首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Chemiluminescent evaluation of peroxide value in olive oil   总被引:1,自引:0,他引:1  
A method is described for the evaluation of the peroxide value (PV, meq. O2 kg−1) in olive oil. The method is based on the chemiluminogenic energy-transfer reaction of bis(2,4,6-(trichlorophenyl)oxalate (TCPO) with hydrogen peroxide or total peroxides in the presence of Mn(II) as catalyst and 9,10-dimethylanthracene as fluorophore. The procedure developed allows the evaluation of PV within the range of 0.6-100 meq. O2 kg−1 (CL intensity = 1.76 × PV (meq. O2 kg−1) + 23.2, r2 = 0.994, n = 9) and relative standard deviation within the range 1-5% by using a simple manual measurement.  相似文献   

2.
This work reports a novel flow injection (FI) method for the determination of captopril, 1-[(2S)-3-mercapto-2-methylpropionyl]-l-proline (CPL), based on the enhancement CPL affords on the chemiluminescence (CL) reaction between luminol and hydrogen peroxide. For this purpose alkaline luminol and hydrogen peroxide solutions were mixed online, the sample containing CPL was injected into an aqueous carrier stream, mixed with the luminol-hydrogen peroxide stream and pumped into a glass flow cell positioned in front of a photomultiplier tube (PMT). The increase in the CL intensity was recorded in the form of FI peaks, the height of which was related to the CPL mass concentration in the sample. Different chemical and instrumental parameters affecting the CL response were investigated. Under the selected conditions, the log-log calibration curve was linear in the range 5-5000 μg l−1 of CPL, the limit of detection was 2 μg l−1 (at the 3σ level), the R.S.D., sr was 3.1% at the 100 μg l−1 level (n=8) and the sampling rate was 180 injections h−1. The method was applied to the determination of CPL in pharmaceutical formulations with recoveries in the range 100±3%.  相似文献   

3.
In this work, a straightforward, reliable and effective automated method has been developed for the direct determination of monoaromatic volatile BTEXS group (namely benzene, toluene, ethylbenzene, o-, m- and p-xylenes, and styrene) in olives and olive oil, based on headspace technique. Separation, identification and quantitation were carried out by headspace-gas chromatography-mass spectrometry (HS-GC-MS) in selected ion monitoring (SIM) mode. Sample pretreatment or clean-up were not necessary (besides olives milling) because the olives and olive oil samples are put directly into an HS vial, automatically processed by HS and then injected in the GC-MS for chromatographic analysis. The chemical and instrumental variables were optimized using spiked olives and olive oil samples at 50 μg kg−1 of each targeted species. The method was validated to ensure the quality of the results. The precision was satisfactory with relative standard deviations (RSD (%)) in the range 1.6-5.2% and 10.3-14.2% for olive oil and olives, respectively. Limits of detection were in the range 0.1-7.4 and 0.4-4.4 μg kg−1 for olive oil and olives, respectively. Finally, the proposed method was applied to the analysis of real olives and olive oil samples, finding positives of the studied compounds, with overall BTEXS concentration levels in the range 23-332 μg kg−1 and 4.2-87 μg kg−1 for olive oil and olives, respectively.  相似文献   

4.
A flow-injection method for measuring the peroxide value (PV, mequiv. O2 kg−1) in edible oils is described. The technique is based on spectrophotometric monitoring at 660 nm of methylene blue (MB), generated from leucomethylene blue (LMB) oxidation with peroxides present in oil samples. After being optimized, the method was validated in terms of linearity, precision sensitivity and recovery.Linear calibration graph was obtained in the range 0.1-5 mequiv. O2 kg−1, with a detection limit (S/N  =  3) of 0.014 mequiv. O2 kg−1. The precision of the method (R.S.D., n = 9) for within and between-days is better than 1.5% and 2.2%, respectively at 0.4 mequiv. O2 kg−1. The method was applied successfully to the determination of PV in six edible oil samples, and compared to the classical official method. Using the linear regression test, Student's t-test and variance ratio F-test, there was no significant difference between the compared methods. The proposed method is accurate, simple, cheap and could be used to control edible oil rancidity with a high sample throughputs (30 samples h−1).  相似文献   

