首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 58 毫秒
1.
In the present work, a slurry sampling flame atomic absorption spectrometric method to determine directly manganese and zinc in powdered chocolate samples is proposed. The optimization step was performed using univariate methodology involving the following factors: nature and concentration of the acid solution, sonication time, and particle size. The established conditions led to the use of a sample mass of 150 mg, 2.0 mol L− 1 nitric acid solution, sonication time of 15 min, and a slurry volume of 50 mL. This method allows the determination of manganese and zinc with detection limit of 52 and 61 ng g− 1, respectively, and a precision expressed as relative standard deviation (RSD) of 2.6% and 3.2% (both, n = 10) for contents of manganese and zinc of 52.4 and 100.0 μg g− 1, respectively. The proposed method was applied for determination of manganese and zinc in five powdered chocolate samples. In these, the manganese content varied from 42.8 to 52.7 and from 88.6 to 102.4 μg g− 1 of zinc. The analytical results were compared with the results obtained by analysis of these samples after digestion using open vessel and acid bomb digestion procedures and determination using FS-FAAS. The statistical comparison by t-test (95% confidence level) showed no significant difference between these results.  相似文献   

2.
建立了火焰原子吸收光谱法测定冰晶石中铁的分析方法。样品用高氯酸溶解后,在0.48mol/L的盐酸介质中用空气-乙炔火焰测定了样品中的铁,测定结果与有色金属行业标准方法(邻二氮杂菲光度法)的分析结果一致。检出限为0.004 11mg/L,相对标准偏差(RSD)为0.95%~4.5%,加标回收率为98.00%~101.49%。  相似文献   

3.
Manganese is extracted on-line from solid seafood samples by a simple continuous ultrasound-assisted extraction system (CUES). This system is connected to an on-line manifold, which permits the flow-injection flame atomic absorption spectrometric determination of manganese. Optimisation of the continuous leaching procedure is performed by an experimental design. The proposed method allows the determination of manganese with a relative standard deviation of 0.9% for a sample containing 23.4 μg g−1 manganese (dry mass). The detection limit is 0.4 μg g−1 (dry mass) for 30 mg of sample and the sample throughput is ca. 60 samples per hour. Accurate results are obtained by measuring TORT-1 certified reference material. The procedure is finally applied to mussel, tuna, sardine and clams samples.  相似文献   

4.
Narin I  Soylak M 《Talanta》2003,60(1):215-221
1-(2-pyridylazo) 2-naphtol (PAN) impregnated Ambersorb 563 resin was used as solid phase extractor of copper, nickel, cadmium, lead, chromium and cobalt ions in aqueous solutions prior to their atomic absorption spectrometric determinations. The parameters including pH, sample volume, matrix effects were also investigated. The relative standard deviation (R.S.D.) of the combined method of sample treatment, preconcentration and determination with atomic absorption spectrometry is generally lower than 10%. The limit of detection was between 0.21 and 1.4 μg l−1. The results were used for preconcentration of analyte ions from natural water samples. The method was also applied to a stream sediment standard reference material (GBW7309) for the determination of Cu, Ni, Cd, Pb, Cr and Co.  相似文献   

5.
A procedure has been proposed for the separation and preconcentration of trace amounts of thallium. It is based on the adsorption of thallium ions onto organo nanoclay loaded with 1-(2-pyridylazo)-2-naphthol (PAN). Thallium ions were quantitatively retained on the column in the pH range of 3.5–6.0, whereas quantitative desorption occurs with 5.0?mL of 5% ascorbic acid and thallium was determined by flame atomic absorption spectrometry. Linearity was maintained between 0.66?ng?mL?1–15.0?µg?mL?1?in initial solution. Detection limit was 0.2?ng?mL?1?in initial solution and preconcentration factor was 150. Eight replicate determinations of 2.0?µg?mL?1 of thallium in final solution gave a relative standard deviation of ±1.48%. Various parameters have been studied, such as the effect of pH, breakthrough volume and interference of a large number of anions and cations and the proposed method was used to determine thallium ions in water and standard samples. Determination of thallium ions in standard sample showed that the proposed method has good accuracy.  相似文献   

6.
采用微波消化技术,以氘灯背景校正方式,在HNO3介质中,直接用火焰原子吸收法在同一体系中连续测定了金银花中微量元素Fe、Zn、Cu、Mn,并优化了最佳实验条件.在选定条件下,检出限为Fe 0.0047 μg/mL,Zn 0.0032μg/mL,Cu 0.0052μg/mL,Mn 0.0028μg/mL,相对标准偏差为1.5%~3.2%,回收率为96.4%~103.4%.适用于金银花中微量Fe、Zn、Cu、Mn的测定.  相似文献   

