首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
郭各朴  张春兵  屠娟  章东 《物理学报》2015,64(11):114301-114301
包膜黏弹特性显著影响微气泡超声造影剂的诊断及治疗应用效果. 本文结合原子力显微镜技术及声衰减特性测量提出了一种对微气泡造影剂包膜黏弹特性定量表征的新方法. 首先采用原子力显微镜技术进行机械特性分析得到包膜微气泡的有效硬度及体弹性模量; 然后测量声衰减特性, 基于微气泡动力学理论, 计算包膜微气泡的体黏度系数. 为验证方法的有效性, 实验制备了直径为1-5 μm的白蛋白包膜微气泡造影剂, 原子力显微镜测量的有效硬度和体弹性模量分别为0.149±0.012 N/m和8.31±0.667 MPa, 并与粒径无关. 声衰减特性测量和动力学理论拟合的包膜微气泡的体黏度系数为0.374±0.003 Pa·s. 该方法可推广至其他种类包膜微气泡的黏弹特性表征, 对超声造影剂的制备及其诊断和治疗应用有积极意义.  相似文献   

2.
The focus of contrast-enhanced ultrasound research has developed beyond visualizing the blood pool and its flow to new areas such as perfusion imaging, drug and gene therapy, and targeted imaging. In this work comparison between the application of polymer- and phospholipid-shelled ultrasound contrast agents (UCAs) for characterization of the capillary microcirculation is reported. All experiments are carried out using a microtube as a vessel phantom. The first set of experiments evaluates the optimal concentration level where backscattered signal from microbubbles depends on concentration linearly. For the polymer-shelled UCAs the optimal concentration level is reached at a value of about 2 × 104 MB/ml, whereas for the phospholipid-shelled UCAs the optimal level is found at about 1 × 105 MB/ml.Despite the fact that the polymer shell occupies 30% of the radius of microbubble, compared to 0.2% of the phospholipid-shelled bubble, approximately 5-fold lower concentration of the polymer UCA is needed for investigation compared to phospholipid-shelled analogues. In the second set of experiments, destruction/replenishment method with varied time intervals ranging from 2 ms to 3 s between destructive and monitoring pulses is employed. The dependence of the peak-to-peak amplitude of backscattered wave versus pulse interval is fitted with an exponential function of the time γ = A(1 − exp(−βt)) where A represents capillary volume and the time constant β represents velocity of the flow. Taking into account that backscattered signal is linearly proportional to the microbubble concentration, for both types of the UCAs it is observed that capillary volume is linearly proportional to the concentration of the microbubbles, but the estimation of the flow velocity is not affected by the change of the concentration. Using the single capillary model, for the phospholipid-shelled UCA a delay of about 0.2-0.3 s in evaluation of the perfusion characteristics is found while polymer-shelled UCA provide response immediately. The latter at the concentration lower than 3.6 × 105 MB/ml have no statistically significant delay (< 0.01), do not cause any attenuation of the backscattered signal or saturation of the receiving part of the system. In conclusion, these results suggest that the novel polymer-shelled microbubbles have a potential to be used for perfusion evaluation.  相似文献   

3.
Sonoporation uses ultrasound, with the aid of ultrasound contrast agents (UCAs), to enhance cell permeabilization, thereby allowing delivery of therapeutic compounds noninvasively into specific target cells. The objective of this study was to determine if a computational model describing shear stress on a cell membrane due to microstreaming would successfully reflect sonoporation activity with respect to the peak rarefactional pressure. The theoretical models were compared to the sonoporation results from Chinese hamster ovary cells using Definity(?) at 0.9, 3.15, and 5.6 MHz and were found to accurately describe the maximum sonoporation activity, the pressure where a decrease in sonoporation activity occurs, and relative differences between maximum activity and the activity after that decrease. Therefore, the model supports the experimental findings that shear stress on cell membranes secondary to oscillating UCAs results in sonoporation.  相似文献   

4.
滕旭东  郭霞生  屠娟  章东 《中国物理 B》2016,25(12):124308-124308
Modelling and biomedical applications of ultrasound contrast agent(UCA) microbubbles have attracted a great deal of attention. In this review, we summarize a series of researches done in our group, including(i) the development of an all-in-one solution of characterizing coated bubble parameters based on the light scattering technique and flow cytometry;(ii) a novel bubble dynamic model that takes into consideration both nonlinear shell elasticity and viscosity to eliminate the dependences of bubble shell parameters on bubble size;(iii) the evaluation of UCA inertial cavitation threshold and its relationship with shell parameters; and(iv) the investigations of transfection efficiency and the reduction of cytotoxicity in gene delivery facilitated by UCAs excited by ultrasound exposures.  相似文献   

