首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
On-line combination of partial filling capillary electrophoresis and electrospray ionization mass spectrometry was demonstrated for the simultaneous enantioseparation of tramadol and its main phase I metabolites. The partial filling technique was efficient at avoiding MS contamination by the chiral selector. Different experimental factors were investigated, including the chiral selector nature and concentration, plug length as well as the separation temperature. The best enantioseparation of the investigated compounds was achieved with a coated polyvinyl alcohol capillary and a 40 mM ammonium acetate buffer, pH 4.0, adding sulfobutyl ether beta-cyclodextrin (2.5 mg/ml) as the chiral selector. The charged cyclodextrin not only allowed enantioseparation of tramadol and its metabolites, but also improved the selectivity of compounds with the same molecular mass. Finally, CE-electrospray ionisation-MS was successfully applied to the stereoselective analysis of tramadol and its main metabolites in plasma after a simple liquid-liquid extraction.  相似文献   

2.
In forensic toxicology, hair analysis has become a well established analytical strategy to investigate retrospectively drug abuse histories. In this field, gas chromatography-mass spectrometry and high-performance liquid chromatography-mass spectrometry are currently used, often after preliminary screening with immunoassays. However, on the basis of previous applications to pharmaceutical analysis, capillary zone electrophoresis coupled to ion trap mass spectrometry looks also highly promising. The purpose of the present work was the development of a simple and rapid CZE-MS method for sensitive and quantitative determination of the main drugs of abuse and their metabolites (namely, 6-monoacetylmorphine, morphine, amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine (MDA), 3,4-methylenedioxymethampthetamine (MDMA), benzoylecgonine, ephedrine and cocaine) in human hair. Hair samples (100 mg) were washed, cut and incubated overnight in 0.1 M HCl at 45 degrees C, then neutralized with NaOH and extracted by a liquid-liquid extraction method. CZE separations were carried out in a 100 cm x 75 microm (I.D.) uncoated fused silica capillary. The separation buffer was composed of 25 mM ammonium formate, pH 9.5; the separation voltage was 15 kV. Electrokinetic injections were performed at 7 kV for 30 s under field amplified sample stacking conditions. ESI-ion trap MS detection was performed in the ESI positive ionization mode using the following conditions: capillary voltage 4 kV, nebulizer gas (nitrogen) pressure 3psi, source temperature 150 degrees C and drying gas (nitrogen) flow rate 8l/min. A sheath liquid, composed of isopropanol-water (50:50, v/v) with 0.5% formic acid, was delivered at a flow rate of 4 microl/min. The ion trap MS operated in a selected ion monitoring mode (SIM) of positive molecular ions for each drug/metabolite. Collision induced fragmentation was also possible. Nalorphine was used as internal standard. Under the described conditions, the separation of all compounds, except amphetamine/methamphetamine, MDA/MDMA and morphine/6-MAM was achieved in 20 min, with limits of detection lower than the most severe cut-offs adopted in hair analysis (i.e. 0.1 ng/mg). Linearity was assessed within drug concentration ranges from 0.025 to 5 ng of each analyte/mg of hair. Analytical precision was fairly acceptable with RSD's < or = 3.06% for migration times and < or = 22.47% for areas in real samples, in both intra-day and day-to-day experiments. On these grounds, the described method can be proposed for rapid, selective and accurate toxicological hair analysis for both clinical and forensic purposes.  相似文献   

3.
张含智  李凤  康经武 《色谱》2023,41(2):160-167
毛细管电泳-质谱联用技术具有分离效率高、检测灵敏度高、样品消耗量少,可同时提供样品的结构信息等优点,成为复杂样品分离分析的强有力工具。但是,毛细管电泳与质谱联用的接口技术依然未能很好的解决。为了拓展我们发展的金箔包裹的毛细管电泳分离柱尖端直接作为喷雾电极和无鞘流质谱接口的应用,本文报道了用无鞘流接口毛细管电泳-电喷雾质谱联用(CE-ESI-MS)分析5种酪氨酸激酶抑制剂(舒尼替尼、甲磺酸伊马替尼、吉非替尼、达沙替尼、埃罗替尼)的研究结果。这种接口集分离与电喷雾离子化于一根毛细管中,制作简单,成本低廉,且可批量制作。实验发现采用非水毛细管电泳分离模式不仅可以对5种酪氨酸激酶抑制剂实现基线分离,而且可以获得稳定的质谱信号。考察了电解质溶液组成对分离效果的影响,得到优化的背景电解质组成,即含2%(v/v)乙酸及5 mmol/L乙酸铵的乙腈-甲醇(80∶20, v/v)混合溶剂。在优化的条件下,5种激酶抑制剂可以得到基线分离,无鞘接口也可以长时间保持稳定的电喷雾,分析物的保留时间日内、日间重复性(RSD值)分别小于0.5%和0.8%,接口批次间的RSD值小于2.6%。与水相分离条件下的CE-MS对比,非水相条件下的5种酪氨酸激酶抑制剂的分离柱效更高,检测灵敏度更高,绝对检出限达到amol级。此外,采用无鞘流CE-MS分析了各类有机酸(千层纸素A、丹酚酸C和迷迭香酸)和脂溶性的大环内酯类抗生素(阿奇霉素、红霉素和环孢素A),均可以获得良好的分离效果和质谱检测结果。  相似文献   

