首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 265 毫秒
1.
A high-speed determination of benzene in gasoline samples using a non-separative method based on direct injection into the mass spectrometer is proposed. The results obtained are very similar to those provided with fast GC-MS.The calibration set was made up of gasoline samples in which the benzene was determined chromatographically and samples of gasoline subjected to a process of evaporation - until the complete disappearance of the original benzene - to which known concentrations of this compound had been added. A PLS1 multivariate calibration model was constructed. Cross-validation was used to select the optimum number of PLS components. The prediction capacity of the model was checked with an additional group of gasoline samples that had not been used either in the construction or in the validation of the model.With the direct injection method proposed here it was possible to analyse 24 samples over a period of 1 h. The direct injection method is rapid, simple and - in view of the results - highly suitable for the determination of benzene in gasoline samples.  相似文献   

2.
A high-speed quantitative analysis of methyl tert-butyl ether (MTBE) using three different methods with mass spectrometry detection has been performed. The first method is based on fast chromatography and required an analysis time of 5.23 min per sample, although a certain period (6 min) was necessary for the initial measurement conditions to be regained prior to analysing the next sample. The other two are non-separative methods and are based on direct injection and headspace generation. The analysis times were 1.5 and 3.5 min, respectively, although in the latter case an additional period of time was required to extract volatiles from the sample. The analytical characteristics of all three methods are highly satisfactory in terms of linearity, lack of fit, precision and accuracy. The methods were applied to the determination of MTBE in different gasoline samples. The non-separative methods afforded slightly higher concentrations than those found when fast chromatography was used; this is due to the presence of other minor components that contribute to the abundance of the ion at m/z 73, characteristic of MTBE. We propose a correction that removes this error very satisfactorily and allows the same results to be obtained with all three methodologies proposed.  相似文献   

3.
The study compares standard addition (SA), stable isotope dilution assay (SIDA) and multiple headspace extraction (MHE) as methods to quantify furan and 2-methyl-furan in roasted coffee with HS-SPME-GC-MS, using CAR-PDMS as fibre coating, d(4)-furan as internal standard and in-fibre internal standardization with n-undecane to check the fibre reliability. The results on about 150 samples calculated with the three quantitation approaches were all very satisfactory, with coefficient of variation (CV) versus the U.S. Food and Drug Administration (FDA) method, taken as reference, almost always below the arbitrarily-fixed limit of 15%. Furan was detected in the 1-5 ppm range, 2-methyl-furan in the 4-20 ppm range. Moreover, experimental exponential slopes (Q) and linearity (r) of both furan and 2-methyl-furan MHE regression equation on 50 samples were very similar thus making possible to use the same average Q value for all samples of the investigated set and their quantitation with a single determination. This makes this approach very rapid and competitive in-time with SA and SIDA. A non-separative method (HS-SPME-MS) was also developed in view of possible application on-line monitoring of furan and 2-methyl-furan in a pilot-plant with the aim of optimizing the roasting process to reduce these compounds to a minimum. Sampling times of 20 and 5 min were tested, the latter enabling total analysis time to be reduced to about 9 min. The results on 105 samples with both SIDA and MHE approaches were again highly satisfactory most of the samples giving a CV% versus the conventional methods below 20%. In this case too average Q values for both furan and 2-methyl-furan were used for MHE. The separative method presented very good repeatability (RSD% always below 10%) and intermediate precision over three months (RSD% always below 15%); performance were similar for the non-separative method, with repeatability (RSD%) always below 12% and intermediate precision over three months (RSD%) always below 15%. The sensitivity of both separative and non-separative methods was also very good, LOD and LOQ being in the ppb range for both furan and 2-methyl-furan, i.e. well below the amounts present in the roasted coffee samples.  相似文献   

