首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
A sensitive and reliable method was developed to determine methylene blue (MB) and its metabolite residues, including azure A (AZA), azure B (AZB), and azure C (AZC) in aquatic products by HPLC–MS/MS. The samples were extracted by acetonitrile and cleaned up by alumina-neutral (ALN) cartridges. The analytes were separated on a Sunfire C18 column (150 mm × 2.1 mm, 5 µm). The method was validated according to the European criteria of Commission Decision 2002/657/CE. Good linearity between 1–500 µg/L was obtained with correlation coefficients (R2) greater than 0.99. The limit of quantification (LOQ) was 1.0 µg/kg. The average recoveries at three levels of each compound (1, 5, and 10 µg/kg) were demonstrated to be in the range of 71.8–97.5%, with relative standard deviations (RSDs) from 1.05% to 8.63%. This method was suitable for the detection of methylene blue and its metabolite residues in aquatic products.  相似文献   

2.
In this study we present a high-performance liquid chromatography/tandem mass spectrometry (HPLC/MS/MS) method which has been elaborated to analyse steroid hormones, hormone conjugates, oral contraceptives and macrolide antibiotics unchanged in unfiltered influents and effluents of sewage treatment plants (STPs). HPLC separation of the steroid hormones was achieved in 35 min, as well as those of the antibiotics. The analytes were extracted by solid-phase extraction, followed by clean-up using size exclusion chromatography (SEC). For the final quantification HPLC/MS/MS was used. The two ionisation modes, electrospray ionisation (ESI) and atmospheric pressure chemical ionisation (APCI), in HPLC/MS/MS were compared for the analysis of steroid hormones. For quantitative results drastic matrix effects were observed while using ESI. These effects were less pronounced while using APCI. These pitfalls were additionally reduced by clean-up using SEC as well as isotope dilution. Additionally, two multiple reaction monitoring (MRM) transitions per compound were used to prevent false positive results. Recovery experiments with spiked tap water with concentrations varying from 1 to 1000 ng/L gave constant recovery rates: The recovery rates for the hormones and conjugates ranged from 58 to 107%, those of the contraceptives ranged from 83 to 109%. The relative standard deviation was found to be 7 to 24% and the limits of detection were 0.1 to 4.5 ng/L. The recovery rates of the macrolide antibiotics ranged from 76 to 103%, while the relative standard deviation was found to be 7 to 14% and the limits of detection ranged from 0.6 to 1.8 ng/L. The maximum concentrations found in influents of a STP was 470 ng/L for estriol and 1200 ng/L for erythromycin.  相似文献   

3.
A new, simple and sensitive method for isolating nine compounds from the bisphenol group (analogues: A, B, C, E, F, G, Cl2, Z, AP) based on one-step liquid–liquid microextraction with in situ acylation followed by gas chromatography-mass spectrometry was developed and validated using influent and effluent wastewaters. The chemometric approach based on the Taguchi method was used to optimize the main conditions of simultaneous extraction and derivatization. The recoveries of the proposed procedure ranged from 85 to 122%, and the repeatability expressed by the coefficient of variation did not exceed 8%. The method’s limits of detection were in the range of 0.4–64 ng/L, and the method’s limits of quantification ranged from 1.3 to 194 ng/L. The developed method was used to determine the presence of the tested compounds in wastewater from a municipal wastewater treatment plant located in northeastern Poland. From this sample, eight analytes were detected. Concentrations of bisphenol A of 400 ng/L in influent and 100 ng/L in effluent were recorded, whereas other bisphenols reached 67 and 50 ng/L for influent and effluent, respectively. The removal efficiency of bisphenol analogues in the tested wastewater treatment plant ranged from 7 to approximately 88%.  相似文献   

