首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 13 毫秒
1.
Xiao Q  Hu B  Yu C  Xia L  Jiang Z 《Talanta》2006,69(4):848-855
A single-drop microextraction (SDME) procedure was developed for the analysis of organophosphorus pesticides (OPPs) in water and fruit juice by gas chromatography (GC) with flame photometric detection (GC-FPD). The significant parameters affecting the SDME performance such as selection of microextraction solvent, solvent volume, extraction time, stirring rate, sample pH and temperature, and ionic strength were studied and optimized. Two types of SDME mode, static and cycle-flow SDME, were evaluated. The static SDME procedure provided more sensitive analysis of the target analytes. Therefore, static SDME with tributyl phosphate (TBP) as internal standard was selected for the real sample analysis. The limits of detection (LODs) in water for the six studied compounds were between 0.21 and 0.56 ng/mL with the relative standard deviations ranging from 1.7 to 10.0%. Linear response data was obtained in the concentration range of 0.5-50 ng/mL (except for dichlorvos 1.0-50 ng/mL) with correlation coefficients from 0.9995 to 0.9999. Environmental water sample collected from East Lake and fruit juice samples were successfully analyzed using the proposed method, but none of the analytes in both lake water and fruit juice were detected. The recoveries for the spiked water and juice samples were from 77.7 to 113.6%. Compared with the conventional methods, the proposed method enabled a rapid and simple determination of organophosphorus pesticides in water and fruit juice with minimal solvent consumption and a higher concentration capability.  相似文献   

2.
A method for the determination of organophosphorus pesticides (diazinon, fenitrothion, fenthion, quinalphos, triazophos, phosalon and pyrazophos) in fruit (pears) and fruit juice samples was developed and validated. The samples were diluted with water, extracted by solid-phase microextraction (SPME) and analysed by gas chromatography (GC) using a flame photometric detector in phosphorous mode. Limits of detection of the method for fruit and fruit juice matrices were below 2 micrograms/kg for all pesticides. Relative standard deviations for triplicate analyses of samples fortified at 25 micrograms/kg of each pesticide were not higher than 8.7%. Recovery tests were performed for concentrations between 25 and 250 micrograms/kg. Mean recoveries for each pesticide were all above 75.9% and below 102.6% for juice, and between 70 and 99% for fruit except for pyrazophos in the fruit sample (with mean recovery of 53%). Therefore, the proposed method is applicable in the analysis of pesticides in fruit matrices and the use of the method in routine analysis of pesticide residues is discussed.  相似文献   

3.
Zhang M  Huang J  Wei C  Yu B  Yang X  Chen X 《Talanta》2008,74(4):599-604
A new approach for the extraction of nine kinds of organochlorine pesticides (OCPs) from vegetable samples coupling single-drop microextraction with gas chromatography-mass spectrometry was presented. Experimental parameters, such as organic solvent, exposure time, agitation and organic drop volume were controlled and optimized. An effective extraction was achieved by suspending a 1.00microL mixed drop of p-xylene and acetone (8:2, v/v) to the tip of a microsyringe immersed in a 2mL donor aqueous solution and stirred at 400rpm. The approach was applied to the determination of OCPs in vegetable samples with a linearity range of 0.05-20ng mL(-1) for alpha-, beta-, gamma-, delta-hexachlorobenzene (BHC) and dicofol, 0.5-20ng mL(-1) for dieldrin and 2,2-bis(4-chlorophenyl)-1,1-dichloroethane (DDD) or 0.5-50ng mL(-1) for 2,2-bis(4-chlorophenyl)-1,1-dichloroethylene (DDE) and 2-(2-chlorophenyl)-2 (4-chlorophenyl)-1,1,1-trichloroethane (p,p'-DDT). Correspondingly, the determination limit at an S/N of 3 ranged from 0.05ng mL(-1) for alpha-, beta-, gamma-, delta-BHC to 0.2ng mL(-1) for dicofol, dieldrin or p,p'-DDT. The relative recoveries were from 63.3 to 100%, with repeatability ranging from 8.74 to 18.9% (relative standard deviation, R.S.D.). The single-drop microextraction was proved to be a fast and simple approach for the pre-concentration of organochlorine pesticides in vegetable samples.  相似文献   

