首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Shamsi SA 《Electrophoresis》2002,23(22-23):4036-4051
A review is presented to highlight several approaches for coupling capillary electrophoresis (CE) and electrospray ionization-mass spectrometry (ESI-MS) for analysis of chiral compounds. A short discussion of commercially available CE-MS instruments and interface design is followed by a detail review on various modes of chiral CE-MS. In general, for each CE-MS mode, the capabilities, applications and limitations for chiral analysis have been pointed out. The first mode, chiral capillary zone electrophoresis-mass spectrometry (CZE-MS) in which neutral derivatized cyclodextrins (CDs) are used is possible using either column coupling with voltage switching or a partial-filling technique (PFT). However, some applications of direct coupling of CZE-MS mode are also reported. The second mode is a chiral electrokinetic chromatography-mass spectrometry (EKC-MS) in which a charged chiral selector such as a sulfated beta-CD or a vancomycin could be conveniently employed. This is because these chiral selectors have a significantly higher countercurrent electrophoretic mobility which prevents the entrance of these selectors into the mass spectrometer. The combination of counter-migration and PFT demonstrates that this synergism could be successfully applied to chiral analysis of a broader range of compounds. It is well-known that the on-line coupling of micellar electrokinetic chromatography to mass spectrometry (MEKC-MS) is problematic because the high surface activity and nonvolatile nature of conventional surfactant molecules lower the electrospray ionization efficiency. However, a recent report demonstrates that this hyphenation is now possible with the use of molecular micelles. Various MEKC-ESI-MS parameters that can be used to optimize both chiral resolution and ESI response are discussed. Finally, two recent examples that demonstrate the feasibility of using either open-tubular or packed chiral CEC with MS are reviewed. This survey will attempt to cover the state-of-the-art on various modes of CE-MS from 1998 up to 2002.  相似文献   

2.
3.
A new approach for simultaneous chiral and achiral separations by capillary zone electrophoresis is described. Two adjacent selector plugs, consisting of Tween 20 as an achiral and methyl-beta-cyclodextrin (CD) as a chiral selector, are employed and four related local anesthetics are used as model compounds. The principles of the partial filling technique, whereby the capillary is filled with the chiral selector solution followed by the micellar solution at different plug lengths and concentrations, prior to application of the solutes, was employed. During the run both capillary ends were dipped in a simple buffer, i.e., one without additives. The two separation media worked independently without any interaction. Separation of the solutes and their enantiomers was regulated by adjusting both the concentration and plug length (PL) of the micellar solution in the capillary, employing methyl beta-CD as chiral selector either at 38 or 76 mM. The solutes were separated on the basis of their affinity towards the micellar phase before they reached the methyl-beta-CD plug for enantioseparation. In the absence of the micellar plug, the enantiomers of prilocaine overlapped those of bupivacaine. The solutes and their enantiomers were completely separated by employing two adjacent plugs consisting of 100 mM Tween 20 solution (PL approximately 10 cm) and methyl-beta-CD solution at either 38 or 76 mM (PL approximately 30 cm).  相似文献   

4.
Zhang H  Qi L  Mao L  Chen Y 《Journal of separation science》2012,35(10-11):1236-1248
Over the last couple of decades, researchers have developed diverse chiral separation methods emerged from a few chiral separation principles. This review article is primarily focused on the application of chiral ligand-exchange (CLE) principle in capillary electromigration techniques, such as capillary electrophoresis (CE) and capillary electrochromatography (CEC). First, the most commonly used CLE-CZE separation mode by using different kinds of central ions, such as Cu(II), Zn(II), borate ion, and other metal ions, has been introduced. Meanwhile, several kinds of surfactants have been applied as the micelle-forming agents in the CLE micellar electrokinetic chromatography mode. The highlight of recent research of CLE-CEC is the exploitation of novel columns for chiral separation. Then, two kinds of capillary columns, packed capillary and monolithic capillary column, have been briefly described. Finally, the effective application of these chiral separation methods has been presented, including the application in life science and food analysis area.  相似文献   

