首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
We have developed and validated a simple detection system with high-performance liquid chromatography (HPLC) with positive ion electrospray ionization tandem mass spectrometry (ESI-MS/MS) for determining cimetropium levels in human plasma using scopolamine butyl bromide as an internal standard (I.S.). The acquisition was performed in the multiple reaction monitoring (MRM) mode, by monitoring the transitions: m/z 357.9 > 103.1 for cimetropium and m/z 359.9 > 103.1 for butyl-scopolamine. The method involves a simple single-step liquid-liquid extraction with dichloromethane. The analyte was chromatographed on an YMC C18 reversed-phase chromatographic column by isocratic elution with 10 mM ammonium formate buffer-methanol (19:81, v/v; adjusted to pH 4.0 with formic acid). The results were linear over the studied range (0.2-100 ng ml(-1)), with r2 = 1.0000, and the total analysis time for each run was 2 min. Intra- and interassay precisions were 0.70-8.54% and 1.08-4.85%, respectively, and intra- and interassay accuracies were 97.56-108.23% and 97.48-103.91%, respectively. The lower limit of quantification (LLOQ) was 0.2 ng ml(-1). At this concentration, mean intra- and interassay precisions were 8.54% and 4.85%, respectively, and mean intra- and interassay accuracies were 97.56% and 98.91%, respectively. The mean recovery ranged from 62.71 +/- 4.06 to 64.23 +/- 2.32%. Cimetropium was found to be stable in plasma samples under typical storage and processing conditions. The devised assay was successfully applied to a pharmacokinetic study of cimetropium bromide administered as a single oral dose (150 mg) to healthy volunteers.  相似文献   

2.
A simple, sensitive and rapid high-performance liquid chromatography/electrospray ionization tandem mass spectrometry method was developed and validated for the assay of amlodipine in human plasma. Following liquid-liquid extraction, the analytes were separated using an isocratic mobile phase on a reverse-phase C(18) column and analyzed by MS in the multiple reaction monitoring mode using the respective [M+H]+ ions, m/z 409/238 for amlodipine and m/z 409/228 for the IS. The assay exhibited a linear dynamic range of 50-10,000 pg/mL for amlodipine in human plasma. The lower limit of quantification was 50 pg/mL with a relative standard deviation of less than 8%. Acceptable precision and accuracy were obtained for concentrations over the standard curve range. The average absolute recoveries of amlodipine and the IS from spiked plasma samples were 74.7 +/- 4.6 and 72.1 +/- 2.0%, respectively. A run time of 1.5 min for each sample made it possible to analyze more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies. The observed maximum plasma concentration (Cmax) of amlodipine (2.5 mg oral dose) was 1425 pg/mL, time to observed maximum plasma concentration (Tmax) was 8.1 h and elimination half-life (T(1/2)) was 50.1 h.  相似文献   

3.
Salvianolic acid A (SAA), a major effective constituent of Salvia miltiorrhizas, is widely used in traditional Chinese medicine. A sensitive rapid analytical method was established and validated for SAA in rat plasma, which was further applied to assess the pharmacokinetics of SAA in rats receiving a single oral dose of SAA. The method used liquid chromatography tandem mass spectrometry in multiple reaction monitoring mode with chloramphenicol as the internal standard. A simple liquid-liquid extraction based on ethyl acetate was employed. The combination of a simple sample cleanup and short chromatographic run time (3 min) increased the throughput of the method substantially. The method was validated over the range 1.4-1000 ng/mL with a correlation coefficient >0.99. The lower limit of quantification was 1.4 ng/mL for SAA in plasma. Intra- and inter-day accuracies for SAA were 95-113 and 98-107%, and the inter-day precision was less than 12%. This method is more sensitive and faster than previous methods. After a single oral dose of 100 mg/kg of SAA, the mean peak plasma concentration (Cmax) of SAA was 318 ng/mL at 0.5 h, the area under the plasma concentration-time curve (AUC0-12 h) was 698 +/- 129 ng.h/mL, and the elimination half-life (T1/2) was 3.29 h.  相似文献   