5.
Beyond a characteristic value of the negative peak pressure, ultrasound fracture the shell of ultrasonic contrast agents (UCAs). Existing criteria for ascertaining this threshold value exploit the dependence of the amplitude of the UCA acoustic response on the incident pressure. However, under the common experimental conditions used in this work, these criteria appear to be unreliable when they are applied to UCAs that are stabilized by a thick polymeric shell. An alternative criterion for determining the onset of shell fracture is introduced here, which uses variations of the shape of the acoustic time-domain response of an UCA suspension. Experimental evidence is presented that links the changes of the cross-correlation coefficient between consecutive time-domain signals to the fracture of the shells, and consequent release of air microbubbles. In principle, this criterion may be used to characterize similar properties of other types of particles that cannot undergo inertial cavitation.  相似文献   

6.
王焕磊  范鹏飞  郭霞生  屠娟  马勇  章东 《中国物理 B》2016,25(12):124314-124314
Transdermal drug delivery(TDD) can effectively bypass the first-pass effect. In this paper, ultrasound-facilitated TDD on fresh porcine skin was studied under various acoustic parameters, including frequency, amplitude, and exposure time. The delivery of yellow–green fluorescent nanoparticles and high molecular weight hyaluronic acid(HA) in the skin samples was observed by laser confocal microscopy and ultraviolet spectrometry, respectively. The results showed that,with the application of ultrasound exposures, the permeability of the skin to these markers(e.g., their penetration depth and concentration) could be raised above its passive diffusion permeability. Moreover, ultrasound-facilitated TDD was also tested with/without the presence of ultrasound contrast agents(UCAs). When the ultrasound was applied without UCAs,low ultrasound frequency will give a better drug delivery effect than high frequency, but the penetration depth was less likely to exceed 200 μm. However, with the help of the ultrasound-induced microbubble cavitation effect, both the penetration depth and concentration in the skin were significantly enhanced even more. The best ultrasound-facilitated TDD could be achieved with a drug penetration depth of over 600 μm, and the penetration concentrations of fluorescent nanoparticles and HA increased up to about 4–5 folds. In order to get better understanding of ultrasound-facilitated TDD, scanning electron microscopy was used to examine the surface morphology of skin samples, which showed that the skin structure changed greatly under the treatment of ultrasound and UCA. The present work suggests that, for TDD applications(e.g., nanoparticle drug carriers, transdermal patches and cosmetics), protocols and methods presented in this paper are potentially useful.  相似文献   

7.
Ultrasonic attenuation is important not only as a parameter for characterizing tissue but also for compensating other parameters that are used to classify tissues. Several techniques have been explored for estimating ultrasonic attenuation from backscattered signals. In the present study, a technique is developed to estimate the local ultrasonic attenuation coefficient by analyzing the time domain backscattered signal. The proposed method incorporates an objective function that combines the diffraction pattern of the source/receiver with the attenuation slope in an integral equation. The technique was assessed through simulations and validated through experiments with a tissue mimicking phantom and fresh rabbit liver samples. The attenuation values estimated using the proposed technique were compared with the attenuation estimated using insertion loss measurements. For a data block size of 15 pulse lengths axially and 15 beamwidths laterally, the mean attenuation estimates from the tissue mimicking phantoms were within 10% of the estimates using insertion loss measurements. With a data block size of 20 pulse lengths axially and 20 beamwidths laterally, the error in the attenuation values estimated from the liver samples were within 10% of the attenuation values estimated from the insertion loss measurements.  相似文献   

