首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 171 毫秒
1.
采用微波消解样品,电感耦合等离子体质谱仪测定了茉莉花,熏衣草,甜菊叶,玫瑰花,菊花和桂花等6种花茶的Zn,As,Cd,Pb,Tl,Cr,Ni和Cu等元素的含量及其溶出特性。所采用方法的加标回收率在80%~120%之间,相对标准偏差小于6%。各样品的元素含量在下列范围内变动:Zn(18~48μg/g),As(2~14μg/g),Cd(0.05~1μg/g),Pb(0.8~9μg/g),Tl(0.08~2μg/g),Cr(0.8~3.9μg/g),Ni(0.6~11.5μg/g),Cu(6~27μg/g),样品中的元素溶出量均呈现随溶出时间延长而增加的趋势。本测定结果为这些花茶的消费行为以及研发花茶新产品提供了实验依据。  相似文献   

2.
采用C8固相萃取柱,建立了固相萃取-石墨炉原子吸收测定海水中Pb,Cd,Cu的方法,优化了固相萃取的吸附和解析条件。测定Pb,Cu线性范围为0~100μg/L,Cd线性范围为0~4μg/L,相关系数(r)不低于0.9993。Pb,Cd,Cu检出限(3σ,n=11)分别为0.66,0.023和0.48μg/L;标准偏差分别为4.0%,0.84%和4.4%;加标回收率分别为102%,96%和97.3%。方法能有效克服海水中复杂基体干扰问题,已用于海水样品中痕量Pb,Cd,Cu的测定。  相似文献   

3.
林光西  蒋萧茹 《分析试验室》2014,(11):1335-1337
采用黄原脂棉富集技术,建立了电感耦合等离子质谱法测定海水中重金属Cu,Pb,Zn,Co,Cd含量的方法。完善前处理条件,优化仪器工作参数,选取Rh,Ir作为内标元素,有效克服基体效应及仪器波动影响。Cu,Pb,Zn,Co,Cd的检出限分别为1.26,0.21,0.24,0.0027,0.0051μg/L,RSD为0.77%~3.3%,回收率为87.2%~96.0%。方法适用于海水中重金属元素的含量测定。  相似文献   

4.
建立电感耦合等离子体质谱法测定电泳涂料中15种金属元素的分析方法。以微波灰化方式处理样品,采用碰撞诱导解离(CID)-动能歧视(KED)联合模式消除质谱干扰,实现高浓度元素和痕量元素的同时检测;采取气体稀释模式降低基体干扰并减少高浓度元素对质量检测器的损害。Na、Mg、Al、K、Ca、Fe和Zn质量浓度在0.01~10.0mg/L范围内,Cu、Mn、Ni、Co、Cr、Cd、Ba和Pb的质量浓度在1.0~1000.0 g/L范围内线性关系良好,线性相关系数为0.9991~0.9999,方法检出限为0.3~23μg/kg。测定结果的相对标准偏差为0.6%~3.2%(n=6),样品加标回收率为91.5%~107.0%。该方法可用于汽车电泳涂料中金属元素的检测。  相似文献   

5.
粪便样品干燥、研磨后,称取0.25 g样品,加入8 mL硝酸,采用微波消解方法进行前处理。采用KED模式消除质谱干扰,采用内标校正消除非质谱干扰(Ge作为Cu、Zn、Cr的内标,Bi作为Hg和Pb的内标,Rh作为As和Cd的内标),建立了可同时测定畜禽粪便中Cu、Zn、Cr、As、Cd、Pb、Hg 7种重金属元素的微波消解-电感耦合等离子体质谱法。方法线性相关系数均在0.9995以上,检出限为0.005~0.305μg/L,加标回收率为83.6%~112%,相对标准偏差为0.70%~5.6%。方法灵敏度、准确度和精密度高,实用性强,适用于同时检测畜禽粪便中多种重金属元素,对畜禽粪便的科学还田具有指导意义。  相似文献   