4.
Gupta VK  Jain R  Lukram O  Agarwal S  Dwivedi A 《Talanta》2011,83(3):709-716
A rapid and sensitive liquid chromatography tandem mass spectrometry method has been developed and validated for the simultaneous determination of ramipril, ramiprilat and telmisartan in human plasma. The solid-phase extraction technique was used for the extraction of ramipril, ramiprilat and telmisartan from human plasma. Trandolaprilat and hydrochlorothiazide were used as the internal standards (ISs). Chromatography was performed on a Hypurity C18, 5 μm, 50 mm × 4.6 mm column, with the mobile phase consisting of ammonium acetate and acetonitrile (in a 20:80 ratio), followed by detection using mass spectrometry. The method involves a simple reversed isocratic chromatography condition and mass spectrometry detection, which enables detection at sub-nanogram levels. The method was validated and the lower limit of quantification for ramipril, ramiprilat and telmisartan was found to be 0.1 ng mL−1, 0.1 ng mL−1 and 2 ng mL−1, respectively. The mean recovery for ramipril, ramiprilat and telmisartan ranged from 90.1 to 104.1%. This method increased the sensitivity and selectivity; resulting in high-throughput analysis of ramipril, ramiprilat and telmisartan using two different ISs in a single experiment for bioequivalence studies, with a chromatographic run time of 1.5 min only.  相似文献   

5.
A sensitive, rapid and specific liquid chromatography–electrospray ionization–tandem mass spectrometry method was developed and validated for the determination of aristolochic acid‐I (AA‐I) in rat plasma. Finasteride was used as the internal standard (IS). The analyte was separated on a Zorbax Eclipse XDB‐C18 column by isocratic elution with methanol‐10 mM ammonium acetate (75:25, v/v, pH = 7.3) at a flow rate of 0.25 mL/min, and analyzed by mass spectrometry in positive multiple reaction monitoring mode. The precursor‐to‐product ion transitions of m/z 359.0 → 298.2 and m/z 373.1 → 305.2 were used to detect AA‐I and IS, respectively. Good linearity was achieved over a range of 0.4–600 ng/mL. Intra‐ and inter‐day precisions measured as relative standard deviation were less than 13.5%, and accuracy ranged from 94.2 to 97.5%. The developed method was successfully applied in the pharmacokinetic study of AA‐I in rats. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

6.
Hu W  Xu Y  Liu F  Liu A  Guo Q 《Biomedical chromatography : BMC》2008,22(10):1108-1114
A sensitive, specific and rapid high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was described and validated for the quantification of ambroxol in human plasma using enalaprilat as the internal standard (IS). Chromatographic separation was performed on a Lichrospher CN column with a mobile phase of methanol and water (containing 0.1% formic acid) (70:30, v/v). The total run time was 5.0 min for each sample. The analytes was detected by mass spectrometry with electrospray ionization source in positive selected reaction monitoring mode. The precursor-fragment ion reaction for ambroxol was m/z 378.9 --> 263.8, and for IS was m/z 349.0 --> 205.9. The linearity was established over the concentration range of 1.56-400.00 ng/mL. The inter-day and the intra-day precisions were all within 10%. A simple protein precipitation with methanol was adopted for sample preparation. The extraction recoveries of ambroxol and IS were higher than 90.80%. The validated method was successfully applied in pharmacokinetic study after oral administration of 90 mg ambroxol to 24 healthy volunteers.  相似文献   

