首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 16 毫秒
1.
A new synthesized modified mesoporous silica (MCM-41) using 5-nitro-2-furaldehyde (fural) was applied as an effective sorbent for the solid phase extraction of uranium(VI) and thorium(IV) ions from aqueous solution for the measurement by inductively coupled plasma optical emission spectrometry (ICP OES). The influences of some analytical parameters on the quantitative recoveries of the analyte ions were investigated in batch method. Under optimal conditions, the analyte ions were sorbed by the sorbent at pH 5.5 and then eluted with 1.0 mL of 1.0 mol L−1 HNO3. The preconcentration factor was 100 for a 100 mL sample volume. The limits of detection (LOD) obtained for uranium(VI) and thorium(IV) were 0.3 μg L−1. The maximum sorption capacity of the modified MCM-41 was found to be 47 and 49 mg g−1 for uranium(VI) and thorium(IV), respectively. The sorbent exhibited good stability, reusability, high adsorption capacity and fast rate of equilibrium for sorption/desorption of uranium and thorium ions. The applicability of the synthesized sorbent was examined using CRM and real water samples.  相似文献   

2.
A new functionalized mesoporous silica (MCM-41) using salicylaldehyde was utilized for the separation, preconcentration and determination of uranium in natural water by inductively coupled plasma atomic emission spectrometry (ICP-AES).Experimental conditions for effective adsorption of trace levels of U(VI) were optimized. The preconcentration factor was 100 (1.0 mL of elution for a 100 mL sample volume). The analytical curve was linear in the range 2-1000 μg L−1 and the detection limit was 0.5 ng mL−1. The relative standard deviation (R.S.D.) under optimum conditions was 2.5% (n = 10). Common coexisting ions did not interfere with the separation and determination of uranium at pH 5. The sorbent exhibited excellent stability and its sorption capacity under optimum conditions has been found to be 10 mg of uranium per gram of sorbent. The method was applied for the recovery and determination of uranium in different water samples.  相似文献   

3.
Liu Y  Liang P  Guo L 《Talanta》2005,68(1):25-30
Nanometer titanium dioxide immobilized on silica gel (immobilized nanometer TiO2) was prepared by sol-gel method and characterized by using X-ray diffraction (XRD) and scanning electron microscope (SEM). The adsorptive potential of immobilized nanometer TiO2 for the preconcentration of trace Cd, Cr, Cu and Mn was assessed in this work. The metal ions studied can be quantitative retained at a pH range of 8-9, and 0.5 mol L−1 HNO3 was sufficient for complete elution. The adsorption capacity of immobilized nanometer TiO2 for Cd, Cr, Cu and Mn was found to be 2.93, 2.11, 6.69 and 2.47 mg g−1, respectively. A new method using a microcolumn packed with immobilized nanometer TiO2 as sorbent has been developed for the preconcentration of trace amounts of Cd, Cr, Cu and Mn prior to their determination by inductively coupled plasma atomic emission spectrometry (ICP-AES). The method has been successfully applied for the determination of trace elements in some environmental samples with satisfactory results.  相似文献   

4.
A modified SBA-15 mesoporous silica material NH2-SBA-15 was synthesized successfully by grafting γ-aminopropyl-triethoxysilane. The material was characterized using transmission electron microscopy (TEM) and Fourier transform infrared/Raman (FT-IR/Raman) spectroscopy, and used for the first time in a flow injection on-line solid phase extraction (SPE) coupled with flame atomic absorption spectrometry (FAAS) to detect trace Cr (VI). Effective sorption of Cr (VI) was achieved at pH 2.0 with no interference from Cr (III) and other ions and 0.5 mol L−1 NH3·H2O solution was found optimal for the complete elution of Cr (VI). An enrichment factor of 44 and was achieved under optimized experimental conditions at a sample loading of 2.0 mL min−1 sample loading (300 s) and an elution flow rate of 2.0 mL min−1 (24 s). The precision of the 11 replicate Cr (VI) measurements was 2.1% at the 100 μg L−1 level with a detection limit of 0.2 μg L−1 (3 s, n = 10) using the FAAS. The developed method was successfully applied to trace chromium determination in waste water. The accuracy was validated using a certified reference material of riverine water (GBW08607).  相似文献   

