 共查询到20条相似文献,搜索用时 31 毫秒
1.
Matrix-assisted laser desorption/ionization (MALDI) was performed using two pulsed lasers with wavelengths in the IR and UV regions. A 10.6 micro m pulsed CO(2) laser was used to irradiate a MALDI target, followed after an adjustable delay by a 337 nm pulsed nitrogen laser. The sample consisted of a 2,5-dihydroxybenzoic acid matrix and bovine insulin guest molecule. The pulse energy for both of the lasers was adjusted so that the ion of interest, either the matrix or guest ion, was not produced by either of the lasers alone. The delay time for maximum ion yield occurs at 1 micro s for matrix and guest ions and the signal decayed to zero in approximately 400 micro s. A mechanism is presented for enhanced UV MALDI ion yield following the IR laser pulse based on transient heating.  相似文献   

2.
Fragmentation processes that occur very early during matrix-assisted laser desorption ionization (MALDI) of peptides are examined by utilization of delayed pulsed ion extraction with a linear time-of-flight mass spectrometer. The oxidized B chain of bovine insulin (MW=3495. 95 u), which produces a wide range of fragment ions, is utilized as a probe to examine the effects of several experimental parameters on this process. Experimental evidence suggests that this MALDI process is not prompt fragmentation and involves metastable ion decay that is quite different from that which is observed with postsource decay experiments. This conclusion is based upon the significant differences observed in the fragmentation products produced by the two techniques. This metastable ion decay process also appears to be over within the minimum pulse delay period (320 ns) that is possible with the current pulsed ion extraction hardware. These two observations suggest that either different activation processes are involved in the two techniques or that the much different time frame of the methods influences the observed ion decay pathways. This fast MALDI metastable ion fragmentation also is shown to be influenced by both the MALDI matrix and the laser fluence.  相似文献   

3.
For matrix‐assisted laser desorption/ionization (MALDI) mass spectra, undesirable ion contamination can occur due to the direct laser excitation of substrate materials (i.e., laser desorption/ionization (LDI)) if the samples do not completely cover the substrate surfaces. In this study, comparison is made of LDI processes on substrates of indium and silver, which easily emit their own ions upon laser irradiation, and conventional materials, stainless steel and gold. A simultaneous decrease of ion intensities with the number of laser pulses is observed as a common feature. By the application of an indium substrate to the MALDI mass spectrometry of alkali salts and alkylammonium salts mixed with matrices, 2,5‐dihydroxybenzoic acid (DHB) or N‐(4‐methoxybenzylidene)‐4‐butylaniline (MBBA), the mixing of LDI processes can be detected by the presence of indium ions in the mass spectra. This method has also been found to be useful for investigating the intrinsic properties of the MALDI matrices: DHB samples show an increase in the abundance of fragment ions of matrix molecules and cesium ions with the number of laser pulses irradiating the same sample spot; MBBA samples reveal a decrease in the level of background noise with an increase in the thickness of the sample layer. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

4.
Delayed extraction experiments were undertaken to precise the dynamical effects involved in the ion formation in ultraviolet matrix-assisted laser desorption/ionization (UV-MALDI). Careful examination of the ion time-of-flight variation with the extraction delay time were performed with a repulsive potential before ion extraction. Depending on the mass of the ion (matrix 2,5-dihydroxybenzoic acid and peptides) and on the repulsing potential, some deviations from the linear relationship between the ion time-of-flight and the delay time were observed. Simulations of the ion time-of-flight clearly show that ions are not directly produced on the target surface but originate from the gas-phase decomposition of higher mass precursors. The size of the precursor, composed of the analyte surrounded by matrix molecules, increases with that of the analyte. Complete desolvation of the cluster-precursor could be likely induced by the high electric field transient during the pulse extraction. The existence of clusters as precursor of the ion production in MALDI highlights a new global frame to explain the analyte protonation in UV-MALDI.  相似文献   