4.
Gungha-tang (GHT), a traditional herbal medicine, consists of nine medicinal herbs (Cnidii Rhizoma, Pinelliae Tuber, Poria Sclerotium, Citri Unshius Pericarpium, Citri Unshius Pericarpium Immaturus, Aurantii Fructus Immaturus, Atracylodis Rhizoma Alba, Glycyrrhizae Radix et Rhizoma, and Zingiberis Rhizoma Recens). It has been used for various diseases caused by phlegm. This study aimed to develop and verify the simultaneous liquid chromatography–tandem mass spectrometry (LC–MS/MS) analysis method, using nine marker components (liquiritin apioside, neoeriocitrin, narirutin, naringin, hesperidin, neohesperidin, liquiritigenin, glycyrrhizin, and 6-shogaol) for quality control of GHT. LC–MS/MS analysis was conducted using a Waters TQ-XS system. All marker analytes were separated on a Waters Acquity UPLC BEH C18 column (2.1 × 100 mm, 1.7 μm) using gradient elution with a distilled water solution (containing 5 mM ammonium formate and 0.1% [v/v] formic acid)–acetonitrile mobile phase. LC–MS/MS multiple reaction monitoring (MRM) analysis was carried out in negative and positive ion modes of an electrospray ionization source. The developed LC–MS/MS MRM method was validated by examining the linearity, limits of detection and quantification, recovery, and precision. LOD and LOQ values of nine markers were calculated as 0.02–8.33 ng/mL and 0.05–25.00 ng/mL. The recovery was determined to be 89.00–118.08% and precision was assessed with a coefficient of variation value of 1.74–8.64%. In the established LC–MS/MS MRM method, all markers in GHT samples were detected at 0.003–16.157 mg/g. Information gathered during the development and verification of the LC–MS/MS method will be useful for the quality assessment of GHT and other herbal medicines.  相似文献   

5.
Accurate measurement of sulfated steroid metabolite concentrations can not only enable the elucidation of the mechanisms regulating steroid metabolism, but also lead to the diagnosis of various related diseases. The present study describes a simple and sensitive method for the simultaneous determination of four sulfated steroid metabolites in saliva, pregnenolone sulfate (PREGS), dehydroepiandrosterone sulfate (DHEAS), cortisol sulfate (CRTS), and 17β-estradiol-3-sulfate (E2S), by online coupling of in-tube solid-phase microextraction (IT-SPME) and stable isotope dilution liquid chromatography–tandem mass spectrometry (LC–MS/MS). These compounds were extracted and concentrated on Supel-Q PLOT capillary tubes by IT-SPME and separated and detected within 6 min by LC–MS/MS using an InertSustain swift C18 column and negative ion mode multiple reaction monitoring systems. These operations were fully automated by an online program. Calibration curves using their stable isotope-labeled internal standards showed good linearity in the range of 0.01–2 ng mL−1 for PREGS, DHEAS, and CRTS and of 0.05–10 ng mL−1 for E2S. The limits of detection (S/N = 3) of PREGS, DHEAS, CRTS, and E2S were 0.59, 0.30, 0.80, and 3.20 pg mL−1, respectively. Moreover, intraday and interday variations were lower than 11.1% (n = 5). The recoveries of these compounds from saliva samples were in the range of 86.6–112.9%. The developed method is highly sensitive and specific and can easily measure sulfated steroid metabolite concentrations in 50 μL saliva samples.  相似文献   

6.
An ultra-high performance liquid chromatography tandem mass spectrometry method was developed and validated for the sensitive determination and unambiguous confirmation of residues of per and polyfluorinated alkyl substances (PFAS) in breastmilk, retail milk and infant formulas following two sample preparation methods. Sample pre-treatment was carried out by a simplified QuEChERS method without requiring dSPE or any further clean-up. The method was validated in accordance with the requirements of Commission Decision 657/2002/EC with slight modifications. The method displayed good linearity with R2 ranging from 0.9843–0.9998 for all target PFAS. The recovery and within-laboratory reproducibility of the method (n = 63) were in the range 60–121% and 5–28%, respectively. The decision limit, detection capability and limit of quantitation ranged from 30–60 ng kg−1 to 40–100 ng kg−1 and 5–50 ng kg−1, respectively. Acceptable matrix effect values in the range −45–29% were obtained with uncertainty of measurement lower than 25% for all target PFAS. The method displays its suitability for the sensitive and high-throughput confirmatory analysis of C4–C14 PFAS in breastmilk, dairy milk and infant formulas.  相似文献   

