首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An enzyme sensor for the electrochemical detection of the marine toxin okadaic acid (OA) has been developed. The strategy was based on the inhibition of immobilised protein phosphatase (PP2A) by this toxin and the electrochemical measurement of the enzyme activity by the use of appropriate enzyme substrates, electrochemically active after dephosphorylation by the enzyme. Colorimetric inhibition assays have demonstrated the PP2A from human red blood cells to be more sensitive and to provide a wider linear range than the one produced by genetic engineering. Catechyl monophosphate (CMP) and p-aminophenyl phosphate (p-APP) have been tested as enzyme substrates, the former providing higher electrochemical currents at convenient working potentials (+450 mV vs. Ag/AgCl). Biosensors with 19.1 and 5.0 U of immobilised enzyme have been applied to the OA detection. Whereas the 19.1-U biosensor has provided higher electrochemical currents and more reliable determinations, the 5.0-U one has attained a lower 50% inhibition coefficient (IC50) value (22.19 in front of 154.84 μg L−1) and a larger working range (2.69-171.87 in front of 42.97-171.87 μg L−1). The analysis of toxicogenic dinoflagellate extracts with both biosensors and the comparison with the colorimetric assay and liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) have demonstrated the applicability of the developed electrochemical devices as screening biotools for the assessment of the toxicity of a sample.  相似文献   

2.
Sassolas A  Catanante G  Fournier D  Marty JL 《Talanta》2011,85(5):2498-2503
A colorimetric protein phosphatase (PP) inhibition test for the detection of microcystin-LR (MC-LR) has been developed. Three PP2As, one recombinant and two natural versions, as well as one PP1 produced by molecular engineering, were tested. First, assays were performed using the enzymes in solution to compare their sensitivity to MC-LR. The PP2A purchased from ZEU Immunotec and PP1 appeared more sensitive to the toxin than the other enzymes. With PP2A from ZEU Immunotec, the colorimetric test showed a detection limit of 0.0039 μg L−1 and an IC50 value of 0.21 μg L−1. With PP1, the assay gave a detection limit of 0.05 μg L−1 and an IC50 value of 0.56 μg L−1. Therefore, this assay allowed the detection of lower microcystin-LR (MC-LR) concentrations than the maximum level (1 μg L−1) recommended by the World Health Organisation (WHO).The main drawback of this PP-based approach in solution is poor enzyme stabilisation. To overcome this problem, enzymes were entrapped within either a photopolymer or an agarose gel. PP2A from ZEU Immunotec and PP1 were immobilised at the bottom of microwells. The agarose-based tests performed better than the photopolymer-based assay for all of the enzymes. Therefore, the agarose gel is a good candidate to replace the photopolymer, which is generally used in PP-immobilising membranes. The assays based on enzyme-entrapping agarose gels showed detection limits equal to 0.17 μg L−1 and 0.29 μg L−1 with immobilised PP2A from ZEU and PP1, respectively. In view of these performances, these tests can potentially be used for monitoring water quality.  相似文献   

3.
A colorimetric protein phosphatase inhibition assay (PPI assay), a commercial enzyme-linked immunosorbent assay (ELISA) test and different HPLC methods using UV detection were compared for the detection of cyanobacterial hepatotoxins, microcystins (MCYST) and nodularin. The suitability of the methods to detect different toxin variants was evaluated by using pure toxins and laboratory cultures as well as water and bloom samples of toxic cyanobacteria. The emphasis of the study was on the analysis of polar demethyl microcystin variants that are common in nature but for which there exist no commercial standards. The IC50 values of MCYST-LR for the PPI assay and the ELISA test were 2.2-2.5 and 0.26-0.38 μg l−1, respectively. The most important factors that decreased toxin recovery in sample treatment were the use of C18 cartridges and polypropylene containers. Good recoveries of toxins were obtained by using hydrophilic-lipophilic balanced (Oasis HLB, Waters) cartridges for concentrating the samples. The results obtained with the PPI assay, the ELISA test and HPLC correlated quantitatively well with the exception of [d-Asp3] microcystins. Concentrations of [d-Asp3]MCYST-RR measured with the PPI assay were only 5% of those obtained by the ELISA test and HPLC. Concentrations of hydrophobic microcystin variants were lower when analysed with ELISA than with the other methods. The World Health Organisation (WHO) has set a guideline value of 1 μg l−1 for the world-wide most common microcystin variant, MCYST-LR in drinking water. Since the quantitative ranges of the PPI assay and the ELISA test are within microcystin concentrations in natural waters, and both tests are easy to perform, they show potential for routine use in the screening and monitoring of microcystins from drinking water supplies and from recreational waters.  相似文献   