5.
Insufficient vacuum stability of matrix chemicals is a major limitation in matrix-assisted laser desorption/ionization (MALDI) mass spectrometry imaging (MSI) of large tissue sample cohorts. Here, we designed and synthesized the photo-cleavable caged molecule 4,5-dimethoxy-2-nitrobenzyl-2,5-dihydroxyacetophenone (DMNB-2,5-DHAP) and employed it for lipid MALDI-MSI of mouse brain tissue sections. DMNB-2,5-DHAP is vacuum-stable in a high vacuum MALDI ion source for at least 72 h. Investigation of the uncaging process suggested that the built-in laser (355 nm) in the MALDI ion source promoted the in situ generation of 2,5-DHAP. A caging group is used for the first time in designing a MALDI matrix that is vacuum-stable, uncaged upon laser irradiation during the measurement process, and that boosts lipid ion intensity with MALDI-2 laser-induced postionization.  相似文献   

6.
Four C3-symmetrical tris(dipeptide) disks and their precursors were characterized using matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI TOF MS). The C3-symmetrical disks were based on a benzene-1,3,5-triscarboxamide core extended by oligopeptides with trialkoxyanilide tails. The results indicate that MALDI TOF MS is a powerful and straightforward analytical technique for characterizing C3-symmetrical disks and their precursors. Clear (pseudo)-molecular ion peaks could readily be identified. It is remarkable that strong radical ion signals were observed for all the compounds, including the anilines that were expected to be protonated prior to laser irradiation using acidic MALDI matrixes. Possible mechanisms for radical ion formation were investigated with the employment of radical scavengers, with various matrixes and with direct laser desorption/ionization (LDI). Most likely the radicals are formed by losing one electron from the aniline nitrogen and stabilized by conjugation through the phenyl ring. It appears that direct photo/thermal ionization of analytes is an important route for the radical ion formation of the compounds with trialkoxy aniline/anilide groups.  相似文献   

7.
The molecular weight distribution of the asphaltene fractions of two types of crude oils from two different Italian fields (samples 1 and 2) was investigated. The analytical tools used to perform these analyses were matrix assisted laser desorption ionization (MALDI) and laser desorption ionization (LDI) mass spectrometry. After observing that the use of the matrix (as well as the addition of Ag+) did not improve the quality of the data compared to that obtained in LDI conditions, all further measurements were performed with the latter technique. Operating under usual conditions of laser power and delay time, a very low resolution was observed, showing only macroscopic differences between the two samples in the molecular weight distribution of the different components. An accurate study on the possible reasons of this undesirable behavior indicates that it can originate from space charge phenomena occurring either in the ion source region or during the flight. A valid parameterization of the delay time and the laser power allowed higher quality spectra to be obtained. Surface-enhanced laser desorption ionization (SELDI) measurements were also performed using normal phase (silica) as the sample holder surface. Under these conditions, better results are obtained, proving that the sample-surface interaction is important to achieve, by means of laser irradiation, a homogeneous set of product ions. Both asphaltene samples were fractionated in five subfractions by gel-permeation chromatography (GPC) to obtain a better separation of the molecular weight distributions; the related spectra confirmed these findings. By using different approaches, relevant and reproducible differences between the asphaltene fractions of the two oil samples were observed.  相似文献   

8.
A new matrix-assisted laser desorption/ionization (MALDI) source for Fourier transform ion cyclotron resonance mass spectrometry (FTMS) has been developed. The new source is equipped with a hexapole ion guide. The sample on the laser target is one millimeter from the hexapole ion guide, so that ions are desorbed directly into the guide. A device for pulsing collision gas in direct proximity to the laser target makes it possible to cool the ions, which have a kinetic energy spread of several electron volts when produced by the MALDI process. These ions are trapped in the hexapole where positive potentials at the laser target and at an extraction plate help trap ions along the longitudinal axis. After a pre-defined trapping time the voltage of the extraction plate is reversed and the trapped ions are extracted for transmission to the ion cyclotron resonance cell. Accumulation of ions from multiple laser shots in the hexapole before mass spectrometric analysis increases sensitivity. Preliminary sensitivity studies with substance P show that 10 attomoles of analyte applied on the target can be detected with a signal-to-noise (S/N) ratio >15.  相似文献   

