首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 390 毫秒
1.
A high-performance liquid chromatographic method has been developed for the determination of a new cephalosporin antibiotic in plasma, urine and saliva (mixed saliva) using normal-phase technique and an NH2 bonded-phase column. The eluent mixture was a combination of acetonitrile and an aqueous solution of ammonium carbonate. The rapid method involved precipitation of protein from fluids by means of acetonitrile followed by automatic injection of the supernatant. The detection limit was 0.4 micrograms/ml for plasma, 3 micrograms/ml for urine and 0.03 micrograms/ml for saliva using UV detection.  相似文献   

2.
A sensitive, selective and easy to use high-performance liquid chromatographic method for the determination of cicletanide, a new diuretic, in plasma, red blood cells, urine and saliva is described. After extraction of cicletanide together with an internal standard with diethyl ether, or diethyl ether-n-hexane (20:80) for urine, the sample extracts are chromatographed with water-methanol-acetic acid (50:50:0.3) as eluent on to a Nucleosil C18 column. Both compounds are detected by their ultraviolet absorption at 280 nm. The calibration graph was linear between 0.2 and 20 micrograms/ml for plasma and between 0.2 and 5 micrograms/ml for the other biological fluids. The sensitivity limit was 20 ng/ml for plasma, red blood cells and saliva and 30 ng/ml for urine. The coefficients of variation of the between-day assays did not exceed 4.6% in plasma, 8.3% in red blood cells, 7.8% in urine and 4.2% in saliva for the lowest concentrations studied. The application of the method to a pharmacokinetic study of cicletanide after a single oral therapeutic dose in humans is reported.  相似文献   

3.
A sensitive and selective high-performance liquid chromatography method has been developed for the determination of the new monocyclic beta-lactam antibiotic carumonam in plasma and urine. The method for plasma involves protein precipitation with acetonitrile and removal of lipids with dichloromethane; urine is diluted with buffer. Separation and quantification are achieved using a mobile phase based on either ion-suppression or ion-pair chromatography on a reversed-phase column with UV detection. The limit of determination is 0.5 micrograms/ml plasma, using a 0.5-ml specimen, and 25 micrograms/ml urine, using a 50-microliter specimen. The inter-assay reproducibility is generally better than 4% when an internal standard is used. Since beta-lactam antibiotics may degrade on storage, close attention must be paid to the stability of these drugs in biological fluids; novel measures to prevent degradation on storage are described. The assay has been successfully applied to the analysis of several thousand samples from pharmacokinetic studies, including a study involving patients with impaired renal function.  相似文献   

4.
A high-performance liquid chromatographic (HPLC) method for the determination of sulbactam in human and rat plasma and urine has been developed. Sulbactam was reacted with 1,2,4-triazole to yield a product having an ultraviolet absorption maximum at 326 nm. The product was separated using reversed-phase HPLC from the regular components of plasma and urine with an ion-pair buffer at 50 degrees C and detected at the ultraviolet maximum. The limits of accurate determination were 0.2 and 1.0 micrograms/ml in plasma and urine, respectively. The coefficients of variation of inter- and intra-assays in human plasma spiked at 4.0 micrograms/ml (n = 5) were 1.02 and 3.05%, respectively. Coexisting cefoperazone, penicillins, or the alkaline degradation product(s) of sulbactam did not interfere in the sulbactam assay. The pharmacokinetic behaviour of sulbactam and cefoperazone coadministered to rats was estimated by moment analysis.  相似文献   

5.
A liquid chromatographic method using a solid-phase extraction procedure for the quantification of sotalol in plasma and urine is described. Sotalol is eluted from an extraction column with ethyl acetate-acetonitrile (1:2) and, after separation by reversed-phase high-performance liquid chromatography on a mu Bondapak C18 column, is quantified by fluorescence detection at excitation and emission wavelengths of 240 and 310 nm, respectively. The method has been demonstrated to be linear over the concentration ranges 10-6000 ng/ml in plasma and 0.5-100 micrograms/ml in urine. Mean inter-assay accuracy of the method for plasma ranged from 93 to 100% and for urine from 102 to 114%; precision ranged from 0.5 to 1.6% for plasma over a concentration range of 200-4000 ng/ml and for urine from 0.7 to 2.0% at concentrations of 2-50 micrograms/ml. Mass spectrometry confirmed the presence of sotalol in isolated chromatographic fractions of plasma and urine extracts from subjects given sotalol orally.  相似文献   