5.
The review summarizes the most recent developments in the field of enantioseparation of chiral drugs using capillary electromigration techniques. The basic principles of enantioseparations in CE are discussed. Recent developments in sample introduction, separation and detection in capillary electrophoresis and capillary electrochromatography are summarized. The applications are arbitrarily divided into the following three groups: (a) racemates and artificial mixtures of enantiomers, (b) drug forms and (c) chiral drugs and their metabolites in biological fluids. Among the various techniques involved the relatively new developments such as CEC in aqueous and nonaqueous buffers, on-line CE-MS coupling, etc. are emphasized.  相似文献   

6.
This review covers recent progress in polyelectrolyte multilayer (PEM) coatings applied to analytical separations using open-tubular capillary electrochromatography (OT-CEC). The simple preparation procedure involved in the PEM approach has provided some attractive features over other modes of capillary electrophoresis-based separations including packed column capillary electrochromatography (PC-CEC) and micellar electrokinetic chromatography (MEKC). PEM coatings have been used to alleviate the adsorption of basic analytes, to improve separations, and to improve the stability of the electroosmotic flow. Fundamental aspects of PEM coatings on surfaces and analytical separation platforms are briefly outlined in this review. In addition, applications of PEM coatings to fused-silica capillaries or microchip separation devices for the separation of small achiral or chiral analytes, as well as large biomolecules, are discussed.  相似文献   

7.
Stutz H 《Electrophoresis》2005,26(7-8):1254-1290
High throughput, outstanding certainty in peptide/protein identification, exceptional resolution, and quantitative information are essential pillars in proteome research. Capillary electrophoresis (CE) coupled to mass spectrometry (MS) has proven to meet these requirements. Soft ionization techniques, such as matrix-assisted laser desorption/ionization (MALDI) and electrospray ionization (ESI), have paved the way for the story of success of CE-MS in the analysis of biomolecules and both approaches are subject of discussion in this article. Meanwhile, CE-MS is far away from representing a homogeneous field. Therefore the review will cover a vast area including the coupling of different modes of CE (capillary zone electrophoresis, capillary isoelectric foscusing, capillary electrochromatography, micellar electrokinetic chromatography, nonaqueous capillary electrophoresis) to MS as well as on-line preconcentration techniques (transient capillary isotachophoresis, solid-phase extraction, membrane preconcentration) applied to compensate for restricted detection sensitivity. Special attention is given to improvements in interfacing, namely addressing nanospray and coaxial sheath liquid design. Peptide mapping, collision-induced dissociation with subsequent tandem MS, and amendments in mass accuracy of instruments improve information validity gained from MS data. With 2-D on-line coupling of liquid chromatography (LC) and CE a further topic will be discussed. A special section is dedicated to recent attempts in establishing CE-ESI-MS in proteomics, in the clinical and diagnostic field, and in the food sector.  相似文献   

8.
Application of capillary electrophoresis (CE) in combination with mass spectrometry (MS) and tandem MS to glycoscreening in biomedical projects is highlighted. In the first part recent CE-MS experiments by sheath liquid CE and multiple stage MS are reported. Neutral and negatively charged N-glycan mixtures from ribonuclease B and fetuin, high-mannose type N-glycoforms, oligosaccharides from lipopolysaccharides (LPS) of Haemophilus influenzae, polysaccharides of Pseudomonas aeruginosa and Staphylococcus aureus were analyzed. A particular emphasis is devoted to the applicability of novel off- and on-line CE-MS and tandem MS methods for screening of proteoglycan-derived oligosaccharides, glycosaminoglycans (GAGs), such as hyaluronates from Streptococcus agalactiae, chondroitin/dermatan sulfates (CS/DS) from bovine aorta and human skin fibroblast decorin, and heparin/heparan sulfate (HS) from porcine and bovine mucosa. The performance of CE-MS/MS for identification of glycoforms in glycopeptides and glycoproteins is illustrated by experiments performed on complex mixtures from urine of patients suffering from a hereditary N-acetylhexosaminidase deficiency (Schindler's disease) and urine of patients suffering from cancer cachexia. For determination of glycosylation patterns in glycoproteins like enzymes and antibodies by CE/MS, both CE-matrix assisted laser desorption/ionization (MALDI) and CE-electrospray ionization (ESI)-MS were functional. Finally, the potential of CE-ESI-MS strategy in glycolipid analysis is demonstrated for gangliosides from bovine brain for which particular CE buffer conditions are required.  相似文献   