7.
Yoon KH  Lee SY  Jang M  Ko SH  Kim W  Park JS  Park I  Kim HJ 《Talanta》2005,66(4):831-836
A simple, fast and sensitive high-performance liquid chromatography (HPLC)-electrospray ionization (ESI) tandem mass spectrometric method (LC-MS/MS) has been developed for determination of propiverine and propiverine N-oxide metabolite in human plasma using oxybutynin as internal standard. Instead of extracting propiverine from plasma using organic solvents, which should be separated from the aqueous phase and evaporated before injecting the sample into the chromatograph, plasma sample containing propiverine and N-oxide was directly injected after precipitating proteins with acetonitrile. Numerous compounds in the plasma did not interfere with the highly specific multiple reaction monitoring in tandem mass spectrometric detection following C8 reversed-phase chromatographic separation under conditions that eluted propiverine, N-oxide and oxybutynin within 2 min (0.1% formic acid in water/acetonitrile, 25:75, v/v). The LC-MS/MS method and an alternative LC-MS method, using methyl-t-butyl ether extraction and selected ion monitoring, were validated over 1-250 ng ml−1 of propiverine and 2 to 500 ng ml−1 of N-oxide, and successfully applied in a pharmacokinetic study. The lower limit of quantitation was 1 ng ml−1 for propiverine and 2 ng ml−1 for N-oxide in both methods.  相似文献   

8.
Two methods for determining the central-acting muscle relaxant afloqualone in human plasma were developed and compared using API2000 and API4000 liquid chromatography tandem mass spectrometry (LC/MS/MS) systems. In the API2000 LC/MS/MS system, afloqualone and the internal standard methaqualone were extracted from plasma using a methyl-tertiary ether. After drying the organic layer, the residue was reconstituted in a mobile phase (0.1% formic acid-acetonitrile:0.1% formic acid buffer, 80:20 v/v) and injected onto a reversed-phase C18 column. The isocratic mobile phase was eluted at 0.2 ml/min. The ion transitions monitored in multiple reaction-monitoring mode were m/z 284 → 146 and 251 → 117 for afloqualone and methaqualone, respectively.Sample preparation for the API4000 LC/MS/MS system involved simple protein precipitation with an organic mixture (methanol:10% ZnSO4 = 8:2). The ion transitions monitored in multiple reaction-monitoring mode were m/z 284 → 146 and 251 → 131 for afloqualone and methaqualone, respectively.In both assays, the coefficient of variation of the precision was less than 11.8%, the accuracy exceeded 91.5%, the limit of quantification was 0.5 ng/ml, and the limit of detection was 0.1 ng/ml for afloqualone. Two methods were used to measure the plasma afloqualone concentration in healthy subjects after a single oral 20-mg dose of afloqualone. During subsequent application of the methods, we observed that high-concentration plasma samples (>7 ng/ml) prepared using the protein precipitation method resulted in about 20% higher afloqualone concentrations than with plasma samples prepared using the liquid-liquid extraction method. We believe that this phenomenon was related to the cleanness of the sample and its chemical nature.  相似文献   

9.
An assay based on protein precipitation and liquid chromatography/tandem mass spectrometry (LC-MS/MS) has been developed and validated for the quantitative analysis of lisinopril in human plasma. After the addition of enalaprilat as internal standard (IS), plasma samples were prepared by one-step protein precipitation using perchloric acid followed by an isocratic elution with 10 mm ammonium acetate buffer (pH adjusted to 5.0 with acetic acid)-methanol (70:30, v/v) on a Phenomenex Luna 5 mu C(18) (2) column. Detection was performed on a triple-quadrupole mass spectrometer utilizing an electrospray ionization (ESI) interface operating in positive ion and selected reaction monitoring (SRM) mode with the precursor to product ion transitions m/z 406 --> 246 for lisinopril and m/z 349 --> 206 for enalaprilat. Calibration curves of lisinopril in human plasma were linear (r = 0.9973-0.9998) over the concentration range 2-200 ng/mL with acceptable accuracy and precision. The limit of detection and lower limit of quantification in human plasma were 1 and 2 ng/mL, respectively. The validated LC-MS/MS method has been successfully applied to a preliminary pharmacokinetic study of lisinopril in Chinese healthy male volunteers.  相似文献   

