首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A method to determine low levels of iodine species namely I and IO3 in aqueous samples was developed and applied to milk and milk powder samples. It is based on selective preconcentration of I in polymer inclusion sorbent (PIS) and neutron activation analysis (NAA) of I sorbed in PIS. The PIS was found to be highly selective for I in presence of IO3 and other anions commonly present in the milk samples. In order to preconcentrate total I + IO3 content in the PIS, IO3 was reduced to I using a mixture of acetic acid and ascorbic acid. It was found that total iodine content in milk could be determined with epithermal neutron activation analysis (ENAA). A scheme was developed to determine I, IO3 and total iodine. The developed method was applied to milk reference materials (NIST SRM-1549 and IAEA-RM-153 milk powder) and a commercially available milk powder. The scheme for estimation of iodine in different forms was validated by using reference material NIST SRM-1549.  相似文献   

2.
The measurement uncertainty of iodine determination in NIST standard reference material (SRM) 1549 using radiochemical neutron activation analysis (RNAA) was studied. This method is based on ignition of the irradiated sample [127I(n,)128I, t1/2=25 min, E=422.9 keV] in an oxygen atmosphere, followed by absorption of iodine in a reducing acid solution and its purification by a selective extraction–stripping–reextraction cycle. The purified solution of iodine in CHCl3 was transferred to a well-type HPGe detector for -ray measurement of the induced radionuclide 128I. The detection limit of the method employed under the conditions described was 1 ng/g. The reproducibility of iodine determination in the SRM was 3.6% (12 determinations within 1 month), calculated by the analysis of variance procedure. Using the commercially available software program GUM Workbench and the recommendations of the Eurachem/CITAC Guide, we evaluated the uncertainty budget for this RNAA method and the relative uncertainty obtained was 3.6%. The largest uncertainty contributions were due to the repeatability of the chemical yield determination, the count rate of the induced nuclide in the standard and sample, the mass of the carrier and the mass of the irradiation standard.  相似文献   

3.
Despite the role of iodine for proper development of the brain and the functions of the element, the accurate data on its concentration in brain tissue are largely lacking, the main reason being analytical difficulties associated with determination of the element especially at low levels. In this work, samples from human brain regions from Hungarian patients were analyzed using epithermal and radiochemical neutron activation analysis (ENAA and RNAA, respectively). The RNAA procedure is based on alkaline-oxidative fusion followed by extraction of elemental iodine in chloroform. The results were checked by the analysis of biological standard reference materials, namely bovine liver, bone meal and diet, and by comparison with previous results obtained by a different RNAA procedure.  相似文献   

4.
Milk is known to contain organohalogen compounds. A mixture of hexane and isopropanol was used to extract lipids from bovine milk and neutron activation analysis (NAA) was employed to measure extractable organohalogens in the lipids. The samples were irradiated in a neutron flux of 2.5 × 1011 cm2 s?1 for 10 min, allowed to decay for 2 min, and counted for 10 min. Uncertainties associated with the preconcentration NAA measurements were investigated in detail. The mass fractions of halogens in mg kg?1 and their relative expanded uncertainties in percent in bovine milk lipids were: 32 (8.4 %), 2.65 (9.8 %) and 0.211 (6.6 %) for Cl, Br and I, respectively.  相似文献   

5.
优化了影响新型活性炭纤维衍生化固相微萃取(ACF-SPME)效率的萃取时间、萃取温度、解析时间、解析温度以及离子强度等主要条件。碘的检出限为0.1μg/L,线性范围为1~500μg/L,相对标准偏差(RSD%)为6.9%。方法用于牛奶样品分析,样品的加标回收率为86%。活性炭纤维与商用纤维相比,具有吸附量大,成本低,使用寿命长和耐高温等优点,是一种有发展前景的固相微萃取纤维。  相似文献   

