首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 109 毫秒
1.
The retention of organic selenium compounds on a porous graphitic carbon stationary phase was investigated. Different acids were studied as mobile phases to elute selenocystamine, selenoethionine, selenomethionine and selenocystine. Detection was achieved using inductively coupled plasma-atomic emission spectrometry to provide selenium-specific and sensitive detection. The separation of the four species was carried out using methanoic acid. An important on-column preconcentration was obtained when solutes were injected in nitric acid or trifluoroacetic acid (TFA) media. The large injection volume employed (2,500 µL) allowed us to reach low relative detection limits (2–6 µg/L). The method, employing TFA as injection solvent and methanoic acid as the eluent was found to be robust with respect to different matrices spiked with selenocompounds.  相似文献   

2.
A simple capillary zone electrophoresis procedure was developed for the separation of arsenic species (AsO(2)(2-), AsO(4)(2-), and dimethylarsinic acid, DMA). Both counter-electroosmotic and co-electroosmotic (EOF) modes were investigated for the separation of arsenic species with direct UV detection at 185 nm using 20 mmol L(-1) sodium phosphate as the electrolyte. The separation selectivity mainly depends on the separation modes and electrolyte pH. Inorganic anions (Cl(-), NO(2)(-), NO(3)(-) and SO(4)(2-)) presented in real samples did not interfere with arsenic speciation in either separation mode. To improve the detection limits, sample-stacking techniques, including large-volume sample stacking (LVSS) and field-amplified sample injection (FASI), were investigated for the preconcentration of As species in co-CZE mode. Less than 1 micromol L(-1) of detection limits for As species were achieved using FASI. The proposed method was demonstrated for the separation and detection of As species in water.  相似文献   

3.
Yin XB 《Electrophoresis》2004,25(12):1837-1842
An on-line preconcentration method was developed for capillary electrophoresis (CE) with hydride generation-atomic fluorescence spectrometric (HG-AFS) detection of arsenite, arsenate, dimethylarsenic acid, and monomethylarsenic acid. These arsenic species were negatively charged in the sample solution with high pH. When the potential was applied to the electrophoretic capillary, the negatively charged analyte ions moved faster and stacked at the boundary of sample and CE buffer with low pH. So, high sample pH in combination with low buffer pH allowed the injection of large sample volumes (approximately 1100 nL). Comparison of the preconcentration of analyte solution, prepared with doubly deionized water and that prepared with lake or river water, indicated that preconcentration was independent on the original matrix. With injection of approximately 1100 nL sample, an enrichment factor of 37-50-fold was achieved for the four species. Detection limits for the four arsenic species ranged from 5.0 to 9.3 microg.L(-1). Precisions (RSDs, n = 5) were in the range of 4.9-6.7% for migration time, 4.7-11% for peak area, and 4.3-7.1% for peak height, respectively. The recoveries of the four species in locally collected water solution spiked with 0.1 microg.mL(-1) (as As) ranged from 83 to 109%.  相似文献   

4.
Two methods for the simultaneous determination of selenite and two organoselenium compounds, dimethylselenide (DMSe) and dimethyldiselenide (DMDSe), are proposed. Both methods involve sample preconcentration by solid-phase microextraction (SPME) and capillary gas chromatography coupled to atomic emission detection (GC-AED). The main difference between the methods is the derivatizing agent used to complex the inorganic species: sodium tetraethylborate and 4,5-dichloro-1,2-phenylenediamine. The parameters affecting the derivatization and preconcentration steps, chromatographic separation as well as detection of the compounds were optimized. Direct immersion (DI) mode and a relatively long extraction time were selected for the method involving the formation of the piazselenol complex, better sensitivity being achieved for the three analytes under study. In this case, detection limits ranged between 3 and 25 ng L(-1), depending on the compound. Headspace mode (HS) and extraction times of 20 min were selected for the method involving tetraalkylborate, and detection limits of between 7.3 and 55 ng L(-1) were obtained. DMSe and Se(IV) were found in several of the water samples analyzed at concentrations of 0.07-1.0 ng mL(-1).  相似文献   