7.
This article presents the development, validation and application of a new multi-residue method for simultaneous determination of 36 pharmaceuticals (histamine receptor antagonists, psychoactive stimulant, antiepileptics, antihypertensive, non-steroidal anti-inflammatory, analgesic and antipyretic, lipid regulator, antibiotics, antibacterial, skin care ingredient and metabolites of nicotine and lipid regulators) in surface water using solid phase extraction (Strata-X at pH 5) and liquid chromatography-tandem mass spectrometry (LC–MS/MS). Recoveries were greater than 70% with less than 20% SD for the majority of analytes. The instrumental quantification limit was between 2 and 181 pg, and method quantification limit varied from 0.5 to 98 ng L?1 in spiked stream water. The pH and sorbent dependence of matrix effects is discussed. The optimised method was used to determine the occurrence of target analytes in surface water from the coastal Lake Erie in Oregon, northwest Ohio. Seventeen analytes were detected with concentrations up to hundreds of nanogram per litre in stream and lake water samples.  相似文献   

8.
An analytical method that enables detection and quantification of bromophenols (BPs) at taste threshold concentrations (2,6-DBP: 0.5 ng/L) was developed. This method involves conversion of the BPs to their acetates, followed by isolation of the acetates by a modified purge-and-trap procedure, and analysis by gas chromatography-mass spectrometry (GC-MS) in selected ion monitoring (SIM) mode. Bromophenyl acetates were synthesized so that each of the two steps in the method could be developed and optimised in isolation to the other. Deuterated BPs (phenol-d5, 2-BP-d4, 4-BP-d2, 2,6-DBP-d3, 2,4-DBP-d3 and 2,4,6-TBP-d2) were synthesized to enable quantification of analytes using the deuterated analogues of analytes as internal standards. This method allowed quantification of BPs at concentrations ranging from the detection limits (3 ng/L for phenol and 0.1-0.5 ng/L for each of the BPs) to 1000 ng/L for each analyte, with repeatabilities of < or =14% (RSD) for concentrations of 1 ng/L and < or =9% (RSD) for concentrations of 10-1000 ng/L, with recoveries ranging from 91 to 97%.  相似文献   

9.
An iron‐embedded porous carbon material (MIL‐53‐C) was fabricated by the direct carbonization of MIL‐53. The MIL‐53‐C possesses a high surface area and good magnetic behavior. The structure, morphology, magnetic property, and porosity of the MIL‐53‐C were studied by scanning electron microscopy, transmission electron microscopy, vibrating sample magnetometry, and N2 adsorption. With the use of MIL‐53‐C as the magnetic solid‐phase extraction adsorbent, a simple and efficient method was developed for the magnetic solid‐phase extraction of three hormones from water and human urine samples before high‐performance liquid chromatography with UV detection. The developed method exhibits a good linear response in the range of 0.02–100 ng/mL for water and 0.5–100 ng/mL for human urine samples , respectively. The limit of detection (S/N = 3) for the analytes was 0.005–0.01 ng/mL for water sample and 0.1–0.3 ng/mL for human urine sample. The limit of quantification (S/N = 10) of the analytes were in the range of 0.015–0.030 and 0.3–0.9 ng/mL, respectively.  相似文献   

10.
A new, fast and simple analytical method that is able to identify and quantify simultaneously 17 steroid hormones and metabolites (pregnenolone, 17‐OH‐pregnenolone, progesterone, 17‐OH‐progesterone, androsterone, androstenedione, dehydroepiandrosterone, dehydroepiandrosterone sulfate, testosterone, cortisol, corticosterone, aldosterone, 11‐deoxycortisol, 11‐deoxycorticosterone, dihydrotestosterone, estrone and estradiol) has been developed in equine serum using the ultra‐high‐performance liquid chromatography–tandem mass spectrometry technique. A total of 400 µl of sample was deproteinized with 1000 µl of acetonitrile, evaporated, restored with 50 µl of a solution of 25% methanol and injected in ultra‐high‐performance liquid chromatography–tandem mass spectrometry triple quadrupole. The recovery percentage obtained by spiking the matrix at two different concentrations with a standard mixture of steroid hormones was in all cases higher than 85.60% and with the percentage of coefficient of variation lower than 8.37%. The range of the correlation coefficients of the calibration curves of the analyzed compounds was 0.9922–0.9986, and the limits of detection and limits of quantification were in the range of 0.002–2 and 0.0055–5.5 ng ml−1, respectively. The detected limit of quantification for testosterone (i.e. 50 pg ml−1) is twofold lower with respect to its threshold admitted in geldings plasma (100 pg ml−1 free testosterone). The high sensitivity and the quantitative aspect of the method permitted to detect most of the steroids in equine serum. Once validated, the method was used to quantify 17 steroid hormones in mare, stallion and gelding serum samples. The main steroids detected were corticosterone (range 37.25–51.26 ng ml−1) and cortisol (range 32.57–52.24 ng ml−1), followed by 17‐OH‐pregnenolone, dihydrotestosterone and pregnenolone. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