10.
The confirmatory LC-MS/MS method for the determination of residues for twelve coccidiostats including ionophore antibiotics (lasalocid, maduramycin, monensin, narasin, salinomycin, semduramycin) and chemical coccidiostats (clazuril, decoquinate, diclazuril, halofuginone, nicarbazin and robenidine) in poultry liver has been developed. The sample preparation was based on extraction with acetonitrile, defatting with Alumina columns and clean-up on Oasis HLB spe. The separation of analytes was performed on PhenylHexyl column with a gradient of acetonitrile, methanol and the ammonium formate pH 4.0. For all analytes, at least 2 diagnostic fragmentation ions were monitored. The validation, performed according to the CD 2002/657/EC, proved the suitability of the method for the confirmatory analysis of the coccidiostats. For lasalocid, however, low reproducibility was observed and the proper quantification could not be performed with this method.  相似文献   

11.
In the present study, a simple and rapid method for metamizole metabolite 4-methylamino antipyrine (MAA) determination in human plasma was developed, validated and successfully applied to a clinical trial. Chromatographic separation was achieved in HILIC mode on a YMC-Pack SIL column (100 × 2.0 mm; S-5 μm, 30 nm), with a mobile phase consisting of acetonitrile, water and formic acid. Protein precipitation of a small plasma volume using acetonitrile was selected for sample preparation. The multiple reaction monitoring transitions in the positive ionization mode were m/z 218.2 → 56.2 for MAA and m/z 221.2 → 56.2 for MAA-d3 (IS, internal standard). Concentration levels of MAA calibration standards were in the range of 0.100–20 μg/ml. Metamizole conversion into MAA in both water and organic media was investigated, and the level of the conversion in commercially available injection solutions was estimated.  相似文献   

12.
A reversed-phase HPLC method for the analysis of cephalexin (7-[(aminophenylacetyl)amino]-3-methyl-8-oxo-5-thia-1-azabicyclo[4.2.0]oct-2-ene-2-carboxylic acid) by isocratic separation is described. A comparison is made between the ultrafiltration land the extraction procedure developed in our laboratory. The extraction procedure, based on the deproteinization of plasma with perchloric acid followed by the extraction with dichloroethane and separation of cephalexin on a reversed phase column, gave better recovery. Quantitative validation of our method has been performed by an external standard technique. The relative standard deviations were between 1.1 and 1.9% in the within-day assay and between 1.2 and 2.2% in the inter-day assay. The limit of detection was 0.14ug/ml and the limit of quantification was 0.28ug/ml. This method is rapid, sensitive, simple, and reproducible. The LC MS/MS technique was successfully used for identification and quantification of cephalexin in human plasma samples.  相似文献   

13.
An improved LC-MS/MS method for the determination of semicarbazide in whole egg is described. Waters OASIS-MCX cation exchange purification cartridges increased the sensitivity for analysis by LC-MS/MS. The validation study was carried out according to criteria and requirements of Commission Decision 2002/657/EC for confirmatory analysis and provided the data as follows: The correlation coefficient for the matrix calibration curve, in the range of 0–5 μg kg−1, was r = 0.9968. The detection capability and decision limit, measured according to ISO11843-2, were CCα = 0.20 μg kg−1 and CCβ = 0.25 μg kg−1. Repeatability (CVSr) and within-laboratory reproducibility (CVSwr) determined for the concentration levels of 0.2, 0.5 and 1.0 μg kg−1 SEM ranged from 11.9 to 5.7% and 11.8 to 6.3%, respectively. The validated method was applied to investigate SEM stability in incurred materials (egg homogenates) during long-term storage at −20 °C and 4 °C. The study proved by a two-sampling test that SEM at levels of 17. 7, 1.2, 10.6 and 0.47 μg kg−1 was stable for up to 12 months.  相似文献   

