首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Four simple, rapid, accurate, precise, reliable and economical spectrophotometric methods have been proposed for simultaneous determination of salbutamol sulphate (SS), bromhexine hydrochloride (BH) and etofylline (ET) in pure and commercial formulations without any prior separation or purification. They were first derivative zero crossing spectrophotometry (method 1), simultaneous equation method (method 2), derivative ratio spectra zero crossing method (method 3) and double divisor ratio spectra derivative method (method 4). The ranges for SS, BH and ET were found to be 1-35 μg mL−1, 4-40 μg mL−1 and 5-80 μg mL−1. For methods 1 and 2, the values of limit of detection (LOD) were 0.2314 μg mL−1, 0.4865 μg mL−1 and 0.2766 μg mL−1 and the values of limit of quantitation (LOQ) were 0.7712 μg mL−1, 1.6217 μg mL−1 and 0.9221 μg mL−1 for SS, BH and ET, respectively. For method 3, LOD values were 0.3297 μg mL−1, 0.2784 μg mL−1 and 0.7906 μg mL−1 and LOQ values were 0.9325 μg mL−1, 0.9282 μg mL−1 and 2.6352 μg mL−1 for SS, BH and ET, respectively. For method 4, LOD values were 0.3161 μg mL−1, 0.2495 μg mL−1 and 0.2064 μg mL−1 and LOQ values were 0.9869 μg mL−1, 0.8317 μg mL−1 and 0.6879 μg mL−1 for SS, BH and ET. The precision values were less then 2% R.S.D. for all four methods. The common excipients and additives did not interfere in their determinations. The results obtained by the proposed methods have been statistically compared by means of Student t-test and by the variance ratio F-test.  相似文献   

2.
Gao L  Wu L  Li Q 《Analytica chimica acta》2008,626(2):174-179
A novel and simple spectrophotometric method for the determination of Captopril with sodium 1,2-naphthoquinone-4-sulfonate is established in this paper. The detailed reaction mechanism is proposed and discussed. It is based on the fact that captopril can catalyze the reaction between sodium 1,2-naphthoquinone-4-sulfonate and hydroxyl ion to form 2-hydroxy-1,4-naphthoquinone in buffer solution of pH 13.00. Beer's law is obeyed in a range of 0.64-80 μg mL−1 at the maximal absorption wavelength of 442 nm. The equation of linear regression is A = 0.05815 + 0.00589C (μg mL−1), with a linear regression correlation coefficient of 0.9981. The detection limit is 0.3 μg mL−1, R.S.D. is 0.77% and the recovery rate is in range of 96.0-103.8%. Furthermore, the method has been validated and successfully applied to the determination of captopril in pharmaceutical samples.  相似文献   

3.
A simple and rapid reversed-phase HPLC-UV method was developed for the determination of triterpenic acids in the crude extract of Prunellae Spica. Five triterpenic acids were extracted and isolated from P. Spica as marker compounds for use in the quality control of herbal medicines. Various solvent extraction techniques were evaluated, and the greatest efficiency was observed with sonication in 100% ethanol. Elemental compositions of the five marker compounds were determined by high-resolution mass spectroscopy. The dynamic range of the HPLC-UV method depended on the specific analyte, and acceptable quantitation was obtained between 10 and 250 μg mL−1 for oleanolic acid, between 10 and 300 μg mL−1 for ursolic acid, between 3 and 75 μg mL−1 for 2α,3α,24-trihydroxyolean-12en-28oic acid, between 5 and 100 μg mL−1 for euscaphic acid, and between 5 and 100 μg mL−1 for 2α,3α-dihydroxyurs-12en-28oic acid. The method was deemed satisfactory by inter- and intra-day validation and exhibited both high accuracy and precision (relative standard deviation <9.4%). Overall limits of quantitation and detection were approximately 0.5-2.5 μg mL−1 at a signal-to-noise ratio (S/N) of 3 and were about 3.0-10.0 μg mL−1 at a S/N of 10. In addition, principal component analysis (PCA) was performed on the analytical data of 15 different P. Spica samples in order to classify samples collected from different regions.  相似文献   