5.
HPLC-ICP-MS或HPLC-FAAS法分离测定硒化合物(英文)   总被引:5,自引:0,他引:5  
李方实 《色谱》1999,17(3):240-244
 提出了一种用高效液相色谱(HPLC)分离和用电感偶合等离子体质谱仪(ICP-MS)或火焰原子吸收光谱仪(FAAS)作元素专一检测器在线测定硒的化学形态的方法。在优化的HPLC条件下,用ESAⅢ阴离子色谱柱(250mm×4.6mm),以柠檬酸铵为流动相(5.5mmol/L,pH5.5,流速1.5mL/min),进样量100μL,分离和测定三甲基硒离子、硒代蛋氨酸、亚硒酸和硒酸盐只需8min。HPLC-FAAS在线分析4种硒化合物的检测限为p(Se)=1mg/L。  相似文献   

6.
An on-line dysprosium preconcentration and determination system based on the hyphenation of cloud point extraction (CPE) to flow injection analysis (FIA) associated with ICP-OES was studied. For the preconcentration of dysprosium, a Dy(III)-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol complex was formed on-line at pH 9.22 in the presence of nonionic micelles of PONPE-7.5. The micellar system containing the complex was thermostated at 30 degrees C in order to promote phase separation, and the surfactant-rich phase was retained in a microcolumn packed with cotton at pH 9.2. The surfactant-rich phase was eluted with 4 mol L(-1) nitric acid at a flow rate of 1.5 mL min(-1), directly in the nebulizer of the plasma. An enhancement factor of 50 was obtained for the preconcentration of 50 mL of sample solution. The detection limit value for the preconcentration of 50 mL of aqueous solution of Dy was 0.03 microg L(-1). The precision for 10 replicate determinations at the 2.0 microg L(-1)Dy level was 2.2% relative standard deviation (RSD), calculated from the peak heights obtained. The calibration graph using the preconcentration system for dysprosium was linear with a correlation coefficient of 0.9994 at levels near the detection limits up to at least 100 microg L(-1). The method was successfully applied to the determination of dysprosium in urine.  相似文献   

7.
This paper describes a novel application of tetrabutylammonium hydroxide-modified activated carbon (AC-TBAH) to the speciation of ultra-trace Se(IV) and Se(VI) using LC-ICP-DRC-MS. The anion exchange functionality was immobilized onto the AC surface enables selective preconcentration of inorganic Se anions in a wide range of working pHs. Simultaneous retention and elution of both analytes, followed by subsequent analysis with LC-ICP-DRC-MS, allows to accomplish speciation analysis in natural samples without complicated redox pre-treatment. The laboratory-made column of immobilized AC (0.4 g of sorbent packed in a 6 mL syringe barrel) has achieved analyte enrichment factors of 76 and 93, respectively, for Se(IV) and Se(VI), thus proving its superior preconcentration efficiency and selectivity over common AC. The considerable enhancement in sensitivity achieved by using the preconcentration column has improved the method's detection limits to 1.9-2.2 ng L(-1), which is a 100-fold improvement compared with direct injection. The analyte recoveries from heavily polluted river matrix were between 95.3 and 107.7% with less than 5.0% RSD. The robustness of the preconcentration and speciation method was validated by analysis of natural waters collected from rivers and reservoirs in Hong Kong. The modified AC material is hence presented as a low-cost yet robust substitute for conventional anion exchange resins for routine applications.  相似文献   

8.
Lu CY  Yan XP 《Electrophoresis》2005,26(1):155-160
A new method for speciation analysis of two inorganic selenium species was developed by on-line coupling of capillary electrophoresis (CE) with hydride generation-atomic fluorescence spectrometry (HG-AFS) and on-line conversion of Se(VI) to Se(IV). Baseline separation of Se(VI) and Se(IV) was achieved by CE in a 50 cm x 75 microm inside diameter (ID) fused-silica capillary at -20 kV using a mixture of 15 mmol.L(-1) NaH2PO4 and 0.5 mmol.L(-1) cetyltrimethylammonium bromide (pH 7.5) as electrolyte buffer. Se(VI) was on-line reduced to Se(IV) by mixing the CE effluent with concentrated HCl. The precision (relative standard deviation, RSD, n=7) ranged from 0.7 to 1.3% for migration time, 6.4 to 3.7% for peak height response, and 5.9 to 6.1% for peak area for the two selenium species at the 500 microg.L(-1) (as Se) level. The detection limits were 33 and 25 microg.L(-1) (as Se) for Se(VI) and Se(IV), respectively. The recoveries of the two selenium species in five locally collected water samples ranged from 88 to 114%. The developed method was applied to speciation analysis of inorganic selenium species in spiked natural water samples.  相似文献   

