首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A capillary electrophoretic method for the separation of the enantiomers of both ofloxacin and ornidazole is described. Several parameters affecting the separation were studied, including the type and concentration of chiral selector, buffer pH, voltage and temperature. Good chiral separation of the racemic mixtures was achieved in less than 16 min with resolution factors Rs = 5.45 and 6.28 for ofloxacin and ornidazole enantiomers, respectively. Separation was conducted using a bare fused-silica capillary and a background electrolyte (BGE) of 50 mM H3PO4-1 M tris solution; pH 1.85; containing 30 mg mL−1 of sulfated-β-cyclodextrin (S-β-CD). The separation was carried out in reversed polarity mode at 25 °C, 18 kV, detection wavelength at 230 nm and using hydrodynamic injection for 15 s. Acceptable validation criteria for selectivity, linearity, precision, and accuracy were studied. The limits of detection (LOD) and limits of quantitation (LOQ) of the enantiomers (ofloxacin enantiomer 1 (OF-E1), ofloxacin enantiomer 2 (OF-E2), ornidazole enantiomer 1 (OR-E1) and ornidazole enantiomer 2 (OR-E2)) were (0.52, 0.46, 0.54, 0.89) and (1.59, 1.40, 3.07, 2.70) μg mL−1, respectively. The proposed method was successfully applied to the assay of enantiomers of both ofloxacin and ornidazole in pharmaceutical formulations. The computational calculations for the enantiomeric inclusion complexes rationalized the reasons for the different migration times between the ofloxacin and ornidazole enantiomers.  相似文献   

2.
Chiral separation method development is usually very time-consuming due to the diversity in chemical structures of pharmaceutical drug substances as well as the suitable separation conditions and the problem to choose the appropriate chiral selector. This paper shows capillary zone electrophoresis (CZE) which was developed for chiral separation of a basic compound - rivastigmine (RIV) using 30 cm × 50 μm i.d. polyacrylamide (PAA)-coated fused-silica capillary (effective length 20 cm), amine-modified phosphate buffer of pH 2.5 and sulfated-β-CD (S-β-CD) as chiral selector. Other selected native or derivatized cyclodextrins (CDs) were also tested: β-CD (5, 30 mM), carboxymethyl-β-CD (5, 30 mM), dimethyl-β-CD (15 mM), hydroxypropyl-β-CD (5, 30 mM), hydroxypropyl-α-CD (5, 30 mM) and hydroxypropyl-γ-CD (5, 30 mM). Complete enantiomeric separation of RIV was achieved at 20 kV, 18 °C and detection at 200 nm within 8 min with R.S.D. for the absolute migration time reproducibility of less than 2.1%. Rectilinear calibration range was 5.0-500.0 μM of each enantiomer (r = 0.9994-0.9995). The CZE method proposed was used for the control of chiral purity of pharmaceutically active S-RIV and for the analysis of Exelon caps preparation.  相似文献   

3.
《Analytica chimica acta》2004,507(2):171-178
In the last years, capillary electrophoresis (CE) has gained considerable interest in pharmaceutical laboratories for controlling the chiral purity of drugs. This paper describes a simple and fast method for resolution of propranolol enantiomers by affinity capillary electrophoresis (ACE) using human serum albumin (HSA) as chiral selector. The effect of several experimental variables such as HSA concentration, temperature, chiral selector plug length and addition of organic modifiers, on the separation is evaluated. Complete enantioresolution of R- and S-propranolol was achieved in less than 5 min when the capillary was completely filled with 100 μM HSA solution and the electrophoresis was carried out with 67 mM phosphate buffer (pH 7.4) at 20 kV and 35 °C. Peaks were assigned to each propranolol enantiomer according to their relative affinities to HSA. The proposed method was applied to the analysis of pharmaceutical preparations containing propranolol. Resolution, accuracy, reproducibility, cost and sample throughput of the proposed method make it suitable for quality control of the enantiomeric composition of propranolol in pharmaceuticals.  相似文献   