4.
Biosensor immunoassays for the detection of bisphenol A   总被引:1,自引:0,他引:1  
Bisphenol A (BPA) is a xenoestrogen found in the environment, in consequence, for the biosensor detection of BPA we raised antibodies (polyclonal (PAbs) and monoclonal (MAbs)) against a structural analogue of BPA, 4,4 bis-(4-hydroxyphenyl) valeric acid (BVA). The kinetics of the MAb-BPA interaction were evaluated and the MAb providing the highest affinity was directly immobilized onto the sensor chip surface to evaluate a direct assay. Afterwards, the performance of the MAbs and the PAbs was compared in an inhibition assay using a BVA-coated chip.The highest sensitivity (limit of detection (LOD) of 0.4 μg L−1) was obtained with MAb 12 in the direct assay. However, the inhibition assay was the most robust and the PAbs showed the highest sensitivity (LOD of 0.5-1 μg L−1). The antibodies were specific for BVA and BPA as only minor cross-reactivities were found toward structurally related compounds or other endocrine disruptors. In the inhibition assay (with a run time of 6 min), water samples spiked with BPA at different levels (0.5-50 μg L−1) resulted in recoveries varying between 68% and 121%. The sensitivity of the inhibition assay could be improved 40 times (LOD of 0.03 μg L−1 with the Mab 12-based assay) using solid phase extraction (SPE).  相似文献   

5.
Microcystins (MCs) are a group of closely related toxic cyclic heptapeptides produced by common cyanobacteria (blue-green algae), and microcystin-leucine-arginine (MC-LR) is among the most frequent and most toxic microcystin congeners. In this study, a free amino group was introduced to MC-LR at its seventh amino acid residue with 2-mercaptoethylamine, and the product aminoethyl-MC-LR was coupled to bovine serum albumin (BSA) and horseradish peroxidise (HRP) by glutaraldehyde to be complete antigen (MC-LR-BSA) and labelled hapten (MC-LR-HRP), respectively. Polyclonal antibodies against MC-LR were generated by immunization with MC-LR-BSA. A direct competitive enzyme-linked immunosorbent assay (dc-ELISA) was established to detect the MCs in waters, which showed a good cross-reactivity with MC-LR, MC-RR, MC-YR, MC-LF, MC-LW and nodularin, and have a detection limit for MC-LR 0.12 μg L−1, the 50% inhibition concentration (IC50) for MC-LR was 0.63 ± 0.06 μg L−1 and the quantitative detection range was from 0.17 to 2.32 μg L−1, the analysis result of water samples showed good recovery and reliability. So the comprehensive and reliable dc-ELISA will well potentially suit for sensitive analysis for total MCs in drinking as well as resource water samples.  相似文献   

6.
An electrochemical method based on a cytochrome c biosensor was developed, for the detection of selected arsenic and cyanide compounds. Boron doped diamond (BDD) electrode was used as a transducer, onto which cytochrome c was immobilised and used for direct determination of Prussian blue, potassium cyanide and arsenic trioxide. The sensitivity as calculated from cyclic voltammetry (CV) and square wave voltammetry (SWV), for each analyte in phosphate buffer (pH = 7) was found to be in the range of (1.1–4.5) × 10−8 A μM−1 and the detection limits ranged from 4.3 to 9.1 μM. The biosensor is therefore able to measure significantly lower than current Environmental Protection Agency (EPA) and World Health Organisation (WHO) guidelines, for these types of analytes. The protein binding was monitored as a decrease in biosensor peak currents by SWV and as an increase in biosensor charge transfer resistance by electrochemical impedance spectroscopy (EIS). EIS provided evidence that the electrocatalytic advantage of BDD electrode was not lost upon immobilisation of cytochrome c. The interfacial kinetics of the biosensor was modelled as equivalent electrical circuit based on electrochemical impedance spectroscopy data. UV–vis spectroscopy was used to confirm the binding of the protein in solution by monitoring the intensity of the soret bands and the Q bands. FTIR was used to characterise the protein in the immobilised state and to confirm that the protein was not denatured upon binding to the pre-treated bare BDD electrode. SNFTIR of cyt c immobilised at platinum electrode, was used to study the effect of oxidation state on the surface bond vibrations. The spherical morphology of the immobilised protein, which is typical of native cytochrome c, was observed using scanning electron microscopy (SEM) and confirmed the immobilisation of the cytochrome c without denaturisation.  相似文献   