9.
A novel, fast, and cheap nonchromatographic method for direct speciation of dissolved inorganic and organic selenium species in environmental and biological samples was developed by flow injection (FI) dual-column preconcentration/separation on-line coupled with ICP-MS determination. In the developed technique, the first column packed with nanometer-sized Al(2)O(3) could selectively adsorb the inorganic selenium [Se(IV), Se(VI)], and the retained inorganic selenium could be eluted by 0.2 mol l(-1) NaOH, while the organic Se [selenocystine (SeCys(2)) and selenomethionine (Se-Met)] was not retained. On the other hand, the second column packed with mesoporous TiO(2) chemically modified by dimercaptosuccinic acid (DMSA) could selectively adsorb Se(IV) and SeCys(2) and barely adsorb Se(VI) and Se-Met. When the sample solution was passed through the column 1, separation of inorganic selenium and organic selenium could be achieved first. Then, the effluent from column 1 was successively introduced into the column 2 and the speciation of organic selenium could be attained due to the different adsorption behaviors of Se-Met and SeCys(2) on DMSA modified TiO(2). After that, the eluent from column 1 contained Se(IV), and Se(VI) was adjusted to desired pH and injected into column 2, and the speciation of Se(IV) and Se(VI) could also be realized thanks to their different retention on column 2. The parameters affecting the separation were investigated systematically and the optimal separation conditions were established. The detection limits obtained for Se(IV), Se(VI), Se-Met and SeCys(2) were 45-210 ng l(-1) with precisions of 3.6-9.7%. The proposed method has been successfully applied for the speciation of dissolved inorganic and organic selenium in environmental and biological samples. In order to validate the methodology, the developed method was also applied to the speciation of selenium in certified reference material of SELM-1 yeast, and the determined values were in good agreement with the certified values.  相似文献   

10.
A preconcentration and determination method for humic and fulvic acids at trace levels in natural water samples was developed. Cloud point extraction was successfully employed for the preconcentration of humic acid (HA) and fulvic acid (FA) prior to the determination by using a flow injection (FI) system coupled to a spectrophotometric UV-Vis detector. The quantitative extraction of HA and FA within the pH range 1-12 was obtained by neutralization of the anionic charge on the humic substances with a cationic surfactant, hexadecyltrimethylammonium bromide (CTAB). This generated a hydrophobic species that was subsequently incorporated (solubilized) into the micelles of a non-ionic surfactant polyethylene glycol, tert-octylphenyl ether (Triton X-114). The FI method for HA and FA determination was developed by injection of 100 microl of the extracted surfactant-rich phase using an HPLC pump with spectrophotometric detection at 350 nm. A 50 ml sample solution preconcentration allowed an enrichment factor of 167. The limit of detection (LOD) obtained under the optimal conditions was 5 microg l(-1). The precision for ten replicate determinations at 0.2 mg l(-1) HA was 3.1% relative standard deviation (RSD), calculated from the peak heights. The calibration using the preconcentration system for HA and FA was linear with a correlation coefficient (r2) of 0.9997 at levels near the detection limits up to at least 1 mg l(-1). The method was successfully applied to the determination of HA and FA in natural water samples (river water).  相似文献   

11.
The combined use of solid-phase microextraction (SPME) and different on-line preconcentration strategies for ultrasensitive capillary electrophoresis-ultraviolet (CE-UV) analysis of five pesticides in a single run is investigated. Normal stacking mode (NSM), field-enhanced sample injection (FESI), and stacking with matrix removal (SWMR) are explored to increase the sensitivity of the CE-UV analysis of a selected group of pesticides (cyprodinil, cyromazine, pyrifenox, pirimicarb, and pyrimethanil). It could be observed that reverse polarity-stacking with matrix removal (RP-SWMR) provided the best results in terms of sensitivity (enhancement was up to 272-fold compared with normal injection). The separation buffer consisted of 0.4 mM cetyltrimethylammonium chloride (CTAC), 0.4 M acetic acid at pH 4 containing 5% v / v 2-propanol. This approach was then combined with SPME to determine the pesticides in water, apple, and orange juice. The combination of both preconcentration procedures allowed the determination of these pesticides at concentrations down to 2.5 microg / L in water and 3.1 microg / L in juices (i.e., levels well below the maximum residue limits allowed for these compounds). To our knowledge, this is the first report showing the great possibilities of the combined use of SPME, on-line sample preconcentration, and CE for pesticide analysis.  相似文献   

