1.
The slurry technique was applied to the determination of Ni, Cr and Co in wheat flour by electrothermal atomic absorption spectrometry (ETAAS). The influence of the graphite furnace temperature programme was optimized. Optimum sensitivity was obtained by using a mixture of 15% HNO3–10% H2O2 as suspended medium for a 3% w/v slurry in the determination of Ni; lower concentrations of HNO3 were necessary for the determination of Co and Cr (viz. 5 and 10%). The precision of direct analyses of the slurries was improved by using mechanical agitation between measurements; thus, the RSD of the measurements was ca. 5% for repeatability. The direct slurry sampling (SS) technique is suitable for the determination of Ni and Cr in wheat flour samples at levels of 150–450 and 30–72 ng g−1, respectively, as it provides results similar to those obtained by ashing the sample. However, the typically low level of Co in these samples precluded its determination by the proposed method (the study was made in an SRM spiked wholemeal flour), at least in those samples that were contaminated with elevated concentrations of the metal (viz. more than 90 ng of Co per g of flour). The method provides a relative standard deviation of 6, 8, and 4% for Ni, Cr, and Co, respectively.  相似文献   

2.
Iridium and ruthenium, alone and in combination with tungsten, thermally deposited on the platform of a transversely heated graphite tube, were investigated for their suitability as permanent chemical modifiers for the determination of cadmium in coal slurries by electrothermal atomic absorption spectrometry (ET AAS). The conventional mixed palladium and magnesium nitrates (Pd–Mg) modifiers, added in solution, were also investigated for comparison. The latter one showed the best performance for aqueous solutions, and the mixed W–Ir and W–Ru permanent modifiers had the lowest stabilizing power. All of the investigated modifiers lost some of their stabilizing power when coal slurries were investigated. The Pd–Mg modifier, pure Ir and Ru, and a mixture of 300 μg W + 200 μg Ir could stabilize Cd at least to a pyrolysis temperature of 600 °C, whereas all the other combinations already failed at temperatures above 500–550 °C. Additional investigations of the supernatant liquid of the slurries supported the assumption that the high acid concentration of the slurries and/or a concomitant leaching out of the coal might be responsible for the reduced stabilizing power of the modifiers. The maximum applicable pyrolysis temperature of 600 °C was not sufficient to reduce the background absorption to a manageable level in the majority of the coal samples. High-resolution continuum source ET AAS revealed that the continuous background absorption was exceeding values of A = 2, and was overlapping with the analyte signal. Although the latter technique could correct for this background absorption, some analyte was apparently lost with the rapidly vaporizing matrix so that the method could not be considered to be rugged. A characteristic mass of 1.0 pg and a detection limit of 0.6 ng g− 1 could be obtained under these conditions.  相似文献   

3.
Cadmium concentration in lake sediments is determined by suspending the solid samples in a solution containing 5% (v/v) concentrated nitric acid and 0.1% (v/v) Triton X-100. Three modifiers were tested for the direct determination. The furnace temperature programmes and appropriate amount for each modifier were optimised to get the highest signal and the best separation between the atomic and background signals. The drying stage is performed by programming a 400 °C temperature, a ramp time of 25 s and hold time of 10 s on the power supply of the atomiser. No ashing step is used and platform atomisation is carried out at 2200 °C. W–Rh permanent modifier combined with conventional modifier by delivering 10 μl of 0.50% (w/v) NH4H2PO4 solution was the best chemical modifier for cadmium determination. This modifier also acts as a liquid medium for the slurry, thus simplifying the procedure. Calibration is performed using aqueous standards in the 1–5 μg l−1 range. The optimised method gave a limit of detection of 0.56 ng ml−1, characteristic mass of 10.1±0.8 pg for aqueous standard, 9.6±0.7 pg for slurry samples containing different Cd concentrations and good precision (7.6–5.2%). The method was validated by analysing four certified reference lake sediment materials: LKSD-1, LKSD-2, LKSD-3 and LKSD-4; satisfactory recoveries were obtained (90.0–96.3%) and no statistical differences were observed between the experimental and the certified cadmium concentration. The developed methodology was used to determine cadmium in three ‘real’ sediment samples from lakes in the area of Wielkopolski National Park, Poland.  相似文献   