9.
A novel procedure was developed for the fabrication of a fritless packed column for the coupling of capillary electrochromatography (CEC) to mass spectrometry (MS). The process involved the formation of internal tapers on two separate columns. Once the internal tapers are formed and the columns are packed, the untapered ends of each column were joined together by a commercially available connector. Several advantages of the fritless columns are described. First, the design used here eventually eliminates the need for any frits thus reducing the possibility of bubble formation seen with fritted packed columns. In addition, this is the first report in which the internal tapers are formed at both the inlet and outlet column ends making the fritless CEC-MS column more robust compared to only one report with externally tapered counterparts. Second, a comparison of internally tapered single frit packed CEC-MS (previously developed in our laboratory) column versus fritless CEC-MS column reported here shows that the latter provides better efficiency, suggesting no dead volume with equally good sensitivity and chiral resolution of (±)-aminoglutethimide. The fritless column procedure is universal and was used to prepare a series of columns with a variety of commercially available packing material (mixed mode strong cation exchange, SCX; mixed mode strong anion exchange, SAX; C-18) for the separation and MS detection of short chain non-chromophoric polar amines, long chain nonchromophic anionic surfactant as well as oligomers of non-chromophoric non-ionic surfactants, respectively. The fritless columns showed good intra-day repeatability and inter-day reproducibility of retention times, chiral and achiral resolutions and peak areas. Very satisfactory column-to-column and operator-to-operator reproducibility was demonstrated.  相似文献   

10.
Wistuba D  Schurig V 《Electrophoresis》2000,21(18):4136-4158
Enantiomer separation by electrochromatography (CEC) can be performed in three modes: (i) open-tubular capillary electrochromatography (o-CEC), in which the chiral selector is physically adsorbed coated, and thermally immobilized or covalently attached to the internal capillary wall; (ii) packed capillary electrochromatography (p-CEC), in which the capillary is either filled with chiral modified silica particles or with an achiral packing material, and a chiral selector is added to the mobile phase; and (iii) monolithic (rod)-capillary electrochromatography (rod-CEC) in which the chiral stationary phase (CSP) consists of a single piece of porous solid. We present an overview on methods and new trends in the field of electrochromatographic enantiomer separation such as CEC with either nonaqueous mobile phases or stationary phases with incorporated permanent charges, or with packing beds consisting of nonporous silica particles or particles with very small internal diameters.  相似文献   

11.
Moini M  Huang H 《Electrophoresis》2004,25(13):1981-1987
We introduce capillary electrophoresis-mass spectrometry (CE-MS) as an efficient means for the on-line separation and identification of protein mixtures. It was found that while CE/electrospray ionization (ESI)-MS analysis of whole-cell lysate was too complicated for the one-dimensional CE-MS analysis, the technique was useful for the analysis of protein mixtures of moderate complexity (approximately 50 intact proteins). CE/ESI-MS was applied to the subcellular proteomics of ribosomal Escherichia coli. 55 out of the 56 ribosomal proteins were detected with ease by using only approximately 3.4 ng of ribosomal proteins. In addition, it was found that the mass accuracy of the conventional MS (such as quadrupole ion traps) was good enough to identify many post-translational modifications of the intact proteins by simply comparing their measured average molecular weight with the average molecular weight predicted from gene banks.  相似文献   

12.
Capillary electrophoresis (CE) mass spectrometry (MS), with its ability to separate compounds present in extremely small volume samples rapidly, with high separation efficiency, and with compound identification capability based on molecular weight, is an extremely valuable analytical technique for the analysis of complex biological mixtures. The highest sensitivities and separation efficiencies are usually achieved by using narrow capillaries (5-50 micro m i.d.) and by using sheathless CE-to-MS interfaces. The difficulties in CE-to-MS interfacing and the limited loadability of these narrow columns, however, have prevented CE-MS from becoming a widely used analytical technique. To remedy these limitations, several CE-MS interfacing techniques have recently been introduced. While electrospray ionization is the most commonly used ionization technique for interfacing CE-to-MS, matrix assisted laser desorption ionization has also been used, using both on-line and off-line techniques. Moreover, the high concentration detection limit of CE has been addressed by development of several sample concentration and sample focusing methods. In addition, a wide variety of techniques such as capillary zone electrophoresis, capillary isoelectric focusing, and on-column transient isotachophoresis have now been interfaced to MS. These advances have resulted in a rapid increase in the use of CE-MS in the analysis of complex biological mixtures. CE-MS has now been successfully applied to the analysis of a wide variety of compounds including amino acids, protein digests, protein mixtures, single cells, oligonucleotides, and various small molecules relevant to the pharmaceutical industry.  相似文献   