12.
A non-chromatographic separation and preconcentration method for Se species determination based on the use of an on-line ionic liquid (IL) dispersive microextraction system coupled to electrothermal atomic absorption spectrometry (ETAAS) is proposed. Retention and separation of the IL phase was achieved with a Florisil®-packed microcolumn after dispersive liquid-liquid microextraction (DLLME) with tetradecyl(trihexyl)phosphonium chloride IL (CYPHOS® IL 101). Selenite [Se(IV)] species was selectively separated by forming Se-ammonium pyrrolidine dithiocarbamate (Se-APDC) complex followed by extraction with CYPHOS® IL 101. The methodology was highly selective towards Se(IV), while selenate [Se(VI)] was reduced and then indirectly determined. Several factors influencing the efficiency of the preconcentration technique, such as APDC concentration, sample volume, extractant phase volume, type of eluent, elution flow rate, etc., have been investigated in detail. The limit of detection (LOD) was 15 ng L−1 and the relative standard deviation (RSD) for 10 replicates at 0.5 μg L−1 Se concentration was 5.1%, calculated with peak heights. The calibration graph was linear and a correlation coefficient of 0.9993 was achieved. The method was successfully employed for Se speciation studies in garlic extracts and water samples.  相似文献   

13.
Quaternary ammonium functionalised polymeric latex particles were coated onto the wall of a fused-silica capillary or onto a methacrylate monolithic bed synthesised inside the capillary in order to create ion-exchange stationary phases of varying ion-exchange capacity. These capillaries were coupled in-line to a separation capillary and used for the solid-phase extraction (SPE), preconcentration and subsequent separation of organic anions by capillary electrophoresis. A transient isotachophoretic gradient was used for the elution of bound analytes from the SPE phase using two modes of separation. The first comprised a low capacity SPE column combined with a fluoride/octanesulfonate discontinuous electrolyte system in which peak compression occurred at the isotachophoretic gradient front. The compressed anions were separated electrophoretically after elution from the SPE preconcentration phase and resolution was achieved by altering the pH of the electrolyte in which the separation was performed. In the second approach, a latex-coated monolithic SPE preconcentration stationary phase was used in combination with a fluoride/perchlorate electrolyte system, which allowed capillary electrochromatographic separation to occur behind the isotachophoretic gradient front. This method permitted the removal of weakly bound anions from the SPE phase, thereby establishing the possibility of sample clean-up. The effect of the nature of the strong electrolyte forming the isotachophoretic gradient on the separation and also on the preconcentration step was investigated. Capillary electrochromatography of inorganic and organic species performed on the latex-coated monolithic methacrylate column highlighted the presence of mixed-mode interactions resulting from the incomplete coverage of latex particles onto the monolithic surface. Analyte preconcentration prior to separation resulted in compression of the analyte zone by a factor of 300. Improvement in the limit of detection of up to 10400 times could be achieved when performing the preconcentration step and the presented methods had limits of detection (S/N=3) ranging between 1.5 and 12 nM for the organic anions studied.  相似文献   