14.
A rapid and sensitive LC‐MS/MS method for the quantification of fenofibric acid in rat plasma was developed and validated. Plasma samples were prepared by liquid–liquid extraction with a mixture of N‐hexane–dichloromethane–isopropanol (100:50:5, v/v/v). Isocratic chromatographic separation was performed on a reversed‐phase Discovery C18 column (2.1 × 50 mm, 5 µm). The mobile phase was methanol–water–formic (75:25:0.25, v/v/v). Detection of fenofibric acid and the internal standard (IS) diclofenac acid was achieved by ESI MS/MS in the negative ion mode using m/z 317 → m/z 213 and m/z 294 → m/z 250 transitions, respectively. The method was linear from 0.005 to 1.250 µg/mL when 100 μL plasma was analyzed. The lower limit of quantification was 0.005 µg/mL. The intra‐ and inter‐day precision values were below 8.2%, and accuracy ranged from ?0.9 to 2.1% in all quality control samples. The recovery was 90.3–94.7% and 83.3% for fenofibric acid and IS, respectively. Total run time for each sample analysis was 2.5 min. The validated method was successfully applied to a pharmacokinetic study in six rats after oral administration of fenofibrate, the ester prodrug of fenofibric acid (equivalent to fenofibric acid 5 mg/kg). The method permits laboratory scientists with access to the appropriate instrumentation to perform rapid fenofibric acid determination. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

15.
Furanodiene, a sesquiterpene component extracted from the essential oil of the rhizome of Curcuma wenyujin Y.H. Chen et C. Ling (Wen Ezhu), is widely used in traditional Chinese medicine. A sensitive analytical method was established and validated for furanodiene in rat plasma, which was further applied to assess the pharmacokinetics of furanodiene in rats receiving a single dose of furanodiene. Liquid chromatography tandem mass spectrometry (LC/MS/MS) in multiple reaction monitoring mode was used in the method and costundide was used as internal standard. A simple protein precipitation based on methanol was employed. The simple sample cleanup increased the throughput of the method substantially. The method was validated over the range of 1–1000 ng/mL with a correlation coefficient >0.99. The lower limit of quantification was 1 ng/mL for furanodiene in plasma. Intra‐ and inter‐day accuracies for furanodiene were 88–115 and 102–107%, and the inter‐day precision less than 14.4%. After a single oral dose of 10 mg/kg of furanodiene, the mean peak plasma concentration of furanodiene was 66.9 ± 23.4 ng/mL at 1 h, the area under the plasma concentration–time curve (AUC0–10 h) was 220 ± 47.8 h ng/mL, and the elimination half‐life was 1.53 ± 0.06 h. After an intravenous adminstration of furanodiene at a dosage of 5 mg/kg, the area under the plasma concentration–time curve was 225 ± 76.1 h?ng/mL, and the elimination half‐life was 2.40 ± 1.18 h. Based on this result, the oral bioavailability of furanodiene in rats at 10 mg/kg is 49.0%. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

16.
The separation and detection of 11 urinary aromatic acids was developed using HPLC-MS/MS. The method features a simple sample preparation involving a single-step dilution with internal standard and a rapid 8 min chromatographic separation. The accuracy was evaluated by the recovery of known spikes between 87 and 110%. Inter- and intra-assay precision (CV) was below 11% in all cases and the analytes were observed to be stable for up to 8 weeks when stored at -20 degrees C. The method was validated based upon linearity, accuracy, precision and stability and was used to establish reference intervals for children and adults.  相似文献   

17.
Oral prochlorperazine (PCZ), an antiemetic, undergoes extensive first-pass metabolism. The study developed a simultaneous analytical method for PCZ and its major metabolites, prochlorperazine sulfoxide (PCZSO), N-demethylprochlorperazine (NDPCZ) and 7-hydroxyprochlorperazine (PCZOH), in human plasma using an isocratic liquid chromatography-tandem mass spectrometry (LC-MS/MS) method. Deproteinized plasma specimens were separated using a 3 μm particle size octadecylsilyl column, and the run time was 10 min. The calibration curves were linear over the concentration ranges of 0.01-40 μg/L for PCZ, NDPCZ and PCZOH, and 0.05-80 μg/L for PCZSO. The intra- and inter-assay precisions and accuracies were within 7.0 and 99-104% and within 9.0 and 99-105%, respectively. The lower limits of quantification in human plasma were 10 ng/L for PCZ, NDPCZ and PCZOH, and 50 ng/L for PCZSO. The validated method was applied to the determination of plasma samples in 37 cancer patients receiving PCZ. Large interindividual variations were observed in plasma concentrations of PCZ, PCZSO, NDPCZ and PCZOH (relative standard deviation, 89.4, 88.7, 86.4 and 78.2%, respectively). In conclusion, this simultaneous LC-MS/MS method with acceptable analytical performance can be helpful for evaluating the pharmacokinetics of PCZ, including the determination of its metabolites in cancer patients and in clinical research.  相似文献   