4.
A pressure-assisted capillary electrophoresis-ion trap mass spectrometry method was developed for the analysis of eight heparin-derived disaccharides. A 30 mM formic acid buffer at pH 3.20 was selected as running electrolyte, and the separation was performed by the simultaneous application of a CE voltage of -30 kV and an overimposed pressure of 0.5 p.s.i. (3.45 kPa). The application of pressure assistance was needed to provide stable electrospray conditions for successful coupling. The linearity of the CE-MS and CE-MS-MS methods was checked under these conditions. Quality parameters such as run-to-run precision and limits of detection were established in both CE-MS and CE-MS-MS modes. Finally, enzymatically depolymerised bovine and porcine mucosal heparins were analysed in this CE-MS system and the characteristic relative molar percentages of major and minor disaccharides were calculated.  相似文献   

5.
We describe a method to identify and quantify amino acids using capillary electrophoresis-electrospray ionization-triple-quadrupole tandem mass spectrometry (CE-ESI-MS/MS). Amino acids, including physiological amino acids, were first separated by CE under acidic pH conditions and then detected by MS/MS. To efficiently introduce the whole sample into the capillary, no electrical potential was applied to the electrospray probe until running electrophoresis. The position of the electrosprayer with respect to the MS capillary entrance drastically affected sensitivity and generation of cluster ions. MS/MS with multiple reaction monitoring (MRM) detection was performed to obtain sufficient selectivity and sensitivity. Under optimized CE-MS/MS conditions, the minimum detectable levels for 32 free amino acids normally found in proteins and other physiological amino acids were between 0.1 and 14 micromol/L with pressure injection of 50 mbar for 3 s (3 nL) at a signal-to-noise ratio of 3. For most amino acids, this constitutes a severalfold increase in sensitivity compared to CE-MS. The relative standard deviations (% RSD) for all amino acids were better than 0.4% for migration times and between 1.4% and 8.6% for peak areas (n = 10). Since amino acids exhibited characteristic MS/MS spectra, this approach is useful for the simultaneous, selective, quantitative, and reproducible analysis of amino acids in physiological and biological samples that contain various kinds of matrices. The power of the method was demonstrated by analyzing amino acids in human urine.  相似文献   

6.
The prediction of peptide mobility by capillary electrophoresis (CE) coupled to electrospray mass spectrometry (MS) is studied in order to verify the validity of the semi-empirical models developed in classical CE. This work relies on the experimental determination of the electrophoretic mobilities of 68 peptides, different in charge and in size. The results indicate that the prediction is possible in CE-MS experiments, in spite of the restraints inherent in the coupling conditions. The best fit of experimental data was obtained with the Offord's model. The efficiency of the model was confirmed by the analysis of a peptide mixture in CE-MS.  相似文献   

7.
A new method for the simultaneous separation of cocaine and four metabolites in urine by CE-ESI-MS via a pressurized nanoliquid junction interface was developed. The resolution of cocaine, cocaethylene, benzoylecgonine, norcocaine, and ecgonine methyl ester was achieved in a polyvinyl-alcohol-coated capillary with 75 μm id × 50 cm total length, using a 15 mM ammonium formate electrolyte solution (pH 9.5) in less than 15 min. In addition, to enhance sensitivity, a field-amplified sample injection (FASI) was evaluated in terms of injection time and sample solvent composition. The limits of detection achieved with the FASI method ranged from 1.5 to 10 ng/mL for all the compounds. The detection of the studied compounds was performed using an ion-trap mass spectrometer in a positive ionization mode. A mixture of methanol:water (80:20 v/v) containing 0.1% v/v of formic acid was employed as spray liquid and delivered at ~200 nL/min. Under optimal CE-MS conditions, linearity was assessed in the concentration range of interest for all analytes with correlation coefficients r2 ≥ 0.9913. Intra- and inter-day precision provided a relative standard deviation lower than 1.54% for migration times and lower than 12.15% for peak areas. Finally, urine samples, spiked with the standard mixture, were extracted using a solid-phase extraction procedure and injected under FASI conditions, providing recoveries from 80% to 94% for all analytes.  相似文献   