4.
A capillary electrophoretic method for the separation of the aminoglutethimide (AGT) enantiomers using methylated-β-cyclodextrin (M-β-CD) as chiral selector is described. Several parameters affecting the separation were studied, including the type and concentration of chiral selector, buffer pH, voltage and temperature. Good chiral separation of the racemic mixture was achieved in less than 9 min with resolution factor Rs = 2.1, using a fused-silica capillary and a background electrolyte (BGE) of tris-phosphate buffer solution (50 mmol L−1, pH 3.0) containing 30 mg mL−1 of M-β-CD. The separation was carried out in normal polarity mode at 25 °C, 16 kV and using hydrostatic injection. Acceptable validation criteria for selectivity, linearity, precision, and accuracy/recovery were included. The proposed method was successfully applied to the assay of AGT enantiomers in pharmaceutical formulations. The computational calculations for the inclusion complexes of the R- and S-AGT-M-β-CD rationalized the reasons for the different migration times between the AGT enantiomers.  相似文献   

5.
In this work, a novel methoxypropylamino β-cyclodextrin (β-CD) clicked AC regioisomer, 6A-4-hydroxyethyl-1,2,3-triazolyl-6C-3-methoxypropylamino β-cyclodextrin (HETz-MPrAMCD), was synthesized via nucleophilic addition and click chemistry. The chiral separation ability of this AC regioisomer cationic CD was evaluated toward 7 ampholytic and 13 acidic racemates by capillary electrophoresis. Dependence of enantioselectivity and resolution on buffer pH (5.5–8.0) and chiral selector concentration (0.5–7.5 mM) was investigated. Enantioselectivities (α ≥ 1.05) could be achieved for most analytes under optimal conditions except dansyl-dl-noreleucine and dansyl-dl-serine. The highest resolutions for 2-chloromandelic acid p-hydroxymandelic acid were 15.6 and 9.7 respectively. The inclusion complexation between HETz-MPrAMCD and each 3-phenyllactic acid enantiomer was also revealed with nuclear magnetic resonance study.  相似文献   

6.
Nowadays, there is a special interest within the pharmaceutical laboratories to develop single enantiomer formulations and consequently a need for analytical methods to determine the enantiomeric purity of drugs. The present paper deals with the enantiomeric separation of promethazine and trimeprazine enantiomers by affinity electrokinetic chromatography (AEKC)-partial filling technique using human serum albumin (HSA) as chiral selector. A multivariate optimization of the most critical experimental variables in enantioresolution, running pH, HSA concentration and plug length, is carried out to obtain enantioresolution of promethazine and trimeprazine. The estimated maximum and optimum resolution of trimeprazine and prometazine enantiomers (Rs = 1.74 and 2.01, respectively) corresponded to the following experimental conditions: pH 7.5; [HSA] 170 μM and plug length 190 s and pH 7.6; [HSA] 170 μM and plug length 170 s, for trimeprazine and prometazine, respectively. The developed methodologies were applied for the enantiomeric quality control of promethazine and trimeprazine enantiomers in commercially available pharmaceutical formulations. Resolution, accuracy, reproducibility, cost and sample throughput of the proposed methodologies make it suitable for quality control of the enantiomeric composition of promethazine and trimeprazine in pharmaceutical preparations.  相似文献   