4.
The pyrolysis of chlorinated polybutadienes (CPB) was investigated by using a pyrolysis gas chromatograph. CPB corresponds to poly(vinyl chloride) (PVC) constructed with head–head and tail–tail linkages of the vinyl chloride unit. Benzene, toluene, ethyl-benzene, o-xylene, styrene, vinyltoluene, chlorobenzenes, naphthalene, and methylnaphthalenes were detected in the pyrolysis products from CPB above 300°C, and no hydrocarbons could be detected at 200°C. The pyrolysis products from CPB were similar to those from PVC and new products could not be detected. Lower aliphatics, toluene, ethylbenzene, o-xylene, chlorobenzenes, and methylnaphthalenes were released more easily from pyrolysis of CPB than from PVC; amounts of benzene, styrene, and naphthalene formed were small. These results support the conclusion that recombination of chlorine atoms with the double bonds in the polyene chain takes place and that scission of the main chain may depend on the location of methylene groups isolated along the polyene chain during the thermal decomposition of PVC.  相似文献   

5.
Xu X  Zhao X  Zhang Y  Li D  Su R  Yang Q  Li X  Zhang H  Zhang H  Wang Z 《Journal of separation science》2011,34(12):1455-1462
A new microwave-accelerated derivatization method was developed for rapid determination of 13 natural sex hormones in feeds. Sex hormones were isolated from the sample matrix by ultrasonic extraction, followed by solid-phase extraction, derivatized under microwave irradiation, and then analyzed directly by gas chromatography-mass spectrometry (GC-MS) in selective ion monitoring (SIM) mode. The key parameters affecting derivatization efficiency, including microwave irradiation time, microwave power, and reaction solvent were studied. Under microwave power of 360 W and microwave irradiation for 3 min, 13 natural sex hormones were simultaneously derivatized using heptafluorobutyric acid anhydride (HFBA) as derivatization reagent. This method was applied to the determination of 13 natural sex hormones in different feed samples, and the obtained results were compared with those obtained by the traditional thermal derivatization. The recoveries from 58.1 to 111% were obtained at sex hormone concentrations of 10-300 μg/kg with RSDs ≤12.0%. The results showed that the proposed method was fast, simple, efficient and can be applied to the determination of 13 natural sex hormones in different feed samples.  相似文献   

6.
In this study a simple and fast miniaturized automated matrix solid-phase dispersion method for the sample preparation and quantitative extraction of pesticides was developed and evaluated. Only 25 mg of sample and 100 microl of organic solvent were used per analysis for this new miniaturized set-up. The extracts were subsequently analysed by GC-MS without any further purification. The method was optimized for oranges and tested for the determination of a variety of organophosphorus pesticides and a pyrethroid at concentration levels below the maximum residue levels set by the European Union and authorities in The Netherlands. The limits of detection were 4-90 microg/kg. The recoveries for pesticides in orange were 83-118% and the relative standard deviations for the total procedure were 10-13% (n=4) at the limit of quantification. The feasibility of the developed method for apple, pear and grapes was also studied. Equally good results were obtained, but for apple the washing step should be omitted.  相似文献   

7.
A simultaneous and fast method for the determination of total polyphenol index (t.p.i.) and total anthocyan index (t.a.i.) has been developed by a flow injection approach and a diode array spectrophotometer for monitoring at 280 and 520 nm, respectively. Linear ranges were obtained from 20 to 70 index units and from 20 to 500 mg l(-1) for the t.p.i. and t.a.i., respectively. The results provided by the proposed method agree with those obtained using the polyphenol index at 280 nm and the Ribereau-Gayon method for the determination of total anthocyans. The sample throughout was 25-30 samples per hour. Analytical features such as repeatability, reproducibility and detection and quantification limits as well as the results of a robustness study based on the Steiner-Younden procedure are also given.  相似文献   