8.
The applicability in capillary electrophoresis-electrospray mass spectrometry (CE-ESI-MS) of the classical semiempirical relationships between electrophoretic mobility and charge-to-mass ratio (me versus q/Malpha) has been investigated in order to describe the migration behavior of a series of bioactive peptide hormones. The influence upon the models of the separation electrolyte pH and the accuracy of the pK values of these compounds were studied first by capillary electrophoresis with ultraviolet detection (CE-UV). The classical polymer model, alpha = 1/2, resulted in slightly better correlations at any of the studied pH. Furthermore, a general linear equation can be adjusted combining all the experimental data pairs, which suggests that correlation in the whole pH range is independent of the ionic form of the studied peptide hormones. The plots of q/M1/2 against separation electrolyte pH were used to predict their electrophoretic separations, using the accurate pK values obtained in a previous work by CE-UV for charge calculations. A volatile separation electrolyte containing 50 mM of acetic acid and 50 mM of formic acid at pH 2.85 was selected for optimum CE-UV and CE-ESI-MS analysis of the peptide mixture. At this pH and taking into account the specific features of the coupling, the correlation using the classical polymer law was excellent and its parameters were similar to the ones of the general linear equation previously obtained by CE-UV. This confirmed the applicability in CE-ESI-MS of the semiempirical relationship originally established by CE-UV.  相似文献   

9.
The applicability of a capillary zone electrophoresis–electrospray ionisation tandem mass spectrometric (CZE–ESI-MS–MS) method for the separation of nine fluoroquinolones was investigated. Method optimisation involved systematic trouble-shooting starting with the type and duration of capillary pre-washing and conditioning, the choice of both the CE run buffer, MS sheath liquid, CE run potential, ESI spray voltage, sheath gas flow-rate, MS capillary voltage and CE capillary and MS capillary temperatures. Another extremely important factor was found to be the degree to which the CE capillary protrudes into the ESI chamber as well as whether or not sheath gas and spray voltage are employed during the CE injection or not. The importance of the latter has, to our knowledge, not been addressed elsewhere. Nine fluoroquinolones have been separated and detected in a single run by this technique.  相似文献   

10.
The dimensions of the capillaries used to construct a typical coaxial capillary electrophoresis-mass spectrometry (CE-MS) interface, i.e. the inner diameter, the outer diameter and the wall thickness, have been shown to affect the performance of the CE-MS system. The influence of these parameters has been investigated in both MS and MS-MS modes. The initial results indicate that by reducing all the sheath capillaries' dimensions and the CE capillary outer diameter, better operation and increased sensitivity can be achieved. The capillary arrangement which gives optimum sensitivity and stable operation has been suggested.  相似文献   

11.
The use of the electrospray ionization (ESI) method for interfacing capillary electrophoresis with mass spectrometry (CE-MS) is particularly well suited for the analysis of large molecules due to the multiple charging phenomenon. While ionization efficiency is very high, the available ion current is dispersed over more peaks so that the maximum peak intensity obtainable declines significantly for large molecules. Sensitivity with ESI can be improved by operation at very low flow-rates, an ideal situation for CE-MS. These and other considerations related to sensitivity are illustrated using ESI-MS measurements for cytochrome c.  相似文献   

12.
Clotting factor IX preparations from human plasma (pdFIX) have been characterized using electrophoretic methods like sodium dodecyl sulfate-polyacrylamide gel electrophoresis, isoelectric focusing and two-dimensional polyacrylamide gel electrophoresis. Factor IX prior to and after activation with factor XIa was separated by one- and two-dimensional polyacrylamide gel electrophoresis and on isoelectric focusing gels. The main differences between the band patterns of the two pdFIX preparations are due to their purity. Vitronectin was identified by immunological techniques as major accompanying plasma protein, separated from factor IX and characterized by isoelectric focusing and two-dimensional polyacrylamide gel electrophoresis.  相似文献   