7.
Methods were developed for indium (In) determination in complex ores by electrothermal atomization atomic absorption spectrometry using matrix modification after its separation with Amberlite XAD-2 coated with 1-(2-pyridylazo)-2-naphthol (PAN). Palladium-magnesium, nickel, and zinc nitrates were used as matrix modifiers and were compared in terms of maximum pyrolysis temperature, sensitivity and background signal. They have enhanced the absorption signals for indium, respectively eliminating the matrix interferences. The standard additions method was applied. The relative standard deviations for six replicate determinations were in the range 0.3-4.0% for indium in different ores samples for indium concentrations 7.6-209 μg g−1. The recommended method was applied to the indium determination in real samples. The data obtained by this method were in good agreement with those obtained by ICP-AES.  相似文献   

8.
纳米SiO_2分离富集-火焰原子吸收法测定水中痕量银   总被引:4,自引:0,他引:4  
研究了纳米SiO_2分离富集-火焰原子吸收法测定水中痕量银的新方法.考察了溶液pH、吸附时间、洗脱条件和干扰离子等因素对Ag~+分离富集的影响,确定了纳米SiO_2对Ag~+吸附的最佳条件.结果表明:在pH 4.1时,纳米SiO_2能定量吸附银,吸附在纳米SiO_2上的Ag~+可用0.5 mol/L HCl+0.5 mol/L硫脲定量洗脱.该法对银的检出限为0.77 ng/mL(3σ,n=11);线性范围为0.005~1.5μg/mL,对0.5μg/mL的Ag~+标液进行7次测定,RSD为3.6%,回收率在94.0%~101.5%之间;方法可用于环境水样中痕量银的测定.  相似文献   

9.
A new column, solid-phase extraction (SPE), preconcentration method was developed for determination of Cd, Co, and Cu ions in natural water samples by flame atomic absorption spectrometry. The procedure is based on the retention of analytes in the form of 2,4-dinitrophenyldiazoaminoazobenzene (DNDAA) complex on a mini column of DNDAA-XAD-2 resin. The effects of pH, eluent type, eluent concentration, eluent volume, resin quantity, sample volume, sample flow rate, and matrix ions (Na, Ca, and Mg) were investigated on the recovery of the metals using model solutions. The detection limit for Cd, Co, and Cu was 0.062, 0.084, and 0.057 μg L−1 and the quantification limit was 0.17, 0.24, and 0.12 μg L−1 respectively. The method was validated by the analysis of a certified reference material with the results being in agreement with those quoted by manufactures. The developed method was applied to the determination of trace metal ions in tap water, river water samples with satisfactory results.  相似文献   

10.
A sensitive and simple solid-phase preconcentration procedure for enrichment of cadmium prior to analysis by flame atomic absorption spectrometry (FAAS) is described. The method is based on the adsorption of cadmium as CdI42− on naphthalene-methyltrioctylammonium chloride adsorbent, elution by nitric acid and subsequent determination by FAAS. The effect of pH, iodide concentration, sample flow rate, volume of the sample and diverse ions on the recovery of the analyte was investigated and optimum conditions were established. A preconcentration factor of 40 was achieved using the optimum conditions. The calibration graph was linear in the range 1-100 ng ml−1 cadmium in the initial solution. The detection limit based on the 3Sb criterion was 0.6 ng ml−1 and the relative standard deviations (RSD) were 3.9 and 1.05% for 5 and 40 ng ml−1, respectively (n=8). The method was successfully applied to the determination of cadmium added to river, tap and Persian Gulf water samples.  相似文献   

11.
A method is described for the simultaneous multielement determination of yttrium and lanthanides at microgram level. This is based on the preconcentration of these lanthanides on to 1-(2-pyridylazo)-2-naphthol (PAN) modified naphthalene. The optimal conditions for quantitative preconcentration viz., pH, amount of PAN modified naphthalene, time of stirring and aqueous phase volume were systematically evaluated. The quantitation of lanthanides was carried out by energy dispersive X-ray fluorescence analyzer, employing241Am annular source, via their characteristic K X-rays. The developed procedure gave reliable results in the analysis of xenotime samples.  相似文献   