14.
The separation of three common anabolic steroids (methyltestosterone, methandrostenolone and testosterone) was performed for the first time by capillary EKC. Different charged CD derivatives and bile salts were tested as dispersed phases in order to achieve the separation. A mixture of 10 mmol/L succinylated-beta-CD with 1 mmol/L beta-CD in a 50 mmol/L borate buffer (pH 9) enabled the separation of the three anabolic steroids in less than 9 min. Concentration LODs, obtained for these compounds with low absorption of UV light, were approximately 5 x 10(-5) mol/L. The use of online reverse migrating sample stacking with large-volume injection (the effective length of the capillary) enabled to improve the detection sensitivity. Sensitivity enhancement factors (SEFs) ranging from 95 (for testosterone) to 149 (for methyltestosterone) were achieved by single stacking preconcentration. Then, the possibilities of multistep stacking to improve the sensitivity for these analytes were investigated. SEFs obtained by double stacking preconcentration ranged from 138 to 185, enabling concentration LODs of 2.79 x 10(-7) mol/L (for methyltestosterone), 3.47 x 10(-7) mol/L (for testosterone) and 3.56 x 10(-7) mol/L (for methandrostenolone). Although online triple stacking preconcentration was achieved, its repeatability was very poor and SEFs for the studied analytes were not calculated.  相似文献   

15.
Utilisation of a miniature anion-exchanger preconcentration column of Dowex 1-X8 to increase the sensitivity for As and Se determinations by inductively-coupled-plasma mass spectrometry (ICP-MS) is described. The ion signal was enhanced were 15 fold for As and 20 fold for Se. The multielement detection limits were 2 ppt (ng/L) and 33 ppt for As and Se, respectively. This flow injection ICP-MS method was applied to the determination of trace levels of arsenic and selenium in riverine reference material SLRS-2 and spring water samples.  相似文献   

16.
An on-line separation, preconcentration and determination system for vanadium(IV) and vanadium(V) comprising inductively coupled plasma optical emission spectrometry (ICP-OES) coupled to a flow injection (FI) method with an ultrasonic nebulization (USN) system was studied. The vanadium species were retained on an Amberlite XAD-7 resin as a vanadium-2-(5-bromo-2-pyridylazo)-5-diethylaminophenol (V-5-Br-PADAP) complex at pH 3.7. Enhanced selectivity was obtained with the combined use of the formation on-line of the complexes and 1,2-cyclohexanediaminetetraacetic acid (CDTA) as masking agent. The vanadium complexes were removed from the microcolumn with 25% v/v nitric acid. A sensitivity enhancement factor of 225 was obtained with respect to ICP-OES using pneumatic nebulization (15-fold for USN and 15-fold for the microcolumn). The detection limit for the preconcentration of 10 mL of aqueous solution was 19 ng L-1. The precision for 10 replicate determinations at the 5 micrograms L-1 V level was 2.3% relative standard deviation (RSD), calculated from the peak heights obtained. The calibration graph using the separation and preconcentration system for vanadium species was linear with a correlation coefficient of 0.9992 at levels from near the detection limits up to at least 100 micrograms L-1. The method was successfully applied to the speciation of vanadium in river water samples.  相似文献   

17.
A new method for the simultaneous chromatographic separation and determination of arsenite, arsenate, mono-methylarsonic acid, dimethylarsinic acid, selenite, selenate and hexavalent chromium in water is presented. Speciation was achieved by on-line coupling of anion-exchange LC and inductively coupled plasma mass spectrometry (ICP-MS). Optimisation of the chromatographic conditions led to baseline separation of the seven species in 14 min using gradient elution with NH4NO3 20 mM, pH 8.7-NH4NO3 60 mM, pH 8.7 as mobile phase. Detection limits are in the range 40-60 ng l(-1) for arsenic species, around 130 ng l(-1) for Cr(VI), and higher for Se(IV) and Se(VI) (1.2 and 1.4 microg l(-1) respectively). The method showed good accuracy and repeatability, and no interference of chloride on 75As, 77Se or 53Cr was observed. The developed method was applied to the analysis of several environmental surface water samples.  相似文献   