6.
A sensitive reversed-phase high-performance liquid chromatographic (HPLC) technique with ultraviolet detection has been developed to determine the concentration of BRB-I-28 (I), a novel antiarrhythmic agent, in dog plasma and urine. The mobile phase was acetonitrile-methanol-37.5 mM phosphate buffer, pH 6.8-triethylamine (50:50:75:0.1, v/v). The compound was extracted from dog plasma and urine with chloroform after alkalinization with sodium hydroxide. The extraction recovery was 83% from plasma and 84% from urine. Good linearity (r > 0.996) was observed throughout the ranges 0.1-12.0 micrograms/ml (plasma) and 0.1-8.0 micrograms/ml (urine). Intra- and inter-assay variabilities were less than 4%. The lower limit of quantitation was 0.08 microgram/ml in either plasma or urine. HPLC analysis of plasma and urine samples from a dog treated with I has demonstrated that the method was accurate and reproducible.  相似文献   

7.
A gradient elution high-performance liquid chromatographic method is described for the analysis of the beta-lactamase inhibitor tazobactam (YTR-830H) and a semi-synthetic parenteral penicillin, piperacillin, in human plasma, serum, bile and urine. The assay for plasma, serum and bile involves deproteinization with acetonitrile and the removal of lipids with dichloromethane; urine is diluted with buffer. Separation and quantitation are achieved using a mobile phase based on ion-suppression chromatography on a C18 reversed-phase column with ultraviolet detection at 220 nm. The limit of quantitation for both compounds is 1.0 microgram/ml in plasma, serum and bile using a 0.2-ml sample and 50.0 micrograms/ml in urine using a 0.1-ml sample. The method has been validated by preparing and analyzing a series of fortified samples (range 1.0-200 micrograms/ml for each compound in plasma, serum and bile and 50.0-10,000 micrograms/ml for each compound in urine). Excellent linearity, accuracy, precision and recovery were obtained. The method was not interfered with by other endogenous components, nor by other commonly administered antibiotics such as amoxicillin, mezlocillin, cefometazole and cefotaxime. The assay has been successfully applied to the analysis of samples from pharmacokinetic studies in man and animals.  相似文献   

8.
A sensitive and reproducible high-performance liquid chromatographic method was developed to assay ampherotericin B in plasma, blood, urine and various tissue samples. Amphotericin B was isolated from each sample matrix by solid-phase extraction (Bond-Elut). The eluate from Bond-Elut containing amphotericin B was injected onto a reversed-phase C18 column (Waters, mu Bondpak, 10 microns, 300 mm x 3.9 mm I.D.) with a mobile phase of 45% acetonitrile in 2.5 mM Na2EDTA at 1 ml/min. Detection of amphotericin B was by ultraviolet absorption at 382 nm. Blood and tissues were homogenized and extracted with methanol prior to Bond-Elut extraction. The extraction efficiencies of amphotericin B from plasma, blood and tissues were approximately 90, 70 and 75%, respectively. The sensitivity of the assay was less than or equal to 5 ng/ml for plasma, less than or equal to 25 ng/ml for blood, 2.5 ng/ml for urine and 50 ng/g for tissues. The linearity of the assay method was up to 2.5 micrograms/ml for plasma, 5 micrograms/ml for blood, 500 ng/ml for urine and 500 micrograms/g for tissues. The assay was reproducible with an intra-day coefficient of variation (C.V., n = 3) of less than 5% in general for plasma, blood and tissues. The inter-day C.V. of the assay was less than 5% for plasma (n = 5), less than 10% for blood (n = 4) and less than 5% for tissues (n = 3). The overall variability in the urine assay was generally less than 10%. This method has demonstrated significant improvement in the sensitivity and reproducibility in assaying amphotericin B in plasma and especially in blood, urine and tissues. We have employed this assay to compare the pharmacokinetic and tissue distribution profiles of amphotericin B in rats and dogs following administration of Fungizone and ABCD (amphotericin B-cholesteryl sulfate colloidal dispersion), a lipid-based dosage form. In addition, the assay method for plasma and urine samples can also be applied to pharmacokinetics studies of amphotericin B in man.  相似文献   

9.
Determination of malotilate and its metabolites in plasma and urine   总被引:1,自引:0,他引:1  
A method for the determination of malotilate (I), the corresponding monocarboxylic acid (II) and its decarboxylated product (III) in plasma is described. Plasma was extracted with chloroform spiked with internal standard. The residue, dissolved in methanol, was chromatographed on a reversed-phase column with a mobile phase of 60% acetonitrile and 1% acetic acid in water. The sensitivity limit for I, II and III was 50, 25 and 100 ng/ml of plasma, respectively. Compound I in the same plasma extract was also analysed by gas chromatography--electron-impact mass spectrometry. The base peaks m/z 160 for I and m/z 162 for internal standard (IV) were monitored; the sensitivity limit for I was 2.5 ng/ml of plasma. The determination of the metabolites of I, II and its conjugate (V), and isopropyl-hydrogen malonate (VI) in urine by high-performance liquid chromatography is also described. The limit of quantification for VI was 2.0 micrograms/ml, and the overall coefficient of variation of VI was 4.7%. The limit of quantification for II in urine was 0.5 micrograms/ml and that for V was 1.0 micrograms/ml as total II (II + V). The overall precision of the method was satisfactory. The method was used to determine plasma and urine concentrations in four dogs orally dosed with 100, 200 or 400 mg of malotilate.  相似文献   