9.
Comparative MS/MS studies of singly and doubly charged electrospray ionization (ESI) and matrix-assisted laser desorption/ionization (MALDI) precursor peptide ions are described. The spectra from these experiments have been evaluated with particular emphasis on the data quality for subsequent data processing and protein/amino acid sequence identification. It is shown that, once peptide ions are formed by ESI or MALDI, their charge state, as well as the collision energy, is the main parameter determining the quality of collision-induced dissociation (CID) MS/MS fragmentation spectra of a given peptide. CID-MS/MS spectra of singly charged peptides obtained on a hybrid quadrupole orthogonal time-of-flight mass spectrometer resemble very closely spectra obtained by matrix-assisted laser desorption/ionization post-source decay time-of-flight mass spectrometry (MALDI-PSD-TOFMS). On the other hand, comparison of CID-MS/MS spectra of either singly or doubly charged ion species shows no dependence on whether ions have been formed by ESI or MALDI. This observation confirms that, at the time of precursor ion selection, further mass analysis is effectively decoupled from the desorption/ionization event. Since MALDI ions are predominantly formed as singly charged species and ESI ions as doubly charged, the associated difference in the spectral quality of MS/MS spectra as described here imposes direct consequences on data processing, database searching using ion fragmentation data, and de novo sequencing when ionization techniques are changed.  相似文献   

10.
With its highly fluctuating ion production matrix-assisted laser desorption/ionization (MALDI) poses many practical challenges for its application in mass spectrometry. Instrument tuning and quantitative ion abundance measurements using ion signal alone depend on a stable ion beam. Liquid MALDI matrices have been shown to be a promising alternative to the commonly used solid matrices. Their application in areas where a stable ion current is essential has been discussed but only limited data have been provided to demonstrate their practical use and advantages in the formation of stable MALDI ion beams. In this article we present experimental data showing high MALDI ion beam stability over more than two orders of magnitude at high analytical sensitivity (low femtomole amount prepared) for quantitative peptide abundance measurements and instrument tuning in a MALDI Q-TOF mass spectrometer. Samples were deposited on an inexpensive conductive hydrophobic surface and shrunk to droplets <10 nL in size. By using a sample droplet <10 nL it was possible to acquire data from a single irradiated spot for roughly 10,000 shots with little variation in ion signal intensity at a laser repetition rate of 5-20 Hz.  相似文献   

11.
The mechanisms responsible for matrix-assisted laser desorption/ionization (MALDI) are far from being well understood, particularly where infrared laser irradiation is used to initiate the process. We measured the emission yields and kinetic energy distributions of positive ions emitted from 2,5-dihydroxybenzoic acid loaded with angiotensin II in a standard MALDI preparation during irradiation with an infrared free-electron laser tuned to 2.94 microm. As the laser intensity is scanned through the MALDI threshold, we see a marked change in the energy distributions of the matrix ion. Above threshold, the energy distributions of both analyte and matrix cations are constant over a broad range of laser intensities. This behavior does not appear to be consistent with any extant model of the MALDI mechanism.  相似文献   

12.
The gas/phase behaviour of N-sulfonylated purine nucleic bases and nucleosides towards electron impact (EI) and matrix-assisted laser desorption/ionization (MALDI) occurring in a ion trap of a Fourier transform ion cyclotron resonance mass spectrometer is investigated. The influence of the storage time on the protonated molecule ([M+H](+)) abundance under EI conditions confirms that the formation of these ions proceeds through ion/molecule reactions. Using stored-waveform inverse Fourier transform (SWIFT) selective isolation of M(+.) or H(3)O(+), self-chemical ionization, M(+.)/M, and chemical ionization, H(3)O(+)/M, are detected. Investigation of specific EI expulsion of SO(2), SO(2)H and/or SO(2)H(2) from M(+.) and/or [M+H](+) shows that oxygen protonation in bond;SO(2)bond; proceeds faster than nitrogen protonation. Expulsion of SO(2) from molecular ions is not observed in MALDI mass spectra of nucleosides.  相似文献   

