1.
Methods for the determination of 5 major (Ca, K, Mg, Na and P) and 14 minor elements (Al, Ba, Cd, Co, Cu, Fe, Ga, Mn, Mo, Ni, Pb, Rb, Sr and Zn) in vegetable seeds by ICP OES and by ICP-MS, respectively, are proposed. After a common sample preparation consisting of smashing and homogenization in an agata mortar, followed by acid digestion in a microwave oven, the diluted sample solutions were measured in the spectrometers using conventional pneumatic nebulizers. External calibration with aqueous standard solutions was used for both techniques. Internal standard was not required, due to the absence of non-spectral interference. For the major elements, the detection limits were in the range of 0.01 (Mg) to 0.3 µg g− 1 (Na and K) and for the minor elements they were in the range of 0.001 (several) to 0.4 µg g− 1 (Fe). The detection limits were adequate for the seed analysis. The accuracy was validated by analyzing a botanical certified reference material (Pine Needles). Agreement of the concentrations with the certified or informed values was obtained, according to the t-test for a confidence level of 95%. The relative standard deviations were below 10% indicating an adequate precision. Seeds from seven different plants were analyzed: cotton seed, sunflower, castor bean, fodder turnip, curcas bean, soybean and tung. The element concentrations varied considerably in the different samples. The results were also evaluated using the principal component analysis.  相似文献   

2.
The fast sequential multi-element determination of 11 elements present at different concentration levels in environmental samples and drinking waters has been investigated using high-resolution continuum source flame atomic absorption spectrometry. The main lines for Cu (324.754 nm), Zn (213.857 nm), Cd (228.802 nm), Ni (232.003 nm) and Pb (217.001 nm), main and secondary absorption lines for Mn (279.482 and 279.827 nm), Fe (248.327, 248.514 and 302.064 nm) and Ca (422.673 and 239.856 nm), secondary lines with different sensitivities for Na (589.592 and 330.237 nm) and K (769.897 and 404.414 nm) and a secondary line for Mg (202.582 nm) have been chosen to perform the analysis. A flow injection system has been used for sample introduction so sample consumption has been reduced up to less than 1 mL per element, measured in triplicate. Furthermore, the use of multiplets for Fe and the side pixel registration approach for Mg have been studied in order to reduce sensitivity and extend the linear working range. The figures of merit have been calculated and the proposed method was applied to determine these elements in a pine needles reference material (SRM 1575a), drinking and natural waters and soil extracts. Recoveries of analytes added at different concentration levels to water samples and extracts of soils were within 88–115% interval. In this way, the fast sequential multi-element determination of major and minor elements can be carried out, in triplicate, with successful results without requiring additional dilutions of samples or several different strategies for sample preparation using about 8–9 mL of sample.  相似文献   

3.
A method for determination of B, Ca, Cu, Fe, K, Mg, Mn, Mo, P, S and Zn in plant tissues by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS) is proposed. This method is based on special features of HR-CS-AAS, such as side pixel registration, wavelength integrated absorbance, and molecular absorption bands, for determining macro- and micronutrients in foliar analysis without requiring several different strategies for sample preparation and adjustment of the analytes concentration ranges. Plant samples were analyzed and results for certified materials were in agreement at a 95% confidence level (paired t-test) with reference values. Recoveries of analytes added to plant digests varied within the 82–112% interval. Relative standard deviations (n = 12) were lower than or equal to 5.7% for all analytes in all concentration ranges.  相似文献   