7.
A novel binding phase was developed for use in diffusive gradients in thin-film (DGT) sampling for Cu(II) by employing methylthymol blue as a chelating and chromogenic agent. Methylthymol blue was adsorbed onto beads of Dowex 1 × 8 resin (200-400 mesh) and the resin beads were then immobilised onto an adhesive disc. Analysis of exposed binding discs by either UV-vis spectrophotometry or computer imaging densitometry provided robust quantification of adsorbed Cu(II) in the 0.2-1 μg cm−2 range, allowing detection at μg L−1 concentrations in the test solution (ca. 17 μg L−1 for a 24 h deployment), and in good agreement with established DGT theory. The method was shown to be a potential replacement for binding phases based on Chelex 100 where a colorimetric response to a specific metal is desired.  相似文献   

8.
Two non-electroactive biomarkers methylglyoxal (MGo) and glyoxal (Go) in urine and environmental water samples were determined for the first time by capillary electrophoresis with amperometric detection (CE-AD) after derivatizing with an electroactive compound 2-thiobarbituric acid. Experimental conditions of derivatization and CE-AD detection were optimized. Highly linear response was obtained for these two biomarkers over three orders of magnitude with good correlation (r2 > 0.999). The limits of detection (LODs) and limits of quantitation (LOQs) of MGo and Go were 0.2 μg L−1 and 1.0 μg L−1, 0.5 μg L−1 and 2.0 μg L−1, respectively. The average recovery and relative standard deviation (RSD) were within the range of 90.9–101.3% and 0.7–2.2%, respectively. The proposed CE-AD method provides a reliable and sensitive quantitative evaluation of MGo and Go in real sample matrices by employing relatively simple and inexpensive instrument.  相似文献   

9.
Due to the potentially adverse effects of the chromium (VI) on the human health and also on the environment, the quantitative determination of Cr(VI) is of particular interest. This work herein reports a facile, selective and rapid colorimetric determination of Cr(VI) based on the peroxidase substrate-2,2′-azino-bis(3-ethylbenzo-thiazoline-6-sulfonic acid) diammonium salt (ABTS) as the color developing agent. ABTS, which was usually acted as peroxidase substrate for the enzyme linked immunosorbent assay, is used here for the first time to fabricate the “signal-on” colorimetric Assay for Cr(VI). The ABTS was chosen instead of the commonly used 1,5-diphenylcarbazide (DPC) due to its good solubility, stability, sensitivity and low background. This method provided a convenient colorimetric detection of Cr(VI) with a wider linear range from 8.33 μg L−1 to 1.25 mg L−1 by recording the absorption spectra at the wavelength of 419 nm and a low detection limit of 7.87 μg L−1. In addition, the entire detection takes less than 10 min.  相似文献   

10.
Alireza Mohadesi 《Talanta》2007,71(2):615-619
A differential pulse anodic stripping voltammetric method was developed for the determination of Ag(I) at a 3-amino-2-mercapto quinazolin-4(3H)-one modified carbon paste electrode. The analysis procedure consisted of an open circuit accumulation step in stirred sample solution for 12 min. This was followed by medium exchange to a clean solution where the accumulated Ag(I) was reduced for 15 s in −0.6 V. Subsequently an anodic potential scan was effected from −0.2 to +0.2 V to obtain the voltammetric peak. The detection limit of silver(I) was 0.4 μg L−1 and R.S.D. for 10, 100 and 200 μg L−1 silver(I) were 2.4, 1.8 and 1.3%, respectively. The calibration curve was linear for 0.9-300 μg L−1 silver(I). Many coexisting ions had little or no effect on the determination of silver(I). The procedure was applied to determination of silver(I) in X-ray photographic films and natural waters. In X-ray photographic film samples, the results have compared to those obtained by atomic absorption spectroscopy.  相似文献   