8.
Summary Gravitational field-flow fractionation (GFFF) is the simplest and cheapest of field-flow fractionation (FFF) techniques, although it is still at an early development stage. The application of GFFF to the determination of particle size distribution (PSD) of silica particles used as chromatographic supports is described. The accuracy of the method is evaluated by comparing PSDs obtained by GFFF with those obtained by laser diffraction, a non-separative technique widely applied to particle characterization. It is ultimately demonstrated that a low-cost GFFF channel can simply replace the column of a standard HPLC system, allowing laboratories that are not specialized in size analysis to perform accurate PSD studies with standard HPLC expertise.  相似文献   

9.
An international interlaboratory study on the determination of ethyl carbamate in alcoholic beverages by a new HPLC-FLD and by the official GC-MS methods is presented. The aim of this study was to improve the knowledge about precision and accuracy parameters of the new method and to compare the performance of both HPLC and GC methods. Five different samples representing table wines, fortified wines (red and white), distilled spirits, and wine spirits were available for analysis by each participant. Despite the low number of participants (6), the results obtained by the laboratories using the HPLC-FLD method are comparable to those obtained by GC-MS methods. The present study emphasizes the possibility to use, as routine, a much simpler analytical method than the current reference method by GC-MS for ethyl carbamate determination in alcoholic beverages.  相似文献   

10.
A non-separative, fast and inexpensive spectrofluorimetric method based on the second order calibration of excitation-emission fluorescence matrices (EEMs) was proposed for the determination of carbaryl, carbendazim and 1-naphthol in dried lime tree flowers. The trilinearity property of three-way data was used to handle the intrinsic fluorescence of lime flowers and the difference in the fluorescence intensity of each analyte. It also made possible to identify unequivocally each analyte. Trilinearity of the data tensor guarantees the uniqueness of the solution obtained through parallel factor analysis (PARAFAC), so the factors of the decomposition match up with the analytes. In addition, an experimental procedure was proposed to identify, with three-way data, the quenching effect produced by the fluorophores of the lime flowers. This procedure also enabled the selection of the adequate dilution of the lime flowers extract to minimize the quenching effect so the three analytes can be quantified. Finally, the analytes were determined using the standard addition method for a calibration whose standards were chosen with a D-optimal design.  相似文献   

11.
The chemical composition of Matricaria chamomilla L. and Nepeta cataria L. essential oils was determined by GC-MS on an apolar stationary phase by comparison of the characteristic fragmentation patterns with those of the Wiley 275L database. The GC-MS chromatograms were compared with those obtained by fast GC equipped with a direct resistively heated column (Ultra Fast Module 5% phenyl, 5 mx 0.1 mm, 0.1 microm film thickness). Analytical conditions were optimised to reach a good peak resolution (split ratio=1:100), with analysis time lower than 5 min versus 35-45 min required by conventional GC-MS. The fast chromatographic method was completely validated for the analysis of mono- and sesquiterpene compounds. Essential oils were then fractionated by column chromatography packed with silica gel. Three main fractions with high degree of purity in E-beta-farnesene were isolated from the oil of M. chamomilla. One fraction enriched in (Z,E)-nepetalactone and one enriched in beta-caryophyllene were obtained from the oil of N. cataria. These semiochemical compounds could act as attractants of aphid's predators and parasitoids.  相似文献   

12.
In this work, for the first time, gas chromatography-mass spectrometry (GC-MS) following headspace single-drop microextraction (HS-SDME) and simultaneous derivatization was developed for fast determination of short-chain aliphatic amines (SCAAs) in water samples. In the proposed method, SCAAs in water samples were headspace extracted and concentrated by suspending a microdrop of solvent, and SCAAs extracted in the microdrop of solvent were simultaneously and rapidly reacted with pentafluorobenzaldehyde (PFBAY). The formed SCAA derivatives were analyzed by GC-MS. The HS-SDME parameters of solvent selection, solvent volume, sample temperature, extraction time and stirring rate were studied, and the method linearity, precision and detection limits, were also studied. The results show that the proposed method provided good linearity (R(2)>0.99, 5.0-500 ng/ml), low detection limit (0.6-1.1 ng/ml), and good precision (RSD value less than 10%). The proposed method was further tested by its application to quantitative analysis of SCAAs in four wastewater samples. The experiment results have demonstrated that GC-MS following HS-SDME and simultaneous derivatization is a simple, rapid and low-cost method for the determination of SCAAs in water samples.  相似文献   