5.
A simple flow-based procedure with chemiluminescence (CL) detection is proposed for bromide ion determination in seawater. The procedure was based on the oxidation of bromide to bromine by chloramine-T followed by the reaction of bromine with luminol resulting in CL emission. Since no significant reaction within chloramine-T and luminol was observed, the detection was carried out without bromine extraction from the oxidant medium. The proposed flow system had a sampling rate of 40 determinations per hour, reagents consumption of 100 μg luminol and 60 μg chloramine-T per determination, a limit of detection of 0.5 mg l−1 bromide ions, a linear concentration range (r = 0.999 and n = 7) between 0 and 100 mg l−1, and a coefficient of variance better than 2.5% (for 10 measurements of a 10 mg l−1 Br solution) were achieved. The analytical system was applied for the determination of bromide in seawater and estuarine-water samples, obtaining an analyte recovery ranging from 94 to 102% and comparing the results with a reference spectrophotometric method no significant difference was observed in 95% confidence level.  相似文献   

6.
This work reports a sequential-injection analysis (SIA) method for the enzymatic assay of glucose with soluble glucose oxidase (GOD) and on-line sample dilution with chemiluminescence (CL) detection. A zone of sample was aspirated in the holding coil of the SIA manifold and, if necessary, was diluted on-line by means of an auxiliary dilution conduit. Then, a zone of GOD was aspirated adjacent to the sample zone and a stopped-flow period was applied to allow the enzymatic reaction to proceed with production of hydrogen peroxide. Then, zones of a catalyst (Co(II) solution) and alkaline luminol were aspirated into the holding coil. Finally, the flow was reversed and the stacked zones were sent to a flow-cell located in front of a photomultiplier tube (PMT) that monitored the CL intensity. The linear dynamic range was 1 × 10−5-1 × 10−3 mol L−1 glucose, the coefficient of variation at 8 × 10−5 mol L−1 of glucose was sr = 3.1% (n = 8), the limit of detection at the 3σ level was cL = 1 × 10−6 mol L−1 and the sampling frequency was 28 h−1. With on-line dilution by a factor of 1/200, the linear range could be extended up to 0.2 mol L−1 glucose. The advantages of the proposed method are the simple manifold and instrumentation used, the scope for automated on-line dilution, the low consumption of sample and reagents and the elimination of enzyme immobilisation procedures. The method was applied to the analysis of commercial drinks and honey with percent relative errors in glucose determination in the range 100 ± 6.1%.  相似文献   

7.
A rapid and simple method using capillary electrophoresis (CE) with chemiluminescence (CL) detection was developed for the determination of levodopa. This method was based on enhance effect of levodopa on the CL reaction between luminol and potassium hexacyanoferrate(III) (K3[Fe(CN)6]) in alkaline aqueous solution. CL detection employed a lab-built reaction flow cell and a photon counter. The optimized conditions for the CL detection were 1.0 × 10−5 M luminol added to the CE running buffer and 5.0 × 10−5 M K3[Fe(CN)6] in 0.6 M NaOH solution introduced postcolumn. Under the optimal conditions, a linear range from 5.0 × 10−8 to 2.5 × 10−6 M (r = 9991), and a detection limit of 2.0 × 10−8 M (signal/noise = 3) for levodopa were achieved. The precision (R.S.D.) on peak area (at 5.0 × 10−7 M of levodopa, n = 11) was 4.1%. The applicability of the method for the analysis of pharmaceutical and human plasma samples was examined.  相似文献   

8.
Panoutsou P  Economou A 《Talanta》2005,67(3):603-609
This work reports a hybrid flow-injection analysis (FIA)/sequential-injection analysis (SIA) method for the rapid enzymatic assay of glucose with soluble glucose oxidase (GOD). The method relies on the sequential injection of segments of the sample and of a solution of enzyme by means of a multi-port selection valve in a flowing water stream. As the two zones are swept downstream, they overlap and merge so that the glucose in the sample is enzymatically oxidised. The generated hydrogen peroxide is merged with an alkaline luminol solution and the chemiluminescence (CL) intensity is monitored and related to the glucose concentration in the sample. The linear range of the method for glucose determination is 0.01-1 mmol L−1, the relative standard deviation is 3.9% at the 0.08 mmol L−1 level (n = 8), the limit of detection at the 2σ level is 4 μmol L−1 glucose and the injection rate is 80 h−1. The method was applied to the analysis of energy drinks and honey with relative errors in glucose determination in the range 100 ± 4.3%. The advantages of the proposed method are the wide linear range, the simple instrumentation used, the low consumption of sample and reagents, the elimination of catalysts and immobilised enzymes and the high sample throughput.  相似文献   

