term stability of the grape tissue sensor was much better than previously reported immobilized enzyme and liver tissue-based hydrogen peroxide sensors.  相似文献   

19.
A kinetic flow-injection (FI) method is described for the determination of hydrogen peroxide. This method is based on an iron(III)-catalyzed oxidative coupling of 4-aminoantipyrine with N,N-dimethylaniline by hydrogen peroxide. By measuring the change in the absorbance of the dye formed at 560 nm, 1 x 10(-6) - 6 x 10(-4) M hydrogen peroxide could be determined with a sampling rate of 15 h(-1). The relative standard deviation (n = 30) was 0.8% for 5 x 10(-5) M hydrogen peroxide. There was little interference of the co-existing ions and compounds. After introducing some immobilized enzyme reactors to the FI system, the proposed method allowed the determination of glucose and uric acid ranging from 1 x 10(-6) to 6 x 10(-4) M with relative standard deviations of below 2%. The applicability of the method was demonstrated by determining these substances in serum samples.  相似文献   

20.
A novel recessed electrode is reported for amperometric detection of hydrogen peroxide and via glucose oxidase for the detection of glucose. The electrode utilised electrodeposited platinum over a gold wire surface, which proved to be an effective peroxide-detecting surface. Compared with a traditional exposed electrode surface, the recessed tip facilitated an extended linear range for glucose from 4 to over 14 mM. Bio-fouling, as assessed by exposure to bovine serum albumin, was also significantly reduced. Though response time at the recess was increased, it was within an acceptable range for physiological monitoring. Moreover, the recess enabled precise measurement of the hydrogen peroxide diffusion coefficient; this was based on a bipartite expression for the transient amperometric current at the recessed structure following a step change in ambient hydrogen peroxide concentration. An important aspect of the diffusion measurement was the curve fitting routine used to map on to the theoretical response curve.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号