4.
Ultrasonic slurry sampling electrothermal vaporisation inductively coupled plasma mass spectrometry (USS-ETV-ICP-MS) was applied to the elemental analysis of silicate based minerals, such as talc or quartz, without any pre-treatment except the grinding of the sample. The electrothermal vaporisation device consists of a tungsten coil connected to a home-made power supply. The voltage program, carrier gas flow rate and sonication time were optimised in order to obtain the best sensitivity for elements determined. The relationship between the amount of sample in the slurry and the signal intensity was also evaluated. Unfortunately, in all cases, quantification had to be carried out by the standard additions method owing to the strong matrix interferences. The global precision of the proposed method was always better than 12%. The limits of detection, calculated as three times the standard deviation of the blank value divided by the slope of the calibration curve, were between 0.5 ng/g for As and 3.5 ng/g for Ba. The method was validated by comparing the concentrations found for Cu, Mn, Cr, V, Li, Pb, Sn, Mg, U, Ba, Sr, Zn, Sb, Rb and Ce using the proposed methodology with those obtained by conventional nebulisation ICP-MS after acid digestion of the samples in a microwave oven. The concentration range in the solid samples was between 0.2 μg/g for Cr and 60 μg/g for Ba. All results were statistically in agreement with those found by conventional nebulisation.  相似文献   

5.
This paper proposes an alternative analytical method using energy dispersive X-ray fluorescence (EDXRF) to determine Fe and Cu in gasoline samples. In the proposed procedure, samples were distilled and the distillation residues were spotted on cellulose paper disk to form a uniform thin film and to produce a homogeneous and reproducible interface to the XRF instrument. The disks were dried at 60 °C for 20 min and copper and iron were determined directly in the solid phase at 6.40 and 8.04 keV, respectively. The calibration curves showed linear response in the 20-800 μg L−1 concentration range of each metal. The precisions (repeatability) calculated from 15 consecutive measurements and defined as the coefficient of variation of solutions containing 100 μg L−1 of Fe and Cu were 7.8 and 8.1%, respectively. The limits of detection (LOD), defined as the analyte concentration that gives a response equivalent to three times the standard deviation of the blank (n = 10), were found to be 10 and 15 μg L−1 for Fe and Cu, respectively. The proposed method was applied to copper and iron determination in gasoline samples collected from different gas stations.  相似文献   

6.
A new method for the direct analysis of coal using electrothermal vaporization inductively coupled plasma mass spectrometry and direct solid sample analysis was developed, aiming at the determination of Br and Cl. The procedure does not require any significant sample pretreatment and allows simultaneous determination of both elements to be carried out, requiring small mass aliquots of sample (about 0.5 mg). All operating parameters, including carrier gas flow-rate and RF power, were optimized for maximum sensitivity. The use of modifiers/aerosol carriers (Pd, Pd + Al and Pd + Ca) was evaluated, and the mixture of Pd and Ca was chosen, allowing pyrolysis and vaporization temperatures of 700 °C and 1900 °C, respectively. Chlorine was accurately determined using calibration against solid standards, whereas Br could also be determined using calibration against aqueous standard solutions. The limits of quantification were 0.03 μg g−1 for Br and 7 μg g−1 for Cl, and no spectral interferences were observed.  相似文献   

7.
Grigoletto T  Oliveira Ed  Gutz IG 《Talanta》2005,67(4):791-797
The new electrolytic dissolution in batch of aluminum alloys samples as grains or turns and the determination of Fe, Cu, Mn, Mg, Cr, Ni, Zn, Pb and Ti by ICP OES was investigated. In on-line electrodissolution procedures described in the literature, samples were restricted to be in the form of solid blocks or plates with one polished flat face. Here, the sample was loaded in the barrel of a modified disposable syringe (the anodic semi-cell) and pressed with a modified plunger fitted with a platinum disk to establish electrical contact with the analyte. This arrangement was introduced in a beaker containing the electrolyte (1 mol L−1 HNO3) and a platinum wire as the cathode. The resulting solution from electrodissolution (0.6 A) was used for the ICP OES determinations. The influence of the aluminum concentration increase on the determination of the elements was evaluated. Electrodissolution of certified reference materials and commercial samples revealed relative errors lower than 10% for the elements Fe, Cu, Mg, Ni, Cr, Zn and Ti (when their content is above 0.1%). Higher inaccuracies (>10%) were observed for Mn and for Fe in B.C.S. 268/1 reference material certified. The proposed method presented a relative standard deviations (R.S.D.) lower or circa 10% to all of the elements (except Pb). In comparison with traditional acid dissolution, the proposed electrodissolution method is relatively fast (about 30 min), it is clean (there is no projection of solution) and simple (heating and fumes exhaust system were not necessaries).  相似文献   