8.
蔡晨亮  屠娟  郭霞生  章东 《声学学报》2019,44(4):772-779
关于多气泡相互作用的理论研究对于深入理解超声造影剂在医疗领域中的应用机理具有重要意义。本工作建立了一个2维轴对称有限元模型来研究流体环境中超声造影剂双气泡相互作用,讨论了驱动超声频率和气泡尺寸对气泡之间吸引和排斥趋势的影响,得到了气泡半径与气泡之间距离随时间变化的曲线,以及气泡周围流体速度场的细节,并且研究了气泡包膜参数(即表面张力系数和粘度系数)对气泡相互作用的影响.结果表明,相互作用中的气泡对整体的相对运动趋势由驱动频率和共振频率之间的关系决定;在超声参数固定时,气泡包膜的粘弹特性可用来调控气泡间相互作用强度。结果对实验中观察到的气泡聚集现象进行了合理解释,并为超声造影剂在医疗实践中的应用提供了基础理论支撑.   相似文献   

9.
A generation of tissue-specific stable ultrasound contrast agent (UCA) composed of a polymeric capsule with a perfluorocarbone liquid core has become available. Despite promising uses in clinical practice, the acoustical behavior of such UCA suspensions remains unclear. A simulation code (2-D finite-difference time domain, FDTD) already validated for homogeneous particles [Galaz Haiat, Berti, Taulier, Amman and Urbach, (2010). J. Acoust. Soc. Am. 127, 148-154] is used to model the ultrasound propagation in such UCA suspensions at 50 MHz to investigate the sensitivity of the ultrasonic parameters to physical parameters of UCA. The FDTD simulation code is validated by comparison with results obtained using a shell scatterer model. The attenuation coefficient (respectively, the sound velocity) increases (respectively, decreases) from 4.1 to 58.4 dB/cm (respectively, 1495 to 1428 m/s) when the concentration varies between 1.37 and 79.4 mg/ml, while the backscattered intensity increases non-linearly, showing that a concentration of around 30 mg/ml is sufficient to obtain optimal backscattering intensity. The acoustical parameters vary significantly as a function of the membrane thickness, longitudinal and transverse velocity, indicating that mode conversions in the membrane play an important role in the ultrasonic propagation. The results may be used to help manufacturers to conceive optimal liquid-filled UCA suspensions.  相似文献   

10.
A new indirect measurement concept is developed to estimate interfacial dynamic forces by employing the hydraulic mount as a dynamic force sensor. The proposed method utilizes a combination of mathematical models and operating motion and/or pressure measurements. A laboratory experiment consisting of a powertrain, three powertrain mounts (including a dynamic load sensing hydraulic mount), a sub-frame, and four bushings is then constructed to verify the proof-of-concept. Quasi-linear fluid and mechanical system models of the experiment are proposed and evaluated in terms of transfer functions and forced sinusoidal responses. The lower chamber pressure in the hydraulic mount is estimated since it is not available from measurements. This leads to an improved estimation of the effective rubber and hydraulic path parameters with spectrally varying and amplitude-sensitive properties up to 50 Hz. Finally, the reverse path spectral method is employed to predict interfacial forces at both ends of the mount by using measured motions and upper chamber pressure signals. Overall, the proposed quasi-linear fluid system model yields better indirect estimates of forces from the measured responses when compared with direct force measurements, through a simpler mechanical system model provides some insights. This work also advances prior component and transfer path type studies by providing an improved multi-degree of freedom system perspective.  相似文献   

11.
Laboratory measurements of high-frequency broadband acoustic backscattering (200-600 kHz) from the diffusive regime of double-diffusive microstructure have been performed. This type of microstructure, which was characterized using direct microstructure and optical shadowgraph techniques, is identified by sharp density and sound speed interfaces separating well-mixed layers. Vertical acoustic backscattering measurements were performed for a range of physical parameters controlling the double-diffusive microstructure. The echoes have been analyzed in both the frequency domain, providing information on the spectral response of the scattering, and in the time domain, using pulse compression techniques. High levels of variability were observed, associated with interface oscillations and turbulent plumes, with many echoes showing significant spectral structure. Acoustic estimates of interface thickness (1-3 cm), obtained for the echoes with exactly two peaks in the compressed pulse output, were in good agreement with estimates based on direct microstructure and optical shadowgraph measurements. Predictions based on a one-dimensional weak-scattering model that includes the actual density and sound speed profiles agree reasonably with the measured scattering. A remote-sensing tool for mapping oceanic microstructure, such as high-frequency broadband acoustic scattering, could lead to a better understanding of the extent and evolution of double-diffusive layering, and to the importance of double diffusion to oceanic mixing.  相似文献   