4.
A solid sampling electrothermal atomic absorption spectrometry method for direct determination of trace silicon in biological materials was developed and applied to analysis of pork liver, bovine liver SRM 1577b and pure cellulose. The organic matrix was destroyed and expelled from the furnace in the pyrolysis stage involving a step-wise increasing the temperature from 160 °C to 1200 °C. The mixed Pd/Mg(NO3)2 modifier has proved to be the optimum one with respect to the achievement of maximum sensitivity, elimination of the effect of the remaining inorganic substances and the possibility of using calibration curves measured with aqueous standard solutions for quantification. For the maximum applicable sample amount of 6 mg, the limit of detection was found to be 30 ng g− 1. The results were compared with those obtained by different spectrometric methods involving sample digestion, by electrothermal atomic absorption spectrometry using slurry sampling, by wavelength dispersive X-ray fluorescence spectrometry and by radiochemical neutron activation analysis. The method seems to be a promising one for analysis of biological materials containing no significant fraction of silicon in form of not naturally occurring volatile organosilicon compounds. The still incessant serious limitations and uncertainties in the determination of trace silicon in solid biological materials are discussed.  相似文献   

5.
A slurry sampling method has been developed for the determination of Pb in marine plankton by ETAAS using a freshwater plankton certified reference material (CRM 414). Slurries were prepared in 1–3% m/v range with 1% v/v HNO3 by ultrasonic agitation for 5 min. The effects of several chemical modifiers, including Ir(NO3)2, Mg(NO3)2, Pd(NO3)2, Pd(NO3)2 + Mg(NO3)2, and Mg(NO3)2 + NH4H2PO4, were investigated for the stabilization of Pb during thermal pretreatment. Lead in slurries was effectively stabilized up to 1000 °C with Ir, Pd and Pd + Mg modifiers among which Pd + Mg provided the best results with complete atomization at 1850 °C. Firings in the presence of Ir were, problematic due to ash formation inside the atomizer. Water, dilute HNO3 and HF were examined as suspension medium. Dilute HNO3 (1–2% v/v) proved to be advantageous over water as it afforded extraction of Pb from plankton almost quantitatively in 5 min agitation. Hydrofluoric acid was the least suitable medium. Increasing HF concentration up to 5% v/v resulted in inaccuracy and substantial background absorption. Fast-heating furnace method provided comparable accuracy and precision to that of conventional-heating in slurries of CRM 414. Detection limits and characteristic masses were, respectively, 0.49 μg L− 1 and 32 pg for the conventional method and 0.62 μg L− 1 and 37 pg for the fast-heating method. However, fast-heating approach suffered from distorted peaks at high temperatures and incomplete pyrolysis of matrix at lower temperatures. Analysis of marine plankton samples for Pb was performed by using the conventional furnace program. The results showed a high correlation with those obtained by solution ICP-MS. Differences were statistically insignificant within 95% confidence interval.  相似文献   

6.
Slurry sampling atomic absorption spectrometry with electrothermal atomization was used to the determination of cadmium (Cd) and lead (Pb) in soils and sediments using permanent modifiers. Comparison of action of mixed permanent modifiers niobium (Nb)/iridium (Ir) and tungsten (W)/iridium (Ir) were studied in detail. The effect of amount of Ir, W and Nb on analytical signals of Cd and Pb was examined. The optimal amounts of modifiers for Cd and Pb determination were stated. Niobium carbide formation on graphite surface was studied for different pyrolysis temperatures. Finally for Cd determination in sediments and soils 200 μg of Nb mixed with 5 μg of Ir was used as permanent modifiers and 15 μg of Nb mixed with 200 μg of Ir for Pb determination. Suspensions were prepared in 5% HNO3. The analytical procedure was optimized carefully basing on data from pyrolysis and atomization curves studies. Ammonium dihydrogen phosphate was used additionally as matrix modifier during Cd determination in samples in order to prevent interferences coming from matrix components. The analysis of CRMs confirmed the reliability of the proposed approach. The precision and accuracy of Cd and Pb determination by the described method for soils and sediments were acceptable.  相似文献   

7.
This work describes the method development for the simultaneous determination of Cd and Fe using the main resonance line of Cd at 228.802 nm and a secondary Fe line at 228.725 nm, and high-resolution continuum source electrothermal atomic absorption spectrometry (HR-CS ET AAS). Two certified reference materials and two ‘real’ samples of industrial and domestic sewage sludge have been analyzed as slurries prepared in a mixture of HF and HNO3. The simultaneous determination has been performed using a short temperature program of only 30 s, without a pyrolysis stage and with two atomization stages, at 1300 °C and 2300 °C, taking into consideration the significantly different thermal characteristics of Cd and Fe. Structured background, which is likely due to the presence of one or more diatomic molecules, including SiO, has been detected. However, there has been no spectral overlap between molecular bands and the atomic lines of Cd and Fe, making possible the determination to be carried out using only automatic correction for continuous background. Calibration against aqueous standards lead to good agreement between certified or informed values and the determined values, at a statistical confidence level of 95%; recovery tests were performed for real samples, resulting in recoveries ranging from 90 to 105%. Detection limits of 0.03 and 90 µg g 1 for Cd and Fe, respectively, have been obtained, which are adequate for the purpose.  相似文献   