4.
A new reversed-phase high performance liquid chromatography with resonance Rayleigh scattering detection (HPLC-RRS) was developed for simultaneous separation and determination of four tetracycline antibiotics (TCs). A good chromatographic separation among the compounds was achieved using a Synergi Fusion-RP column (150 mm × 4.6 mm; 4 μm) and a mobile phase consisting of methanol-acetonitrile-oxalic acid (5 mM) at the flow rate of 0.8 mL min−1. Column temperature was 30 °C. The RRS signal was detected at λex = λem = 370 nm. The recoveries of sample added standard ranged from 95.3% to 103.5%, and the relative standard deviation was below 2.79%. A detection limit of 2.12-5.12 μg mL−1 was reached and a linear range was found between peak height and concentration in the range of 10.36-518.0 μg mL−1 for oxytetracycline (OTC), 12.11-605.5 μg mL−1 for tetracycline (TC), 11.79-589.5 μg mL−1 for chlortetracycline (CTC) and 10.32-516.0 μg mL−1 for doxycycline (DC). The linear regression coefficients were all above 0.999. The method has been applied successfully to the determination of OTC, TC, CTC, DC in pharmaceutical formulations and in honey. The method was simple, rapid and showed a better linear relation and high repeatability.  相似文献   

5.
Jiang ZL  Zhang BM  Liang AH 《Talanta》2005,66(3):783-788
A new simple, selective and sensitive method for the determination of trace chlorine dioxide in water has been developed, based on the oxidation by chlorine dioxide to reduction the fluorescence of rhodamine dyes in ammonia-ammonium chloride buffer solution. Four rhodamine dyes systems such as rhodamine S, rhodamine G, rhodamine B and butyl-rhodamine B were tested. The rhodamine S system is the best, with a linear range of 0.0060-0.450 μg mL−1 and a detection limit of 0.0030 μg mL−1 ClO2. It was applied to the determination of chlorine dioxide in synthetic samples and real samples, with satisfactory results. This method has good selectivity, especially, other chlorine species such as chlorine, hypochlorite, chlorite and chlorate do not interfere the determination. The mechanism of fluorescence reduction was also considered.  相似文献   

6.
The chemiluminescent behaviour of captopril when reacted with a common oxidant, potassium permanganate in different acidic media is described, using the stopped-flow technique in a continuous-flow system. A 22 bit analogue-to-digital converter that acquires analogue signals at −10 and +10 V and allows the power supply to the peristaltic pump to be interrupted is used in the time-resolved chemiluminescence manifold to ensure rapid, efficient mixing of chemiluminescent reagent and sample immediately before reaching the detector; this results in high precision and detectability, particularly with fast, short-lived emissions.The optimum chemical conditions for the chemiluminescence emission were investigated. It was found that a weak CL emission was emitted during the oxidation of this drug with potassium permanganate in acidic solution. The effect of common emission enhancers such as formic acid, formaldehyde, glutaraldehyde, acetaldehyde, quinine, fluorescein, rhodamine B and rhodamine 6G was studied. The parameters selected were 4.0 mol L−1 sulphuric acid, 0.25 mmol L−1 permanganate and 0.75 mol L−1 formaldehyde.Four quantitative parameters adjustable via software settings, two of them typically kinetic parameters, such as rate of the light-development reaction and rate of the light-decay reaction, and the other conventional parameters, such as maximum emission intensity and total emission area, were used to obtain linear calibration graphs with each measurement parameter. The detection limits ranged from 0.011 to 0.026 μg mL−1 and R.S.D. values (n = 10) of 1.21-3.93 at a 0.50 μg mL−1 and 2.01-3.41 at a 1.60 μg mL−1 concentration levels were obtained. The method was satisfactorily applied to the determination of captopril in pharmaceutical preparations.  相似文献   

