首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
Recent developments in desorption/ionisation mass spectrometry techniques have made their application to biological analysis a realistic and successful proposition. Developments in primary ion source technology, mainly through the advent of polyatomic ion beams, have meant that the technique of secondary ion mass spectrometry (SIMS) can now access the depths of information required to allow biological imaging to be a viable option.Here the role of the primary ion C60+ is assessed with regard to molecular imaging of lipids and pharmaceuticals within tissue sections. High secondary ion yields and low surface damage accumulation are demonstrated on both model and real biological samples, indicating the high secondary ion efficiency afforded to the analyst by this primary ion when compared to other cluster ion beams used in imaging. The newly developed 40 keV C60+ ion source allows the beam to be focused such that high resolution imaging is demonstrated on a tissue sample, and the greater yields allow the molecular signal from the drug raclopride to be imaged within tissue section following in vivo dosing.The localisation shown for this drug alludes to issues regarding the chemical environment affecting the ionisation probability of the molecule; the importance of this effect is demonstrated with model systems and the possibility of using laser post-ionisation as a method for reducing this consequence of bio-sample complexity is demonstrated and discussed.  相似文献   

2.
二次离子质谱作为目前空间分辨率最高的质谱成像技术,以其免标记、高灵敏、多组分检测优势和亚微米级高空间分辨成像优势为诸多生命科学问题的研究提供了全新的分析手段,在基础细胞生物学、组织生理病理学、生物医药与临床医学等领域的研究中得到了广泛应用.本文综述了二次离子质谱在生物组织、细胞、仿生生物膜等体系中的质谱成像研究进展.  相似文献   

3.
In mass spectrometry imaging, spatial resolution is pushed to its limits with the use of ion microscope mass spectrometric imaging systems. An ion microscope magnifies and then projects the original spatial distribution of ions from a sample surface onto a position-sensitive detector, while retaining time-of-flight mass separation capabilities. Here, a new type of position-sensitive detector based on a chevron microchannel plate stack in combination with a 512 × 512 complementary metal-oxide-semiconductor based pixel detector is coupled to an ion microscope. Spatial resolving power better than 6 μm is demonstrated by secondary ion mass spectrometry and 8–10μm spatial resolving power is achieved with laser desorption ionization. A detailed evaluation of key performance criteria such as spatial resolution, acquisition speed, and data handling is presented.  相似文献   

4.
A new liquid metal ion gun (LMIG) filled with bismuth has been fitted to a time-of-flight-secondary ion mass spectrometer (TOF-SIMS). This source provides beams of Bi(n)q+ clusters with n = 1-7 and q = 1 and 2. The appropriate clusters have much better intensities and efficiencies than the Au3+ gold clusters recently used in TOF-SIMS imaging, and allow better lateral and mass resolution. The different beams delivered by this ion source have been tested for biological imaging of rat brain sections. The results show a great improvement of the imaging capabilities in terms of accessible mass range and useful lateral resolution. Secondary ion yields Y, disappearance cross sections sigma, efficiencies E = Y/sigma , and useful lateral resolutions deltaL have been compared using the different bismuth clusters, directly onto the surface of rat brain sections and for several positive and negative secondary ions with m/z ranging from 23 up to more than 750. The efficiency and the imaging capabilities of the different primary ions are compared by taking into account the primary ion current for reasonable acquisition times. The two best primary ions are Bi3+ and Bi5(2+). The Bi3+ ion beam has a current at least five times larger than Au3+ and therefore is an excellent beam for large-area imaging. Bi5(2+) ions exhibit large secondary ions yields and a reasonable intensity making them suitable for small-area images with an excellent sensitivity and a possible useful lateral resolution <400 nm.  相似文献   