13.
The sol-gel method is a widely used technique for the synthesis of various functional coating films. Alkoxysilanes such as (3-methacryloxypropyl)trimethoxysilane (MEMO) are largely used as precursors for inorganic-organic hybrid sol-gel materials. Indeed, these compounds can form complex network, through hydrolysis and condensation reactions. The latter have to be perfectly controlled to obtain the required properties. In such a context, we have studied the potentialities of capillary electrophoresis-ion-trap mass spectrometry (CE-MS) coupling to resolve both separation and characterization of the synthesized compounds as a function of the hydrolysis time. The study of acid hydrolysis of MEMO was carried out as an example. After optimization of the running electrolyte in capillary zone electrophoresis (CZE) with UV detection, we characterized the synthesized compounds in CE-MS by using positive detection mode. The obtained resolution in CZE-UV was not entirely satisfactory because of the very closed charge/mass ratio of formed solute but also because of the interaction between the solutes and the capillary walls. Nevertheless, several oligomers were characterized in CE-MS. The absence of detection with regard to oligomers that possess higher molecular masses than octamer is discussed in this work.  相似文献   

14.
以亲水作用色谱为核心的液相色谱联用技术及其应用研究   总被引:7,自引:0,他引:7  
王媛  顾惠新  路鑫  许国旺 《色谱》2008,26(6):649-657
亲水作用色谱(HILIC)是近年来色谱领域研究的热点之一。本文围绕复杂体系样品中亲水性组分的分离分析,综述了国际上近年 来发展的以HILIC为核心的多种液相色谱联用技术及其应用。简要介绍了HILIC的起源、定义、分离特点及其常用固定相;比较了HILIC和反相色谱(RPLC)的选择特性;针对不同层次的分离对象和分离要求,讨论了多种基于HILIC的液相色谱以及液相色谱-质谱联用技术的分离特点和适用范围。  相似文献   

15.
This review covers recent advances of capillary electrophoresis (CE) in pharmaceutical analysis. The principle, instrumentation, and conventional modes of CE are briefly discussed. Advances in the different CE techniques (non-aqueous CE, microemulsion electrokinetic chromatography, capillary isotachophoresis, capillary electrochromatography, and immunoaffinity CE), detection techniques (mass spectrometry, light-emitting diode, fluorescence, chemiluminescence, and contactless conductivity), on-line sample pretreatment (flow injection) and chiral separation are described. Applications of CE to assay of active pharmaceutical ingredients (APIs), drug impurity testing, chiral drug separation, and determination of APIs in biological fluids published from 2008 to 2009 are tabulated.  相似文献   

16.
The combination of micellar electrokinetic chromatography (MEKC) with mass spectrometry (MS) is very attractive for the direct identification of analyte molecules, for the possibility of selectivity enhancement, and for the structure confirmation and analysis in a MS-MS mode. The direct coupling of MEKC with MS can be hazardous due to the effect of nonvolatile MEKC surfactants on MS performance, including the loss of analyte sensitivity and ion source contamination. The possibility of off-line coupling between MEKC and matrix-assisted laser desorption/ionization (MALDI)-MS remains to be investigated. Various approaches for on-line coupling MEKC with electrospray ionization (ESI)-MS, including the use of high-molecular-mass surfactant, an electrospray-chemical ionization (ES-CI) interface, a voltage switching and buffer renewal system, partial-filling micellar plug and anodically migrating micelles, are reviewed and evaluated. The use of an ES-CI interface is most promising for routine operation of on-line MEKC-MS under the influence of nonvolatile salts and surfactants. The use of a high-molecular-mass surfactants allows the formation of a micellar phase at very low surfactant concentrations and avoids the generation of a high level of background ions in the low m/z region. Alternatively, the application of a partial-filling micellar plug and anodically migrating micelles eliminate the introduction of MEKC micelles into the ESI-MS system. It is possible to directly transfer the conventional MEKC separations to partial-filling MEKC-ESI-MS and MEKC-ESI-MS using anodically migrating micelles without any instrument modifications.  相似文献   