8.
A procedure for the direct determination of Cu, Fe and V in petroleum samples by electrothermal atomic absorption spectrometry using a solid sampling accessory, without any sample pre-treatment or dilution, is proposed. A Pd + Triton X-100 solution was used as chemical modifier. The pyrolysis and atomization temperatures, as well as the Pd mass were defined by multivariate optimization. The other parameters of the temperature programs were defined by univariate optimization. The limits of detection at the optimized conditions were 10, 200 and 800 pg for Cu, Fe and V, respectively, for typical sample masses ranging from 0.10 to 3.00 mg. Method accuracy was confirmed by the analysis of oil certified reference materials as well as by comparison with independent methods. Aqueous calibration solutions were used and no statistically significant difference (analysis of variance) was observed between obtained and expected values.  相似文献   

9.
The determination of cadmium (Cd) in fertilizers is of major interest, as this element can cause growth problems in plants, and also affect animals and humans. High-resolution continuum source graphite furnace atomic absorption spectrometry (HR-CS GF AAS) with charge-coupled device (CCD) array detection overcomes several of the limitations encountered with conventional line source AAS, especially the problem of accurate background measurement and correction. In this work an analytical method has been developed to determine Cd in fertilizer samples by HR-CS GF AAS using slurry sampling. Both a mixture of 10 μg Pd + 6 μg Mg in solution and 400 μg of iridium as permanent modifier have been investigated and aqueous standards were used for calibration. Pyrolysis and atomization temperatures were 600 °C and 1600 °C for the Pd-Mg modifier, and 500 °C and 1600 °C for Ir, respectively. The results obtained for Cd in the certified reference material NIST SRM 695 (Trace Elements in Multi-Nutrient Fertilizer) of 16.7 ± 1.3 μg g−1 and 16.4 ± 0.75 μg g−1 for the Pd-Mg and Ir modifier, respectively, were statistically not different from the certified value of 16.9 ± 0.2 μg g−1 on a 95% confidence level; however, the results obtained with the Ir modifier were significantly lower than those for the Pd-Mg modifier for most of the samples. The characteristic mass was 1.0 pg for the Pd-Mg modifier and 1.1 pg Cd for the Ir modifier, and the correlation coefficients (R2) of the calibration were > 0.99. The instrumental limits of detection were 7.5 and 7.9 ng g−1, and the limits of quantification were 25 and 27 ng g−1 for Pd-Mg and Ir, respectively, based on a sample mass of 5 mg. The cadmium concentration in the investigated samples was between 0.07 and 5.5 μg g−1 Cd, and hence below the maximum value of 20 μg g−1 Cd permitted by Brazilian legislation.  相似文献   

10.
Coşkun N  Akman S 《Talanta》2004,64(2):496-500
Manganese in vitamin-minerals tablets was determined by solid sampling electrothermal atomic absorption spectrometry (SS-ETAAS) using three different calibration methods, namely calibration against aqueous standards, standard addition with aqueous standards on solid samples and calibration against solid certified standards. Samples were only finely ground and introduced directly into the furnace by means of solid autosampler system without any dissolving process. Effects of different calibration techniques, temperatures and heating rates of atomization and pyrolysis steps on the accuracy and precision of the analyte elements were investigated. After optimization of the experimental parameters, there is good agreement (at 95% confidence level) between the results obtained by solid sampling and those obtained by acid digestion of samples.  相似文献   

11.
The comparative determination of lead in plant samples by two atomic spectrometric techniques is reported. At first, slurry sampling electrothermal atomisation atomic absorption spectrometry (ETAAS) was applied. The results obtained were compared with those found after a wet digestion procedure by flame atomic absorption spectrometry (FAAS) or ETAAS. The accuracy of the studied methods was checked using a certified reference material (CL???1 CRM, Cabbage Leaves). The recovery of lead was 90% for slurry sampling ETAAS, and 86.6% for liquid sampling ETAAS. The advantages of the slurry sampling ETAAS method are the simplicity of sample preparation and very good sensitivity.  相似文献   