6.
本文以微波辅助消解为样品前处理方法,建立了电感耦合等离子体原子发射光谱法(ICP-OES)测定烟草中Cu、Zn、Cr、Cd、Pb、Mn、Fe 7种重金属含量的分析方法。结果表明:该方法 Pb的检出限为2.00μg/L,其他元素检出限均小于0.90μg/L,回收率在86.1%~116.4%之间,相对标准偏差(RSD)在1.1%~8.1%范围。方法已成功用于部分国内外烟草中的重金属含量检测。  相似文献   

7.
建立了HNO3-H2O2湿法消解、电感耦合等离子体质谱(ICP-MS)同时测定PM2.5样品中痕量重金属Cr,Ni,Cu,As,Cd,Pb和Pb同位素的方法。通过内标校正克服了基体效应、物理效应和仪器的长短期漂移的干扰。在ICP-MS优化参数下,测定的痕量元素及Pb同位素的标准曲线相关系数均优于0.9997,5种痕量元素的方法检出限在0.01~0.07μg/L之间,4种Pb同位素的方法检出限在0.014~0.07μg/L之间。通过测定滤膜标准物质(GBW(E)080212)和Pb同位素标准物质(NIST981)考察了方法准确性,测定值均在标准值范围内。当Pb质量浓度大于10μg/L时,浓度对Pb同位素比值的测量影响不显著。运用该方法测得厦门市PM2.5中6种痕量重金属元素的RSD小于4.8%,Pb同位素RSD小于0.5%。  相似文献   

8.
建立了电感耦合等离子体质谱法(ICP-MS)混合模式测定动植物源食品中11种痕量元素的检测方法。样品经微波消解后,采用混合模式测定动植物源食品中As,Hg,Pb,Cd,Cr,Co,Ni,Cu,Zn,Fe,M n 11种元素,内标法定量。结果表明:11种元素的检出限分别在0.005~0.09μg/L之间;线性关系良好,相关系数r≥0.9995;相对标准偏差(RSD)为0.94%~7.2%;回收率在90.7%~103.5%之间;对不同食品类型的对照标准样品GBW10016、GBW10018、GBW10044、GBW10051进行测定,测定结果均在参考值范围。本方法适用于批量动植物源食品中多元素的同时测定。  相似文献   

9.
高分辨等离子体质谱法直接测定高纯镓中的痕量元素   总被引:9,自引:0,他引:9  
谢华林  聂西度  唐有根 《分析化学》2006,34(11):1570-1574
建立高分辨电感耦合等离子体质谱法(HR-ICP-MS)测定高纯镓样品中Be、Mg、A l、S i、Ti、V、Cr、Mn、Fe、Co、N i、Cu、Zn、Ge、As、Mo、Ag、Cd、In、Sb、Ba、Pb、B i等痕量元素的方法。样品用HNO3 HC l经微波消解后,试液直接进样用HR-ICP-MS法同时测定上述元素,在高分辨质谱测量模式下避免了大量的质谱干扰,详细地研究了HC l和高纯镓所产生的基体效应,以Sc、Rh、Tl作为内标元素校正了基体效应,讨论和确定了实验的最佳测定条件。结果表明,23种痕量元素的检出限在0.001~0.21μg/L之间;回收率在89.8%~111.6%之间,相对标准偏差(RSD)小于3.3%。  相似文献   

10.
采用半密闭酸溶消解法处理样品,选择离线校正的方式校正了Sn对Cd的同量异位素的干扰,增加积分时间和读数次数提高了Cd的准确度和精密度,建立了电感耦合等离子体质谱仪(ICP-MS)测定化探样品中Cr、Ni、Cu、Zn、Cd、Pb六种重金属元素的方法。对前处理方法和仪器的参数条件进行了优化,结果表明,半密闭体系可达到回流的目的,样品分解完全且无污染现象,在最优的实验条件下,标准曲线的相关系数均不小于0.9997,检出限为0.019~1.65 μg/g ,测定下限为0.057~4.95 μg/g 。按照实验方法对岩石、水系沉积物和土壤国家标准物质中Cr、Ni、Cu、Zn、Cd、Pb平行测定12次,各元素的测定结果与认定值基本一致,相对偏差均不大于3.55%,相对误差均不大于 10.34% 。采用实验方法对土壤样品进行分析,测定结果与四酸溶解-ICP-OES测定Cr、Ni、Cu、Zn、Pb,火焰-石墨炉原子吸收法测定Cd的结果基本吻合。  相似文献   