7.
The directly suspended droplet microextraction (DSDME) technique coupled with the capillary gas chromatography-flame ionization detector (GC-FID) was used to determine BTEX compounds in aqueous samples. The effective parameters such as organic solvent, extraction time, microdroplet volume, salt effect and stirring speed were optimized. The performance of the proposed technique was evaluated for the determination of BTEX compounds in natural water samples. Under the optimal conditions the enrichment factors ranged from 142.68 to 312.13, linear range; 0.01-20 μg mL−1, limits of detection; 0.8-7 ng mL−1 for most analytes. Relative standard deviations for 0.2 μg mL−1 of BTEX in water were in the range 1.81-2.47% (n = 5). The relative recoveries of BTEX from surface water at spiking level of 0.2 μg mL−1 were in the range of 89.87-98.62%.  相似文献   

8.
Based on CdTe/CdS quantum dots (CdTe/CdS QDs) fluorescence (FL) reversible control, a new and sensitive FL sensor for determination of anthraquinone (AQ) anticancer drugs (adriamycin and daunorubicin) and herring sperm DNA (hsDNA) was developed. Under the experimental conditions, FL of CdTe/CdS QDs can be effectively quenched by AQ anticancer drugs due to the binding of AQ anticancer drugs on the surface of CdTe/CdS QDs and photoinduced electron transfer (PET) process from CdTe/CdS QDs to AQ anticancer drugs. Addition of hsDNA afterwards brought the restoration of CdTe/CdS QDs FL intensity, as AQ anticancer drugs peeled off from the surface of CdTe/CdS QDs and embedded into hsDNA double helix structure. The liner ranges and the detection limits of FL quenching methods for two AQ anticancer drugs were 0.33-9 μg mL−1 and 0.09 μg mL−1 for ADM and 0.15-9 μg mL−1 and 0.04 μg mL−1 for DNR, respectively. The restored FL intensity was proportional to concentration of hsDNA in the range of 1.38-28 μg mL−1and the detection limit for hsDNA was 0.41 μg mL−1. It was applied to the determination of AQ anticancer drugs in human serum and urine samples with satisfactory results. The reaction mechanism of CdTe/CdS QDs FL reversible control was studied.  相似文献   

9.
Zhao J  Chen Z  Li X  Pan J 《Talanta》2011,85(5):2614-2619
A microfluidic chip manufactured from glass substrate and indium tin oxide (ITO) coated glass use for contactless conductivity detection was developed. The detecting electrodes were fabricated by screen-printing and chemical etching methods using an ITO-coated glass wafer. Then, the glass substrate containing separation channels was bonded with the bare side of the processed ITO-coated glass, thus producing an electrophoresis chip integrated with contactless conductivity detector. The prepared microchip displayed considerable stability and reproducibility. Sensitive response was obtained at optimal conditions (including the gap between electrodes, excitation frequency, and excitation voltage). The feasibility of this microfluidic device was examined by detection of inorganic ions, and further demonstrated by the quantification of aminopyrine and caffeine in a compound pharmaceutical. The two ingredients can be completely separated within 1 min. The detection limits were 8 μg mL−1 and 3 μg mL−1, respectively; with the correlation coefficient of 0.996-0.998 in the linear range from 10 μg mL−1 to 800 μg mL−1. The results have showed that the present method is sensitive, reliable and fast.  相似文献   

10.
Chen L  Chen W  Ma C  Du D  Chen X 《Talanta》2011,84(1):104-108
A novel solid-phase microextraction (SPME) fiber coated with multiwalled carbon nanotubes/polypyrrole (MWCNTs/Ppy) was prepared with an electrochemical method and used for the extraction of pyrethroids in natural water samples. The results showed that the MWCNTs/Ppy coated fiber had high organic stability, and remarkable acid and alkali resistance. In addition, the MWCNTs/Ppy coated fiber was more effective and superior to commercial PDMS and PDMS/DVD fibers in extracting pyrethroids in natural water samples. Under optimized conditions, the calibration curves were found to be linear from 0.001 to 10 μg mL−1 for five of the six pyrethroids studied, the exception being fenvalerate (which was from 0.005 to 10 μg mL−1), and detection limits were within the range 0.12-0.43 ng mL−1. The recoveries of the pyrethroids spiked in water samples at 10 ng mL−1 ranged from 83 to 112%.  相似文献   