12.
In this work, the capabilities and limitations of solid sampling techniques – laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS), wavelength dispersive X-ray fluorescence spectrometry (WD-XRFS) and solid sampling electrothermal atomic absorption spectrometry (SS-ETAAS) – for the determination of silver in polymers have been evaluated and compared to those of acid digestion and subsequent Ag determination using pneumatic nebulization ICPMS (PN-ICPMS) or flame AAS (FAAS).  相似文献   

13.
A direct solid sampling electrothermal atomic absorption spectrometric method for determination of Cd, Co, Cr, Cu, Fe, Li, Mn, Ni and Zn in zirconium dioxide has been developed. Using optimised experimental conditions, very effective in-situ analyte/matrix separation was achieved without any chemical modification. After the measurement, the matrix residue could easily be tipped out from the platform. In the determination of Cr, before sampling, the platform bottom was covered with carbon powder. Quantification was performed using calibration curves measured with aqueous standard solutions pipetted onto the matrix residue from a previous sample run. Sample amounts between 0.5 and 40 mg were applied for each analysis cycle. The accuracy was determined by comparison of the results with those obtained by radiochemical neutron activation analysis and by electrothermal atomic absorption spectrometry using liquid sampling of digests and slurry sampling. For the nine elements assayed, the limits of detection achievable by this method are between 0.06 ng g–1 (Cd) and 2.3 ng g–1 (Fe).Dedicated to the memory of Wilhelm Fresenius  相似文献   

14.
Methods for the determination of aluminium and manganese in human scalp hair samples by electrothermal atomic absorption spectrometry using the slurry sampling technique were developed. Palladium and magnesium nitrate were used as chemical modifiers. Hair samples were pulverized using a zirconia vibrational mill ball, and were prepared as aqueous slurries. Determinations can be performed in the linear ranges of 1.9–150 μg l−1 Al3+ and 0.03–10.0 μg l−1 Mn2+. Limits of detection of 0.9 mg kg−1 and 27.6 μg kg−1 were obtained for aluminium and manganese, respectively. The analytical recoveries were between 99.6 and 101.8% for aluminium and in the 98.3–101.3% range for manganese. The repeatability of the methods (n=11), slurry preparation procedure and ETAAS measurement, was 16.0 and 7.9% for aluminium and manganese, respectively. The methods were finally applied to the aluminium and manganese determination in 25 scalp hair samples from healthy adults. The levels for aluminium were between 8.21 and 74.08 mg kg−1, while concentrations between 0.03 and 1.20 mg kg−1 were found for manganese.  相似文献   

15.
A rapid and practical solid sampling electrothermal atomic absorption spectrometric method was described for the determination of lead in scalp hair. Hair samples were washed once with acetone; thrice with distilled-deionized water and again once with acetone and dried at 75 °C. Typically 0.05 to 1.0 mg of dried samples were inserted on the platforms of solid sampling autosampler. The effects of pyrolysis temperature, atomization temperature, the amount of sample as well as addition of a modifier (Pd/Mg) and/or auxiliary digesting agents (hydrogen peroxide and nitric acid) and/or a surfactant (Triton X-100) on the recovery of lead were investigated. Hair samples were washed once with acetone; thrice with distilled-deionized water and again once with acetone and dried at 75 °C. Typically 0.05 to 1.0 mg of dried samples were inserted on the platforms of solid sampling autosampler. The limit of detection for lead (3σ, N = 10) was 0.3 ng/g The addition of modifier, acids, oxidant and surfactant hardly improved the results. Due to the risk of contamination and relatively high blank values, the lead in hair were determined directly without adding any reagent(s). Finally, the method was applied for the segmental determination of lead concentrations in hair of different persons which is important to know when and how much a person was exposed to the analyte. For this purpose, 0.5 cm of pieces were cut along the one or a few close strands and analyzed by solid sampling.  相似文献   

16.
Ultrasonic slurry sampling electrothermal atomic absorption spectrometry with a molybdenum tube atomizer has been applied for the determination of cadmium in vegetable samples in Bangladesh. The suspension-stabilizing medium was 10% glycerol solution. The optimum pyrolysis temperature was 300°C. The detection limit was 13?fg (3S/N). Matrix element interference was studied and it was found that thiourea as a chemical modifier eliminated the interference. The results for the determination of cadmium in vegetable samples by the proposed method were in good agreement with those measured in dissolved acid-digested samples. The method enables rapid calibration, and simple and rapid analysis of cadmium in vegetable samples at low cost.  相似文献   