12.
Ultrasound contrast agents (UCAs) are frequently added into the focused ultrasound field as cavitation nuclei to enhance the therapeutic efficiency. Since their presence will distort the pressure field and make the process unpredictable, comprehension of their behaviors especially the active zone spatial distribution is an important part of better monitoring and using of UCAs. As shell materials can strongly alter the acoustic behavior of UCAs, two different shells coated UCAs, lipid-shelled and polymer-shelled UCAs, in a 1.2 MHz focused ultrasound field were studied by the Sonochemiluminescence (SCL) method and compared.The SCL spatial distribution of lipid-shelled group differed from that of polymer-shelled group. The shell material and the character of focused ultrasound field work together to the SCL distribution, causing the lipid-shelled group to have a maximum SCL intensity in pre-focal region at lower input power than that of polymer-shelled group, and a brighter SCL intensity in post-focal region at high input power. The SCL inactive area of these two groups both increased with the input power. The general behavior of the UCAs can be studied by both the average SCL intensity and the backscatter signals. As polymer-shelled UCAs are more resistant to acoustic pressure, they had a higher destruction power and showed less reactivation than lipid-shelled ones.  相似文献   

13.
This paper describes geoacoustic inversion of low frequency air gun data acquired during an experiment on the New Jersey shelf. Hybrid optimization and Bayesian inversion techniques based on matched field processing were applied to multiple shots from three air gun data sets recorded by a vertical line array in a long-range shallow water geometry. For the Bayesian inversions, full data error covariance matrix was estimated from a set of consecutive shots that had high temporal coherence and small spatial variation in source position. The effect of different data error information on the geoacoustic parameter uncertainty estimates was investigated by using the full data error covariance matrix, a diagonalized version of the full error covariance, and a diagonal matrix with identical variances. The comparison demonstrated that inversion using the full data error information provided the most reliable parameter uncertainty estimates. The inversions were highly sensitive to the near sea floor geoacoustic parameters, including sediment attenuation, of a simple single-layer geoacoustic model. The estimated parameter values of the model were consistent with depth averaged values (over wavelength scales) of a high resolution geoacoustic model developed from extensive ground truth information. The interpretation of the frequency dependence of the estimated attenuation is also discussed.  相似文献   

14.
Ultrasound contrast agents (UCAs) are used clinically to aid detection and diagnosis of abnormal blood flow or perfusion. Characterization of UCAs can aid in the optimization of ultrasound parameters for enhanced image contrast. In this study echogenic liposomes (ELIPs) were characterized acoustically by measuring the frequency-dependent attenuation and backscatter coefficients at frequencies between 3 and 30 MHz using a broadband pulse-echo technique. The experimental methods were initially validated by comparing the attenuation and backscatter coefficients measured from 50-μm and 100-μm polystyrene microspheres with theoretical values. The size distribution of the ELIPs was measured and found to be polydisperse, ranging in size from 40 nm to 6 μm in diameter, with the highest number observed at 65 nm. The ELIP attenuation coefficients ranged from 3.7 ± 1.0 to 8.0 ± 3.3 dB/cm between 3 and 25 MHz. The backscatter coefficients were 0.011 ± 0.006 (cm str)(-1) between 6 and 9 MHz and 0.023?±?0.006 (cm str)(-1) between 13 and 30 MHz. The measured scattering-to-attenuation ratio ranged from 8% to 22% between 6 and 25 MHz. Thus ELIPs can provide enhanced contrast over a broad range of frequencies and the scattering properties are suitable for various ultrasound imaging applications including diagnostic and intravascular ultrasound.  相似文献   

15.
Detection procedures of ultrasound contrast agents   总被引:8,自引:0,他引:8  
In the early days, it was believed that ultrasound contrast agents (UCA) could be sufficiently detected and imaged with the conventional imaging methods nowadays referred to as fundamental imaging. Newer imaging techniques proved to be more sensitive and are based on specific properties of the UCA. In general, these new characteristics involve non-linear and transient characteristics of contrast agents that appear at the high end of the diagnostic acoustic intensity. Imaging modalities used today for UCA are, besides fundamental imaging, second harmonic imaging, power Doppler, harmonic power Doppler, pulse inversion and pulse inversion Doppler, multi-pulse imaging and subharmonic imaging. Although the results of conventional second harmonic imaging are still not optimal for perfusion imaging applications, in combination with Doppler techniques (colour Doppler, power Doppler) it is one of the most sensitive techniques currently available in terms of agent-to-tissue ratio. Further improvements in current and future detection methods demand a complete understanding of the ultrasound-UCA interaction.  相似文献   