10.
A reversed-phase isocratic high-performance liquid chromatographic method for the determination of total teicoplanin in plasma is reported. The method developed uses a bracketing injection technique in conjunction with large injection volumes on a 1 mm diameter column to form a limited injection-generated gradient. The chromatography yields adequate resolution among all the major components for individual quantitation and also allows quantitation of total teicoplanin in plasma using ultraviolet detection. Pretreatment is by solid-phase extraction which uses C8 Bond Elut cartridges and gives effective clean up from endogenous materials. The method offers a faster and simplified means to determine total teicoplanin in plasma than those previously reported, and has a detection limit of 50 ng/ml.  相似文献   

11.
An isocratic reversed-phase ion-pair liquid chromatographic method for the determination of tianeptine and its two main metabolites in plasma, urine and tissues, using an internal standard, is reported. The influence of two stationary phases on the retention of the drugs was studied. The drugs were extracted as ion pairs, using a heptane-octanol-tetraheptylammonium bromide mixture (98:2:0.5, v/v/w) as extraction solvent. This extraction procedure yielded plasma drug recoveries of greater than 60% and allowed UV detection at 220 nm without interference from endogenous components of plasma, urine or tissues. Linear standard curves up to 1.00 micrograms/ml and drug determination down to 0.01 microgram/ml were observed. This method has been successfully applied to the analysis of human plasma and urine samples and of encephales from tianeptine-dosed rats.  相似文献   

12.
In oncology, particularly in pediatric malignancies, high doses (5-10 g/m2) of the oxazaphosphorine ifosfamide play an important role in the treatment of sarcomas. Pharmacokinetic data of ifosfamide and its metabolites in these cases are scanty. Considering the special demands of the determination of ifosfamide in plasma of young children, a very sensitive capillary gas chromatographic method, requiring only 50 microliters of plasma, has been developed. This bioanalysis of ifosfamide shows good linearity and accuracy in the concentration range 10 ng to 100 micrograms per ml of plasma and 25 ng to 1 mg per ml of urine. The absolute limits of detection in plasma and urine are 2 ng/ml and 5 ng/ml, respectively. The stability of various solutions of ifosfamide and trofosfamide was tested and proved to be satisfactory, except for ifosfamide in plasma and urine kept in the refrigerator. The validity of the method for pharmacokinetic purposes is shown in the case of one patient.  相似文献   

13.
A sensitive, selective, and rapid high-performance liquid chromatographic procedure was developed for the determination of isoxicam in human plasma and urine. Acidified plasma or urine were extracted with toluene. Portions of the organic extract were evaporated to dryness, the residue dissolved in tetrahydrofuran (plasma) or acetonitrile (urine) and chromatographed on a mu Bondapak C18 column preceded by a 4-5 cm X 2 mm I.D. column packed with Corasil C18. Quantitation was obtained by UV spectrometry at 320 nm. Linearity in plasma ranged from 0.2 to 10 micrograms/ml. Recoveries from plasma samples seeded with 1.8, 4 and 8 micrograms/ml isoxicam were 1.86 +/- 0.077, 4.10 +/- 0.107 and 8.43 +/- 0.154 micrograms/ml with relative standard deviations of 3.3%, 2.5% and 5.4%, respectively. The linearity in urine ranged from 0.125 to 2 micrograms/ml. The precision of the method was 3.3-9.0% relative standard deviation over the linear range.  相似文献   

14.
A simple high-performance liquid chromatographic method is presented for the determination of trace amounts of sulphadimidine (SDD), its hydroxylated metabolites and N4-acetyl-SDD in blood plasma, urine, hepatocyte culture media and microsomal incubations. The synthesis of 5-hydroxy-SDD and an improved method for the isolation of 4-methylhydroxy-SDD from urine are described and their respective specific absorption coefficients at 265 nm are calculated by on-line radiochemical and ultraviolet detection. The limit of detection of the analytical method is 0.05 micrograms/ml for SDD and its hydroxy metabolites and 0.2 micrograms/ml for N4-acetyl-SDD. Linear calibration graphs for SDD and its metabolites were constructed from 0.2 to 50 micrograms/ml. The method has been applied to biotransformation studies in vivo and in vitro.  相似文献   