9.
A compact, reliable and low cost flow injection chemiluminescence system is described. The flow system consists of a set of solenoid micro-pumps that can dispense reproductive micro-volumes of solutions. The luminometer was based on a coiled cell constructed from polyethylene tubing that was sandwiched between two large area photodiodes. The whole equipment costs about US$ 750 and weights ca. 3 kg. Equipment performance was evaluated by measuring low concentrations of hydrogen peroxide by oxidation of luminol and for the determination of ammonium, based on its inhibition of the luminescence provided by the reaction of luminol and sodium hypochlorite. Linear responses were achieved within 1.0-80 μmol L−1 H2O2 and 0.6-60 μmol L−1 NH4+ with detection limits estimated as 400 nmol L−1 H2O2 and 60 nmol L−1 NH4+ at the 99.7% confidence level. Coefficients of variation were 1.0 and 1.8%, estimated for 20 μmol L−1 H2O2 and 15 μmol L−1 NH4+ (n = 20), respectively. Reagent consumption of 55 μg luminol, effluent volume of 950 μL per determination and sampling rate of 120 samples per hour were also achieved.  相似文献   

10.
Determination of edible oil parameters by near infrared spectrometry   总被引:6,自引:0,他引:6  
A chemometric method has been developed for the determination of acidity and peroxide index in edible oils of different types and origins by using near infrared spectroscopy (NIR) measurements. Different methods for selecting the calibration set, after an hierarchical cluster analysis, were applied. After discrimination of olive oils from maize, seed and sunflower, the prediction capabilities of partial least squares (PLS) multivariate calibration of NIR data were evaluated. Several preprocessing alternatives (first derivative, multiplicative scatter correction, vector normalization, constant offset elimination, mean centering and standard normal variate) were investigated by using the root mean square error of validation (RMSEV) and prediction (RMSEP), as control parameters. Under the best conditions studied, the validation set provides RMSEP values of 0.034 and 0.037% (w/w) for acidity in (I) olive oil group and (II) sunflower, seed and maize oils group. RMSEP values for peroxide in both sample groups, expressed as mequiv. O2 kg−1, were, respectively 1.87 and 0.79. The limit of detection of the methodology developed was 0.03% for acidity in both groups of edible oils (I and II), and 0.9 and 0.8 mequiv. O2 kg−1 for peroxide in the olive oil and other edible oils groups, respectively. In fact, the methodology developed is proposed for direct acidity quantification and for the screening of peroxide index in edible oils, requiring less than 30 s per sample without any previous treatment.  相似文献   

11.
The determination of pKa value for the unstable chromium(VI) peroxide, CrO(O2)2(H2O) in aqueous solution is presented. The pKa value is found to be (1.55 ± 0.03). The kinetic decomposition of chromium(VI) peroxide is dependent on the concentration of hydrogen peroxide in the pH range between 2.5 and 4.0. We have proposed the possible explanation for the formation of triperoxo chromium complex of hydrogen peroxide which is dependent on decomposition. Activation of coordinate peroxide in chromium(VI) peroxide observed in the kinetic studies is by reduction of thiolato-cobalt(III) complex. The rate constant (M−1 s−1, 15 °C) for the oxygen atom transfer reaction from CrO(O2)2(OH) to (en)2Co(SCH2CH2NH2)2+ is found to be (25.0 ± 1.3).  相似文献   

12.
In this paper, a novel electrochemiluminescence (ECL) imaging sensor array was developed for determination of hydrogen peroxide (H2O2), which was based on Cu/Zn alloy galvanic cell generated ECL. In alkaline solution, Cu/Zn galvanic cell was formed because of corrosion effect, the galvanic cell could supply stable potential for ECL generation of luminol, and the weak ECL emission could be enhanced by H2O2. The galvanic cell sensor array was designed by putting Cu/Zn alloy in 96-well microtiter plates separately. The relative ECL intensity was proportional with the concentration of hydrogen peroxide in the range of 1.0 × 10−6 to 1.0 × 10−4 mol l−1 and the detection limit was 3.0 × 10−7 mol l−1 (3σ), the relative standard deviation (R.S.D.) for 11 parallel measurements of 1.0 × 10−5 mol l−1 H2O2 was 4.0%.  相似文献   