11.
采用原子吸收光谱法测定了皇冠草地上部分所含微量元素铜、锰、锌、铁、镉、铅、铬.结果表明,皇冠草地上部分含有较丰富的铜、锰、锌、铁,RSD≤4.23%(n=4),加标回收率99.20%~103.00%.  相似文献   

12.
利用乙醇-水-稀硝酸乳化体系分散溶解甲苯样品,建立了电感耦合等离子体质谱(ICP-MS)同时测定甲苯中V、Cr、Mn、Fe、 Co、Ni、Cu、Zn、Ag、Cd及Pb等微量金属元素的新方法。采用有机进样系统,以Re多元素混标为内标元素,优化了仪器射频功率、载气流速、采样深度等仪器参数,以及乙醇-水比例和硝酸含量等样品前处理条件。结果表明,在最佳实验条件下,甲苯中多数微量金属元素的检出限均可达 ng/L级,各元素的线性关系良好(线性系数r=0.998 4~1.000);方法精密度较高,相对标准偏差(RSD)不大于8.0%;准确度和重现性较好,相对误差不高于10%。对不同厂家的甲苯样品进行分析,结果发现不同厂家样品的Zn、Mn与Co元素差异较大。该方法能够对不同厂家来源的甲苯进行区分,从而为实现海洋泄漏污染工业苯系物的鉴别提供一种新的辅助分析方法。  相似文献   

13.
The main difficulties of trace metals analysis in estuarine and seawater stem from their very low concentration (mug/l to sub-mug/l), and, by contrast, the high salt content (up to 38 g/l in the Mediterranean Sea). ICP-MS allows multi-elemental analysis and offers great sensitivity, but may be strongly affected by matrix effects induced by high salt contents (> 1 g/l). To perform trace metals analysis both in riverine, estuarine and seawater, we have developed a hyphenated method: ion chelation chromatography coupled on-line with ICP-MS. Iminodiacetate resin, Metpac CC-1 (Dionex), was used to concentrate most of the trace metals, and to separate them from alkaline and alkaline-earth metals. Behaviour of 17 elements (Pb, Cu, Cd, Ni, U, Cr, Mn, Al, Co, Ga, In, Zn, V, Tl, Bi, Ag and Sn) towards the resin was qualitatively investigated. A method validation, partly derived from AFNOR standard XPT 90-210, was carried out on 12 elements (Pb, Cu, Cd, Ni, U, Cr, Mn, Al, Co, Ga, Bi and In). Replicate measurements of multi-elemental standard solutions were used to check linearity, and to determine repeatability and detection limits. Method accuracy was then assessed by analysing two certified materials: a synthetic freshwater (SRM 1643d), and a natural filtered coastal seawater (NRCC CASS-3). An application assay of natural samples from the Rh?ne river (France) was eventually carried out, and the analytical results were found to be consistent with previous works.  相似文献   

14.
国家食品药品监督管理总局的2014年国家药品抽验计划将柏子养心片定为抽验品种,本实验利用人工胃液仿生提取样品可溶性重金属,通过微波消解技术对提取液进行消解处理,建立了仿生提取-ICP-MS法测定18批柏子养心片中 Co, Cr, Cu, Ba, Cd, Mn, Ni, Pb, Hg, Sr, Zn 11种可溶性重金属的含量的分析方法。本方法各元素标准系列线性回归方程的相关系数为0.9989~1.0000,检出限为0.19~5.6μg/ L,方法的重复性 RSD 值均小于6.2%,精密度的 RSD 值均小于5.6%,加标回收率在87.7%~101.9%之间,满足检测要求。参照《药用植物及制剂进出口绿色行业标准》规定的重金属限量标准,18批样品中 Pb, Cd, Cu 均未超过标准,Hg 含量平均值为7.68 mg/ kg,超过标准值。仿生提取-ICP-MS 法的建立为柏子养心片的安全性研究提供参考依据。  相似文献   