18.
BMS-378806 is a human immunodeficiency virus (HIV) entry inhibitor that is being developed for the oral treatment of HIV infection. Human plasma and urine LC/MS/ MS methods have been developed and validated for the quantitation of BMS-378806. For human plasma method, methyl t-butyl ether was used to extract BMS-378806 from plasma in a 96-well format, and the organic layers were dried down and then reconstituted for the injection, while a dilute-and-shoot approach was used for human urine method in a 96-well format. Chromatographic separation was achieved isocratically on a Phenomenex C18 (2) Luna column (2 x 50 mm2, 5 microm). The mobile phase contained 60:40 v/v of 0.1% formic acid in water and ACN. Detection was by positive ion electrospray MS/MS. The standard curves ranged from 1.25 to 1000 ng/mL for the plasma assay and from 10 to 5000 ng/mL for the urine assay. The curves were fitted to a 1/x2 weighted quadratic regression model for both methods. The validation results demonstrated that both methods had satisfactory precision and accuracy across the calibration ranges. The methods were applied to the analysis of human plasma and urine samples from a single ascending dose clinical study to assess the pharmacokinetics of the drug. The pharmacokinetic analysis results indicated the absorption and disposition of the drug was rapid. The systemic exposure of BMS-378806 was generally dose proportional among the doses from 100 to 1200 mg, but not dose proportional to 1600 mg. There were modest increases in the systemic exposure when the drug was given with food or given as a solution formulation. Renal excretion was not a substantial elimination pathway of the drug. BMS378806 was safe and well tolerated over a dose range of 100-1600 mg administered as a single oral dose.  相似文献   

19.
A rapid and sensitive method based on liquid chromatography/tandem mass spectrometry (LC/MS/MS) for the determination of echinacoside in rat plasma was established and fully validated. A single step of liquid–liquid extraction with n‐butanol was utilized. Chromatographic separation of the analyte and the internal standard (IS), chlorogenic acid, from the sample matrix was performed using a Capcell‐MG C18 analytical column (100 2.0 mm × 5 µm), with a gradient of acetonitrile and water containing 0.1% acetic acid as the mobile phase. Detection was performed on a triple quadrupole tandem mass spectrometer equipped with electrospray ionization source operated in negative ion selected reaction monitoring mode. The method was linear in the concentration range 10–2500 ng/mL. The deviations of both intra‐ and inter‐day precisions (RSD) were 7.1% and the assay accuracies were within 99.2–106.5%. Echinacoside proved to be stable during sample storage, preparation and analysis when an antioxidant solution was used. The method was successfully applied to a pharmacokinetic study in rats after an intragastric administration of echinacoside (100 mg/kg). With the lower limit of quantification at 10 ng/mL, this method proved to have sufficient selectivity, sensitivity and reproducibility for the pharmacokinetic study of echinacoside. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

20.
A simple and sensitive high‐performance liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed and validated for simultaneous determination of shanzhiside methylester and its three derivatives in rabbit plasma. The method showed good linearity and no endogenous material interfered with the marked compounds and internal standard (IS) capatol peaks. Samples were processed by acetonitrile precipitation. Chromatography was performed using a C18 column (150 × 3.9 mm i.d., 4 µm). The mobile phase consisted of methanol and water (60:40, v/v) during a total run time of 7 min. The main mass parent ions and daughter ions pairs (m/z) for monitoring were: shanzhiside methylester, 429.0/267.4; 8‐O‐acetyl shanzhiside methylester, 470.9/411.3; loganin, 413.2/251.4; phloyoside II, 479.2/281.3; and IS 385.2/203.3. Finally, the method was applied to a pharmacokinetic study of rabbits following intravenous administration of iridoid glycosides extracted from traditional herb Lamiophlomis rotata. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号