5.
The need of cellular and sub‐cellular spatial resolution in laser desorption ionization (LDI)/matrix‐assisted LDI (MALDI) imaging mass spectrometry (IMS) necessitates micron and sub‐micron laser spot sizes at biologically relevant sensitivities, introducing significant challenges for MS technology. To this end, we have developed a transmission geometry vacuum ion source that allows the laser beam to irradiate the back side of the sample. This arrangement obviates the mechanical/ion optic complications in the source by completely separating the optical lens and ion optic structures. We have experimentally demonstrated the viability of transmission geometry MALDI MS for imaging biological tissues and cells with sub‐cellular spatial resolution. Furthermore, we demonstrate that in conjunction with new sample preparation protocols, the sensitivity of this instrument is sufficient to obtain molecular images at sub‐micron spatial resolution. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

6.
Summary A general surface analysis method has been developed based on non-selective photoionization of sputtered or desorbed neutral atoms and molecules above the surface, followed by time-of-flight mass spectrometry. The approach, currently utilizes two main types of ionizing radiation and a variety of desorption probes. For photoionization, coherent untuned sources are used; an intense focused pulsed UV laser beam is used for non-resonant multiphoton ionization to give elemental and limited chemical information, usually used for inorganic analysis; a coherent VUV source is used for single-photon ionization at 118 nm (10.5 eV) produced by frequency tripling of 355 nm light from a Nd:YAG laser. This paper focuses on single-photon ionization for inorganic systems. The desorption probes used are ion, electron, and laser beams as well as thermal desorption. For depth profiling, ion beams are specifically used. Any focused desorption probe beam can provide lateral spatial resolution.  相似文献   

7.
A prototype matrix-assisted laser desorption ionization time-of-flight (MALDI-TOF) mass spectrometer has been used for high-speed ion image acquisition. The instrument incorporates a Nd:YLF solid state laser capable of pulse repetition rates up to 5 kHz and continuous laser raster sampling for high-throughput data collection. Lipid ion images of a sagittal rat brain tissue section were collected in 10 min with an effective acquisition rate of roughly 30 pixels/s. These results represent more than a 10-fold increase in throughput compared with current commercially available instrumentation. Experiments aimed at improving conditions for continuous laser raster sampling for imaging are reported, highlighting proper laser repetition rates and stage velocities to avoid signal degradation from significant oversampling. As new high spatial resolution and large sample area applications present themselves, the development of high-speed microprobe MALDI imaging mass spectrometry is essential to meet the needs of those seeking new technologies for rapid molecular imaging.  相似文献   

8.
An atmospheric pressure laser desorption/ionization mass spectrometry imaging ion source has been developed that combines high spatial resolution and high mass resolution for the in situ analysis of biological tissue. The system is based on an infrared laser system working at 2.94 to 3.10 μm wavelength, employing a Nd:YAG laser-pumped optical parametrical oscillator. A Raman-shifted Nd:YAG laser system was also tested as an alternative irradiation source. A dedicated optical setup was used to focus the laser beam, coaxially with the ion optical axis and normal to the sample surface, to a spot size of 30 μm in diameter. No additional matrix was needed for laser desorption/ionization. A cooling stage was developed to reduce evaporation of physiological cell water. Ions were formed under atmospheric pressure and transferred by an extended heated capillary into the atmospheric pressure inlet of an orbital trapping mass spectrometer. Various phospholipid compounds were detected, identified, and imaged at a pixel resolution of up to 25 μm from mouse brain tissue sections. Mass accuracies of better than 2 ppm and a mass resolution of 30,000 at m/z?=?400 were achieved for these measurements.
Figure
Infrared laser desorption/ionization mass spectrometry imaging provides for direct analysis of biological tissue with a high spatial resolution of 25 μm  相似文献   