7.
This work concentrates on a chiral separation technology named biphasic recognition applied to resolution of α-cyclohexylmandelic acid enantiomers by high-speed counter-current chromatography (HSCCC). The biphasic chiral recognition HSCCC was performed by adding lipophilic (−)-2-ethylhexyl tartrate in the organic stationary phase and hydrophilic hydroxypropyl-β-cyclodextrin in the aqueous mobile phase, which preferentially recognized the (−)-enantiomer and (+)-enantiomer, respectively. The two-phase solvent system composed of n-hexane-methyl tert-butyl ether–water (9:1:10, v/v/v) with the above chiral selectors was selected according to the partition coefficient and separation factor of the target enantiomers. Important parameters involved in the chiral separation were investigated, namely the types of the chiral selectors (CS); the concentration of each chiral selector; pH of the mobile phase and the separation temperature. The mechanism involved in this biphasic recognition chiral separation by HSCCC was discussed. Langmuirian isotherm was employed to estimate the loading limits for a given value of chiral selectors. Under optimum separation conditions, 3.5–22.0 mg of α-cyclohexylmandelic acid racemate were separated using the analytical apparatus and 440 mg of racemate was separated using the preparative one. The purities of both of the fractions including (+)-enantiomer and (−)-enantiomer from the preparative CCC separation were over 99.5% determined by HPLC and enantiomeric excess reached 100% for the (±)-enantiomers. Recovery for the target compounds from the CCC fractions reached 85–88% yielding 186 mg of (+)-enantiomer and 190 mg of (−)-enantiomer. The overall experimental results show that the HSCCC separation of enantiomer based on biphasic recognition, in which only if the CSs involved will show affinity for opposite enantiomers of the analyte, is much more efficient than the traditional monophasic recognition chiral separation, since it utilizes the cooperation of both of lipophilic and hydrophilic chiral selectors.  相似文献   

8.
Liquid chromatography (LC)/tandem mass spectrometry (MS/MS) after supramolecular solvent-based microextraction (SUSME) was firstly used in this work for the enantioselective determination of chiral pesticides in natural waters. The method developed for the quantitation of the R- and S-enantiomers of mecoprop (MCPP) and dichlorprop (DCPP) involved the extraction of the herbicides in a supramolecular solvent (SUPRAS) made up of reverse aggregates of dodecanoic acid (DoA), analyte re-extraction in acetate buffer (pH = 5.0), separation of the target enantiomers on a chiral column of permethylated α-cyclodextrin under isocratic conditions, and detection of the daughter ions (m/z = 140.9 and 160.6 for MCPP and DCPP, respectively) using a hybrid triple quadrupole mass spectrometer equipped with an electrospray source operating in the negative ion mode. Similar recoveries (ca. 75%) and actual concentration factors (ca. 94) were obtained for both phenoxypropanoic acids (PPAs). The quantitation limits were 1 ng L−1 for R- and S-MCPP, and 4 ng L−1 for R- and S-DCPP, and the precision, expressed as relative standard deviation (n = 6) was in the ranges 2.4–2.7% ([R-MCPP] = [S-MCPP] = 5 ng L−1 and [R-DCPP] = [S-DCPP] = 15 ng L−1) and 1.6–1.8% (100 ng L−1 of each enantiomer). The SUSME-LC–MS/MS method was successfully applied to the determination of the enantiomers of MCPP and DCPP in river and underground waters, fortified at concentrations between 15 and 180 ng L−1 at variable enantiomeric ratios (ER = 1–9).  相似文献   

9.
Zhao S  Song Y  Liu YM 《Talanta》2005,67(1):212-216
A capillary electrophoresis method has been developed for the determination of d-serine in neural samples. d/l-serine was tagged with naphthalene-2,3-dicarboxaldehyde (CBI-d/l-Ser), and the separation of CBI-d/l-Ser enantiomer was achieved by using a dual chiral selector system consisting of β-cyclodextrin (β-CD) and chiral micelles formed by sodium deoxycholate (SDC). No resolution was observed when either β-CD or SDC was used alone. Moreover, the combined use of β-CD with achiral micelles of sodium dodecylsulfate (SDS) exhibited no resolving effect. With laser induced fluorescence detection, the limit of detection was 3.0 × 10−8 M Ser. Under the separation conditions selected, no other amino acids co-eluted with l-/d-Ser enantiomers. Using the present method, d-Ser level in Aplysia ganglia homogenates was found to vary significantly from animal to animal. Interestingly, d-Ser was not detected in single neurons isolated from Aplysia ganglia.  相似文献   