5.
The present article reports on the application of modified multiwalled carbon nanotubes (MMWCNTs) as a new, easily prepared and stable solid sorbent for the preconcentration of trace rhodium ion in aqueous solution. Rhodium ions were complexed with 1-(2-pyridylazo)-2-naphthol (PAN) in the pH range of 3.2-4.7 and then the formed Rh-PAN complex was adsorbed on the oxidized MWCNTs. The adsorbed complex was eluted from MWCNTs sorbent with 5.0 mL of N,N-dimethylformamide (DMF). The rhodium in eluted solution was determined by flame atomic absorption spectrometry (FAAS). Linear range for the determination of rhodium was maintained between 0.16 ng mL−1 and 25.0 μg mL−1 in initial solution. Relative standard deviation for the 10 replicated determination of 4.0 μg mL−1 of rhodium was ±0.97%. Detection limit was 0.010 ng mL−1 in initial solution (3Sbl, n = 10) and preconcentration factor was 120. Sensitivity for 1% absorbance of rhodium (III) was 0.112 μg mL−1. The sorption capacity of oxidized MWCNTs for Rh (III) was 6.6 mg g−1. The effects of the experimental parameters, including the sample pH, flow rates of sample and eluent solution, eluent type, breakthrough volume and interference ions were studied for the preconcentration of Rh3+. The proposed method was successfully applied to the extraction and determination of rhodium in different samples.  相似文献   

6.
In this research a new physically functionalized nanoporous silica (SBA-15) using N′-[(2-hydroxy phenyl) methylene] benzohydrazide (BBH) was utilized as a selective sorbent for the separation, preconcentration and determination of dysprosium (Dy) in natural water by inductively coupled plasma optical emission spectrometry (ICP-OES). The selectivity of BBH to Dy (III) ion was previously tested by conductometric and spectroscopic methods. Conditions for effective adsorption of Dy were optimized with respect to experimental parameters in batch process. The extraction recovery was 96.5, analytical curve was linear in the range 0.2–1000?µgL?1, and the detection limit was 0.05?ng?mL?1. The relative standard deviation (RSD) under optimal conditions was 3.2% (n?=?10). The sorbent exhibited high adsorption capacity and fast rate of equilibrium for sorption of Dy ions. The method was applied for recovery and determination of dysprosium in different environmental water samples.  相似文献   

7.
Wu XZ  Liu P  Pu QS  Sun QY  Su ZX 《Talanta》2004,62(5):918-923
A amino-terminated G 4.0 dendrimer-like polyamidoamine (PAMAM) immobilized silica gel (PAMAMSG) was prepared with a divergent method by repeating two processes: (1) Michael addition of methyl acrylate (MA) to surface amino groups; and (2) amidation of the resulting esters with ethylenediamine (EDA) from γ-aiminopropyl silica gel (APSG) core. It was then used for the first time as microcolumn packing for the flame atomic absorption spectrometry (FAAS) determination of trace or ultra trace Pd(II), after flow injection (FI) online preconcentration and separation process. A limit of detection (LOD) of 3.9 ng ml−1 was achieved when 0.200 μg ml−1 Pd(II) was preconcentrated in 0.2 mol l−1 HCl medium with a sampling flow rate of 6.0 ml min−1 for 60 s and the relative standard deviation (R.S.D.) was 1.7%. The proposed method was successfully used for the determination of Pd in two metallurgical samples.  相似文献   

8.
A simple and sensitive method has been developed for the trace determination of bismuth in aqueous samples by a combination of solid‐phase extraction and hydride generation atomic absorption spectrometry. The method is based on the use of a column packed with 2‐mercaptobenzothiazole immobilized on sodium dodecyl sulfate coated alumina. Different parameters influencing the separation and preconcentration of bismuth such as pH, sample volume, type, and concentration of eluent, and the flow rate of sample and eluent were studied. A sample volume of 500.0 mL resulted in a preconcentration factor of 100. The precision (relative standard deviation, N = 10) at the 300 ng/L level and the limit of detection (3s) were found to be 2.3% and 12 ng/L, respectively. The developed method was successfully applied to the determination of bismuth in natural water samples and two certified reference materials.  相似文献   