8.
A simple and fast method for the determination of As, Ba, Cd, Co, Cu, Fe, Ga, Mn, Mo, Ni, Pb, Rb, Se, Sr, Tl, U, V and Zn in biological samples by inductively coupled plasma mass spectrometry (ICP-MS), after sample solubilization with formic acid and introduction by a microconcentric nebulizer, is proposed. The sample is mixed with formic acid, kept at 90 °C for one hour and then diluted with nitric acid aqueous solution to a 50% v/v formic acid and 1% v/v nitric acid final concentrations. The final sample solution flow rate for introduction into the plasma was 30 μL min−1. The optimized and adopted nebulizer gas flow rate was 0.7 L min−1 and RF power was 800 W. These conditions are very different than those normally used when a conventional nebulizer is employed. Rodhium was used as internal standard. External calibration against aqueous standard solutions, without formic acid, could be used for quantification, except for As, Se and Zn. However, external calibration with 50% formic acid allows the determination of all analytes with high accuracy and it is recommended. The detection limits were between 0.0005 (Tl) and 0.22 mg kg−1 (Fe) and the precision expressed by the relative standard deviations (RSD) were between 0.2% (Sr) and 3.5% (Ga). Accuracy was validated by the analysis of four certified reference biological materials of animal tissues, comparing the results by linear regressions and by the t-test at a 95% confidence level. The recommended procedure avoids plasma instability and carbon deposit on the cones.  相似文献   

9.
The fast sequential multi-element determination of Ca, Mg, K, Cu, Fe, Mn and Zn in plant tissues by high-resolution continuum source flame atomic absorption spectrometry is proposed. For this, the main lines for Cu (324.754 nm), Fe (248.327 nm), Mn (279.482 nm) and Zn (213.857 nm) were selected, and the secondary lines for Ca (239.856 nm), Mg (202.582 nm) and K (404.414 nm) were evaluated. The side pixel registration approach was studied to reduce sensitivity and extend the linear working range for Mg by measuring at wings (202.576 nm; 202.577 nm; 202.578 nm; 202.580 nm; 202.585 nm; 202.586 nm; 202.587 nm; 202.588 nm) of the secondary line. The interference caused by NO bands on Zn at 213.857 nm was removed using the least-squares background correction. Using the main lines for Cu, Fe, Mn and Zn, secondary lines for Ca and K, and line wing at 202.588 nm for Mg, and 5 mL min− 1 sample flow-rate, calibration curves in the 0.1–0.5 mg L− 1 Cu, 0.5–4.0 mg L− 1 Fe, 0.5–4.0 mg L− 1 Mn, 0.2–1.0 mg L− 1 Zn, 10.0–100.0 mg L− 1 Ca, 5.0–40.0 mg L− 1 Mg and 50.0–250.0 mg L− 1 K ranges were consistently obtained. Accuracy and precision were evaluated after analysis of five plant standard reference materials. Results were in agreement at a 95% confidence level (paired t-test) with certified values. The proposed method was applied to digests of sugar-cane leaves and results were close to those obtained by line-source flame atomic absorption spectrometry. Recoveries of Ca, Mg, K, Cu, Fe, Mn and Zn in the 89–103%, 84–107%, 87–103%, 85–105%, 92–106%, 91–114%, 96–114% intervals, respectively, were obtained. The limits of detection were 0.6 mg L− 1 Ca, 0.4 mg L− 1 Mg, 0.4 mg L− 1 K, 7.7 µg L− 1 Cu, 7.7 µg L− 1 Fe, 1.5 µg L− 1 Mn and 5.9 µg L− 1 Zn.  相似文献   