12.
交联壳聚糖分离富集-火焰原子吸收法测定水样中痕量银   总被引:3,自引:0,他引:3  
以甲醛、环硫氯丙烷为交联剂,由壳聚糖合成了一种新型的交联壳聚糖微球(FCCIS)分离树脂,研究了不同条件下FCCTS对Ag(Ⅰ)的吸附性能.在pH 3.6时FCCTS对Ag(Ⅰ)定量吸附,吸附在树脂上的Ag(Ⅰ)可用0.5 moL/L的氨水将其洗脱,用火焰原子吸收光谱测定.该法对Ag(Ⅰ)的检出限为61 ng/mL(3σ,n=8),相对标准偏差为2.2%(n=7,ρ=2μg/mL),线性范围为0.05~4μg/mL,加标回收率在98.8%~101.7%之间.该法已用于水样中痕量银测定.  相似文献   

13.
建立了大孔径树脂D101负载硫杂杯芳烃树脂微柱分离富集-火焰原子吸收光谱法测定痕量金的新方法。探讨了负载硫杂杯芳烃树脂对金的吸附原理与最佳条件。该法对金的检出限为0.23 ng/mL(3σ,n=11),线性范围为0.01~1μg/mL。对0.2μg/mL的Au 标液进行5次测定,RSD=2.1%,加标回收率在98.4%~103.3%之间。方法用于矿渣样中痕量金的分析。  相似文献   

14.
Taher MA  Puri S  Bansal RK  Puri BK 《Talanta》1997,45(2):411-416
Iridium is preconcentrated from the large volume of its aqueous solution using 1-(2-pyridylazo-2-naphthol) (PAN) on microcrystalline naphthalene in the pH range of 4.5-6.0. The solid mass after filtration is dissolved with 5 ml of dimethylformamide (DMF) and the metal determined by first derivative spectrophotometry. The detection limit is 20 ppb (signal to noise ratio = 2) and the calibration curve is linear over the concentration range 0.25-75.0 mug in 5 ml of the final DMF solution with a correlation coefficient of 0.9996 and relative standard deviation of +/- 1.1%. Various parameters such as the effect of pH, volume of aqueous phase, choice of solvent, reagent and naphthalene concentration, shaking time and interference of a number of metal ions on the determination of trace amount of iridium have been studied in detail to optimize the conditions for its determination in synthetic samples corresponding to various standard alloys and environmental samples.  相似文献   

15.
炭末中银的准确测定对于其金属平衡和贸易结算具有重要意义。采用硝酸-硫酸体系除碳分解试样,在20%盐酸介质中,采用空气-乙炔火焰,以328.1nm作为测定波长,建立了火焰原子吸收光谱法(FAAS)测定炭末中银的方法。在最优的实验条件下,银质量浓度在0.30~3.00μg/mL范围内与其吸光度呈良好线性关系,相关系数为0.9999。方法检出限为0.004μg/mL,定量下限为0.013μg/mL。干扰试验表明,根据炭末中干扰元素含量,在载金炭国家标准物质中加入一定量的共存元素,共存元素不影响银量的测定。实验方法用于测定实际炭末样品中银,结果的相对标准偏差(RSD,n=7)为0.91%~3.4%,且结果与《GB∕T 29509.2-2013 载金炭化学分析方法 第2部分:银量的测定 火焰原子吸收光谱法》方法测定结果一致。按照实验方法测定了4个载金炭标准样品中银,结果与标准值吻合。准确度和精密度符合实际生产需求,可用于炭末中银的测定。  相似文献   

16.
The formation of the Tm(III) complex with 1-(2-pyridylazo)-2-naphthol (PAN or HL) in aqueous-methanol mixtures (50 and 75%v/v) was studied by a spectrophotometric method. The equilibrium constant for the complexing reaction and the stability constant of the complex TmL 2+ were calculated. The solvent extraction of Tm(III) byPAN in carbon tetrachloride from aqueous and aqueous-methanol phase was investigated. The extraction equilibrium constants and two-phase stability constants for the TmL 3 and the TmL 3(MeOH)3 complexes were evaluated. It was confirmed that the addition of methanol to the aqueous phase (above 25%v/v) causes a synergistic effect.
Extraktion von Ionen der Seltenerdmetalle mit 1-(2-Pyridylazo)-2-naphthol (PAN), 5. Mitt.: Komplexbildung und Gleichgewichtsverteilung von Thulium (III) mitPAN
Zusammenfassung Die Bildung des Komplexes von Tm(III) mit 1-(2-Pyridylazo)-2-naphthol (PAN oder HL) in Wasser-Methanol Mischungen (50 und 75%v/v) wurde mit einer spektrophotometrischen Methode untersucht. Die Gleichgewichtskonstante für die Reaktion der Komplexbildung und die Stabilitätskonstante des Komplexes TmL 2+ wurden berechnet. Die Extraktion von Tm(III) mittelsPAN in Kohlenstofftetrachlorid aus Wasser oder Wasser-Methanol wurde untersucht. Die Werte der Extraktionsgleichgewichtskonstante sowie der zweiphasigen Beständigkeitskonstante für die Komplexe TmL 3 und TmL 3(MeOH)3 wurden berechnet. Es wurde festgestellt, daß die Zugabe von Methanol zur wäßrigen Phase (25%v/v) einen synergistischen Effekt hat.
  相似文献   