9.
A new method using a microcolumn packed with nanometer TiO2 as solid-phase extractant has been developed for the simultaneous preconcentration of trace amounts of Cu, Mn, Cr and Ni prior to their measurements by inductively coupled plasma atomic emission spectrometry (ICP-AES). Effects of pH, sample flow rate and volume, elution solution and interfering ions on the recovery of the analytes have been investigated. The adsorption capacity of nanometer TiO2 was found as 0.108, 0.149, 0.039 and 0.034 mmol g−1 for Cu, Cr, Mn and Ni, respectively. The separation of analytes can be achieved from water samples with a concentration factor of 50 times. The method has been applied for the determination of trace elements in biological sample and lake water with satisfactory results.  相似文献   

10.
An ion-exchange procedure is proposed for determination of Pt and Pd in environmental samples, using a Dowex 1-X10 anion-exchange resin. Pt and Pd were separated from the matrix elements in the sample by selective retention on the column as anionic chloro complexes and subsequent elution by circulated thiourea at 60 °C. The eluent, containing Pt and Pd was analyzed by inductively coupled plasma (ICP) atomic emission spectrometry (AES). Average recoveries of 98% and detection limit of 15 ng/g for both metals were achieved. Analysis of Pt and Pd concentrations in road dust, sampled from several sites in Germany was performed. The comparison of the obtained data with the concentrations of Pt and Pd in the same samples, determined by ICP-MS showed a very good agreement.  相似文献   

11.
A simple and effective method is presented for the separation and preconcentration of thorium(IV) and uranium(VI) by solid phase extraction on Duolite XAD761 adsorption resin. Thorium(IV) and uranium(VI) 9-phenyl-3-fluorone chelates are formed and adsorbed onto the Duolite XAD761. Thorium(IV) and uranium(VI) are quantitatively eluted with 2 mol L−1 HCl and determined by inductively coupled plasma-mass spectrometry (ICP-MS). The influences of analytical parameters including pH, amount of reagents, amount of Duolite XAD761 and sample volume, etc. were investigated on the recovery of analyte ions. The interference of a large number of anions and cations has been studied and the optimized conditions developed have been utilized for the trace determination of uranium and thorium. A preconcentration factor of 30 for uranium and thorium was achieved. The relative standard deviation (N = 10) was 2.3% for uranium and 4.5% for thorium ions for 10 replicate determinations in the solution containing 0.5 μg of uranium and thorium. The three sigma detection limits (N = 15) for thorium(IV) and uranium(VI) ions were found to be 4.5 and 6.3 ng L−1, respectively. The developed solid phase extraction method was successively utilized for the determination of traces thorium(IV) and uranium(VI) in environmental samples by ICP-MS.  相似文献   

12.
The usage of a variety of sorbents has been shown as promising matrix removal/preconcentration strategies for the determination of rare earth elements (REEs) in various natural water samples by inductively coupled plasma atomic emission spectrometry (ICP-AES). The sorption efficiency of various zeolites (clinoptilolite, mordenite, zeolite Y, zeolite Beta), ion-exchangers (Amberlite CG-120, Amberlite IR-120, Rexyn 101, Dowex 50W X18) and chelating resins (Muromac, Chelex 100, Amberlite IRC-718) towards REEs was investigated in terms of solution pH, shaking time and sorbent amount. The results have shown that most of the materials can take up REEs at a wide pH range. The experiments were continued with clinoptilolite, zeolite Y and Chelex 100 and it was demonstrated that all three materials displayed very fast kinetics for REE sorption (higher than 96% in 1 min). Desorption from the sorbents was realized with 2.0 M HNO3 for clinoptilolite and 0.1 M HNO3 for zeolite Y and Chelex 100. Only the lower concentration range (0.01-2.0 mg l−1) of matrix-matched standards were used in quantitation although the calibration graphs were linear at least up to 10.0 mg l−1 for all REEs studied. The limit of detection (3 s) without preconcentration was 0.1, 1.0, and 0.2 μg l−1 for Eu, La, and Yb, respectively. The validity of the method with the selected sorbents was checked through spike recovery experiments.  相似文献   

13.
A preconcentration method based on third phase extraction has been developed and combined with inductively coupled plasma atomic emission spectrometry (ICP-AES) for determination of Sb, Pb, Tl at trace levels in water samples. The reagents diantipyrylmethane and potassium iodide were applied for complexing Sb, Pb, Tl and producing a third phase extraction system. This third phase system produces relatively large enrichment factors and complete isolation of trace elements from high salt-containing matrices which influence strongly the plasma condition. Experimental parameters of the extraction, such as concentrations of complexing reagents, pH and extraction time have been optimized. Under the selected conditions, this third phase ICP-AES combination procedure gave multielemental detection limits for Sb, Pb, Tl which are superior by an order of magnitude or more to those obtained by ICP-AES alone without preconcentration. Precision of the technique is better than 10% at the 10 g/l level. The accuracy of this approach is demonstrated by its application to tapwater, artificial seawater and reference seawater samples.  相似文献   