17.
A procedure for chromium (Cr) determination in pharmaceutical grade barium sulfate by direct solid sampling electrothermal atomic absorption spectrometry (DSS-ET AAS) with Zeeman-effect background correction was developed. Operational conditions for the proposed procedure and the use of citric acid, ammonium phosphate, palladium and magnesium nitrate as chemical modifiers were evaluated. Pyrolysis and atomization temperatures were set at 1500 and 2400 °C, respectively and the use of matrix modifiers did not improve these conditions. Graphite platform presented high degradation rate, but minima changes were observed in the sensitivity or signal profile. Samples (0.3-1 mg) were weighted and introduced into the furnace using a manual solid sampling system. The linear concentration range of the calibration curve was from 100 to 1800 pg (R2 > 0.995). The characteristic mass was 7.7 pg and the limit of detection was 2.4 pg. Chromium concentration in commercial samples ranged from 0.45 to 1.06 μg g−1 and these results were confirmed by standard addition method. The mean reproducibility was 12% (n = 20 in a 3-day period) and repeatability was less than 9%. Results obtained using inductively coupled plasma optical emission spectrometry and conventional electrothermal atomic absorption spectrometry after extraction with HNO3 were around 20% lower than those obtained by the proposed procedure. It was assumed that the low results were due to incomplete extraction even using hard conditions related to temperature and pressure. The proposed procedure by DSS-ET AAS provided some advantages related to recommended pharmacopoeias methodology, as lower risks of contamination and analyte losses, higher specificity, accuracy and sensitivity, no toxic or unstable reagents are required, and calibration with aqueous standards was feasible.  相似文献   

18.
This work describes an analytical procedure for vanadium determination in human hair slurries by electrothermal AAS using longitudinal heating (LHGA) and transversal heating (THGA) graphite furnace atomizers. The samples were powdered using cryogenic grinding and the hair slurries containing 0.2% (m/v) were prepared in three different media for determination of vanadium: 0.14 mol L−1 HNO3, 0.1% (v/v) Triton X-100 and 0.1% (v/v) water soluble tertiary amines (CFA-C, pH 8). The limits of detection (LOD), limits of quantification (LOQ), and characteristic masses obtained were 0.28, 0.95 μg L−1 and 35 pg (LHGA) and 0.34, 1.13 μg L−1 and 78 pg (THGA), respectively. The accuracy of the analytical results obtained by the proposed procedure in both equipments was confirmed by a paired t-test at the 95% confidence level and compared with a conventional procedure based on acid digestion.  相似文献   

19.
《Analytica chimica acta》2004,522(2):259-266
A new procedure for Co determination in a complex matrix (coal fly ash) by slurry extraction-electrothermal atomic absorption spectrometry (ETAAS) is presented. Fractional experimental designs were applied to find the most important variables affecting Co extraction. Two liquid media (HCl + HNO3 and HF) and three agitation modes (ultrasonic probe, ultrasonic bath and manual shaking) were assayed. HF revealed as the most suitable medium for Co extraction, being its concentration and time of contact the most significant variables. Quantitative extraction was obtained after their optimisation (16%, v/v HF; 5 min), with good accuracy (coal fly ash SRM 1633a and SRM 1633b) and precision (R.S.D. < 11.5%). The limit of detection of the method was 0.02 μg g−1 (100 mg mL−1 slurry), and the characteristic mass was 15 ± 1 pg. The ‘slurry-extraction procedure’ established is simple, fast, cheap and was also validated for soil and sediment analysis. As far as we know, a slurry-extraction procedure has not yet been applied to quantify cobalt by ETAAS in such matrices. Moreover, nine coal fly ashes, 12 sediments and 18 soils were analysed by the proposed method and also by a direct slurry sampling-ETAAS procedure in order to compare their performance. In general, the HF-extraction slurry procedure revealed superior.  相似文献   

20.
Slurry sampling is compared to microwave-assisted acid digestion for cobalt determination in soil/sediment samples by electrothermal atomic absorption spectrometry (ETAAS). Furnace temperature programs and appropriate amounts of three chemical modifiers were optimised in order to get the highest signals and good separations between the atomic and background signals. Using nitric acid (0.5% (v/v)) as liquid medium, no chemical modifier was needed. The detection limit, based on integrated absorbance, was 0.04 μg g−1 for digests and slurries. Within-batch precision and analytical recoveries were satisfactory for both procedures. Accuracy was tested by analysing a reference soil and a sediment from IRMM. The methods were further compared employing a set of roadside soils and estuarine sediments. As no significant differences (95% confidence) were found, practical analytical properties were suggested in order to select one of them.  相似文献   