4.
In this article, a new method for the determination of organophosphorus pesticides (OPPs) in cucumber and watermelon was developed by using dispersive liquid-liquid microextraction (DLLME) and gas chromatography-flame photometric detection (GC-FPD). Acetonitrile (MeCN) was used as extraction solvent for the extraction of OPPs from plant samples. When the extraction process was finished, the target analytes in the extraction solvent were rapidly transferred from the MeCN extract to another small volume of organic solvent, chlorobenzene, using DLLME. Recovery tests were performed for concentrations between 0.5 and 20 microg/kg; recoveries for each target analyte were in the range between 67 and 111%. The repeatability of the proposed method, expressed as relative standard deviation, varied between 2 and 9% (n=3). Limits of detection of the method for watermelon and cucumber were found ranging from 0.010 to 0.190 microg/kg for all the target pesticides. Compared with the conventional sample preparation method, the proposed method has the advantage of being quick and easy to operate, and having high-enrichment factors and low consumption of organic solvent.  相似文献   

5.
This paper described a simple approach to prepare a small bell-mouthed extraction device for single-drop microextraction (SDME). Analytical sensitivity was improved by increasing the suspended acceptor volume. Because of the increased contact area and the rough inner surface of the extraction device, the stability of drop was markedly increased. The merits of the proposed method were demonstrated by using 1-octanol as extractant and with cyanazine, simazine and atrazine as model compounds. The related parameters and the effect of humic acid were systematically investigated. Under the optimized extraction conditions, the linear range, detection limit (S/N=3) and precision (RSD, n=6) were 0.2-50, 0.06microgL-1, 5.7% for cyanazine, 0.1-25, 0.03microgL-1, 6.7% for simazine, and 0.15-37.5, 0.04microgL-1, 5.0% for atrazine, respectively. The established method was applied to determine the target compounds in four real water samples, and the satisfactory spiked recoveries at two concentration levels were obtained. Moreover, the comparison of the proposed SDME with the traditional SDME was performed. These results indicated that the proposed improvement made SDME be a competitive analytical tool and an alternative of the traditional methods for the analysis of organic pollutants at trace level.  相似文献   

6.
Exposing a microlitre organic solvent drop to the headspace of an aqueous sample contaminated with ten chlorobenzene compounds proved to be an excellent preconcentration method for headspace analysis by gas chromatography-mass spectrometry (GC-MS). The proposed headspace single-drop microextraction (SDME) method was initially optimised and the optimum experimental conditions found were: 2.5 microl toluene microdrop exposed for 5 min to the headspace of a 10 ml aqueous sample containing 30% (w/v) NaCl placed in 15 ml vial and stirred at 1000 rpm. The calculated calibration curves gave a high level of linearity for all target analytes with correlation coefficients ranging between 0.9901 and 0.9971, except for hexachlorobenzene where the correlation coefficient was found to be 0.9886. The repeatability of the proposed method, expressed as relative standard deviation varied between 2.1 and 13.2% (n = 5). The limits of detection ranged between 0.003 and 0.031 microg/l using GC-MS with selective ion monitoring. Analysis of spiked tap and well water samples revealed that matrix had little effect on extraction. A comparative study was performed between the proposed method, headspace solid-phase microextraction (SPME), solid-phase extraction (SPE) and EPA method 8121. Overall, headspace SDME proved to be a rapid, simple and sensitive technique for the analysis of chlorobenzenes in water samples, representing an excellent alternative to traditional and other, recently introduced, methods.  相似文献   

7.
In this work, a simple, rapid and sensitive sample pretreatment technique, dispersive liquid-liquid microextraction (DLLME) coupled with high performance liquid chromatography-fluorescence detection (HPLC-FLD), has been developed to determine carbamate (carbaryl) and organophosphorus (triazophos) pesticide residues in water and fruit juice samples. Parameters, affecting the DLLME performance such as the kind and volume of extraction and dispersive solvents, extraction time and salt concentration, were studied and optimized. Under the optimum extraction conditions (extraction solvent: tetrachloroethane, 15.0 μL; dispersive solvent: acetonitrile, 1.0 mL; no addition of salt and extraction time below 5 s), the performance of the proposed method was evaluated. The enrichment factors for the carbaryl and triazophos were 87.3 and 275.6, respectively. The linearity was obtained in the concentration range of 0.1-1000 ng mL−1 with correlation coefficients from 0.9991 to 0.9999. The limits of detection (LODs), based on signal-to-noise ratio (S/N) of 3, ranged from 12.3 to 16.0 pg mL−1. The relative standard deviations (RSDs, for 10 ng mL−1 of carbaryl and 20 ng mL−1 of triazophos) varied from 1.38% to 2.74% (n = 6). The environmental water (at the fortified level of 1.0 ng mL−1) and fruit juice samples (at the fortified level of 1.0 and 5.0 ng mL−1) were successfully analyzed by the proposed method, and the relative recoveries of them were in the range of 80.4-114.2%, 89.8-117.9% and 86.3-105.3%, respectively.  相似文献   