13.
The present work was aimed at the development of a capillary electrophoretic analysis of gamma-hydroxybutyric acid (GHB) using electrospray ion trap mass spectrometry to achieve the direct and unequivocal detection of this analyte in human urine. Optimized capillary electrophoretic conditions were: injection, 20 s at 0.5 psi (1 psi = 6894.76 Pa); buffer electrolyte, 12.5 mM ammonium formate adjusted to pH 8.35 with diethylamine; fused silicacapillary: 100 cm x 50 microm i.d.; separation voltage, 25 kV (forward polarity) + 0.5 psi; room temperature. Electrospray and mass spectrometric conditions were: drying gas and nebulizing gas (nitrogen) at flow rate 3 l/min, temperature 250 degrees C, nebulizer pressure: 10 psi; sheath liquid solution: methanol-water (90:10) containing 0.1% ammonia delivered at 3 microl/min; spray voltage 3.5 kV. Mass spetrometric detection was carried out in the selected ion monitoring mode of negative molecular ions at 103 m/z for GHB and 115 m/z for maleic acid (I.S.). Under these conditions the baseline separation of GHB and the I.S. was obtained. The selectivity of the analysis allowed for direct injection of unextracted urine, previously diluted 1:4 with water. Linearity was assessed in the GHB concentration range from 80 to 1280 microg/ml in urine. Analytical sensitivity (as limit of detection) resulted about 5 microg/ml in water and 20 microg/ml in original urine. Analytical precision was fairly acceptable with R.S.D. values lower than 5% for migration times and 18% for quantitation in real samples, in both intra day and day-to-day experiments. On these grounds, the developed method can be adopted for rapid identification of acute intoxications from GHB in humans.  相似文献   

14.
Smyth WF 《Electrophoresis》2005,26(7-8):1334-1357
A critical review of applications for the period 2000-2004, taken from the Web of Knowledge database, of the technique capillary electrophoresis-electrospray ionisation-mass spectrometry (CE-ESI-MS) in drug analysis is presented. The review is concerned with molecules of mass less than 500 Da, chosen according to selected structural classes in which they give ESI signals primarily as [M+H](+) ions although other ions, such as [M-H](-), [M+Na](+), and [M+NH(4)](+), are also reported. These structural classes are drugs with amine-containing side chains, drugs with N-containing saturated ring structures, 1,4-benzodiazepines, other heterocyclic hypnotics, carbohydrates, sulphonylureas, anthracyclines, sulphonamides, penicillins, cephalosporins, tetracyclines, nitrocatechols, steroids, flavonoids/polyphenols, cannabinols, and miscellaneous molecules. Details are given on the fragmentations, where available, that these ionic species exhibit in-source and in ion-trap, triple quadrupole, and time of flight-mass spectrometers. The review gives a critical evaluation of these recent CE-ESI-MS analytical methods in drug analysis. Analytical information on, for example, sample concentration techniques, CE separation conditions, recoveries from biological media and limits of detection (LODs) are provided. Potential applications of CE-MS to particular drugs or drug classes are also briefly discussed in the text.  相似文献   

15.
Smyth WF 《Electrophoresis》2006,27(11):2051-2062
This review considers applications in 2004-2005 of capillary electrophoresis-electrospray ionisation-mass spectrometry (CE-ESI-MS) to the detection and determination of small molecular mass drug molecules, taken from the Web of Knowledge database. The molecules of small molecular mass less than 1000 Da are chosen according to selected structural classes in which they give ESI signals primarily as [M + H](+) ions. These structural classes are drugs with amine-containing side chains, drugs with N-containing saturated ring structures, 1,4-benzodiazepines, other heterocyclic hypnotics, steroids, bioactive compounds containing phenolic groups, and miscellaneous molecules. Details are given on the fragmentations, where available, that these ionic species exhibit in-source and in ion-trap, triple quadrupole and time-of flight mass spectrometers. The review then gives a critical evaluation of these recent CE-ESI-MS analytical methods for the detection and determination of these small molecular mass drug molecules. Analytical information on, for example, sample concentration techniques, CE separation conditions, recoveries from biological media and limits of detection are provided.  相似文献   