13.
The combination of a programmable temperature vaporisation (PTV) injector with resistive heating GC (RH-GC), a form of fast GC, has been applied to the analysis of organophosphorus (OP) pesticides. The PTV injector was optimised in the 'at-once' solvent vent mode for the injection of ethyl acetate (10-40 microL) or ACN (10 microL). The short RH-GC column (5 m x 0.25 mm ID) with fast temperature ramps (up to 153 degrees C/ min) allowed the separation of a total of 20 OP pesticides in less than 6 min. Average recoveries between 67 and 119% were obtained for pesticides spiked at 0.01 mg/kg into apple and pear matrix. Extraction of orange juice with ACN provided higher recoveries (92-104%) for methamidophos, acephate and omethoate compared to ethyl acetate (62-73%). Results for analysis of OP pesticides in samples containing incurred residues were in good agreement with those obtained using GC-MS. The overall method was rapid, allowing 20 samples to be analysed in 4 h.  相似文献   

14.
建立了气相色谱-串联质谱法同时测定血液中双甲脒、杀虫脒及其代谢产物的分析方法。优化了样品前处理方法及气相色谱-串联质谱的分析条件,样品经固相支撑液液萃取柱(SLE)净化,乙腈-二氯甲烷(体积比1∶1)洗脱后,在多反应监测模式(MRM)下检测。结果表明,2,4-二甲基苯胺、4-氯邻甲苯胺和双甲脒在1.0~1 000 ng/m L范围内,其余目标物在2.0~1 000 ng/m L范围内线性关系良好,相关系数均大于0.99;定量下限为1.0~2.0 ng/m L,加标回收率为88.6%~113%。该方法简便、快捷、样品用量小,结果准确可靠,灵敏度高,适用于血液中6种目标物的同时检测。  相似文献   

15.
A new sampling method for the determination of polycyclic aromatic hydrocarbons (PAHs) in ambient air is described. The method is based on active sampling on sorption tubes consisting of polydimethylsiloxane (PDMS) foam, PDMS particles and a TENAX TA bed. After sampling, the solutes are quantitatively recovered by thermal desorption and analysed by capillary GC-MS. The new sampling method has been compared to the classical method using high-volume sampling on a glass fiber filter followed by polyurethane foam for 24h sampling of ambient air. Volumes enriched were 144 l on the mixed bed and 1296 m3 with the classical method. The concentrations measured using the new method were significantly higher that the values obtained using the classical method, i.e. a factor 1.2-3 for the high molecular weight PAHs and up to 35 times for naphthalene and 23 times for acenaphthene. The total toxicity equivalence value (TEQ) for PAHs was ca. two times higher compared to the conventional method, illustrating that the concentrations of PAHs in ambient air have been underestimated until now. Some figures of merit (mean value for 17 PAHs) of the method are repeatability 7.4%, detection limit 13 pg/m3, accuracy 105.6% and linearity 0.996. The method also opens interesting perspectives for the determination of other semi-volatile persistent organic pollutants (POPs) in air as illustrated with the analysis of polychlorinated biphenyls (PCBs) at a workplace during removal of transformer oil.  相似文献   