8.
The solvation parameter model has been applied to the characterization of micellar electrokinetic chromatographic (MEKC) systems with mixtures of lithium dodecyl sulfate and lithium perfluorooctanesulfonate as surfactant. The variation in MEKC surfactant composition results in changes in the coefficients of the correlation equation, which in turns leads to information on solute-solvent and solute-micelle interactions. Lithium perfluorooctanesulfonate is more dipolar and hydrogen bond acidic but less polarizable and hydrogen bond basic than lithium dodecyl sulfate. Therefore mixtures of lithium dodecyl sulfate and lithium perfluorooctanesulfonate cover a very wide range of polarity and hydrogen bond properties, which in turn results in important selectivity changes for analytes with different solute properties.  相似文献   

9.
Developments in single-drop microextraction   总被引:3,自引:0,他引:3  
Single-drop microextraction (SDME) has become a very popular liquid-phase microextraction technique because it is inexpensive, easy to operate and nearly solvent-free. Essentially, SDME combines extraction (and conceivably, cleanup) and concentration in a minimum number of steps, and thereafter, direct extract introduction into an analytical system. In this review, in order to encourage further development of SDME, we focus on its recent developments in its various guises. Its applications when used in combination with different analytical techniques, such as gas chromatography, high-performance liquid chromatography, inductively-coupled plasma mass spectrometry, capillary electrophoresis, mass spectrometry and electrothermal atomic absorption spectrometry, are summarized. SDME does have some limitations, and these are also discussed as well. Finally, an outlook on the future of the technique is given.  相似文献   

10.
This paper compares solid-phase microextraction (SPME) with a recently developed extraction method called single-drop microextraction (SDME) for the analysis of nitroaromatic explosives in water samples. The two techniques are examined in terms of procedure, chromatographic analysis and method performance. All practical considerations for both techniques are also reviewed. SPME requires dedicated apparatus and is relatively expensive, as the fiber's lifetime is limited. However, it has the advantages over SDME that it can be easily used for headspace analysis and has lower detection limits for all the target analytes. SDME requires more elaborate manual operations, thus affecting linearity and precision.  相似文献   

11.
A new technique, headspace single-drop microextraction (HS-SDME) with in-drop derivatization, was developed. Its feasibility was demonstrated by analysis of the model compounds, aldehydes in water. A hanging microliter drop of solvent containing the derivatization agent of O-2,3,4,5,6-(pentaflurobenzyl)hydroxylamine hydrochloride (PFBHA) was shown to be an excellent extraction, concentration, and derivatization medium for headspace analysis of aldehydes by GC-MS. Using the microdrop solvent with PFBHA, acetaldehyde, propanal, butanal, hexanal, and heptanal in water were headspace extracted and simultaneously derivatized. The formed oximes in the microdrop were analyzed by GC-MS. HS-SDME and in-drop derivatization parameters (extraction solvent, extraction temperature, extraction time, stirring rate microdrop volume, and the headspace volume) and the method validations (linearity, precision, detection limit, and recovery) were studied. Compared to liquid-liquid extraction and solid-phase microextraction, HS-SDME with in-drop derivatization is a simple, rapid, convenient, and inexpensive sample technique.  相似文献   

12.
固相微萃取在有机磷农药残留分析中的应用   总被引:13,自引:1,他引:13  
将固相微萃取与其它样品前处理技术进行比较,并对其在有机磷农药残留分析中的应用进行了综述,还就固相微萃取技术及其发展的一些最新动态进行介绍和展望。  相似文献   

13.
Headspace solid-phase microextraction (SPME) has been developed for the analysis of common organophosphorus pesticides in soil. Factors such as adsorption-time, sampling temperature and matrix modification by addition of water were carefully considered to optimize the extraction efficiency. This technique could achieve limits of detection of 143 ng/g for Malathion and Parathion, and 28.6 ng/g for Phorate, Diazinon and Disulfoton in humic soil when the extracted sample was analyzed by gas chromatography-flame ionization detector (GC-FID). Lower limits of detection of 28.6 ng/g for Malathion and Parathion, and 14.3 ng/g for Phorate, Diazinon and Disulfoton can be achieved by analyzing the extracted sample with gas chromatography/mass spectrometric detector (GC/MS). As the extraction efficiency was generally better when analyzing sandy soil, the limits of detection are envisaged to be even better for such a matrix. The technique was found to be reliable with good precision of about 6.5% RSD for the sandy soil and about 15% for the humic material. The poorer precision of extraction from the humic material is probably related to the poorer homogeneity of this material. The linearity of extraction was good with linear calibration in the range of 0.143 to 28.6 μg/g. Finally, headspace SPME was compared to aqueous extraction of soil followed by SPME (LE-SPME). The recoveries obtained by headspace SPME were comparable to those from liquid-liquid extraction of soil followed by SPME. However, the analysis of headspace SPME has less background interference. Perhaps, the greatest advantage of this technique is its non-destructive nature so that it is possible to perform further laboratory analysis of the samples after headspace SPME has been carried out. Received: 13 July 1998 / Revised: 10 November 1998 / Accepted: 17 November 1998  相似文献   