11.
In this work, chemiluminescence (CL) behaviors of two selected phenothiazines, namely promazine and fluphenazine hydrochloride, were investigated for their simultaneous determination using oxidation of Ru(bipy)32+ by Ce4+ ions in acidic media. This method is based on the kinetic distinction of the CL reactions of fluphenazine and promazine with Ru(bipy)32+ and Ce4+ system in a sulfuric acid medium. Least square support vector regression models were constructed for relating concentrations of both compounds to their CL profiles. The parameters of the model consisting of σ2 and γ were optimized using all possible combinations of σ2 and γ to select the model with the minimum root mean square cross validation. Under optimized conditions, the univariate calibration curve was linear over the concentration ranges of 0.4-30.0 μg mL−1 and 0.07-5.0 μg mL−1 with detection limits of 0.1 μg mL−1 and 0.04 μg mL−1 for promazine and fluphenazine, respectively. The influence of potential interfering substances on the determination of promazine and fluphenazine were studied. The proposed method was used for simultaneous determination of both compounds in synthetic mixtures and in spiked human plasma.  相似文献   

12.
A suitable method for the gas chromatographic determination of 10 characteristic carbonyls in biological and oil samples based on the in-drop formation of hydrazones by using 2,4,6-trichlorophenylhydrazine (TCPH), has been developed. The derivatisation-extraction procedure was optimized separately for aqueous and oil samples with respect to the appropriate organic drop solvent, drop volume, in-drop TCPH concentration, sample stirring rate, temperature during single-drop microextraction (SDME), reaction time and headspace-to-sample volume ratio. The optimization showed differentiation of optimum values between the studied matrices. The limits of detection were found to range from 0.001 to 0.003 μg mL−1 for the aqueous biological samples and from 0.06 to 0.20 μg mL−1 for the oil samples. The limits of quantification were in the range of 0.003-0.010 μg mL−1 and 0.020-0.059 μg mL−1 for aqueous and oil samples, respectively. The overall relative standard deviations of the within-day repeatability and between-day reproducibility were <4.4% and <8.2% for the aqueous biological samples and <3.9% and <7.4% for the oxidized oil samples.  相似文献   

13.
Fu S  Liu Z  Liu S  Liu J  Yi A 《Analytica chimica acta》2007,599(2):271-278
In pH 2.8-3.8 BR buffer medium, the third generation cephalosporin antibiotics (TGCs) such as ceftazidime (CZD), ceftriaxone (CTRX), cefoperazone (CPZ), and cefotaxime (CFTM) react with palladium(II) (Pd(II)) to form 1:2 yellowish-brown cationic chelates, which further react with 4, 5-dibromofluorescein (DBF) to form 1:3 brown ion-association complexes. As a result, not only the spectra of absorption and fluorescence are changed, but also the resonance Rayleigh scattering (RRS) is enhanced greatly and the new RRS spectra are observed. The four TGCs products have similar spectral characteristics and their maximum RRS wavelengths are all located at 291 nm. The quantitative determination ranges and the detection limits of the four TGCs are 0.0065-1.0 μg mL−1 and 2.0 ng mL−1 for CZD, 0.0070-1.1 μg mL−1 and 2.2 ng mL−1 for CTRX, 0.0090-1.6 μg mL−1 and 2.7 ng mL−1 for CPZ, and 0.014-2.2 μg mL−1 and 4.2 ng mL−1 for CFTM, respectively. The optimum conditions of the reactions and the effects of foreign substances are investigated, and the composition of ion-association complexes is discussed also. Based on the ion-association reaction, a highly sensitive, simple and rapid method has been proposed to the determination of TGCs.  相似文献   