16.
This work investigates the radiation damage on the eye of albino mice exposed to effective radon doses ranging from 20.92 to 83.68 mSv. These doses were taken over 2–8 weeks using a radon chamber constructed by the National Institute for Standard (Egypt). The guidance on the quality assurance program for radon measurements was followed. Therefore, the estimated doses received by the laboratory animals meet the requirements of national standard. The refractive index(RI) and protein concentration were measured for soluble proteins of both corneas and lenses. In addition, the sodium dodecyle sulfate polyacrylamide gel electrophoresis (SDSPAGE) technique was used. The results show increasing of the RI of both cornea and lens proteins and decreasing in total protein concentration of exposed animals. These results were accompanied with changes in the SDSPAGE profile for both cornea and lens. Therefore, radon exposure produces substantial hazards to the cornea and lens of experimental animals and has a crucial role in the development of cataract and corneal opacity.  相似文献   

17.
《Radiation measurements》2008,43(8):1396-1401
Standardization of the thoron exhalation measurements is important for the intercomparison of the results among different laboratories. There are a few important distinctions between thoron (220Rn) and radon (222Rn) exhalation measurements using an accumulation chamber, due to a great difference between radon and thoron diffusion lengths in air, namely, short diffusion length of thoron indicates that it is very hard to attain homogenous distribution of the thoron concentration in an accumulation chamber of the usual dimensions, which is often neglected. It will be explained that the same model cannot be used both for radon and for thoron exhalation measurements. The results of the thoron exhalation measurements also depend on the sample thickness which must be considered. A new method for thoron exhalation measurement using an accumulation chamber is proposed. Comparisons between the existing and the proposed methods were performed on five different samples.  相似文献   

18.
Tracking of individual fish targets using a split-beam echosounder is a common method for investigating fish behavior. When mounted on a floating platform like a ship or a buoy, the transducer movement often complicates the process. This paper presents a framework for tracking single targets from such a platform. A filter based on the correlated fish movements between pings is developed to estimate the platform movement, and an extended Kalman filter is used to combine the split-beam measurements and the platform-position estimates. Different methods for gating and data association are implemented and tested with respect to data-association errors, using manually tracked data from a free-floating buoy as a reference. The data association was improved by utilizing the estimated velocity for each track to predict the location of the next observation. The data association was more robust when estimates of platform tilt/roll were used. Other techniques to estimate position and velocity, like linear regression and smoothing splines, were implemented and tested on a simulated data set. The platform-state estimation improved the estimates for methods like the Kalman filter and a smoothing spline with cross validation, but not for robust methods like linear regression and smoothing spline with a fixed degree of smoothing.  相似文献   

19.
An historical survey of the techniques of measurement and assessment of anechoic chambers is given with a view to deciding the optimum method of evaluating the new anechoic chamber at Bradford University. Experimental results taken on the chamber, using the inverse distance and frequency response tests, are presented. An attempt is made to correlate the results of these tests with predicted results obtained from steady-state measurements taken, in an interference tube, on the novel type of absorber used in the chamber. In conclusion, guidelines for the design of small anechoic chambers are given.  相似文献   

20.
Trevor Fenner  George Loizou 《Physica A》2010,389(12):2416-2421
The concept of the long tail has recently been used to explain the phenomenon in e-commerce where the total volume of sales of the items in the tail is comparable to that of the most popular items. In the case of online book sales, the proportion of tail sales has been estimated using regression techniques on the assumption that the data obeys a power-law distribution. Here we propose a different technique for estimation based on a generative model of book sales that results in an asymptotic power-law distribution of sales, but which does not suffer from the problems related to power-law regression techniques. We show that the proportion of tail sales predicted is very sensitive to the estimated power-law exponent. In particular, if we assume that the power-law exponent of the cumulative distribution is closer to 1.1 rather than to 1.2 (estimates published in 2003, calculated using regression by two groups of researchers), then our computations suggest that the tail sales of Amazon.com, rather than being 40% as estimated by Brynjolfsson, Hu and Smith in 2003, are actually closer to 20%, the proportion estimated by its CEO.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号