14.
Headspace solid-phase microextraction (SPME) has been developed for the analysis of common organophosphorus pesticides in soil. Factors such as adsorption-time, sampling temperature and matrix modification by addition of water were carefully considered to optimize the extraction efficiency. This technique could achieve limits of detection of 143 ng/g for Malathion and Parathion, and 28.6 ng/g for Phorate, Diazinon and Disulfoton in humic soil when the extracted sample was analyzed by gas chromatography-flame ionization detector (GC-FID). Lower limits of detection of 28.6 ng/g for Malathion and Parathion, and 14.3 ng/g for Phorate, Diazinon and Disulfoton can be achieved by analyzing the extracted sample with gas chromatography/mass spectrometric detector (GC/MS). As the extraction efficiency was generally better when analyzing sandy soil, the limits of detection are envisaged to be even better for such a matrix. The technique was found to be reliable with good precision of about 6.5% RSD for the sandy soil and about 15% for the humic material. The poorer precision of extraction from the humic material is probably related to the poorer homogeneity of this material. The linearity of extraction was good with linear calibration in the range of 0.143 to 28.6 μg/g. Finally, headspace SPME was compared to aqueous extraction of soil followed by SPME (LE-SPME). The recoveries obtained by headspace SPME were comparable to those from liquid-liquid extraction of soil followed by SPME. However, the analysis of headspace SPME has less background interference. Perhaps, the greatest advantage of this technique is its non-destructive nature so that it is possible to perform further laboratory analysis of the samples after headspace SPME has been carried out.  相似文献   

15.
A method based on solid-phase microextraction (SPME) and gas chromatography with mass spectrometry (GC/MS) for the determination of 18 organophosphorus pesticides (OPPs) in textiles is described. Commercially available SPME fibers, 100 μm PDMS and 85 μm PA, were compared and 85 μm PA exhibited better performance to the OPPs. Various parameters affecting SPME, including extraction and desorption time, extraction temperature, salinity and pH, were studied. The optimized conditions were: 35 min extraction at 25 °C, 5% NaSO4 content, pH 7.0, and 3.5 min desorption in GC injector port at 250 °C. The linear ranges of the SPME-GC/MS method were 0.1-500 μg L−1 for most of the OPPs. The limits of detection (LODs) ranged from 0.01 μg L−1 (for bromophos-ethyl) to 55 μg L−1 (for azinphos-methyl) and the RSDs were between 0.66% and 9.22%. The optimized method was then used to analyze 18 OPPs in textile sample, and the determined recoveries were ranged from 76.7% to 126.8%. Moreover, the distribution coefficients of the OPPs between 85 μm PA fiber and simulative sweat solution (Kpa/s) were determined. The determined Kpa/s of the OPPs correlated well with their octanol-water partition coefficients (r = 0.764 and 0.678) and water solubility (= −0.892 and −0.863).  相似文献   

16.
A rapid and simple single-drop microextraction method (SDME) has been used to preconcentrate eighteen organochlorine pesticides (OCPs) from water samples with a complex matrix. Exposing two microlitre toluene drop to an aqueous sample contaminated with OCPs proved an excellent preconcentration method prior to analysis by gas chromatography-mass spectrometry (GC-MS). A Plackett-Burman design was used for screening and a central composite design for optimizing the significant variables in order to evaluate several possibly influential and/or interacting factors. The studied variables were drop volume, aqueous sample volume, agitation speed, ionic strength and extraction time. The optimum experimental conditions of the proposed SDME method were: 2 μL toluene microdrop exposed for 37 min to 10 mL of the aqueous sample containing 0% w/v NaCl and stirred at 380 rpm.The calculated calibration curves gave high-level linearity for all target analytes with correlation coefficients ranging between 0.9991 and 0.9999. The repeatability of the proposed method, expressed as relative standard deviation, varied between 5.9 and 9.9% (n = 8). The detection limits were in the range of 0.022-0.101 μg L−1 using GC-MS with selective ion monitoring. The LOD values obtained are able to detect these OCPs in aqueous matrices as required by EPA Method 625. Analysis of spiked effluent wastewater samples revealed that the matrix had no effect on extraction for eleven of the analytes but exerted notable effect for the other analytes.  相似文献   