17.
鸡尾木(ExcoecariaVenenataS.LeeetF.N.Wei)属大戟科,海漆属,为民间药用珍贵植物,用于治疗牛皮癣、慢性湿疹等,疗效颇佳[1]。鸡尾木中无机元素,尤其是医学微量元素的测定对其药理效的研究有重要的参考价值。1 实验部分1 1 仪器及试剂TAS 986原子吸收分光光度计(北京普析通用仪器有限责任公司);空心阴极灯:Fe、Cu、Ni、Cr、Cd、Zn、Co、Ba、Ca(北京瑞利普光电器厂);Mg、Pb(北京真空电子技术总公司);Mn(北京市朝阳天宫电器厂);AdventurerTM电子天平(奥豪斯国际贸易〈上海〉有限公司)。标准储备液:配制Zn2+、Mg2+、Fe3+、Mn2…  相似文献   

18.
The solvent extraction of Yb(III) and Ho(III) by 1-(2-pyridylazo)-2-naphthol (PAN or HL) in carbon tetrachloride from aqueous-methanol phase has been studied as a function ofpH × and the concentration ofPAN or methanol (MeOH) in the organic phase. When the aqueous phase contains above ~25%v/v of methanol the synergistic effect was increased. The equation for the extraction reaction has been suggested as: $$\begin{gathered} Ln(H_2 0)_{m(p)}^{3 + } + 3 HL_{(o)} + t MeOH_{(o)} \mathop \rightleftharpoons \limits^{K_{ex} } \hfill \\ LnL_3 (MeOH)_{t(o)} + 3 H_{(p)}^ + + m H_2 0 \hfill \\ \end{gathered} $$ where:Ln 3+=Yb, Ho; $$\begin{gathered} t = 3 for C_{MeOH in.} \varepsilon \left( { \sim 25 - 50} \right)\% {\upsilon \mathord{\left/ {\vphantom {\upsilon \upsilon }} \right. \kern-\nulldelimiterspace} \upsilon }; \hfill \\ t = 0 for C_{MeOH in.} \varepsilon \left( { \sim 5 - 25} \right)\% {\upsilon \mathord{\left/ {\vphantom {\upsilon \upsilon }} \right. \kern-\nulldelimiterspace} \upsilon } \hfill \\ \end{gathered} $$ . The extraction equilibrium constants (K ex ) and the two-phase stability constants (β 3 × ) for theLnL 3(MeOH)3 complexes have been evaluated.  相似文献   

19.
Extraction of lutetium(III) and erbium(III) with 1-(2-pyridylazo)-2-naphthol (PAN or HL) in carbon tetrachloride from aqueous solutions was examined. The composition of the complex extracted was determined and it was found that the extraction process can be described by the following equation (Ln 3+=Lu, Er): $$Ln(H_2 O)_m^{3 + } + 3 HL_{(0)} \mathop \rightleftharpoons \limits^{K_{ex} } LnL_{3(0)} + 3 H^ + + mH_2 O$$ The extraction constants (K ex ) and two-phase stability constants (β 3 x ) forLnL 3 complexes have been evaluated.  相似文献   

20.
提出了以732强酸型阳离子树脂作填充材料,流动注射在线离子交换预富集火焰原子吸收光谱法测定水样中微量锰的分析方法。优化了各项化学条件和流路参数等,考察了共存离子的干扰。富集倍数可达24倍,分析速度为15~20样/h,检出限为2.0ng/mL,相对标准偏差为2.8%(n=15)。对雨水加标回收,回收率为97%~103%。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号