9.
The importance of imaging mass spectrometry (MS) for visualizing the spatial distribution of molecular species in biological tissues and cells is growing. We have developed a new system for imaging MS using MeV ion beams, termed MeV-secondary ion mass spectrometry (MeV-SIMS) here, and demonstrated more than 1000-fold increase in molecular ion yield from a peptide sample (1154 Da), compared to keV ion irradiation. This significant enhancement of the molecular ion yield is attributed to electronic excitation induced in the near-surface region by the impact of high energy ions. In addition, the secondary ion efficiency for biologically important compounds (>1 kDa) increased to more than 10(10) cm(-2), demonstrating that the current technique could, in principle, achieve micrometer lateral resolution. In addition to MeV-SIMS, peptide compounds were also analyzed with cluster-SIMS and the results indicated that in the former method the molecular ion yields increased substantially compared to the latter. To assess the capability of MeV-SIMS to acquire heavy-ion images, we have prepared a micropatterned peptide surface and successfully obtained mass spectrometric imaging of the deprotonated peptides (m/z 1153) without any matrix enhancement. The results obtained in this study indicate that the MeV-SIMS technique can be a powerful tool for high-resolution imaging in the mass range from 100 to over 1000 Da.  相似文献   

10.
Matrix assisted laser desorption/ionization (MALDI) imaging mass spectrometry (IMS) has been used to determine peptide distributions directly from rat, mouse and human pituitary tissue sections. Since these organs are small (102–103 μm) the spatial resolution of IMS is a key issue in molecular imaging of pituitary tissue sections. Here we show that high-resolution IMS allows localization of neuropeptide distributions within different cell clusters of a single organ of a pituitary tissue section. The sample preparation protocol does not result in analyte redistribution and is therefore applicable to IMS experiments at cellular length scales. The stigmatic imaging mass spectrometer used in this study produces selected-ion-count images with pixel sizes of 500 nm and a resolving power of 4 μm, yielding superior spatial detail compared to images obtained in microprobe imaging experiments. Furthermore, we show that with imaging mass spectrometry a distinction can be made between different mammalian tissue sections based on differences in the amino acid sequence of neuropeptides with the same function. This example demonstrates the power of IMS for label-free molecular imaging at relevant biological length scales.  相似文献   

11.
Localization of endogenous and exogenous compounds directly in tissue sections is a challenging task in skin research. Matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) is a powerful label-free technique that enables determination of the distribution of a large range of biomolecules directly in tissue sections. Nevertheless, its application in this field is limited in large part by the low adhesion of skin tissue sections to indium–tin oxide-coated (ITO) glass slides. For the first time corona discharge (CD) treatment was used to modify the glass slide surface for improved adhesion. Localization of endogenous cholesterol sulfate was performed directly in human skin tissue sections. A spatial resolution of approximately 30 μm was sufficient for assignment of mass signals to skin structure morphology. Furthermore, imaging of an exogenous model compound, Nile red, was performed directly in skin tissue sections after ex-vivo penetration into porcine skin, enabling determination of the pathway and depth of penetration. Finally, the ion density map of Nile red was compared with its high resolution fluorescence micrograph. This work provides new insights into the application of MALDI–MSI in skin research.  相似文献   

12.
The analysis of synthetic polymers represents today an important part of polymer science to determine their physical properties and to optimize the performance of polymeric materials for block copolymers as well as blend systems. The characterization can easily and rapidly be performed by mass spectrometry. In particular, the film formation of a synthetic polymer is of interest in material research and quality control, which can be determined by employing mass spectrometric imaging (MSI) using secondary ion mass spectrometry (SIMS) or matrix-assisted laser desorption/ionization (MALDI) mass spectrometry. MALDI-MSI has been rapidly improved for the analysis of tissue cross-sections due to its soft ionization and accessible m/z range, which both also play an important role in polymer science. On the other hand, SIMS-MSI enables a sub-micrometer molecular spatial resolution, which is limited in MALDI-MSI due to the spatial resolution capabilities of the laser desorption process. The aim of the present contribution is to summarize recent advances in both imaging techniques for the analysis of synthetic polymers and to highlight their capabilities to correlate several imaging modalities in future applications.  相似文献   