11.
Dapoxetine is used for the treatment of premature ejaculation. The present study developed an HPLC–MS/MS method to determine the levels of dapoxetine in human plasma processed using simple protein precipitation. Dapoxetine-d7 was selected as the internal standard. The established method was performed using a mass spectrometer equipped with an electrospray ionization source in multiple positive ion reactions to monitor the mode using the precursor-to-product ion transitions of m/z 306.2–157.2 and m/z 313.2–164.2 for dapoxetine-d7 and dapoxetine, respectively. The method was evaluated based on its selectivity, linearity, limit of quantification, precision, accuracy, matrix effects, dilution integrity, stability, and extraction recovery. As a result of the model used in the present study, the validated linear ranges of dapoxetine were determined to be 2.00~1000 ng/mL in plasma, and the selectivity, precision, accuracy, dilution integrity, stability, and extraction recovery met the accepted standard. No matrix interference was observed. The method was successfully validated and applied to pharmacokinetic studies in healthy Chinese volunteers during the fasting and postprandial periods, respectively.  相似文献   

12.
Pollutants such as human pharmaceuticals and synthetic hormones that are not covered by environmental legislation have increasingly become important emerging aquatic contaminants. This paper reports the development of a sensitive and selective multi-residue method for simultaneous determination and quantification of 23 pharmaceuticals and synthetic hormones from different therapeutic classes in water samples. Target pharmaceuticals include anti-diabetic, antihypertensive, hypolipidemic agents, β2-adrenergic receptor agonist, antihistamine, analgesic and sex hormones. The developed method is based on solid phase extraction (SPE) followed by instrumental analysis using liquid chromatography-electrospray ionization-tandem mass spectrometry (LC–ESI-MS/MS) with 30 min total run time. River water samples (150 mL) and (sewage treatment plant) STP effluents (100 mL) adjusted to pH 2, were loaded into MCX (3 cm3, 60 mg) cartridge and eluted with four different reagents for maximum recovery. Quantification was achieved by using eight isotopically labeled internal standards (I.S.) that effectively correct for losses during sample preparation and matrix effects during LC–ESI-MS/MS analysis. Good recoveries higher than 70% were obtained for most of target analytes in all matrices. Method detection limit (MDL) ranged from 0.2 to 281 ng/L. The developed method was applied to determine the levels of target analytes in various samples, including river water and STP effluents. Among the tested emerging pollutants, chlorothiazide was found at the highest level, with concentrations reaching up to 865 ng/L in STP effluent, and 182 ng/L in river water.  相似文献   

13.
Liquid chromatography, coupled with tandem mass spectrometry, presents a powerful tool for the quantification of the sex steroid hormones 17‐β estradiol, progesterone and testosterone from biological matrices. The importance of accurate quantification with these hormones, even at endogenous levels, has evolved with our understanding of the role these regulators play in human development, fertility and disease risk and manifestation. Routine monitoring of these analytes can be accomplished by immunoassay techniques, which face limitations on specificity and sensitivity, or using gas chromatography–mass spectrometry. LC–MS/MS is growing in capability and acceptance for clinically relevant quantification of sex steroid hormones in biological matrices and is able to overcome many of the limitations of immunoassays. Analyte specificity has improved through the use of novel derivatizing agents, and sensitivity has been refined through the use of high‐resolution chromatography and mass spectrometric technology. This review highlights these innovations, among others, in LC–MS/MS steroid hormone analysis captured in the literature over the last decade.  相似文献   