14.
Enriching the surface density of immobilized capture antibodies enhances the detection signal of antibody sandwich microarrays. In this study, we improved the detection sensitivity of our previously developed P-Si (porous silicon) antibody microarray by optimizing concentrations of the capturing antibody. We investigated immunoassays using a P-Si microarray at three different capture antibody (PSA – prostate specific antigen) concentrations, analyzing the influence of the antibody density on the assay detection sensitivity. The LOD (limit of detection) for PSA was 2.5 ng mL−1, 80 pg mL−1, and 800 fg mL−1 when arraying the PSA antibody, H117 at the concentration 15 μg mL−1, 35 μg mL−1, and 154 μg mL−1, respectively. We further investigated PSA spiked into human female serum in the range of 800 fg mL−1 to 500 ng mL−1. The microarray showed a LOD of 800 fg mL−1 and a dynamic range of 800 fg mL−1 to 80 ng mL−1 in serum spiked samples.  相似文献   

15.
A novel solid-phase microextraction (SPME) fiber coated with multiwalled carbon nanotubes (MWCNTs)/Nafion was developed and applied for the extraction of polar aromatic compounds (PACs) in natural water samples. The characteristics and the application of this fiber were investigated. Electron microscope photographs indicated that the MWCNTs/Nafion coating with average thickness of 12.5 μm was homogeneous and porous. The MWCNTs/Nafion coated fiber exhibited higher extraction efficiency towards polar aromatic compounds compared to an 85 μm commercial PA fiber. SPME experimental conditions, such as fiber coating, extraction time, stirring rate, desorption temperature and desorption time, were optimized in order to improve the extraction efficiency. The calibration curves were linear from 0.01 to 10 μg mL−1 for five PACs studied except p-nitroaniline (from 0.005 to 10 μg mL−1) and m-cresol (from 0.001 to 10 μg mL−1), and detection limits were within the range of 0.03–0.57 ng mL−1. Single fiber and fiber-to-fiber reproducibility were less than 7.5 (n = 7) and 10.0% (n = 5), respectively. The recovery of the PACs spiked in natural water samples at 1 μg mL−1 ranged from 83.3 to 106.0%.  相似文献   

16.
Ayman A. Gouda 《Talanta》2009,80(1):151-157
Studies were carried out, for the first time, to investigate the charge-transfer reactions of ganciclovir as n-electron donor with the σ-acceptor iodine and various π-acceptors: 7,7,8,8-tetracyanoquinodimethane; tetracyanoethylene; 2,3-dichloro-5,6-dicyano-1,4-benzoquinone; p-chloranilic acid; 2,3,5,6-tetrabromo-1,4-benzoquinone; 2,3,5,6-tetrachloro-1,4-benzoquinone and 2,4,7-trinitro-9-fluorenone. The formation of the colored charge-transfer complexes was utilized in the development of simple, rapid and accurate spectrophotometric methods for the analysis of ganciclovir in pure form as well as in its pharmaceutical formulation (capsules). Different variables affecting the reactions were studied and optimized. Under the optimum reaction conditions, linear relationships with good correlation coefficients (0.9993-0.9998) were found between the absorbance and the concentration of ganciclovir in the range of 2.0-240 μg mL−1. For more accurate analysis, Ringbom optimum concentration range was found to be between 5.0 and 225 μg mL−1. The limits of detection ranged from 0.36 to 2.45 μg mL−1 and the limits of quantification ranged from 1.20 to 8.17 μg mL−1. A Job's plot of the absorbance versus the molar ratio of ganciclovir to each of acceptors under consideration indicated (1:1) ratio. The proposed methods were applied successfully for simultaneous determination of ganciclovir in capsules with good accuracy and precision and without interferences from common additives. The recovery percentages ranged from 99.45 ± 0.73% to 100.35 ± 1.40%. The results were compared favourably with the reported method.  相似文献   