10.
Zeng HL  Li HF  Wang X  Lin JM 《Talanta》2006,69(1):226-231
A β-cyclodextrin (β-CD)-bonded gel monolithic column polydimethylsiloxane (PDMS) microfluidic device was developed in a simple and feasible way. Before preparation of gel monolithic column in PDMS microchannel, PDMS surface was activated by UV light to create silanol groups, which is an active molecule to covalently bond 3-(trimethoxysilyl)-propyl methacrylate (Bind-Silane) and seal microfluidic device. By the way, Bind-Silane is a bifunctional molecule to link polyacrylamide (PAA) gel and inner wall of PDMS microchannel covalently. Allyl-β-CD was used not only as a multifunctional crosslinker in PAA gel to control the size of the pores, but also as a chiral selector for the enantioseparation. The stability, transferring heat and optical characteristic of the microfluidic device were examined. The separation capability of the gel monolithic column was confirmed by the successful separation of fluorescein isothiocyanate (FITC)-labeled arginine (Arg), glutamine acid (Glu), tryptophan (Try), cysteine (Cysteine) and phenylalanine (Phe) in the PDMS microfluidic device less than 100 s at 36 mm effective separation length. A maximum of 2.06 × 105 theoretical plates was obtained by the potential strength of 490 V/cm. A pair of FITC-labeled dansyl-d,l-threonine (Dns-Thr) was separated absolutely.  相似文献   

11.
We describe the stacking and separation of d- and l-aspartic acid (Asp) by capillary electrophoresis (CE) with light-emitting diode-induced fluorescence detection (LEDIF). In the presence of cyanide, d- and l-Asp were derivatized with naphthalene-2,3-dicarboxaldehyde (NDA) to form fluorescent derivatives prior to CE-LEDIF. The separation of NDA-derivatized d- and l-Asp was accomplished using a discontinuous system - buffer vials contained a solution of 0.6% poly(ethylene oxide) (PEO), 150 mM sodium dodecyl sulfate (SDS), and 60 mM hydroxypropyl-β-cyclodextrin (Hp-β-CD), while a capillary was filled with a solution of 150 mM SDS and 60 mM Hp-β-CD. The role of PEO, Hp-β-CD, and SDS is to act as a concentrating media, as a chiral selector, and as a pseudostationary phase, respectively. This discontinuous system could be employed for the stacking of 600 nL of NDA-derivatized d- and l-Asp without the loss of chiral resolution. The stacking mechanism is mainly based on the difference in viscosity between sample zone and PEO as well as SDS sweeping. The limits of detection at signal-to-noise of 3 for d- and l-Asp were down to 2.4 and 2.5 × 10−10 M, respectively. Compared to normal sample injection volume (25 nL), this stacking approach provided a 100- and 110-fold improvement in the sensitivity of d- and l-Asp, respectively. This method was further applied for determining d- and l-Asp in cerebrospinal fluid, soymilk, and beer.  相似文献   

12.
Haroun M  Ravelet C  Grosset C  Ravel A  Villet A  Peyrin E 《Talanta》2006,68(3):1032-1036
In this paper, two chiral stationary phases were prepared by coating the surface of both C8 and C18 high-performance liquid chromatography (HPLC) supports with the teicoplanin chiral selector. The hydrophobic C11 acyl side chain, attached to the d-glucosamine group of teicoplanin, served as anchor moiety for the immobilization of the chiral selector on the apolar support material. The retention and enantioselectivity of these coated stationary phases were studied using some aromatic amino acids as probe solutes and an aqueous solution as mobile phase. It was found that the enantiomer elution order on the modified C8 and C18 stationary phases was reversed (l > d) relatively to that classically observed with a teicoplanin covalently immobilized on a silica support (d > l). Such a dynamic coating on the reversed-phase supports was found to be of interest since the apparent enantioselectivity was not significantly changed by the use during an extended period of time or following a long-term storage of the columns.  相似文献   

13.
The chiral resolving ability of a novel single-isomer cationic β-cyclodextrin (CD), mono-6A-propylammonium-6A-deoxy-β-cyclodextrin chloride (PrAMCD), as a chiral selector in capillary electrophoresis (CE) is reported in this work for the enantioseparation of hydroxy, carboxylic acids and amphoteric analytes. The effect of chiral selector concentration on the resolution was studied. Good resolutions were achieved for hydroxy acids. Optimum resolutions were obtained even at 3.5 mM CD concentration for carboxylic acids. The electrophoretic method showed good linearity and reproducibility in terms of migration times and peak areas, which should make it suitable for routine analysis. In addition, baseline chiral separation of a six-acid mixture was achieved within 20 min. PrAMCD proved to be an effective chiral selector for acidic analytes.  相似文献   