6.
M.C. Yebra  M.H. Bollaín 《Talanta》2010,82(2):828-36
A simple, precise and accurate automatic method for the determination of total iodine in milk products by indirect atomic absorption spectrometry is proposed. Iodide in solutions resulting from alkaline ashing of samples is precipitated with silver ion in a precipitation-dissolution flow manifold, which allows performing on-line the retention of the silver iodide precipitate formed on a filter, its wash with diluted ammonia and its dissolution with a diluted thiosulfate solution. Dissolved silver is also determined on-line by flame atomic absorption, and the achieved amount of this metal is proportional to that of iodine in the sample. The proposed method is very selective, avoids interferences from anions present in the samples, which can be also precipitated with silver, because these silver compounds are dissolved with ammonia at the washing step. This method allows the determination of iodine in the range 0.011-0.35 μg mL−1 with a relative standard deviation between 1.3 and 6.8% at a rate of ca. 17 samples h−1.  相似文献   

7.
The biologically essential trace element, iodine, has been determined in various milk products by epithermal neutron activation analysis /ENAA/ after sealing in quartz and irradiating under cadmium cover. The method was extended to several IAEA and NBS biological reference materials.  相似文献   

8.
A method of determination of iodine (total and PBI) in serum, urine and other biological materials has been developed. The method consists in a gamma-spectrometric measurement of128I activity after its radiochemical separation. The radiochemical separation procedure includes wet decomposition of the samples in a nitric acid medium followed by a few separation steps, the essential step being the substoichiometric extraction of iodide with a chloroform solution of tetraphenylarsonium chloride. Owing to the application of the substoichiometric separation, a high radiochemical purity of the separated iodine is achieved and the determination of the yield of radiochemical separation is not necessary.  相似文献   

9.
A global radionuclide monitoring system is being engineered as part of a multi-technology verification system for the Comprehensive Nuclear Test Ban Treaty. The system detects airborne radioactive aerosols and gases that can indicate nuclear weapons test debris. The backbone of the system is a network of 80 remote detection stations that utilize high-volume air sampling and high-resolution gamma spectrometry to provide in-situ assay and near-real time reporting. These stations are linked to the International Data Centre, which is a central data processing hub where raw spectral data is automatically processed, analyzed, and disseminated to the states parties. Measurements are categorized based on spectral content to determine which contain anomalous anthropogenic radionuclides that require intensive radiochemical analysis at a certified laboratory. The resulting system has the capability to measure microbecquerel concentrations of radionuclides and provide accessible data products within minutes of field measurements. During the past year of international operations, the minimum detectable concentrations and spectroscopy processing statistics were recorded as a function of geographical location and time. The results show that this system is an effective tool for nuclear test monitoring, as well as other applications such as radiological emergency response, public health monitoring, and scientific research.  相似文献   

10.
Chemical separation methods in conjunction with instrumental neutron activation analysis (INAA) were developed for measuring iodine levels in commercially available bovine milk with varying milk fat (MF) content. Samples of homogenized (3.25 % MF), partly skimmed (2 % MF), partly skimmed (1 % MF), partly skimmed calcium enriched (1 % MF + Ca), and skim (<0.05 %) milk were purchased from local supermarkets. Ion exchange chromatography, solvent extraction, and ammonium sulfate precipitation methods were applied to the separation of the inorganic, lipidic and proteic fractions of iodine in milk. The levels of iodine were measured by INAA in total reactor and epi-cadmium (EINAA) neutron flux in conjunction with conventional gamma-ray and Compton suppression spectrometry (CSS). A pseudo-cyclic INAA method coupled with CSS (PC-INAA-CSS) was also explored as an instrumental option to further lower the detection limit of iodine. The detection limits of 0.06, 0.06 and 0.02 μg mL?1 for iodine were obtained using INAA-CSS, EINAA-CSS, and PC-INAA-CSS methods, respectively. Although the PC-INAA-CSS method provided the lowest detection limit, the INAA-CSS method was sufficient for the determination of total iodine in almost all samples analyzed in this work. The total iodine concentrations (μg mL?1) were: 0.40 ± 0.01 (in 3.25 % MF), 0.40 ± 0.01 (2 % MF), 0.42 ± 0.01 (1 % MF), 0.42 ± 0.01 (<0.05 %), and 0.96 ± 0.01 (1 % MF + Ca) milk samples. Iodine bound to various fractions of the milk samples analyzed, in percent of total iodine content, ranged: (0.05–1.8), (1.9–4.8), (90–95) for the lipidic, proteic and anionic inorganic fractions respectively. Iodine recovery in all cases was higher than 96 %.  相似文献   

11.