13.
The use of mass spectrometry (MS) to acquire molecular images of biological tissues and other substrates has developed into an indispensable analytical tool over the past 25 years. Imaging mass spectrometry technologies are widely used today to study the in situ spatial distributions for a variety of analytes. Early MS images were acquired using secondary ion mass spectrometry and matrix-assisted laser desorption/ionization. Researchers have also designed and developed other ionization techniques in recent years to probe surfaces and generate MS images, including desorption electrospray ionization (DESI), nanoDESI, laser ablation electrospray ionization, and infrared matrix-assisted laser desorption electrospray ionization. Investigators now have a plethora of ionization techniques to select from when performing imaging mass spectrometry experiments. This brief perspective will highlight the utility and relative figures of merit of these techniques within the context of their use in imaging mass spectrometry.  相似文献   

14.
Imaging mass spectrometry provides both chemical information and the spatial distribution of each analyte detected. Here it is demonstrated how imaging mass spectrometry of tissue at subcellular resolution can be achieved by combining the high spatial resolution of secondary ion mass spectrometry (SIMS) with the sample preparation protocols of matrix-assisted laser desorption/ionization (MALDI). Despite mechanistic differences and sampling 10(5) times less material, matrix-enhanced (ME)-SIMS of tissue samples yields similar results to MALDI (up to m/z 2500), in agreement with previous studies on standard compounds. In this regard ME-SIMS represents an attractive alternative to polyatomic primary ions for increasing the molecular ion yield. ME-SIMS of whole organs and thin sections of the cerebral ganglia of Lymnaea stagnalis demonstrate the advantages of ME-SIMS for chemical imaging mass spectrometry. Subcellular distributions of cellular analytes are clearly obtained, and the matrix provides an in situ height map of the tissue, allowing the user to identify rapidly regions prone to topographical artifacts and to deconvolute topographical losses in mass resolution and signal-to-noise ratio.  相似文献   

15.
The capabilities of time of flight secondary ion mass spectrometry (TOF-SIMS) have been recently greatly improved with the arrival in this field of polyatomic ion sources. This technique is now able to map at the micron scale intact organic molecules in a range of a thousand Daltons or more, at the surface of tissue samples. Nevertheless, this remains a surface analysis technique, and three-dimensional information on the molecular composition of the sample could not be obtained due to the damage undergone by the organic molecules during their irradiation. The situation changed slightly with the low damage and low penetration depth of the C60 fullerene ion beams. Recent promising studies have shown the possibility of organic molecular depth profiling using this kind of beams onto model samples. This possibility has been tried out directly onto a rat brain tissue section, which is the most commonly used biological tissue model in TOF-SIMS imaging method developments. The tissue surface has been sputtered with a 10 keV energy fullerene ion beam, and surface analyses were done with a 25 keV Bi3+ ion beam at regular time intervals. The total depth which was analysed was more than two microns, with total primary ion doses of more than 1016 ions cm−2. Although not in contradiction with results previously published but with much lower doses, it is found that the molecular damage remains too large, thus making molecular imaging very difficult. In addition, most of the lipids, which are usually the main observable molecules in TOF-SIMS, are concentrated close to the sample surface in the first hundreds of nanometers.  相似文献   

16.
A new methodology applicable for both high‐resolution laser desorption/ionization mass spectrometry and mass spectrometry imaging of amino acids is presented. The matrix‐assisted laser desorption ionization‐type target containing monoisotopic cationic 109Ag nanoparticles (109AgNPs) was used for rapid mass spectrometry measurements of 11 amino acids of different chemical properties. Amino acids were directly tested in 100,000‐fold concentration change conditions ranging from 100 μg/mL to 1 ng/mL which equates to 50 ng to 500 fg of amino acid per measurement spot. Limit of detection values obtained suggest that presented method/target system is among the fastest and most sensitive ones in laser mass spectrometry. Mass spectrometry imaging of spots of human blood plasma spiked with amino acids showed their surface distribution allowing optimization of quantitative measurements.  相似文献   