16.
A capillary zone electrophoresis-electrospray ionization-mass spectrometry (CZE-ESI-MS) method was developed to facilitate identification and determination of eleven low-molecular-mass (LMW) organic acids (i.e. oxalic, lactic, malonic, maleic, citric, tartaric, adipic, glutaric, gluconic, isosaccharinic and succinic acid) in different sample matrices. This CZE method was adapted to suit MS conditions. Sheath liquid, sheath flow and MS parameters were optimized to achieve high mass spectrometric sensitivity. The CZE-ESI-MS procedure showed good sensitivity (limit of detection of < 0.05-0.7 mg/l for all acids), linearity (r2 = 0.9925-0.9998) and reproducibility (2.09-5.34% RSD). The applicability of the CZE-ESI-MS was demonstrated on LMW organic acids in an ale sample. In addition the (here presented) method also provided quantification of fumaric, galacturonic and 2-ketoglutaric acid with high sensitivity.  相似文献   

17.
Mass spectrometry (MS) has become a key tool for the characterization of biologically relevant molecules in the last decade. Due to the complexity of most biological samples an upstream separation is essential. Capillary electrophoresis (CE) has gained much interest due to its high separation efficiency, speed, and often complementary selectivity to liquid chromatography. We describe the state-of-the-art of on-line CE-MS for the analysis of molecules of biological origin. The characterization of peptides, including the study of post-translational modifications, intact proteins, oligonucleotides, and related interaction studies are reviewed. Relevant publications are summarized in tables, including some important method parameters. Key applications are discussed with respect to the advantages and limitations of CE-MS. Coupling interfaces, preconcentration techniques, capillary coatings, and the different CE techniques, e.g., capillary zone electrophoresis, capillary isoelectric focusing, capillary gel electrophoresis, etc. are briefly discussed against the background of their bioanalytical applications.  相似文献   

18.
Monolithically integrated, polymer (SU-8) microchips comprising an electrophoretic separation unit, a sheath flow interface and an ESI emitter were developed to improve the speed and throughput of proteomics analyses. Validation of the microchip method was performed based on peptide mass fingerprinting and single peptide sequencing of selected protein standards. Rapid, yet reliable identification of four biologically important proteins (cytochrome C, β-lactoglobulin, ovalbumin and BSA) confirmed the applicability of the SU-8 microchips to ambitious proteomic applications and allowed their use in the analysis of human muscle cell lysates. The characteristic tryptic peptides were easily separated with plate numbers approaching 10(6), and with peak widths at half height as low as 0.6 s. The on-chip sheath flow interface was also exploited to the introduction of an internal mass calibrant along with the sheath liquid which enabled accurate mass measurements by high-resolution Q-TOF MS. Additionally, peptide structural characterization and protein identification based on MS/MS fragmentation data of a single tryptic peptide was obtained using an ion trap instrument. Protein sequence coverages exceeding 50% were routinely obtained without any pretreatment of the proteolytic samples and a typical total analysis time from sampling to detection was well below ten minutes. In conclusion, monolithically integrated, dead-volume-free, SU-8 microchips proved to be a promising platform for fast and reliable analysis of complex proteomic samples. Good analytical performance of the microchips was shown by performing both peptide mass fingerprinting of complex cell lysates and protein identification based on single peptide sequencing.  相似文献   

19.
Supercritical fluid chromatography with inductively coupled plasma-mass spectrometric detection is a new and useful technique for the analysis of organometallic compounds. An interface has been developed for coupling these techniques. The interface is compact, easy to assembel, and causes minimal disruption to either instrument. A series of organotin, organoarsenic, and organorion compounds has been used to evaluate the interface and ICPMS as a detector for SFC. The effect of analyte concentration and restrictor temperature on peak intensity has been investigated and the effect of the mobile phase on the plasma has also been studied to assess background interference from changes in the plasma.  相似文献   

20.
This short communication describes the characterization of seven tropane alkaloid compounds in Atropa belladonna L. Thus a rapid and easy CE-electrospray interface (ESI)-TOF-MS procedure is developed to analyze these compounds in a pharmaceutical preparations of A. belladonna L. leaf extract. Optimum electrophoretic separation is obtained using an alkaline solution of 60 mM ammonium acetate at pH 8.5 containing 5% isopropanol. Under the optimum CE-ESI-TOF-MS conditions several important compounds such as tropine, belladonnine, norhyoscyamine, apoatropine, hyoscyamine, 6beta-hydroxyhyoscyamine, and scopolamine have been simultaneously identified from A. belladonna L. CE-ESI-IT-MS has been used to discriminate the putative presence of littorine. The sensitivity, together with mass accuracy and true isotopic pattern of the TOF-MS, allowed the identification of a broad series of tropane alkaloid compounds present in pharmaceutical preparations of A. belladonna L. leaf extract.  相似文献   