15.
微波消解-GFAAS测定浅水湖泊底泥中重金属元素   总被引:1,自引:0,他引:1  
探讨了采用微波消解作为底泥样品的前处理方法,运用石墨炉原子吸收法测定浅水湖泊底泥中Cu,Pb,Zn,Cd,Cr含量的实验条件.方法的RSD为2.0%~4.1%,平均回收率为97.4%~101.5%,Cu,Pb,Zn,Cd,Cr的检出限分别为0.4,5,2.8,0.25,2.5ng.该法适合于浅水湖泊底泥中重金属含量的测定.  相似文献   

16.
松口蘑中微量元素的测定   总被引:1,自引:0,他引:1  
采用火焰原子吸收法同时测定了松口蘑中K、Ca、Na、Mg、Fe、Pb、Cd、Co、Cr、Zn、Mn、Cu等12种元素的含量。方法的相对标准偏差在0.08%-2.32%范围,回收率在97.1%-108.3%范围。结果表明,在三种松口蘑样品中,除含有较高的K、Na、Ca、Mg和一定量的有害元素Cd、Pb外,其余6种对人体有益的微量元素较为丰富。  相似文献   

17.
火焰原子吸收法测定夏枯草果穗的微量元素   总被引:5,自引:0,他引:5  
使用灰化法处理样品,火焰原子吸收光谱法测定夏枯草果穗中的铬、银、锌、镍、镉、铁、铜的含量。结果表明,除Ag元素未检出外,夏枯草果穗的微量元素含量Cr、Zn、Ni、Cd、Fe、Cu分别为1.024、1.096、36.152、0.580、0.656、6.872μg/g,各元素含量由高到低顺序为:Ni,Cu,Zn,Cr,Fe,Cd,加标回收率为98.6%~115.2%,该法测定快速、简单,原子吸收光谱法测定夏枯草果穗中微量元素具有可行性。  相似文献   

18.
中药煎制前后重金属含量测定及溶出特性研究   总被引:1,自引:0,他引:1  
模拟传统煎药方式,制备中药水煎液,建立微波消解-电感耦合等离子体质谱法(ICP- MS)测定5种药材及其水煎液中6种重金属元素Pb、Cd、Cr、Cu、As、Hg含量的方法,研究并优化了微波消解条件及(ICP- MS)的各项技术参数.被测元素检出限为0.0001 ~0.003 μg/L,测定结果的相对标准偏差为1.8~3...  相似文献   

19.
建立了电感耦合等离子体质谱(ICP-MS)法测定果蔬类、大米等农产品样品中痕量元素的方法.样品通过HNO3-H2 O2混酸体系微波消解,以Rh作为内标溶液消除基体干扰,在仪器最佳条件下测定植物样中镉、铅、铬、铜、镍、锌6种痕量元素.方法的检出限为0.002~0.5μg/g;相对标准偏差(RSD)为0.84% ~7.4%...  相似文献   

20.
The current BCR procedure for metal fractionation recommended by the Standard Measurement and Testing Programme requires rather time-consuming sample pretreatment. Ultrasonic energy seems to be an attractive alternative for leaching metal from solid samples into a liquid extractant phase. This study aims at optimizing ultrasonic extraction in order to replace the BCR method of leaching using acetic acid and to apply the procedure of assessing element mobility in bottom sediment rich in moderately soluble carbonate minerals. The application of ICP-MS allowed the determination of As, Cd, Cr, Cu, Pb, Ni, Tl and Zn in extracts, in a wide range of concentration without any special treatment. Finally, 40’min extraction in an ultrasonic bath was proposed for evaluation of the mobile fraction of As, Cd, Cr, Cu, Pb and Zn as an assessment of environmental risk. The recovery of the ultrasound-assisted extraction in comparison to the shake-filter method, as applied in the common BCR procedure, was slightly higher than 100% for As, Cr and Pb, reasonably high (about 70%) for Cd, Zn and Cd, but did not exceed 21% for Tl. Also, the mobility and extractability (relative mobility) of the studied elements from sediment collected over one year were compares. According to the results obtained after 40’min of ultrasound-assisted extraction it can be concluded that mobility did not change over one year for Cr, Cu, As, Cd, Ni and Tl, but noticeable differences for Zn and Pb were observed. The total content of all studied elements was almost the same in samples taken in the years 2003 and 2004, respectively.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号