11.
The possibility of applying antimony-film modified glassy carbon electrode in sequential-injection analysis (SIA) was investigated with the objective of determining Pb(II) and Cd(II) by anodic stripping voltammetry (ASV). The conditions of antimony-film deposition concerning composition of the plating/carrier solutions, concentrations of Sb(III) and hydrochloric acid, effects of different supporting electrolyte salts, and plating potential were optimized. It was found that the antimony-film deposition on glassy carbon substrate in a sample solution consisting of 750 μg L−1 Sb(III), 0.5 mol L−1 HCl at −1.5 V (vs. Ag/AgCl/3 mol L−1 KCl) yielded a modified electrode suitable for the determination of Pb(II) and Cd(II) at the μg L−1 level. The reproducibility of the analytical signals was characterized by a relative standard deviation lower than 2.8%, and the calculated values of detection limits were 1.2 μg L−1 for Pb(II) and 1.4 μg L−1 for Cd(II). The presence of KSCN in the sample solution offers the possibility of detecting ions with more negative oxidation potentials like Zn(II), Mn(II) or Cr(III). The developed SIA-ASV procedure was compared with the commonly used batch method, and its applicability was tested on a spiked tap water sample.  相似文献   

12.
A HPLC method using a coulometric electrode array detector (CEAD) to analyse 4-ethylcatechol in wine was established. The procedure does not require any sample preparation or analyte derivatisation and performs chromatographic separation in a short time. The assay method is linear up to 1520 μg L−1 and precise (R.S.D. < 3%), with limits of detection and quantitation of 1.34 μg L−1 and 2.2 μg L−1, respectively. Recoveries in spiked wine samples ranged from 95% to 104% with a median value of 102% and matrix effects were not observed. The method was applied to the evaluation of the concentration of 4-EC in 250 commercial Italian wines. The red wines analysed had median, 75° percentile and maximum values of 37 μg L−1, 89 μg L−1 and 1610 μg L−1, respectively. For Sangiovese-based wines the mean ratios of 4-EP and 4-EG to 4-EC were 3.7:1 and 0.7:1, respectively. The feasibility of a cheaper fluorimetric approach to 4-EC quantification was investigated.  相似文献   

13.
Microcystins (MC) are cyanobacterial hepatotoxins responsible for animal-poisoning and human health incidents. Immunoassays provide a sensitive and fast means to detect these toxins, but cross-reactivity (CR) characteristic of different antibodies was variable. Here, we have produced and characterized a monoclonal antibody (Clone MC8C10) with highly specificity against the most frequent and most toxic variant of microcystins, MC-LR. MC8C10 is more specific against MC-LR among the reported antibodies before. The immunogen was synthesized from the modified MC-LR and bovine serum albumin (BSA). An indirect competitive enzyme-linked immunosorbent assay (ic-ELISA) with MC8C10 was established to detect the MCs in waters, which showed highly specificity with MC-LR, and have a detection limit for MC-LR 0.1 μg L−1, the 50% inhibition concentration (IC50) for MC-LR was 1.8 ± 0.1 μg L−1 and the quantitative detection range was from 0.3 to 10 μg L−1. The [4-arginine] microcystins and the nodularin-R showed lower cross-reactivates (CR < 10%), and other MCs such as MC-LF and MC-LW are not recognized (CR < 10−4). The analysis results of real water samples with ic-ELISA showed that all the coefficients of variation were less than 15%, and the recovery was (100.3 ± 5.9)%. So the highly specific ic-ELISA will commendably suit for sensitive analysis for MC-LR in surface water as well as drinking water.  相似文献   