13.
An effective extraction method was devised for the determination of organophosphorus pesticides (OPPs) in olive and avocado oil samples, using atmospheric pressure microwave-assisted liquid–liquid extraction (APMAE) and solid-phase extraction or low-temperature precipitation as clean-up step. A simple glass system equipped with an air-cooled condenser was designed as an extraction vessel. The pesticides were partitioned between acetonitrile and oil solution in hexane. Analytical determinations were carried out by gas chromatography-flame photometric detection and gas chromatography–tandem mass spectrometry, using a triple quadrupole mass analyzer, for confirmation purposes. Several factors influencing the extraction efficiency were investigated and optimized through fractional factorial design and Doehlert design. Under optimal conditions the recovery of pesticides from oil at 0.025 μg g−1 ranged from 71% to 103%, except for fenthion in avocado oil, with RSDs ≤13% (n = 5). The LOQ for the entire method ranged from 0.004 to 0.015 μg g−1. Finally, the proposed method was successfully applied to the extraction and determination of the selected pesticides in 20 commercially packed extra virgin olive oils and four commercially packed avocado oils produced in Chile. Detectable residues of different OPPs were observed in 85% of samples.  相似文献   

14.
A chemiluminescence (CL) flow system for determination of thyroxine (Thy) is presented. It is based on the catalytic effect of cobalt(II) on the CL reaction between luminol and hydrogen peroxide. The iodinated chemical structure of Thy causes a heavy atom effect. The luminol CL signals show significant quenching by Thy. The calibration graph for Thy is linear for 15-70 μg ml−1 and the 3σ detection limits are 27 μg ml−1 for d-Thy and 23 μg ml−1 for l-Thy.  相似文献   

15.
A flow injection analysis (FIA) method for the determination of peroxide value (PV) in edible oils is described. Oil sample (undiluted) and KI reagent were aspirated into a homemade reaction chamber where the redox reaction between iodide in the aqueous phase and hydroperoxides in the oil was effected by applying a short (typically 30 s) vortex action. After allowing for the emulsified oil phase to be separated from the aqueous phase (bottom layer), an aliquot of the aqueous phase containing triiodide was next aspirated to the surface of a triiodide-selective membrane for detection. The optimized FIA procedure is linear over 0.35-28.0 PV (mequiv. O2/kg) with a detection limit of 0.32 PV. Exhibiting good reproducibility (R.S.D. of 2.7% (n = 8) for the determination of 1.1 PV) and sampling rate of 80 samples h−1, the proposed method, unlike previous FIA procedures, completely eliminated the use of organic solvents (except the use of 2-propanol for cleaning of reaction chamber). Excellent correlation (R2 = 0.9949) between the proposed method and the manual official AOCS method was found when applied to the determination of PV in diverse type of edible oils (n = 20).  相似文献   

16.
A sensitive and selective flow injection chemiluminescence (CL) method combined with controlled potential electrolysis technique was described for the determination of molybdenum. The method is based on the chemiluminescence reaction of luminol with unstable molybdenum(III) in alkaline solution. The molybdenum(III) was on-line reduced from molybdenum(VI) via controlled potential electrolysis technique using a homemade flow-through carbon electrolytic cell at the potential of −0.6 V (versus Ag/AgCl). The method allows the determination of molybdenum in the 5.0×10−10 to 5.0×10−7 g ml−1 range with a limit of detection (3σ) of 5×10−11 g ml−1 molybdenum. The relative standard deviation is 2.6% for the 1.0×10−9 g ml−1 molybdenum solution in 11 repeated measurements. This method was successfully applied to the determination of molybdenum in water samples.  相似文献   

17.
Amini N  McKelvie I 《Talanta》2005,66(2):445-452
A sensitive and selective flow injection method for the determination of phosphatidylcholine (PC) in sediment pore waters and extracts is described. It involves the use of phospholipase C, alkaline phosphatase and choline oxidase co-immobilized on controlled pore glass in a packed column reactor. The final product of the enzymatic reaction of phosphatidylcholine is hydrogen peroxide, and this is detected by measuring the chemiluminescence emission resulting from cobalt(II) catalysed reaction with luminol. The flow injection method is rapid (30 injections/h), reproducible (1.4% R.S.D. at 3 μM PC, n = 10) with a detection limit of 0.14 μM (estimated from 3σn−1 of the measured blank). A linear calibration response was obtained over a concentration range of 0.5-9 μM (r = 0.999). The method has been applied to the determination of phosphatidylcholine in sediment extracts and sediment pore waters.  相似文献   