17.
The structural information and spatial distribution of molecules in biological tissues are closely related to the potential molecular mechanisms of disease origin, transfer, and classification. Ambient ionization mass spectrometry imaging is an effective tool that provides molecular images while describing in situ information of biomolecules in complex samples, in which ionization occurs at atmospheric pressure with the samples being analyzed in the native state. Ambient ionization mass spectrometry imaging can directly analyze tissue samples at a fairly high resolution to obtain molecules in situ information on the tissue surface to identify pathological features associated with a disease, resulting in the wide applications in pharmacy, food science, botanical research, and especially clinical research. Herein, novel ambient ionization techniques, such as techniques based on spray and solid‐liquid extraction, techniques based on plasma desorption, techniques based on laser desorption ablation, and techniques based on acoustic desorption were introduced, and the data processing of ambient ionization mass spectrometry imaging was briefly reviewed. Besides, we also highlight recent applications of this imaging technology in clinical researches and discuss the challenges in this imaging technology and the perspectives on the future of the clinical research.  相似文献   

18.
In this work, the isolation step in the linear ion trap was performed using different “q values” conditions at a low collision-induced dissociation (CID) energy leading to the parent ion resolution improvements, reasonably due to better ion energy distribution. According to the results, we obtained a greater resolution and mass accuracy operating in both traditional electrospray and low voltage ionization near the q value = 0.778 and with a CID energy of 10%. This effect was evaluated with low-molecular-mass compounds (skatole and arginine). The proposed optimization yielded a superior instrument performance without adding technological complexity to mass spectrometry analyses.  相似文献   

19.
The hydrogen (H)/sodium (Na) interface is of great interest in glass corrosion research. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is one of the few techniques that can provide nanoscale H and Na imaging simultaneously. However, the optimized condition for ToF-SIMS imaging of H in glass is still unclear. In H depth profiling using ToF-SIMS, H background control is a key, in which an analysis ion beam and a sputtering ion beam work together in an interlaced mode to minimize it. Therefore, it is of great interest to determine if an auxiliary sputtering ion beam is also necessary to control H background in ToF-SIMS imaging of H. In this study, H imaging with and without auxiliary sputtering beams (Cs+, O2+, and Arn+) was compared on a corroded international simple glass (ISG). It was surprising that the H/Na interface could be directly imaged using positive ion imaging without any auxiliary sputtering ion beam under a vacuum of 2 to 3 × 10−8 mbar. The H+ background was about 5% atomic percent on the pristine ISG glass, which was significantly lower than the H concentration in the alteration layer (~15%). Moreover, positive ion imaging could show distributions of other interesting species simultaneously, providing more comprehensive information of the glass corrosion. If an auxiliary O2+ sputtering ion beam was used, the H+ background could be reduced but still higher than that in the depth profiling. Besides, this condition could cause significant loss of signal intensities due to strong surface charging.  相似文献   

20.
Imaging G-SIMS: a novel bismuth-manganese source emitter   总被引:1,自引:0,他引:1  
G-SIMS (gentle-SIMS) is a powerful method that considerably simplifies complex static secondary ion mass spectrometry (SSIMS) analysis of organics at surfaces. G-SIMS uses two primary ion beams that generate high and low fragmentation conditions at the surface. This allows an extrapolation to equivalent experimental conditions with very low fragmentation. Consequently, the spectra are less complex, contain more structural information and are simpler to interpret. In general, G-SIMS spectra more closely resemble electron ionisation mass spectra than SSIMS spectra. A barrier for the wider uptake of G-SIMS is the requirement for two ion beams producing suitably different fragmentation conditions and the need for their spatial registration (spatial alignment) at the surface, which is especially important for heterogeneous samples. The most popular source is the liquid metal ion source (LMIS), which is now sold with almost every new time-of-flight (TOF)-SIMS instrument. Here, we have developed a novel bismuth-manganese emitter (the 'G-tip') for the popular LMISs. This simplifies the alignment and gives excellent G-SIMS imaging and spectroscopy without significantly compromising the bismuth cluster ion beam performance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号