14.
A fast, economic and sensitive chemiluminescence (CL) method has been developed for the analysis of cetrizine hydrochloride (CET) in pharmaceutical formulations and in biological fluids. The CL method is based on the oxidation of tris(2,2′-bipyridyl)ruthenium(II) (Ru (bipy)32+) by peroxydisulphate in a two-chip device. Up to 180 samples can be analysed per hour, consuming only minute quantities of reagents. Three instrumental setups were tested to find the most economical, sensitive and high throughput setup. In the first setup, a continuous flow of sample and CL reagents was used, whereas in the second setup, a fixed volume (2 μL) of (Ru (bipy)32+) was introduced into a continuous infusion of peroxydisulphate and the sample. In the third design, a fixed volume of sample (2 μL) was injected while the CL reagents were continuously infused. Compared to the first setup, a 200% signal enhancement was observed in the third setup. Various parameters that influence the CL signal intensity, including pH, flow rates and reagent concentrations, were optimized. A linear response was observed over the range of 50 μg L−1 to 6400 μg L−1 (R2 = 0.9959) with RSD values of 1.1% (n = 15) for 1000 μg L−1. The detection limit was found to be 15 μg L−1 (S/N = 3). The amount of consumed sample was only 2 μL, from which the detected amount of CET was found to be 6.5 × 10−14 mol. This procedure was successfully applied to the analysis of CET in pharmaceutical formulations and biological fluids.  相似文献   

15.
An imidazole derivative, 2-(2′-pyridyl)imidazole (PIMH), was developed as a colorimetric probe for the qualitative analysis of Fe2+ in aqueous solution. PIMH was then used to post-functionalize poly(vinylbenzyl chloride) (PVBC) nanofibers after electrospinning so as to afford a solid state colorimetric probe. Upon treatment with Fe2+ the probe displayed a distinctive color change both in liquid and solid platforms. The linear dynamic range for the colorimetric determination of Fe2+ was 0.0988–3.5 μg mL−1. The ligand showed a high chromogenic selectivity for Fe2+ over other cations with a detection limit of 0.102 μg mL−1 in solution (lower than the WHO drinking water guideline limit of 2 mg L−1), and 2 μg mL−1 in the solid state. The concentration of Fe2+ in a certified reference material (Iron, Ferrous, 1072) was found to be 2.39 ± 0.01 mg L−1, which was comparable with the certified value of 2.44 ± 0.12 mg L−1. Application of the probe to real samples spiked with Fe2+ achieved recoveries of over 97% confirming accuracy of the method and its potential for on-site monitoring.  相似文献   

16.
Freshwater and brackish microalgal toxins, such as microcystins, cylindrospermopsins, paralytic toxins, anatoxins or other neurotoxins are produced during the overgrowth of certain phytoplankton and benthic cyanobacteria, which includes either prokaryotic or eukaryotic microalgae. Although, further studies are necessary to define the biological role of these toxins, at least some of them are known to be poisonous to humans and wildlife due to their occurrence in these aquatic systems. The World Health Organization (WHO) has established as provisional recommended limit 1 μg of microcystin-LR per liter of drinking water. In this work we present a microsphere-based multi-detection method for five classes of freshwater and brackish toxins: microcystin-LR (MC-LR), cylindrospermopsin (CYN), anatoxin-a (ANA-a), saxitoxin (STX) and domoic acid (DA). Five inhibition assays were developed using different binding proteins and microsphere classes coupled to a flow-cytometry Luminex system. Then, assays were combined in one method for the simultaneous detection of the toxins. The IC50's using this method were 1.9 ± 0.1 μg L−1 MC-LR, 1.3 ± 0.1 μg L−1 CYN, 61 ± 4 μg L−1 ANA-a, 5.4 ± 0.4 μg L−1 STX and 4.9 ± 0.9 μg L−1 DA. Lyophilized cyanobacterial culture samples were extracted using a simple procedure and analyzed by the Luminex method and by UPLC–IT-TOF-MS. Similar quantification was obtained by both methods for all toxins except for ANA-a, whereby the estimated content was lower when using UPLC–IT-TOF-MS. Therefore, this newly developed multiplexed detection method provides a rapid, simple, semi-quantitative screening tool for the simultaneous detection of five environmentally important freshwater and brackish toxins, in buffer and cyanobacterial extracts.  相似文献   