15.
A quantitative method for the simultaneous high-performance liquid chromatographic (HPLC) resolution and determination of the enantiomers of 5-dimethylsulphamoyl-6,7-dichloro-2,3-dihydrobenzofuran-2-carboxyl ic acid, a new diuretic, and its N-monodemethylated metabolite in monkey plasma and urine is described. The method includes diethyl ether extraction of the samples and S-(-)-alpha-methylbenzylamide derivatization of the extract, followed by reversed-phase solid-phase extraction and injection of the resulting diastereoisomers onto a reversed-phase HPLC column. Baseline separation was obtained. The assay showed linearity over the range 0.1-50 micrograms/ml of plasma and 0.25-500 microliters of urine, with a lower limit of detection of ca. 0.01 micrograms/ml for each of the enantiomers. The method is adequate for pharmacokinetic and enantioselective disposition studies of both the diuretic and its metabolite.  相似文献   

16.
The metabolic oxidation of one of the chloroethyl groups of the antitumour drug ifosfamide leads to the formation of the inactive metabolites 2- and 3-dechloroethylifosfamide together with the neurotoxic metabolite chloroacetaldehyde. A very sensitive capillary gas chromatographic method, requiring only 50 microliters of plasma or urine, has been developed to measure the amounts of the drug and the two inactive metabolites in a single run. Calibration curves were linear (r > 0.999) in the concentration ranges from 50 ng/ml to 100 micrograms/ml in plasma and from 100 ng/ml to 1 mg/ml in urine.  相似文献   

17.
A high-performance liquid chromatographic (HPLC) method is reported for the determination of a new carbacephem antibiotic, loracarbef, a hydroxylated analogue, and two cephalosporins, cefaclor and cephalexin, in plasma, serum, and urine. The antibiotics are extracted from plasma by means of C18 solid-phase cartridges. Urine samples are diluted with water and directly injected on the HPLC system. The HPLC system utilizes a Supelcosil LC-18-DB (250 mm x 4.6 mm I.D.) reversed-phase column and ultraviolet detection at 265 nm. The limit of quantitation is 0.5 micrograms/ml for each compound. Excellent correlation of plasma concentrations is shown between results determined by HPLC and those obtained by microbiological agar-well diffusion assays. Stability studies of loracarbef in human plasma show the antibiotic to be stable for at least 24 h at room temperature and for at least twelve months at -20 degrees C.  相似文献   

18.
An isocratic reversed-phase high-performance liquid chromatographic (HPLC) method for the determination of methylmercaptopurine riboside (MMPR) in human plasma and urine is reported. Plasma samples were prepared for analysis by addition of internal standard (6-dimethylaminopurine 9-riboside) followed by extraction using disposable C18 cartridges. Urine samples were filtered through a 0.22-micron membrane prior to HPLC separation. The column effluent was monitored at 289 nm and quantitation performed using peak heights. The linear range for MMPR determination was from 10 to 500 ng/ml in plasma and from 0.25 to 50 micrograms/ml in urine. The reported method is convenient, sensitive, and reproducible, illustrating its usefulness for application in pharmacokinetic studies.  相似文献   

19.
A high-performance liquid chromatographic assay for determination of cefonicid concentrations in human plasma and urine samples has been developed using cefazolin as an internal standard. For the analysis of plasma samples two calibration curves were utilized covering the cefonicid concentration ranges of 0.05-1.0 microgram/ml and 1.0-50.0 micrograms/ml, respectively. Coefficients of variation of 7.4% or less were obtained for cefonicid concentrations of 0.05-50.0 micrograms/ml. Mean bias was +6.0% at 0.05 micrograms/ml cefonicid and between -2.1% and +1.6% for 1.0-50.0 micrograms/ml cefonicid. Plasma samples containing 30 ng/ml cefonicid could be well distinguished from blank plasma samples. Urine samples were analysed by using a calibration curve for cefonicid concentrations between 1.0 and 50.0 micrograms/ml. ranged from 8.6% at a cefonicid concentration of 1.0 microgram/ml to 0.5% at 50.0 micrograms/ml with a mean bias between -3.0% and +0.3%.  相似文献   

20.
A method has been developed for the simultaneous determination of Tranilast, N-(3',4'-dimethoxycinnamoyl)anthranilic acid (N-5'), and metabolites in plasma and urine from humans, dogs and rodents administered N-5'. Total N-5' and metabolite N-3 conjugates were determined in human urine. Detection limits in plasma were 0.2 micrograms/ml for metabolite N-3-S and N-5' and 0.1 micrograms/ml for metabolites N-3 and N-4. In urine, detection limits were 2 micrograms/ml for metabolite N-3-S and N-5' and 1 micrograms/ml for metabolites N-3 and N-4. Metabolite N-4 was not identified in any sample assayed.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号