Iodine abundances in NBS biological SRMs and various organs of rats were evaluated by epithermal neutron activation analysis with a boron carbide filter. Detectability of iodine in different biological materials by this method is discussed.

  相似文献   

12.
HPLC with fluorescence detection is considered for confirmatory analysis of group B veterinary drugs by the European Union legislation. A procedure for confirming the presence of anti-inflammatory non-steroidal drug (NSAID) residues in bovine milk by reversed phase high-performance liquid chromatography with fluorescence detection is herein described. The native fluorescence of nine drugs belonging to different NSAID sub-classes, namely flurbiprofen, carprofen, naproxen, vedaprofen, 5-hydroxy-flunixin, niflumic acid, mefenamic acid, meclofenamic acid and tolfenamic acid, allowed for detection in bovine milk down to 0.25–20.0 μg/kg. Confirmation of the nine NSAIDs is attained by fluorescence detection at characteristic excitation and emission wavelengths. The procedure described is simple and selective. Limits of quantification (LOQs) ranging between 0.25 and 20 μg/kg were measured; satisfactory trueness and within-laboratory reproducibility data were calculated at LOQ spiking levels, apart from 5-hydroxy-flunixin. The procedure developed is used in our laboratory for confirmation of each one of the above mentioned NSAIDs in bovine milk, to support results after HPLC quantitative analysis with UV–vis detection.  相似文献   

13.
The absolute concentrations of iodine, bromine and chlorine in milk, have been determined by epithermal neutron activation followed by high resolution gamma-ray spectrometry. Two kinds of milk commonly consumed in Israel have been investigated. The concentration of iodine, bromine and chlorine were found to be 0.18–0.30 g/ml, 2.02–2.85 g/ml and 0.65 mg/ml, respectively. The method is fast, selective, accurate and highly sensitive.  相似文献   

14.
A rapid, high sensitivity method has been developed for the determination of As(III), As(V), Sb(III) and Sb(V) in milk samples by using hydride generation atomic fluorescence spectrometry. The method is based on the leaching of As and Sb from milk through the sonication of samples with aqua regia followed by direct determination of the corresponding hydrides both before and after reduction with KI. It was confirmed by recovery experiments on spiked commercially available samples that neither the reduced nor the oxidized forms of the elements under study or mixtures of the two oxidation states were modified by the room temperature sample treatment with aqua regia. The methodologies developed provided 3σ limit of detection values of 8.1, 10.3, 5.4 and 7.7 ng l−1 for As(III), As(V), Sb(III) and Sb(V) in the diluted samples. Average relative standard deviation values of 5.7, 5.5, 8.2 and 4.7% were found for determination of As(III), As(V), Sb(III) and Sb(V) in commercially available samples of different composition and origin containing from 3.5 to 13.6 ng g−1 total As and from 4.9 to 11.8 ng g−1 total Sb, it being confirmed that As(V) and Sb(V) are the main species present in the samples analyzed (62±5 and 73±5%, respectively). The time required to determine As and Sb species in milk involves 10 min sonication and 30 min prereduction but these steps can be carried out for several sample simultaneously. Additionally the fluorescence measurement step involves less than 20 min for three replicates of all the four measurements required. So, in less than 2 h it is possible to determine the content of As(III), As(V), Sb(III) and Sb(V) in four samples.  相似文献   