18.
A novel, sensitive and high selective flow-injection chemiluminescence (FI-CL) method for the determination of phenol is reported, based upon its decreasing effect on the CL reaction of luminol with hydrogen peroxide catalyzed by manganese (III) deuteroporphyrin [MnDP, Scheme 1, 3] in alkaline solution. Under the selected optimized experimental conditions, the relative CL intensity was linear with phenol in the range of 4.0 × 10−9 to 4.0 × 10−7 g mL−1. The detection limit (3σ) was 6.3 × 10−10 g mL−1 and the relative standard deviation for 1.0 × 10−7 g mL−1 phenol (n = 11) was 2.99%. The regression equation was I = 120.79 + 1.14 × 1010c (R = 0.9936). This method has been applied to the determination of phenol in water with satisfactory results.  相似文献   

19.
Indirect detection of paracetamol was accomplished using a capillary electrophoresis-chemiluminescence (CE-CL) detection system, which was based on its inhibitory effect on a luminol-potassium hexacyanoferrate(III) (K3[Fe(CN)6]) CL reaction. Paracetamol migrated in the separation capillary, where it mixed with luminol included in the running buffer. The separation capillary outlet was inserted into the reaction capillary to reach the detection window. A four-way plexiglass joint held the separation capillary and the reaction capillary in place. K3[Fe(CN)6] solution was siphoned into a tee and flowed down to the detection window. CL was observed at the tip of the separation capillary outlet. The CL reaction of K3[Fe(CN)6] oxidized luminol was employed to provide the high and constant background. Since paracetamol inhibits the CL reaction, an inverted paracetamol peak can be detected, and the degree of CL suppression is proportional to the paracetamol concentration. Maximum CL signal was observed with an electrophoretic buffer of 30 mM sodium borate (pH 9.4) containing 0.5 mM luminol and an oxidizer solution of 0.8 mM K3[Fe(CN)6] in 100 mM NaOH solution. Under the optimal conditions, a linear range from 6.6 × 10−10 to 6.6 × 10−8 M (r = 0.9999), and a detection limit of 5.6 × 10−10 M (signal-to-noise ratio = 3) for paracetamol were achieved. The relative standard deviation (R.S.D.) of the peak area for 5.0 × 10−9 M of paracetamol (n = 11) was 2.9%. The applicability of the method for the analysis of pharmaceutical and biological samples was examined.  相似文献   

20.
β−cyclodextrins (β−CD)-based inclusion complexes of CoFe2O4 magnetic nanoparticles (MNPs) were prepared and used as catalysts for chemiluminescence (CL) system using the luminol-hydrogen peroxide CL reaction as a model. The as-prepared inclusion complexes were characterized by XRD (X-ray diffraction), TGA (thermal gravimetric analysis) and FT-IR. The oxidation reaction between luminol and hydrogen peroxide in basic media initiated CL. The effect of β−CD-based inclusion complexes of CoFe2O4 magnetic nanoparticles and naked CoFe2O4 magnetic nanoparticles on the luminol-hydrogen peroxide CL system was investigated. It was found that inclusion complexes between β−CD and CoFe2O4 magnetic nanoparticles could greatly enhance the CL of the luminol-hydrogen peroxide system. Investigation on the kinetic curves and the chemiluminescence spectra of the luminol-hydrogen peroxide system demonstrates that addition of CoFe2O4 MNPs or inclusion complexes between β−CD and CoFe2O4 MNPs does not produce a new luminophor of the chemiluminescent reaction. The luminophor for the CL system was still the excited-state 3-aminophthalate anions (3-APA*). The enhanced CL signals were thus ascribed to the possible catalysis from CoFe2O4 MNPs or inclusion complexes between β−CD and CoFe2O4 nanoparticles. The feasibility of employing the proposed system for hydrogen peroxide sensing was also investigated. Experimental results showed that the CL emission intensity was linear with hydrogen peroxide concentration in the range of 1.0 × 10−7 to 4.0 × 10−6 mol L−1 with a detection limit of 2.0 × 10−8 mol L−1 under optimized conditions. The proposed method has been used to determine hydrogen peroxide in water samples successfully.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