13.
The mechanism of atmospheric pressure (AP) laser ionization of water and water/glycerol liquid samples at a 3-microm wavelength is studied experimentally. For the ion desorption, an in-house built Yb : YAG-pumped optical parametric oscillator (OPO) infrared (IR) laser has been coupled with AP MALDI ion source interfaced to an ion trap mass spectrometer (MS). It has been shown that water is primarily responsible for ion generation in water/glycerol samples, while glycerol increases the solution viscosity and decreases the water evaporation rate and sample losses. In contrast to AP UV-MALDI, the electric field in the case of AP IR-MALDI does not assist in ion production. It was found that the absence of the electrical field provides the optimum ionization condition both for water and water/glycerol liquid samples at the 3-microm laser irradiation. A two-stage ion formation mechanism, which includes the initial emission of microdroplets and release of molecular ions at the second stage, can explain the experimentally observed ion signal dependencies upon the voltage applied between MS inlet and the MALDI sample plate. Postionization using additional corona discharge APCI increases the observed signal by approximately 50%, which indicates that some portion of the analyte is desorbed in the form of neutral molecules.  相似文献   

14.
Effects of sample exposure to UV laser irradiation on the matrix-assisted laser desorption—ionization (MALDI) mass spectra of different proteins are reported. The exposure is varied by irradiating the same sample spot with a differing number of UV laser pulses. The ion yield, mass resolution and internal energy content of ejected molecular ions are monitored as a function of the sample exposure. Other parameters that influence the MALDI spectra (and related to sample exposure) such as laser fluence, sample thickness, matrix-to-protein molar ratio, total deposited amount, and molecular mass of the protein, are also examined.  相似文献   

15.
A novel method was developed to measure the initial velocity of ions generated by matrix-assisted laser desorption ionization (MALDI). It is shown both experimentally and theoretically that with a delayed extraction (DE) technique, the flight time of an ion changes linearly with extraction delay. The initial velocity of the ion, a consequence of the desorption process, can be determined from the slope of this linear curve. Systematic study of the initial velocity was undertaken regarding its dependence on the matrix substance, molecular weight of the analyte, ion polarity, and wavelength of irradiation. It was found that the most important factor was the matrix material. Sinapinic acid and α-cyano-4-hydroxycinnamic acid matrices ejected slower peptide and protein ions than 2,5-dihydroxybenzoic acid or 3-hydroxypicolinic acid: ~ 300 versus ~ 550 m/s. Matrix ions themselves exhibited a similar order of initial velocities, but these were 15–40% higher than those of insulin ions. The molecular weight of protein samples (between 5 and 25 ku) was found to have little effect on the initial velocity, but for peptides below 5 ku a gradual transition was noted toward the velocity of the matrix ions. Also decreasing velocity with increasing molecular mass was observed for DNA samples in the 4–14-ku range. In the negative ion mode slightly lower velocities were observed than in the positive ion mode. No difference was found between 337- and 266-nm irradiation. Values of the initial velocities were used to correct systematic errors in the internal calibration observed in mass spectra with delayed extraction. These velocity corrections decrease mass errors substantially in the linear mode, in particular for multicomponent mixtures.  相似文献   

16.
Reduction of analytes in matrix-assisted laser desorption/ionization (MALDI) often obscures the actual determination of molecular structure. To address the redox reactions in laser desorption/ionization processes, the organic dyes Methylene Blue, Janus Green B, Crystal Violet and Rhodamine B were analyzed by MALDI or by desorption/ionization on porous silicon (DIOS). Susceptibility to reduction in MALDI was dependent on both the reduction potentials of analytes and the molar ratio of analyte to matrix molecules. Addition of Cu(II) ions as an electron scavenger suppressed the reduction of Methylene Blue in MALDI. The results suggested that electron transfer to analytes from the sample target and/or from the matrix contributed to the reduction. In DIOS, the reductions of organic dyes were more prominent than in MALDI, and were not prevented by Cu(II) ion doping, probably due to direct contact of the analytes with silicon which had little electric resistance.  相似文献   