10.
A method for the direct determination (without sample pre-digestion) of microelements in fruit juice by inductively coupled plasma optical emission spectrometry has been developed. The method has been optimized by a 23 factorial design, which evaluated the plasma conditions (nebulization gas flow rate, applied power, and sample flow rate). A 1:1 diluted juice sample with 2% HNO3 (Tetra Packed, peach flavor) and spiked with 0.5 mg L− 1 of Al, Ba, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, Sb, Sn, and Zn was employed in the optimization. The results of the factorial design were evaluated by exploratory analysis (Hierarchical Cluster Analysis, HCA, and Principal Component Analysis, PCA) to determine the optimum analytical conditions for all elements. Central point condition differentiation (0.75 L min− 1, 1.3 kW, and 1.25 mL min− 1) was observed for both methods, Principal Component Analysis and Hierarchical Cluster Analysis, with higher analytical signal values, suggesting that these are the optimal analytical conditions. F and t-student tests were used to compare the slopes of the calibration curves for aqueous and matrix-matched standards. No significant differences were observed at 95% confidence level. The correlation coefficient was higher than 0.99 for all the elements evaluated. The limits of quantification were: Al 253, Cu 3.6, Fe 84, Mn 0.4, Zn 71, Ni 67, Cd 69, Pb 129, Sn 206, Cr 79, Co 24, and Ba 2.1 µg L− 1. The spiking experiments with fruit juice samples resulted in recoveries between 80 and 120%, except for Co and Sn. Al, Cd, Pb, Sn and Cr could not be quantified in any of the samples investigated. The method was applied to the determination of several elements in fruit juice samples commercialized in Brazil.  相似文献   

11.
A simple, fast and sensitive direct method for the simultaneous determination of Cr and Fe in crude oil samples is proposed using high-resolution continuum source graphite furnace atomic absorption spectrometry. No sample preparation is used except for a 10-minute homogenization in an ultrasonic bath. Aliquots of 0.1–4 mg of the samples are weighed onto solid sampling platforms and analyzed directly using aqueous standards for calibration. The simultaneous determination was possible because there is a secondary Fe line at 358.120 nm in the vicinity of the most sensitive Cr line at 357.868 nm, and both absorption lines were within the wavelength interval covered by the linear charge-coupled device array detector. It has also been of advantage that the sensitivity ratio between the two analytical lines corresponded roughly to the concentration ratio of the two elements found in crude oil, and that both analytes have very similar volatility, so that no compromises had to be made regarding pyrolysis and atomization temperatures. Two oil reference materials have been analyzed and the results were in agreement with the certified or reported values. Characteristic masses of 3.6 pg and 0.5 ng were obtained for Cr and Fe, respectively. The limits of detection (3σ, n = 10) were 1 µg kg− 1 for Cr and 0.6 mg kg− 1 for Fe, and the precision, expressed as the relative standard deviation, ranged from 4 to 20%, which is often acceptable for a rapid direct analytical procedure. Five crude oils samples were analyzed.  相似文献   

12.
It has been demonstrated that laser induced breakdown spectrometry (LIBS) can be used as an alternative method for the determination of macro (P, K, Ca, Mg) and micronutrients (B, Fe, Cu, Mn, Zn) in pellets of plant materials. However, information is required regarding the sample preparation for plant analysis by LIBS. In this work, methods involving cryogenic grinding and planetary ball milling were evaluated for leaves comminution before pellets preparation. The particle sizes were associated to chemical sample properties such as fiber and cellulose contents, as well as to pellets porosity and density. The pellets were ablated at 30 different sites by applying 25 laser pulses per site (Nd:YAG@1064 nm, 5 ns, 10 Hz, 25 J cm−2). The plasma emission collected by lenses was directed through an optical fiber towards a high resolution echelle spectrometer equipped with an ICCD. Delay time and integration time gate were fixed at 2.0 and 4.5 μs, respectively. Experiments carried out with pellets of sugarcane, orange tree and soy leaves showed a significant effect of the plant species for choosing the most appropriate grinding conditions. By using ball milling with agate materials, 20 min grinding for orange tree and soy, and 60 min for sugarcane leaves led to particle size distributions generally lower than 75 μm. Cryogenic grinding yielded similar particle size distributions after 10 min for orange tree, 20 min for soy and 30 min for sugarcane leaves. There was up to 50% emission signal enhancement on LIBS measurements for most elements by improving particle size distribution and consequently the pellet porosity.  相似文献   