14.
Deoxynivalenol (DON) is one of the most common mycotoxins in grains, causing gastrointestinal inflammation, neurotoxicity, hepatotoxicity and embryotoxicity, even at a low quantity. In this study, a facile electrochemical aptasensor was established for the rapid and sensitive determination of DON based on a multifunctional N-doped Cu-metallic organic framework (N–Cu–MOF) nanomaterial. The N–Cu–MOF, with a large specific surface area and good electrical conductivity, served not only as an optimal electrical signal probe but also as an effective supporting substrate for stabilizing aptamers through the interactions of amino (-NH2) and copper. Under the optimal conditions, the proposed sensor provided a wide linear concentration range of 0.02–20 ng mL−1 (R2 = 0.994), showing high sensitivity, with a lower detection limit of 0.008 ng mL−1, and good selectivity. The sensor’s effectiveness was also verified in real spiked wheat samples with satisfactory recoveries of 95.6–105.9%. The current work provides a flexible approach for the rapid and sensitive analysis of highly toxic DON in food samples and may also be easily extended to detect other hazardous substances with alternative target-recognition aptamers.  相似文献   

15.
Salvia miltiorrhiza Bunge (SM) has been extensively used in Alzheimer’s disease treatment, the permeability through the blood-brain barrier (BBB) determining its efficacy. However, the transport mechanism of SM components across the BBB remains to be clarified. A simple, precise, and sensitive method using LC-MS/MS was developed for simultaneous quantification of tanshinone I (TS I), dihydrotanshinone I (DTS I), tanshinone IIA (TS IIA), cryptotanshinone (CTS), protocatechuic aldehyde (PAL), protocatechuic acid (PCTA), and caffeic acid (CFA) in transport samples. The analytes were separated on a C18 column by gradient elution. Multiple reaction monitoring mode via electrospray ionization source was used to quantify the analytes in positive mode for TS I, DTS I, TS IIA, CTS, and negative mode for PAL, PCTA, and CFA. The linearity ranges were 0.1–8 ng/mL for TS I and DTS I, 0.2–8 ng/mL for TS IIA, 1–80 ng/mL for CTS, 20–800 ng/mL for PAL and CFA, and 10–4000 ng/mL for PCTA. The developed method was accurate and precise for the compounds. The relative matrix effect was less than 15%, and the analytes were stable for analysis. The established method was successfully applied for transport experiments on a BBB cell model to evaluate the apparent permeability of the seven components.  相似文献   

16.
The aquaculture industry has become a sustainable source of food for humans. Remaining challenges include disease issues and ethical concerns for the discomfort and stress of farmed fish. There is a need for reliable biomarkers to monitor welfare in fish, and the stress hormone cortisol has been suggested as a good candidate. This study presents a novel method for measurement of cortisol in fish feces based on enzymatic hydrolysis, liquid–liquid extraction, derivatization, and finally instrumental analysis by liquid chromatography coupled with tandem mass spectrometry. Hydrolysis and extraction conditions were optimized. Cortisol appeared to be mostly conjugated to sulfate and less conjugated to glucuronic acid in the studied samples of feces from farmed Atlantic salmon. The method was suitable for quantification of cortisol after enzymatic deconjugation by either combined glucuronidase and sulfatase activity, or by glucuronidase activity alone. The limit of detection was 0.15 ng/g, the limit of quantification was 0.34 ng/g, and the method was linear (R2 > 0.997) up to 380 ng/g, for measurement of cortisol in wet feces. Method repeatability and intermediate precision were acceptable, both with a coefficient of variation (CV) of 11%. Stress level was high in fish released into seawater, and significantly reduced after eight days.  相似文献   

17.
The use of highly toxic rocket fuel based on 1,1-dimethylhydrazine (UDMH) in many types of carrier rockets poses a threat to environment and human health associated with an ingress of UDMH into wastewater and natural reservoirs and its transformation with the formation of numerous toxic nitrogen-containing products. Their GC-MS quantification in aqueous samples requires matrix change and is challenging due to high polarity of analytes. To overcome this problem, accelerated water sample preparation (AWASP) based on the complete removal of water with anhydrous sodium sulfate and transferring analytes into dichloromethane was used. Twenty-nine UDMH transformation products including both the acyclic and heterocyclic compounds of various classes were chosen as target analytes. AWASP ensured attaining near quantitative extraction of 23 compounds with sample preparation procedure duration of no more than 5 min. Combination of AWASP with gas chromatography–mass spectrometry and using pyridine-d5 as an internal standard allowed for developing the rapid, simple, and low-cost method for simultaneous quantification of UDMH transformation products with detection limits of 1–5 μg L−1 and linear concentration range covering 4 orders of magnitude. The method has been validated and successfully tested in the analysis of aqueous solutions of rocket fuel subjected to oxidation with atmospheric oxygen, as well as pyrolytic gasification in supercritical water modelling wastewater from carrier rockets launch sites.  相似文献   