17.
This review represents a summary of recent progress in open-tubular capillary electrochromatography (OT-CEC) for chiral and achiral separations. The OT-CEC approach is an alternative to packed-CEC that could eliminate the problems associated with retaining frits and silica particles. In OT-CEC, the stationary phase is immobilized on the inner walls of the capillary. Preparation of the stationary phase is critical for OT-CEC. The preparation methods for capillary columns include (i) adsorption, (ii) covalent bonding and/or cross-linking, (iii) porous layers, (iv) chemical bonding after etching, (v) sol-gel, and (vi) molecular imprinting. Major developments, potential applications, technical difficulties and advantages associated with these wall coatings in OT-CEC are presented. In addition, the coupling of OT-CEC with mass spectrometry (MS) is briefly reviewed. Several applications of this hyphenated technique for analytical separations are also summarized.  相似文献   

18.
Seven commercially-available chiral capillary gas chromatography columns containing modified cyclodextrins were evaluated for their ability to separate enantiomers of the 19 stable chiral polychlorinated biphenyl (PCB) atropisomers, and for their ability to separate these enantiomers from achiral congeners, necessary for trace environmental analysis of chiral PCBs. The enantiomers of each of the 19 chiral PCBs were at least partially separated on one or more of these columns. Enantiomeric ratios of eleven atropisomers could also be quantified on six columns as they did not coelute with any other congener containing the same number of chlorine atoms, so could be quantified using gas chromatography-mass spectrometry. Analysis of a lake sediment heavily contaminated with PCBs showed enantioselective occurrence of PCB 91, proof positive of enantioselective in situ reductive dechlorination at the sampling site.  相似文献   

19.
Nonlinear effects caused by molecular association of enantiomers in non-racemic mixtures can cause unexpected effects in chiroptics, NMR spectroscopy, homogeneous catalysis, and chromatography. Herein we present a theoretical model to simulate and verify unusual elution orders of enantiomers on an achiral stationary phase doped with a small amount of a chiral selector or achiral columns coupled with columns doped with a chiral selector. Scenarios with strong, medium, and weak associations of enantiomers, different separation efficiencies typical for flash chromatography and liquid chromatography, and the influence of the enantioselectivity of the chiral selector on the complex equilibria have been investigated. The findings presented here are of importance for the validation of the determination of enantiomeric ratios in not fully separated elution zones as well as for the preparative separation of non-racemic enantiomeric mixtures on chiral stationary phases bonded to achiral matrices.  相似文献   

20.
许旭  陈钢  刘浩 《色谱》2020,38(10):1154-1169
药物分析是毛细管电泳(CE)的重要应用领域,所有CE分离模式与检测方法都在各种药物及其不同形式样品的分离分析中显示出特色和应用能力。该文从药品分析领域中的小分子药物(包括手性药物)及其有关物质、中药与天然产物、体内药物分析、生物制品药物分析等几个方面,综述了近几年CE在这些传统药物分析领域应用的研究进展。限于篇幅,未包括现代药物分析研究比较活跃的理化常数测定、亲和毛细管电泳与结合常数研究(药物与受体间的相互作用等)、临床生物标志物分析、代谢组学和微流控芯片CE分析等方面的内容。根据目前传统药物分析领域的发展,该文关注到近期CE在顺应药物分析的法规需求、电容耦合非接触电导检测(CE-C4 D)、改进检测灵敏度与精密度、CE-十二烷基硫酸钠(SDS)毛细管电泳、全柱成像毛细管等电聚焦(icIEF)、抗体分析等方面的新进展。该文结合文献,讨论了目前传统药物分析领域的需求,以及CE在其中的地位、挑战和机遇。对目前CE主要作为互补分析方法在化学药和中药分析中的应用研究提出了一些针对性的建议,期待CE在生物制品分析中的特色和能力得到进一步的发挥,同时提出CE-MS和对CE分析重复性改进等新进展可能对未来CE应用领域的大幅度扩展。该综述主要涉及近3年(2017年1月到2020年2月)及部分2016年的相关文献。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号