16.
A fast analytical method has been developed for the determination of nine amino acids, together with serotonin, in wine samples of different origin and vintage. The method is based on capillary electrophoresis coupled to laser-induced fluorescence detection. Separation was obtained by using a fused-silica capillary (75?μm id, 74.0?cm total length, 60.0?cm length to detector) and a background electrolyte composed of carbonate buffer (20?mM, pH 9.2), applying a 20?kV voltage. Direct hydrodynamic injection of wine samples was made after an original microwave-assisted derivatisation step with 5-(4,6-dichlorotriazinyl)aminofluorescein. Fluorescence was induced by an Ar-Ion laser, exciting at 488?nm. Good linearity (r(2) >0.9990) was obtained for all considered analytes and sensitivity was also good, with limits of detection in the 7-50?ng/mL range. The method was successfully applied for the analysis of commercial Italian wines and thus seems to be suitable for the determination of the relevant amino acids and serotonin, providing good results in terms of accuracy and precision, together with the advantage of a very fast, microwave-assisted derivatisation procedure. Future applications of the method are planned to check for wine adulterations and commercial frauds.  相似文献   

17.
李海静  刘国柱  张香文 《色谱》2018,36(8):780-785
采用全二维气相色谱-质谱联用(GC×GC-MS)考察了色谱柱系统、程序升温条件和调制周期3个主要因素对样品组分分离结果的影响,建立了煤油基吸热型碳氢燃料烃族组成的定性分析方法,并利用GC×GC-FID通过有效碳数校正因子对烃族组成进行定量。对选取的9种燃料的分析结果表明,该方法对链烷烃和环烷烃的定量结果与标准方法ASTM D2425的结果高度一致,相对误差基本均在±10%以内。利用该方法计算的碳含量结果与元素分析法相比误差均在0.5%以下。该方法无需复杂的前处理,稀释后可直接进样分析,操作简单,而且可直观地看出不同样品之间的差异,为改进燃料的性能提供了必要的分析手段。  相似文献   

18.
A rapid method for the determination of PAHs in soil samples based on their extraction with methylene chloride by sonication and subsequent separation by HPLC with fluorimetric detection is proposed. A Hypersil Green PAH column was used with a gradient of acetonitrile/water as the mobile phase, together with a program of nine excitation and emission wavelength pairs. Recoveries were in the range 70-98%, except for acenaphthene and naphthalene, at concentration levels 1.08-442 microg/kg with relative standard deviations in the range 2-15% (n = 4). Total PAHs found in soil samples were in the range 15-282 microg/kg. The results were compared with those obtained by applying the 3540 EPA method for two samples.  相似文献   

19.
Pretreatment is one of the most important steps in producing fuel ethanol from lignocellulosic biomass. Simple, fast and accurate quantification of byproducts in lignocellulosic hydrolysates is critical to optimize the pretreatment procedures, but still a challenge. In this paper, a new GC-MS (SIM) method based on a Deans switch has been developed for the determination of byproducts in a corn stover hydrolysate. The Deans switch was incorporated into a hardware system that facilitated the direct aqueous injection (DAI) on GC-MS system. Simultaneous chromatographic separation and quantification of 18 byproducts including four aliphatic acids, five furan derivatives, four phenolic compounds and five others were achieved within 45 min. The detection limits of the presented method for various byproducts were in the range of 0.007-0.832 mg/L. The within-day and between-day precisions of the method were less than 6.0% (RSD, n=6). The accuracy of the method was confirmed with recoveries of 86-128%. A lignocellulosic hydrolysate sample of corn stover was successfully analyzed using this method, with aliphatic acids and furan derivatives accounting for 89.15% of the selected total byproducts.  相似文献   

20.
A method using capillary electrophoresis with direct UV detection has been developed and validated for the determination of Turkey Red Oil (sulfonated castor oil). The highest performance with respect to separation efficiency and analysis time was achieved with 30 mM Tris (pH 8.0) buffer containing 7.5 mM HP-β-CD. The feasibility of the proposed CE method for the analysis of Turkey Red Oil surfactant in industrial water samples is demonstrated. Spiking of real samples gave recoveries between 90 and 106%. The CE results were compared with that obtained by GC-MS. It was concluded that CE can be a good alternative for fast determination of Turkey Red Oil component distribution in industrial process waters with no sample preparation other than dilution. However, the method sensitivity is not satisfactory for monitoring surfactant level in a waste effluent stream.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号