18.
Compound Anoectochilus roxburghii (Wall.) Lindl. (A. roxburghii) oral liquid (CAROL) is a hospital preparation of A. roxburghii and Ganoderma lucidum (G. lucidum), which have hepatoprotective effects. Eight active components (five nucleosides/nucleobases and three triterpenoid acids) in CAROL, A. roxburghii, and G. lucidum were simultaneously detected by high-performance liquid chromatography–tandem mass spectrometry (LC–MS/MS). The multiple reaction monitoring (MRM) mode was applied for the detection of analytes. These eight compounds were separated well within 12 min and quantified using the internal standard working curve method. The method showed good linearity (R2 > 0.9935) and high sensitivity (limit of detection = 0.29 ng/mL). The analyte recovery ranged from 85.07% to 97.50% (relative standard deviation < 3.31%). The content of the target analytes in four batches of CAROL, and the raw materials of G. lucidum and A. roxburghii from the five regions was determined using this method. The contents of guanosine and ganoderic acid A in four batches of oral liquid were high and stabilized and could be recommended as quality markers (Q-marker) for CAROL. Simultaneous qualitative and quantitative analysis of nucleosides and triterpenoid acids in CAROL, A. roxburghii, and G. lucidum by LC–MS/MS based on the MRM model was reported for the first time. The proposed method provides a sensitive, rapid, and reliable approach for the quality control of Chinese medicinal products.  相似文献   

19.
Eight novel pyridyl–oxazole carboxamides were evaluated against fungi and displayed good fungicidal activities against Botrytis cinereal and Rhizoctonia solani. Preliminary bioassay results indicated that at 100 mg/L, compounds 6a–6e, 6g and 6h exhibited 100% fungicidal activities against Botrytis cinerea, and the compound 6b to Rhizoctonia solani at 100%. Then, the zebrafish embryo acute toxicity test was performed to assess the toxicity of 6b and 6c. A series of malformations appeared, when the zebrafish embryos were exposed to 6b and 6c, such as delayed yolk sac resorption, significant shortening of body length, pericardial edema, bending spine, lack of melanin, heart hemorrhage, head hemorrhage, delayed swim sac development, yolk malformation and head malformation. In addition, the acute toxicity of 6b to zebrafish embryo is 4.878 mg/L, and 6c is 6.257 mg/L.  相似文献   

20.
This method describes the simultaneous separation, identification, quantification and confirmation of betamethasone (BTM) and dexamethasone (DXM) in equine plasma by liquid chromatography (LC) integrated with multidimensional tandem mass spectrometry. Analytes were directly extracted from equine plasma by methyl tert-butyl ether (MTBE). The residues were reconstituted with sample solvent. LC separation of the analytes was performed on a Hypercarb column using acetonitrile/water/formic acid (95:5:0.5, v/v/v) as the mobile phase. Sample screening, quantification and confirmation were performed in multiple reaction monitoring (MRM) mode. The method was linear over the concentration range of 0.1-75 ng/mL for both analytes. Limit of detection (LOD) was 50 pg/mL and that of quantification (LOQ) was 100 pg/mL for both analytes. The limit of confirmation (LOC) for the presence of BTM or DXM by MRM was 0.5 ng/mL. The intra-and inter-day precisions expressed as coefficient of variation (CV) for quantification of DXM and BTM from 0.1 to 50 ng/mL were less than 7% and the accuracy was in the range of 97-105%. This method is capable of distinguishing BTM from DXM when both analytes are simultaneously present in equine plasma. Measurement uncertainty for both analytes was estimated at less than 16%. The method is rapid, specific, selective, sensitive, simple and reliable. The importance of this method is its usefulness in directly identifying and differentiating BTM from DXM without derivatization.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号