14.
The enantiomer separation of a number of racemic 7‐[(1‐alkylpiperidin‐3‐yl)methoxy]coumarin derivatives, some of which show outstanding in vitro multitarget neuroprotective activities, was successfully achieved on a polysaccharide‐based chiral stationary phase, bearing amylose tris(3,5‐dimethylphenylcarbamate) as a chiral selector, in normal polar mode (methanol and acetonitrile as the mobile phases). The majority of the screened selectands, especially those bearing 1‐(3‐X‐benzyl)piperidin‐3‐yl moieties, showed baseline enantiomer separations, and compound 8 (X = NO2) was the best resolved (α = 2.01; RS = 4.27). Linear free energy relationships, usefully complemented by molecular docking calculations, have the key role in enantioselective retention of aromatic interactions between π‐donor moieties in the chiral selector and π‐acceptor moieties in selectand, strengthened by hydrogen bond interaction between a hydrogen bond donor in the chiral selector and the hydrogen bond acceptor group(s) in the selectand. Statistically, reliable equations highlighted the importance of the substituent's size and substitution pattern (meta better than para) to affect the enantiorecognition of the title compounds. The chromatographic data support the scalability of the optimized experimental conditions for preparative purposes.  相似文献   

15.
A capillary electrophoresis for the chiral separation of racemic methotrexate (rac-MTX) was developed and validated. The two enantiomers were separated by using fused-silica capillary and a running buffer containing phosphate and hydroxypropyl-β-cyclodextrin (HP-β-CD). Several parameters were studied, including concentration and pH of phosphate buffer, separation voltage, and type and concentration of CD. The quantitative ranges were 12.5-200.0 μM for each enantiomer. The intra- and inter-day relative standard deviations (R.S.D.) and relative errors (R.E.) (n=5) were all <5%. The detection limits were found to be about 4 μM (S/N=3, injection 5 s) at 280 nm. All recoveries were greater than 93%. This method was applied to the assay of l-MTX in pharmaceuticals.  相似文献   

16.
Chen JL 《Talanta》2011,85(5):2330-2338
The chiral selector, chitosan (CS), was attached to the silanized capillary via a silane coupling agent, (3-glycidyloxypropyl)trimethoxysilane (GTS), to form the GTS-CS capillary, and results for this capillary were compared with those of a previous study on the copolymerization of CS with methacrylamide (MAA) (forming the MAA-CS capillary). The GTS-CS capillary did not exhibit enantioselectivity for d/l-tryptophan, whereas the GTS-BSA capillary, which was prepared by replacement of CS with bovine serum albumin (BSA), succeeded in the chiral separation with an Rs = 2.4 in Tris buffer (50 mM, pH 8.5). To increase CS attachment, the CS units were crosslinked by succinic acid, and the resulting GTS-CS-s capillary phase improved the resolution to 1.9. Alternatively, the SiH-CS-s capillary was constructed by CS attachment on the silicon hydride phase via stepwise silanization and hydrosilation reactions and crosslinking by succinic acid, but this approach could only achieve a resolution of 1.4 in Tris buffer (50 mM, pH 9.5). Although the GTS-CS-s and SiH-CS-s capillaries were still inferior to the MAA-CS capillary (Rs = 3.8), the enantioselectivities of the three capillaries were all in the range of 1.4-1.6. For the (±)-catechin sample, the plate heights of the GTS-CS-s and SiH-CS-s capillaries conditioned in pH 8.5 Tris buffer with 60% MeOH modifier were 0.9 cm ((−)-catechin) and 6.0 cm ((+)-catechin)) and 2.9 cm (−) and 3.2 cm (+), respectively, and these heights were comparable to the MAA-CS capillary (2.5 cm (−), 6.0 cm (+)) in pH 6.6 phosphate buffer with 80% MeOH. Finally, a racemate of ibuprofen, a weakly acidic anti-inflammatory drug, was successfully baseline resolved by the GTS-CS-s and SiH-CS-s capillaries in the borate buffers, which were 30 mM at pH 7.5 and 10 mM at pH 8.0, respectively.  相似文献   