13.
A multiresidue HPLC method for identification and quantification of the synthetic acaricides fluvalinate, coumaphos, bromopropylate and its metabolite 4,4′-dibromobenzophenone in beeswax has been developed. Different techniques were tested and modified. The method consists of a sample preparation with isooctane followed by solid phase extraction using Florisil columns. Determination of the synthetic acaricides is achieved by HPLC with a photodiode array detector. Analytical performance of the proposed method, including sensitivity, accuracy and precision was satisfactory. The LOD for the analytes varied between 0.1 and 0.2 μg g−1 wax and the recoveries between 70 and 110%. Relative standard deviation of the repeatability of the method is <15% and reproducibility is <31%.  相似文献   

14.
A novel method, combining isotope dilution with standard additions, was developed for the analysis of eight elements (Mn, Fe, Co, Ni, Cu, Zn, Cd and Pb) in seawater. The method requires just 12 mL of sample and employs an off-line pre-concentration step using the commercially available chelating resin Toyopearl AF-Chelate-650M prior to determination by high resolution inductively coupled plasma magnetic sector mass spectrometry (ICP-MS). Acidified samples were spiked with a multi-element standard of six isotopes (57Fe, 62Ni, 65Cu, 68Zn, 111Cd and 207Pb) enriched over natural abundance. In addition, standard additions of a mixed Co and Mn standard were performed on sub-sets of the same sample. All samples were irradiated using a low power (119 mW cm−2; 254 nm) UV system, to destroy organic ligands, before pre-concentration and extraction from the seawater matrix. Ammonium acetate was used to raise the pH of the 12 mL sub-samples (off-line) to pH 6.4 ± 0.2 prior to loading onto the chelating resin. The extracted metals were eluted using 1.0 M Q-HNO3 and determined using ICP-MS. The method was verified through the analysis of certified reference material (NASS-5) and the SAFe inter-comparison samples (S1 and D2), the results of which are in good agreement with the certified and reported consensus values. We also present vertical profiles of the eight metals taken from the Bermuda Atlantic Time Series (BATS) station collected during the GEOTRACES inter-comparison cruise in June 2008.  相似文献   

15.
A sensitive analytical method for the determination of trace amounts of silicate in ultrapurified water was developed. The method is based on the formation of an ion associate of molybdosilicate with malachite green (MG) and the collection of the ion associate on a tiny membrane filter (diameter: 5 mm, and effective filtering diameter: 1 mm). The ion associate formed on the membrane filter is dissolved together with the membrane filter in 1 ml of methyl cellosolve (MC) and the absorbance of MC solution is measured at 627 nm by a flow injection-spectrophotometric detection technique. In this method, silicate in the original sample (ultrapurified water) is concentrated as the ion associate into a small volume of MC to get high sensitivity. As sample concentration takes place, the small amounts of silicate contained in the reagents used also become concentrated as the ion associate into MC. The original sample volumes are varied and evaporated to an identical volume. Therefore, the reagent added is fixed to the same volume. The absorbance increase linearly with increase in the original sample volume will be due only to silicate in the original samples (ultrapurified water). The resulting slopes obtained by varying the sample volumes are compared with the slope of the calibration graph, and thus named the slope comparison method (SCM). The SCM facilitates a more sensitive and accurate evaluation of silicate concentration in the samples than either common calibration method (CCM) or standard addition method (SAM) because it compensates for the influence of trace amounts of silicate contained in chemicals, reagent solution and solvent used. The calibration graph was constructed from 0 to 0.25 ng ml−1 of Si and the detection limit was 10 pg ml−1 (ppt) when 30 ml of samples was used. The standard deviation and relative standard deviation from six measurements of the reagent blanks were 0.0012 and 3.5%, respectively.  相似文献   