17.
New, simple, rapid and precise HPLC-PDA method has been developed and validated for quantification of biomarker myrsinoic acid B in stem bark extracts of Rapanea ferruginea Mez. The method employs a Phenomenex C18 column (250 mm × 4.6 mm I.D., 5 μm) with acetonitrile:methanol:water (pH 2.6 with phosphoric acid) at 48:30:22 as mobile phase, at a flow rate of 0.7 mL min−1 and photo diode array (PDA) detection at 270 nm. The validation data show that the method is specific, accurate, precise and robust. The method was linear, over a range of 5-100.0 μg mL−1, with a limit of detection of 0.369 μg mL−1 and limit of quantification of 1.233 μg mL−1. The method has also shown consistent recoveries (average of 101.3% and 0.12% RSD) of the biomarker, with low intra and inter-day relative standard deviation (1.26% and 1.62%, respectively). The evaluated hydroethanolic extract and dry extract presented MAB values of 63.53 and 36.07 mg g−1, respectively.  相似文献   

18.
A simple, precise, accurate and validated, acetonitrile-free, reverse phase high performance liquid chromatography (HPLC) method is developed for the determination of melamine in dry and liquid infant formula. The separation is performed on a Kromasil C18 column (150 mm × 3.2 mm I.D., 5 μm particle size) at room temperature. The mobile phase (0.1% TFA/methanol 90:10) is pumped at a flow rate of 0.3 mL min−1 with detection at 240 nm. Melamine elutes at 3.7 min. A linear response (r > 0.999) is observed for samples ranging from 1.0 to 80 μg mL−1. The method provides recoveries of 97.2-101.2% in the concentration range of 5-40 μg mL−1, intra- and inter-day variation in <1.0% R.S.D. The limit of detection (LOD) and limit of quantification (LOQ) values are 0.1 μg mL−1 and 0.2 μg mL−1, respectively.  相似文献   

19.
A simple chemiluminometric method using flow injection has been developed for the determination of paracetamol (acetaminophen), based on the chemiluminescence produced by the reduction of tris(2,2′-bipyridyl)ruthenium(III). The latter is obtained by oxidation of tris(2,2′-bipyridyl)ruthenium(II) by potassium permanganate in dilute sulphuric acid in the presence of paracetamol. A standard or sample solution was injected into the ruthenium(II) stream (flow rate 1.5 ml min−1) which was then merged with potassium permanganate in dilute sulphuric acid stream (flow rate 0.5 ml min−1). The chemiluminescence intensity is enhanced by the presence of manganese(II) ions. Under the optimum conditions, a linear calibration graph was obtained over the range of 0.3-50.0 μg ml−1 and the detection limit was 0.2 μg ml−1 (s/n = 3). The relative standard deviation of the proposed method calculated from 20 replicate injections of 5.0 μg ml−1 paracetamol was 1.1%. The sample throughput was 90 h−1. The method was successfully applied to the determination of paracetamol in commercial pharmaceutical formulations.  相似文献   

20.
A sensitive and selective high-performance liquid chromatographic method has been developed and validated for the determination of nateglinide in human plasma. Nateglinide and the internal standard, undecylenic acid, were extracted from plasma by liquid-liquid extraction using a mixture of ethyl acetate-diethyl ether, 50:50 (v/v). Pre-column derivatization reaction was performed using a coumarin-type fluorescent reagent, N-(7-methoxy-4-methyl-2-oxo-2H-6-chromenyl)-2-bromoacetamide. The derivatization proceeded in acetone in the presence of potassium carbonate and catalyzed by 18-crown-6 ether. The fluorescent derivatives were separated under isocratic conditions on a Hypersil BDS-C8 analytical column (250.0 mm × 2.1 mm i.d., particle size 5 μm) with a mobile phase that consisted of 65% acetonitrile in water and pumped at a flow rate of 0.50 mL min−1. The excitation and emission wavelengths were set at 345 and 435 nm, respectively. The assay was linear over a concentration range of 0.05-16.00 μg mL−1 for nateglinide with a limit of quantitation of 0.05 μg mL−1. Quality control samples (0.05, 4.50 and 16.00 μg mL−1) in five replicates from five different runs of analysis demonstrated intra-assay precision (%coefficient of variation <6.8%), inter-assay precision (%coefficient of variation <1.6%) and an overall accuracy (%relative error) less than −3.4%. The method can be used to quantify nateglinide in human plasma covering a variety of pharmacokinetic or bioequivalence studies.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号