14.
A method for on-line preconcentration of palladium at ultra-trace level on alumina microcolumns and determination by inductively coupled plasma mass spectrometry (ICP-MS) has been developed. A sampling time of 10 min (30 ml) and an eluent (KCN) volume of 300 μl provides a limit of detection of 1 ng l−1. The precision was 4% at the 25 ng l−1 level. The proposed system allows the on-line removal of the primary interferents (Cu and Y) providing the credible accuracy of the results. The proposed method is suitable for palladium determination in urban water samples. Platinum concentration in the analysed urban water samples was also determined.  相似文献   

15.
Xiong C  He M  Hu B 《Talanta》2008,76(4):772-779
A new, simple, and selective method has been presented for the separation and preconcentration of inorganic arsenic (As(III)/As(V)) and selenium (Se(IV)/Se(VI)) species by a microcolumn on-line coupled with inductively coupled plasma-optical emission spectrometry (ICP-OES). Trace amounts of As(V) and Se(VI) species were separated and preconcentrated from total As and Se at desired pH values by a conical microcolumn packed with cetyltrimethylammonium bromide (CTAB)-modified alkyl silica sorbent in the absence of chelating reagent. The species adsorbed by CTAB-modified alkyl silica sorbent were quantitatively desorbed with 0.10 ml of 1.0 mol l−1 HNO3. Total inorganic arsenic and selenium were similarly extracted after oxidation of As(III) and Se(IV) to As(V) and Se(VI) with KMnO4 (50.0 μmol l−1). The assay of As(III) and Se(IV) were based on subtracting As(V) and Se(VI) from total As and total Se, respectively. All parameters affecting the separation/preconcentration of As(V) and Se(VI) including pH, sample flow rate and volume, eluent solution and volume have been studied. With a sample volume of 3.0 ml, the sample throughput was 24 h−1 and the enrichment factors for As(V) and Se(VI) were 26.7 and 27.6, respectively. The limits of detection (LODs) were 0.15 μg l−1 for As(V) and 0.10 μg l−1 for Se(VI). The relative standard deviations (RSDs) for nine replicate determinations at 5.0 μg l−1 level of As(V) and Se(VI) were 4.0% and 3.6%, respectively. The calibration graphs of the method for As(V) and Se(VI) were linear in the range of 0.5–1000.0 μg l−1 with a correlation coefficient of 0.9936 and 0.9992, respectively. The developed method was successfully applied to the speciation analysis of inorganic arsenic and selenium in natural water samples with satisfactory results.  相似文献   

16.
Fan Z 《Talanta》2006,70(5):1164-1169
Hg(II)-imprinting thiol-functionalized mesoporous sorbent was prepared by a sol–gel method and characterized by X-ray diffraction (XRD), FT-IR spectroscopy and nitrogen gas adsorption–desorption. The static adsorption capacity of the Hg(II)-imprinted and non-imprinted sorbent was 78.5 and 26.6 mg g−1, respectively. The breakthrough capacity was 4.46 mg g−1, and the relative selectivity coefficient for Hg(II) in the presence of Cd and Pb was 3.3 and 3.9, respectively. A new method using a micro-column packed with Hg(II)-imprinting thiol-functionalized mesoporous sorbent has been developed for preconcentration of trace mercury prior to its determination by inductively coupled plasma optical emission spectrometry (ICP-OES). The effects of pH, sample flow rate and volume, elution solution and interfering ions on the recovery of the analyte have been investigated. The limit of detection was 0.39 ng ml−1 with a concentration factor of 150 times. The developed method has been applied to the determination of trace mercury in some biological and environmental samples with satisfactory results. The accuracy was assessed through recovery experiments and analysis of certified reference material.  相似文献   