17.
Tong H  Sze N  Thomson B  Nacson S  Pawliszyn J 《The Analyst》2002,127(9):1207-1210
Solid phase microextraction (SPME) with matrix assisted laser desorption/ionization (MALDI) introduction was coupled to mass spectrometry and ion mobility spectrometry. Nicotine and myoglobin in matrix 2,5-dihydroxybenzonic acid (DHB), enkephalin and substance P in alpha-cyano-4-hydroxy cinnaminic acid were investigated as the target compounds. The tip of an optical fiber was silanized for extraction of the analytes of interest from solution. The optical fiber thus served as the sample extraction surface, the support for the sample plus matrix, and the optical pipe to transfer the laser energy from the laser to the sample. The MALDI worked under atmospheric pressure, and both an ion mobility spectrometer and a quadrupole/time-of-flight mass spectrometer were used for the detection of the SPME/MALDI signal. The spectra obtained demonstrate the feasibility of the SPME with MALDI introduction to mass spectrometry instrumentation.  相似文献   

18.
Energy transfer (ET) from excited matrix to fluorescent traps is used to probe the mobility of excitations in the matrix-assisted laser desorption/ionization (MALDI) matrix material 2,5-dihydroxybenzoic acid. The dependence of host and guest fluorescence on excitation density (laser intensity) and trap concentration gives clear evidence for long-range energy transport in this matrix. This conclusion is further supported by time-resolved emission data showing a 2 ns delay between matrix and trap emission. Rate equation and random walker models give good agreement with the data, allowing determination of hopping, collision, and trapping parameters. Long-range energy transfer contributes to the pooling reactions which can lead to primary ions in MALDI. The results validate the pooling aspect of the prior quantitative MALDI ionization model (J. Mass Spectrom. 2002, 37, 867-877). It is shown that exciton trapping can decrease MALDI ion yield, even at low trap concentration.  相似文献   

19.
A novel quadrupole ion trap mass spectrometer laser microprobe instrument with an external ionization source was constructed and used to investigate the matrix-assisted laser desorption/ionization (MALDI) detection of pharmaceutical compounds in intact tissue. In addition to MALDI, laser desorption coupled with chemical ionization (LD/CI) was investigated. MALDI, using 2,5-dihydroxybenezoic acid (DHB) as a matrix, was employed to detect the anticancer drug paclitaxel from a thin section of rat liver tissue which had been incubated in a solution of paclitaxel. The results of that experiment showed that the ability to perform tandem mass spectrometry (MS/MS) with the quadrupole ion trap was crucial in the identification of drug compounds at trace levels in the complex tissue matrix. MALDI MS/MS was then used to detect the presence of paclitaxel in a human ovarian tumor at a concentration of approximately 50 mg/kg. Finally, the drug spiperone was detected in incubated rat liver tissue at an approximate level of 25 mg/kg using LD/CI (no MALDI matrix). Again, the MS/MS capability of the quadrupole ion trap was crucial in the identification of the drug at trace levels in the complex tissue matrix.  相似文献   

20.
We report here the first application of laser desorption (LD) in transmission geometry (backside irradiation of the sample through a transparent support) inside a Fourier-transform ion cyclotron resonance mass spectrometer (FT-ICR). A probe-mounted fiber optic assembly was used to simplify the implementation of this LD technique. This setup requires little or no instrument modifications, has minimum maintenance requirements, and is relatively inexpensive to build. The performance of the probe was tested by determining the molecular weight of a commercial polystyrene standard from its matrix-assisted laser desorption/ionization (MALDI) spectrum. The measured average molecular weight is comparable to that obtained for the same sample by MALDI in the conventional top-illumination arrangement (reflection geometry) and by the manufacturer of the sample by gel permeation chromatography. The average velocities measured for ions evaporated by transmission mode LD of several neat samples are about half the velocity of those obtained by using the reflection geometry. Therefore, transmission mode irradiation of the sample holds promise to desorb ions that are easier to trap in an ICR cell. An oscillating capillary nebulizer was adapted for the deposition of analytes to improve sampling reproducibility.  相似文献   