15.
Instrumental neutron activation analysis was carried out to obtain the normal concentration of trace elements in bovine tissues (heart, liver, kidney, spleen, lymph nodes) and serum. Concentrations of 17 elements were determined. In this paper, concentrations of Al, Br, Cs, In and Rb are given and correlations of concentrations are discussed between Cl and Br and between K and Cs or Rb. Significant positive correlations have been found between Cl and Br concentrations in all tissues, between K and Cs concentrations in tissues excluding kidney, and between K and Rb concentrations in tissues excluding liver.  相似文献   

16.
Samples of diets from China, Japan, Korea, India, Pakistan and Philippines were analyzed using epithermal and radiochemical neutron activation analysis (ENAA and RNAA, respectively) within the framework of the IAEA project “Reference Asian Man”. The RNAA procedure was based on alkaline-oxidative fusion followed by extraction of elemental iodine in chloroform. The analytical methods employed are discussed in terms of detection limits and uncertainties of the results obtained. For quality control purposes a number of NIST biological reference materials, namely diets and foods were analyzed. Results for the diet samples indicate that achieving the WHO recommended daily allowance for iodine may be a problem in most of the above given countries. This revised version was published online in August 2006 with corrections to the Cover Date.  相似文献   

17.
Evaluation of minimal detectable amounts (MDA) of iodine in various or specified irradiation and measurement conditions is described. Interfering contributions due to Na and Cl to the spectral background as well as the dead time of detection system were calculated in details based on an experimental approach. The MDA of iodine for some important biological samples with various Na and Cl concentrations can be evaluated and predicted according to the specified irradiation and measurement arrangements to meet the requirement of analytical purposes.  相似文献   

18.
An epithermal instrumental neutron activation analysis (EINAA) method, using a boron nitride irradiation capsule compatible with use in the University of Missouri Research Reactor pneumatic-tube irradiation facility, has been developed for the analysis of iodine in human nails. The principal objective was to determine if the nail could be used as a means of monitoring dietary intake of iodine. The EINAA method was used to analyze nails from subjects having iodine intakes that could be qualitatively differentiated. Iodine concentrations in nails from these subjects were positively correlated with apparent iodine intake.  相似文献   

19.
Summary Regarding the favourably sensitive nuclear characteristics of iodine and of selenium but the very different half lives of their induced nuclides 128I and 75Se, a radiochemical neutron activation analysis method for simultaneous determination of these elements in a single sample was developed. It is based on the double irradiation LICSIR technique — Long Irradiation for Se (40h), Cooling (a week or more), Short Irradiation for iodine (1–15 min) with following Radiochemistry. After the second short irradiation, the sample is ignited in an oxygen flask and iodine and selenium are sequentially and selectively extracted as elemental iodine and 5-nitro-2,1,3 benzoselena diazole chelate. With the described method biological samples were analysed and the reliability of the results was checked by the analyses of different standard reference materials. Good agreement with certified values and high radiochemical purity of the spectra show the applicability of the radiochemical separation developed.  相似文献   

20.
Iodine is an essential element of human nutrition. Nearly a third of the global population has insufficient iodine intake and is at risk of developing Iodine Deficiency Disorders (IDD). Most countries have iodine supplementation and monitoring programs. Urinary iodide (UI) is the biomarker used for epidemiological studies; only a few methods are currently used routinely for analysis. These methods either require expensive instrumentation with qualified personnel (inductively coupled plasma-mass spectrometry, instrumental nuclear activation analysis) or oxidative sample digestion to remove potential interferences prior to analysis by a kinetic colorimetric method originally introduced by Sandell and Kolthoff ∼75 years ago. The Sandell–Kolthoff (S–K) method is based on the catalytic effect of iodide on the reaction between Ce4+ and As3+. No available technique fully fits the needs of developing countries; research into inexpensive reliable methods and instrumentation are needed. There have been multiple reviews of methods used for epidemiological studies and specific techniques. However, a general review of iodine determination on a wide-ranging set of complex matrices is not available. While this review is not comprehensive, we cover the principal developments since the original development of the S–K method.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号