16.
The usefulness of the secondary line at 252.744 nm and the approach of side pixel registration were evaluated for the development of a method for sequential multi-element determination of Cu, Fe, Mn and Zn in soil extracts by high-resolution continuum source flame atomic absorption spectrometry (HR-CS FAAS). The influence of side pixel registration on the sensitivity and linearity was investigated by measuring at wings (248.325, 248.323, 248.321, 248.329, and 248.332 nm) of the main line for Fe at 248.327 nm. For the secondary line at 252.744 nm or side pixel registration at 248.325 nm, main lines for Cu (324.754 nm), Mn (279.482 nm) and Zn (213.875 nm), sample flow-rate of 5.0 mL min−1 and calibration by matrix matching, analytical curves in the 0.2-1.0 mg L−1 Cu, 1.0-20.0 mg L−1 Fe, 0.2-2.0 mg L−1 Mn, 0.1-1.0 mg L−1 Zn ranges were obtained with linear correlations better than 0.998. The proposed method was applied to seven soil samples and two soil reference materials (IAC 277; IAC 280). Results were in agreement at a 95% confidence level (paired t-test) with reference values. Recoveries of analytes added to soil extracts containing 0.15 and 0.30 mg L−1 Cu, 7.0 and 14 mg L−1 Fe, 0.60 and 1.20 mg L−1 Mn, 0.07 and 0.15 mg L−1 Zn, varied within the 94-99, 92-98, 93-101, and 93-103% intervals, respectively. The relative standard deviations (n = 12) were 2.7% (Cu), 1.4% (Fe - 252.744 nm), 5.7% (Fe - 248.325 nm), 3.2% (Mn) and 2.8% (Zn) for an extract containing 0.35 mg L−1 Cu, 14 mg L−1 Fe, 1.1 mg L−1 Mn and 0.12 mg L−1 Zn. Detection limits were 5.4 μg L−1 Cu, 55 μg L−1 Fe (252.744 nm), 147 μg L−1 Fe (248.325 nm), 3.0 μg L−1 Mn and 4.2 μg L−1 Zn.  相似文献   

17.
Laser induced breakdown spectroscopy (LIBS) has been evaluated for the determination of micronutrients (B, Cu, Fe, Mn and Zn) in pellets of plant materials, using NIST, BCR and GBW biological certified reference materials for analytical calibration. Pellets of approximately 2 mm thick and 15 mm diameter were prepared by transferring 0.5 g of powdered material to a 15 mm die set and applying 8.0 tons cm− 2. An experimental setup was designed by using a Nd:YAG laser operating at 1064 nm (200 mJ per pulse, 10 Hz) and an Echelle spectrometer with ICCD detector. Repeatability precision varied from 4 to 30% from measurements obtained in 10 different positions (8 laser shots per test portion) in the same sample pellet. Limits of detection were appropriate for routine analysis of plant materials and were 2.2 mg kg− 1 B, 3.0 mg kg− 1 Cu, 3.6 mg kg− 1 Fe, 1.8 mg kg− 1 Mn and 1.2 mg kg− 1 Zn. Analysis of different plant samples were carried out by LIBS and results were compared with those obtained by ICP OES after wet acid decomposition.  相似文献   