17.
A liquid‐phase microextraction coupled with LC method has been developed for the determination of organophosphorus pesticides (methidation, quinalphos and profenofos) in drinking water samples. In this method, a small amount (3 μL) of isooctane as the acceptor phase was introduced continually to fill‐up the channel of a 1.5 cm polypropylene hollow fiber using a microsyringe while the hollow fiber was immersed in an aqueous donor solution. A portion of the acceptor phase (ca. 0.4 μL) was first introduced into the hollow fiber and additional amounts (ca. 0.2 μL) of the acceptor phase were introduced to replenish at intervals of 3 min until set end of extraction (40 min). After extraction, the acceptor phase was withdrawn and transferred into a 2 mL vial for a drying step prior to injection into a LC system. Parameters that affect the extraction efficiency were studied including the organic solvent, length of fiber, volume of acceptor and donor phase, stirring rate, extraction time, and effect of salting out. The proposed method provided good enrichment factors of up to 189.50, with RSD ranging from 0.10 to 0.29%, analyte recoveries of over 79.80% and good linearity ranging from 10.0 to 1.25 mg/L. The LOD ranged from 2.86 to 82.66 μg/L. This method was applied successfully to the determination of organophosphorus pesticides in selected drinking water samples.  相似文献   

18.
In the present work the single-drop microextraction (SDME) technique coupled with GC-NPD and GC-ECD was evaluated for the determination of multi-class pesticides in vegetables. The donor sample solution preparation was optimized by testing different mixtures of solvents and dilutions with water. The SDME procedure was optimized by controlling drop organic solvent, drop volume, agitation, and exposure time. The optimum sample preparation was achieved with the use of a mixture of acetone/H(2)O (10/90, v/v) in donor sample solution preparation and the consequent SDME using a toluene drop under mild stirring for 25min. The efficiency of the extraction process was studied in fortified tomato and courgette samples and matrix effects were further estimated. The proposed method showed good linearity, limits of detection at the sub-microgkg(-1) level and high precision (RSD <15%) and was applied with success in real vegetable samples showing that SDME can be a promising way for sample preparation in pesticide residue analysis.  相似文献   

19.
We have developed a new method for single-drop microextraction (SDME) for the preconcentration of organochlorine pesticides (OCP) from complex matrices. It is based on the use of a silicone ring at the tip of the syringe. A 5 μL drop of n-hexane is applied to an aqueous extract containing the OCP and found to be adequate to preconcentrate the OCPs prior to analysis by GC in combination with tandem mass spectrometry. Fourteen OCP were determined using this technique in combination with programmable temperature vaporization. It is shown to have many advantages over traditional split/splitless injection. The effects of kind of organic solvent, exposure time, agitation and organic drop volume were optimized. Relative recoveries range from 59 to 117 %, with repeatabilities of <15 % (coefficient of variation) were achieved. The limits of detection range from 0.002 to 0.150 μg kg?1. The method was applied to the preconcentration of OCPs in fresh strawberry, strawberry jam, and soil.
Figure
A representative figure for OCP analysis by a modified SDME method.  相似文献   

20.
Heterocyclic amines (HAs) were analysed in meat extract samples using a new method based on pressurised liquid extraction (PLE) and liquid chromatography-tandem mass spectrometry. This method combines the use of a pressurised fluid with a triple quadrupole MS/MS system, resulting in benefits from both systems: high extraction efficiency and sensitivity. The effects of solvent type and PLE operational parameters, such as temperature and extraction time, were studied to obtain maximum recovery of the analytes with minimum contamination. HA extraction was best achieved using dichloromethane/acetone (50/50, v/v) at 80 degrees C for 10 min. Recoveries ranged from 45% to 79% with good quality parameters: limit of detection values between 0.02 and 1 ng g(-1), linearity (r(2)>0.997), and run-to-run and day-to-day precisions with relative standard deviations lower than 13% achieved at both low (0.20 microg g(-1)) and medium (1.0 microg g(-1)) concentrations. This method reduces sample manipulation and total extraction time by nearly four-fold compared to conventional solid phase extraction. The optimised method was validated using laboratory reference material based on a meat extract, and was successfully applied to HA analysis in several cooked beef samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号