17.
A simple and highly selective flow injection (FI) on-line preconcentration and separation flame atomic absorption spectrometric (FAAS) method was developed for the determinations of trace amounts of silver, gold and palladium. The selective preconcentration of the noble metals was achieved in a wide range of sample acidity (0.1-6 M HNO3 or HCl) on a microcolumn packed with amidinothioureido-silica gel (ATuSG). The analytes retained on the column were effectively eluted with 5.0% thiourea solution. The analytical procedure was optimized for sample acidity, elution, interferences, flow rate of sampling and eluting, and concentration of sample. Common co-existing cations and anions did not interfere with the preconcentration and determination of the three metals. At a sample loading flow rate of 4.5 ml min−1 with 60 s preconcentration, detection limits (3σ) of 1.1 ng ml−1 Ag, 13 ng ml−1 Au and 17 ng ml−1 Pd were obtained. The precisions (R.S.D., n=11) were 1.2% for Ag, 1.2% for Au and 1.7% for Pd, respectively. The detection limits can be further improved by increasing sample volume. The analytical results obtained by the proposed method for a number of standard reference materials were in good agreement with the certified values.  相似文献   

18.
Highly ordered adsorbent mesoporous silica (MCM-41) was synthesised using a rapid method and its subsequent chemical modification with 3-mercaptopropyltrimethoxysilane (MPTMS) in toluene medium at 60°C was performed. The electro-reduction product of 4-nitrophenol (EP4NP), as a new kind of polyaminophenol-type chelating agent with a high affinity to Ni(II), was then incorporated into MPTMS-MCM-41. The resulting materials (MCM-41, MPTMS-MCM-41 and EP4NP-MPTMS-MCM-41) were characterised by scanning electron microscopy, powder X-ray diffraction, nitrogen gas sorption and Fourier transform-infrared spectrometry. The new modified adsorbent EP4NP-MPTMS-MCM-41 was then employed for preconcentration of ultra-trace amounts of Ni(II) by dispersive micro solid phase extraction prior to inductively coupled plasma-optical emission spectrometry. The effects of variables such as pH, mass of the chelating agent, the amount of EP4NP-MPTMS-MCM-41, stirring time of extraction step, HCl concentration and stirring time during elution were optimised and the calibration curve was plotted. The limits of detection and quantitation were 0.006 and 0.019 μg L?1, respectively. The mean, standard error and relative standard deviation for five replicates of 0.5 μg L?1 Ni(II) were calculated to be 0.48 μg L?1, 4.0% and 3.2%, respectively. The proposed method was successfully applied for determination of Ni(II) in wastewater samples.  相似文献   

19.
Rojas FS  Ojeda CB  Pavón JM 《Talanta》2006,70(5):979-983
A flow injection (FI) system was used to develop an efficient on-line sorbent extraction preconcentration system for palladium by graphite furnace atomic absorption spectrometry (GFAAS). The investigated metal was preconcentrated on a microcolumn packed with 1,5-bis(di-2-pyridyl)methylene thiocarbohydrazide immobilized on silica gel (DPTH-gel). The palladium is eluted with 40 μl of HCl 4 M and directly introduced into the graphite furnace. The detection limit for palladium under the optimum conditions was 0.4 ng ml−1. This procedure was employed to determine palladium in different samples.  相似文献   

20.
A method for solid phase extraction of trace metals such as Cd2+, Cr6+, Cu2+, Fe3+, Mn2+, Ni2+, Pb2+ and Zn2+ using nanometer-sized alumina coated with chromotropic acid prior to determination by inductively coupled plasma atomic emission spectrometry (ICP-AES) has been developed. Various influencing parameters on the separation and preconcentration of trace metals, pH, flow rate, sample volume, amount of adsorbent, concentration of eluent and sorption kinetics have been studied. The detection limits for Cd2+, Cr6+, Cu2+, Fe3+, Mn2+, Ni2+, Pb2+ and Zn2+ were found to be 0.14, 0.62, 0.22, 0.54, 0.27, 0.28, 0.53 and 0.38 ng ml− 1, respectively. The adsorption capacity of the solid phase adsorption material is 10.3, 11.3, 14.5, 16.4, 15.1, 11.7, 15.4 and 16.8 mg g− 1 for Cd2+, Cr6+, Cu2+, Fe3+, Mn2+, Ni2+, Pb2+ and Zn2+, respectively. The preconcentration factor was obtained in the range of 50-100 for all studied metal ions. Coexisting ions over a high concentration range have not shown any significant effects on the determination of aforesaid metal ions. The accuracy of the proposed method was tested by standard reference materials (NIST 1643e: water, NIST 1573a: tomato leaves and NIST 1568a rice flour) and natural waters and the results obtained were in good agreement with the certified values.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号