17.
An analytical methodology has been developed for the simultaneous extraction of 13 phenolic compounds, including chlorophenols (CPs), nitrophenols (NTPs), cresols and alkylphenols (APs) in different types of wastewater (WW) effluents. A solid-phase extraction (SPE) method has been optimized prior to the determination by gas chromatography coupled to triple quadrupole tandem mass spectrometry (GC-QqQ-MS/MS). Due to the complexity of the matrix, a comparison study of matrix-matched-calibration (MMC) and standard addition calibration (SAC) was carried out for quantification purposes. The optimized procedure was validated using the SAC approach since it provided the most adequate quantification results (in terms of recovery and precision values). Recoveries were in the range 60-135% (0.5 μg L−1), 70-115% (1 μg L−1), and 78-120% (5 μg L−1), with precision values (expressed as relative standard deviation, RSD) ≤30% (except for 2-nitrophenol) involving intra-day and inter-day precision studies. Limits of detection (LODs) and quantification (LOQs) were also evaluated, and LOQs ranged from 0.03 μg L−1 to 2.5 μg L−1. The proposed method was applied to the analysis of 8 real WW effluent samples, finding some phenolic compounds (e.g. 2-chlorophenol, 2,4,6-trichlorophenol and 4-tert-octylphenol) at concentrations higher than the established LOQs.  相似文献   

18.
A simple, rapid and sensitive sensing platform for the detection of As(III) has been fabricated in neutral media based on the mercaptoethylamine modified Au electrode. A wide detection range of 0.2–300 μg L−1 and a low detection limit of 0.02 μg L−1 were obtained with a preconcentration time of 100 s under optimal conditions. Compared with previous studies, this work shows obvious advantages that it not only suppresses the Cu(II) interference, but also can detect the As(III) in natural water samples at the original pH avoiding high concentration acidic media. Moreover, the practical application of the proposed method was verified in the lake water sample determination.  相似文献   

19.
Competitive electrochemical enzyme-linked immunosorbent assays based on disposable screen-printed electrodes have been developed for quantitative determination of ochratoxin A (OTA). The assays were carried out using monoclonal antibodies in the direct and indirect format. OTA working range, I50 and detection limits were 0.05-2.5 and 0.1-7.5 μg L−1, 0.35 (±0.04) μg L−1 and 0.9 (±0.1) μg L−1, 60 and 100 μg L−1 in the direct and indirect assay format, respectively. The immunosensor in the direct format was selected for the determination of OTA in wheat. Samples were extracted with aqueous acetonitrile and the extract analyzed directly by the assay without clean-up. The I50 in real samples was 0.2 μg L−1 corresponding to 1.6 μg/kg in the wheat sample with a detection limit of 0.4 μg/kg (calculated as blank signal −3σ). Within- and between-assay variability were less than 5 and 10%, respectively. A good correlation (r = 0.9992) was found by comparative analysis of naturally contaminated wheat samples using this assay and an HPLC/immunoaffinity clean-up method based on the AOAC Official Method 2000.03 for the determination of OTA in barley.  相似文献   

20.
A gas chromatography–tandem mass spectrometric (GC–MS/MS) method has been established for the determination of cyanide in surface water. This method is based on the derivatization of cyanide with 2-(dimethylamino)ethanethiol in surface water. The following optimum reaction conditions were established: reagent dosage, 0.7 g L−1 of 2-(dimethylamino)ethanethiol; pH 6; reaction carried out for 20 min at 60 °C. The organic derivative was extracted with 3 mL of ethyl acetate, and then measured by using GC–MS/MS. Under the established conditions, the detection and quantification limits were 0.02 μg L−1 and 0.07 μg L−1 in 10-mL of surface water, respectively. The calibration curve had a linear relationship relationship with y = 0.7140x + 0.1997 and r2 = 0.9963 (for a working range of 0.07–10 μg L−1) and the accuracy was in a range of 98–102%; the precision of the assay was less than 7% in surface water. The common ions Cl, F, Br, NO3, SO42−, PO43−, K+, Na+, NH4+, Ca2+, Mg2+, Ba2+, Mn4+, Mn2+, Fe3+, Fe2+ and sea water did not interfere in cyanide detection, even when present in 1000-fold excess over the species. Cyanide was detected in a concentration range of 0.07–0.11 μg L−1 in 6 of 10 surface water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号