18.
Elemental determinations are usually performed on plant samples for agronomic or environmental studies. Direct solid sampling is possible when electrothermal vaporization (ETV) is used as a method of sample introduction in inductively coupled plasma atomic emission spectrometry (ICP-AES). ETV-ICP-AES was applied for elemental determinations in plant samples. The first application aimed at Cd determinations in very small size plant material samples. Several reference plant materials were used to validate the accuracy of the method. Quality control included the systematic analysis of a reference sample in each batch of unknown samples. The performance of the method in time was illustrated by a control chart. The second application aimed at the content of Si in plant materials. Quantification of Si in plant samples was carried out using samples issued from an inter-laboratory test. Detection limit of 30 μg g− 1 was achieved for Si. In all cases, quantification was accomplished easily by means of aqueous standard solutions deposited on cellulose support.  相似文献   

19.
The use of a so-called trihedral and a T-shaped cross-flow pneumatic nebulizer with dual solution loading for inductively coupled plasma optical emission spectrometry has been studied. By these devices analyte clouds from two solutions can be mixed during the aerosol generation step. For both nebulizers the correction of matrix effects using internal standardization and standard addition calibration in an on-line way was investigated and compared to elemental determinations using a conventional cross-flow nebulizer and calibration with synthetic standard solutions without matrix matching. A significant improvement of accuracy, both for calibration with internal standardization and standard addition, was obtained in the case of four synthetic solutions containing each 40 mmol L− 1 Na, K, Rb and Ba as matrix elements and 300 μg L− 1 Cd, Co, Cr, Cu, Fe, Mn, Ni and Pb as analytes. Calibration by standard addition in the case of dual solution loading has been shown to be very useful in the determination of elements at minor and trace levels in steel and alumina reference materials. The results of analysis for minor concentrations of Cr, Cu and Ni in steel as well as for Ca, Fe, Ga, Li, Mg, Mn, Na, Si and Zn in alumina powder certified reference materials subsequent to sample dissolution were found to be in good agreement with the certificates. Limits of detection were found to be only slightly above those for a conventional cross-flow nebulizer and a precision better than 3% was realized with both novel nebulizers.  相似文献   

20.
A slurry sampling method for the simultaneous determination of hydride forming (As, Bi, Ge, Sb, Se, Sn) and Hg and non-hydride forming (Ca, Fe, Mg, Mn, Zn) elements, without total sample digestion has been developed using the commercial dual-mode sample introduction system (MSIS) coupled with microwave induced plasma optical emission spectrometry (MIP-OES) from biological and environmental reference materials and real samples. The main advantage of this system is its simultaneous determination of elements that form volatile vapor species and elements that do not, without any instrumental changes. Optimization of reaction, nebulization and instrumental conditions was performed to characterize the new system. Slurry concentration up to 4% m/v (particles < 100 μm) prepared in 10% HNO3 containing 100 μL of decanol, by application of ultrasonic agitation, was used with calibration by the standard addition technique. An ultrasonic probe was used to homogenize the slurry in the quartz cup just before its introduction into the reaction/nebulization system; the multimode sample introduction system (MSIS) combines the benefits of nebulization and vapor generation in a single device. Detection limits (LOD, 3σblank, peak area) of 0.07, 0.29, 0.25, 0.10, 0.12, 0.14, 0.11, 0.28, 0.42, 0.02, 0.21 and 0.34 μg g− 1 were obtained for As, Bi, Ge, Sb, Se, Sn, Hg, Ca, Fe, Mg, Mn and Zn, respectively. The relative standard deviations were ca. 10%, adequate for slurry analysis. To test the accuracy, six certified reference materials were analyzed with the analyte concentrations mostly in the μg g− 1 level. Measured concentrations are in satisfactory agreement with certified values for the biological reference materials (LUTS-1, DOLT-2) and environmental reference materials (PACS-1, GWB 07302, NIST 2710, NBS 1633b), all adequate for slurry sampling. The method was successfully applied to the determination of the elements in real samples (coal fly ash, lake sediment, sewage). The method requires small amounts of reagents and reduces contamination and losses.  相似文献   