18.
A novel dual-cloud point extraction (dCPE) technique is proposed in this paper for the sample pretreatment of capillary electrophoresis (CE) speciation analysis of mercury. In dCPE, cloud point was carried out twice in a sample pretreatment. First, four mercury species, methylmercury (MeHg), ethylmercury (EtHg), phenylmercury (PhHg), and inorganic mercury (Hg(II)) formed hydrophobic complexes with 1-(2-pyridylazo)-2-naphthol (PAN). After heating and centrifuging, the complexes were extracted into the formed Triton X-114 surfactant-rich phase. Instead of the direct injection or analysis, the surfactant-rich phase containing the four Hg species was treated with 150 microL 0.1% (m/v) l-cysteine aqueous solution. The four Hg species were then transferred back into aqueous phase by forming hydrophilic Hg-l-cysteine complexes. After dCPE, the aqueous phase containing the Hg-l-cysteine complexes was subjected into electrophoretic capillary for mercury speciation analysis. Because the concentration of Triton X-114 in the extract after dCPE was only around critical micelle concentration, the adsorption of surfactant on the capillary wall and its possible influence on the sample injection and separation in traditional CPE were eliminated. Plus, the hydrophobic interfering species were removed thoroughly by using dCPE resulted in significant improvement in analysis selectivity. Using 10 mL sample, 17, 15, 45, and 52 of preconcentration factors for EtHg, MeHg, PhHg, and Hg(II) were obtained. With CE separation and on-line UV detection, the detection limits were 45.2, 47.5, 4.1, and 10.0 microg L(-1) (as Hg) for EtHg, MeHg, PhHg, and Hg(II), respectively. As an analysis method, the present dCPE-CE with UV detection obtained similar detection limits as of some CE-inductively coupled plasma mass spectrometry (ICPMS) hyphenation technique, but with simple instrumental setup and obviously low costs. Its utilization for Hg speciation was validated by the analysis of the spiked natural water and tilapia muscle samples.  相似文献   

19.
Zhang H  Zhou L  Chen X 《Electrophoresis》2008,29(7):1556-1564
An easy, simple, and highly efficient on-line preconcentration method for polyphenolic compounds in CE was developed. It combined two on-line concentration techniques, large-volume sample stacking (LVSS) and sweeping. The analytes preconcentration technique was carried out by pressure injection of large-volume sample followed by the EOF as a pump pushing the bulk of low-conductivity sample matrix out of the outlet of the capillary without the electrode polarity switching technique using five polyphenols as the model analytes. Identification and quantification of the analytes were performed by photodiode array UV (PDA) detection. The optimal BGE used for separation and preconcentration was a solution composed of 10 mM borate-90 mM sodium cholate (SC)-40% v/v ethylene glycol, without pH adjustment, the applied voltage was 27.5 kV. Under optimal preconcentration conditions (sample injection 99 s at 0.5 psi), the enhancement in the detection sensitivities of the peak height and peak area of the analytes using the on-line concentration technique was in the range of 18-26- and 23-44-fold comparing with the conventional injection mode (3 s). The detection limits for (-)-epigallocatechin (EGC), (-)-epicatechin (EC), (+)-catechin (C), (-)-epigallocatechin gallate (EGCG), and (-)-epicatechin gallate (ECG) were 4.3, 2.4, 2.2, 2.0, and 1.6 ng/mL, respectively. The five analytes were baseline-separated under the optimum conditions and the experimental results showed that preconcentration was well achieved.  相似文献   

20.
In this work, the analysis of a group of four fungicides (pyrimethanil, nuarimol, procymidone and cyprodinil) and one insecticide (pirimicarb) by micellar electrokinetic chromatography (MEKC) with UV detection using the on-line preconcentration strategy called reversed electrode polarity stacking mode (REPSM) is proposed. After optimisation, an adequate separation electrolyte for the separation and stacking of these pesticides was obtained which consisted of 100 mM borate, 60 mM sodium dodecyl sulphate (SDS), at pH 9.0 and 2% 2-propanol. The use of this running buffer together with the REPSM preconcentration method provided limits of detection (LODs) between 38.3 and 241 microg/L. In order to apply the developed methodology for the analysis of these pesticides in wine samples, several off-line preconcentration strategies (mainly, solid-phase extraction, SPE, and solid-phase microextraction, SPME) were tested. Although the use of a SPE procedure, optimized in this work for water samples, using Oasis HLB cartridges, provided mean recovery values between 79 and 100% for spiked water samples, it could not be applied to the extraction of these pesticides from wine samples due to high interference from the sample matrix. However, the use of a SPME procedure using polydimethylsiloxane/divynilbenzene (PDMS/DVB) fibers allowed the selective extraction of four of the five pesticides which could be perfectly determined. The final combination of the off-line SPME and on-line REPSM preconcentration strategies allowed obtaining LODs between 17.6 and 32.3 microg/L.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号