17.
Liquid chromatographic comparisons for enantiomer resolution of α-amino acids and chiral primary amino compounds were made using chiral stationary phases (CSPs) prepared by covalently bonding (+)-(18-crown-6)-2,3,11,12-tetracarboxylic acid (18-C-6-TA) of the same chiral selector. The resolution of all α-amino acids on CSP 1 developed in our group was found to be better than that on CSP 2 reported by Machida et al. All α-amino acids examined in this study were well enantioseparated on CSP 1 (α=1.22–2.47), while four analytes were not resolved or all the other analytes were poorly resolved on CSP 2 than on CSP 1. However, in resolving the primary amino compounds without a carbonyl group, CSP 1 was comparable with CSP 2. Although (+)-18-C-6-TA of the same chiral selector was used to prepare CSP 1 and CSP 2, this study showed that different connecting methods for the CSPs might influence their ability to resolve the analytes depending on their structures related to the chiral recognition mechanism.  相似文献   

18.
A new capillary zone electrophoresis (CZE) method for the separation of omeprazole enantiomers has been developed. Methyl-β-cyclodextrin (methyl-β-CD) was chosen as the chiral selector, and several parameters, such as cyclodextrin structure and concentration, buffer concentration, pH, and capillary temperature were investigated in order to optimize separation and run times. Analysis times, shorter than 8 min were found using a background electrolyte solution consisting of 40 mM phosphate buffer adjusted to pH 2.2, 30 mM β-cyclodextrin and 5 mM sodium disulphide, hydrodynamic injection, and 15 kV separation voltage. Detection limits were evaluated on the basis of baseline noise and were established 0.31 mg/l for the omeprazole enantiomers. The proposed method was applied to five pharmaceutical preparations with recoveries between 84 and 104% of the labeled contents.  相似文献   

19.
(Liquid + liquid) equilibrium (LLE) data for the ternary system of (water + butyric acid + oleyl alcohol) at T = (298.15, 308.15, and 318.15) K are reported. Complete phase diagrams were obtained by determining solubility and the tie-line data. The reliability of the experimental tie lines was confirmed by using Othmer-Tobias correlation. The UNIFAC method was used to predict the phase equilibrium data. The phase diagrams for the ternary mixtures including both the experimental and correlated tie lines are presented. Distribution coefficients and separation factors were evaluated for the immiscibility region. A comparison of the solvent extracting capability was made with respect to distribution coefficients, separation factors, and solvent-free selectivity bases for T = (298.15, 308.15, and 318.15) K. It is concluded that oleyl alcohol may serve as an adequate solvent to extract butyric acid from its dilute aqueous solutions.  相似文献   

20.
A simple accurate method for determining amino acid composition of wheat gluten proteins and their gliadin and glutenin fractions using high-performance anion-exchange chromatography with integrated pulsed amperometric detection is described. In contrast to most conventional methods, the analysis requires neither pre- or post-column derivatization, nor oxidation of the sample. It consists of hydrolysis (6.0 M hydrochloric acid solution at 110 °C for 24 h), evaporation of hydrolyzates (110 °C), and chromatographic separation of the liberated amino acids. Correction factors (f) accounted for incomplete cleavage of peptide bonds involving Val (f = 1.07) and Ile (f = 1.13) after hydrolysis for 24 h and for Ser (f = 1.32) losses during evaporation. Gradient conditions including an extra eluent (0.1 M acetic acid solution) allowed multiple sequential sample analyses without risk of Glu contamination on the anion-exchange column. While gluten amino acid compositions by the present method were mostly comparable to those obtained by a conventional method involving oxidation, acid hydrolysis and post-column ninhydrin derivatization, the latter method underestimated Tyr, Val and Ile levels. Results for the other amino acids obtained by the different methods were linearly correlated (r > 0.99, slope = 1.03).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