共查询到20条相似文献,搜索用时 15 毫秒
1.
A new polyvinyl chloride (PVC) membrane electrode that is highly selective to Hg(II) ions was prepared by using bis[5-((4-nitrophenyl)azo salicylaldehyde)] (BNAS) as a suitable neutral carrier. The sensor exhibits a Nernstian response for mercury ions over a wide concentration range (5.0×10−2-7.0×10−7 M) with a slope of 30±1 mV per decade. It has a response time of <10 s and can be used for at least 3 months without any measurable divergence in potential. The electrode can be used in the pH range from 1.0 to 3.5. The proposed sensor shows fairly good discriminating ability towards Hg2+ ion in comparison with some hard and soft metals. The electrode was used in the direct determination of Hg2+ in aqueous solution and as an indicator electrode in potentiometric titration of mercury ions. 相似文献
2.
Iran Sheikhshoaie Tayebeh Shamspur S. Yousef Ebrahimipur 《Arabian Journal of Chemistry》2012,5(2):201-205
Manganese(II) complex of (E)-2-(hydroxyl-5-methoxybenzylideneamino) phenol was synthesized and used as a suitable Mn(II) – selective membrane in PVC matrix. The plasticized membrane sensor exhibits a nersian response for Mn(II) ions over a wide concentration range of 6 × 10?6–2 × 10?2 M with slope of 29 ± 1 mV per decade. It has a response time of <11 s and can be used for 2 months without any measurable divergence in potential. The response of the proposed sensor is independent of pH between 4 and 9.5. The proposed sensor shows a fairly good discriminating ability towards Mn(II) in comparison with some hard and soft metals. The electrode was used in the determination of Mn(II) in aqueous solutions and as an indicator electrode in potentiometer titration of manganese ions against EDTA. 相似文献
3.
A PVC membrane electrode for Ni2+ ions based on a recently synthesized mercapto compound, as an ionophore was prepared. The electrode exhibits a Nernstian slope of 28-30 mV per concentration decade at wide concentration range of (1.0×10−2-1.0×10−7 M). It has a fast response time of <15 s and can be used for at least 4 weeks. The potentiometric response is independent of the pH of the test solution in the pH range 5-8.5. The proposed electrode revealed good selectivities over a wide variety of other cations including alkali, alkaline earth, transition and heavy metal ions. It was successfully applied to the direct determination and potentiometric titration of nickel ion with EDTA. 相似文献
4.
N,N′,N″,N′′′-1,5,8,12-tetraazadodecane-bis(salicylaldiminato)(H2L) has been used as ionophore for preparing Mn2+ selective sensor. Membranes of different composition with regard to ratio of H2L:PVC:NPOE:NaTPB have been prepared and investigated. The best performance was obtained with the membrane of composition 10:150:150:10 (H2L:PVC:NPOE:NaTPB) (w/w; mg). This membrane generated linear potential response in the concentration range of 5.0 × 10−6 to 1.0 × 10−1 M with a Nernstian slope of 30.0 mV/decade of activity and fast response time (10 s). Hydrogen ion does not effect to the performance of sensor in the pH range 3.0-6.5. The sensor was found to be sufficient selective for Mn2+ over a number of alkali, alkaline and heavy metal ions and could therefore be used for the determination of manganese in various samples by direct potentiometry. 相似文献
5.
Bis(2-hydroxyacetophenone)butane-2,3-dihydrazone (BHAB) was used as new N-N Schiffs base which plays the role of an excellent ion carrier in the construction of a Cu(II) membrane sensor. The best performance was obtained with a membrane composition of 30% poly(vinyl chloride), 55% o-nitrophenyloctyl ether (NPOE), 7% BHAB and 8% oleic acid (OA). This sensor shows very good selectivity and sensitivity towards copper ion over a wide variety of cations, including alkali, alkaline earth, transition and heavy metal ions. The effect of membrane composition and pH and influence of additive anionic on the response properties of electrode were investigated. The electrode exhibits a Nernstian behavior (with slope of 29.6 mV per decade) over a very wide concentration range (5.0 × 10−8 to 1.0 × 10−2 mol L−1) with a detection limit of 3.0 × 10−8 mol L−1 (2.56 ng mL−1). It shows relatively fast response time, in whole concentration range (<15 s), and can be used for at least 12 weeks in the pH range of 2.8-5.8. The proposed sensor was successfully used to determination of copper in different water samples and as indicator electrode in potentiometric titration of copper ion with EDTA. 相似文献
6.
A novel bromide ion-selective PVC membrane sensor based on 2,3,10,11-tetraphenyl-1,4,9,12-tetraazacyclohexadeca-1,3,9,11-tetraene zinc(II)complex (I) as carrier has been developed. The electrode exhibited wide working concentration range 2.2 × 10−6 to 1.0 × 10−1 M and a limit of detection as 1.4 × 10−6 M with a Nernstian slope of 59.2 ± 0.5 mV per decade. The response time of electrode was 20 s over entire concentration range. The electrode possesses the advantages of low resistance, fast response and good selectivities for bromide over a variety of other anions and could be used in a pH range of 3.5–9.5. It was successfully used as an indicator electrode in the potentiometric titration of bromide ions with silver ion and also in the determination of bromide in real samples. 相似文献
7.
Vinod Kumar Gupta Ashok Kumar Singh Sameena Mehtab Barkha Gupta 《Analytica chimica acta》2006,566(1):5-10
A new PVC membrane electrode for Co2+ based on N,N′-bis(salicylidene)-3,4-diaminotoluene, an excellent neutral carrier, has been fabricated using sodium tetraphenylborate (NaTPB) as an anionic excluder and dioctylphthalte (DOP) as a solvent mediator. The electrode exhibits a linear potential response in the concentration range of 7.9 × 10−8 to 1.0 × 10−1 M with a slope of 30 ± 0.2 mV per decade. The detection limit of the proposed sensor is 5.0 × 10−8 M and it can be used over a period of 5 months. The proposed sensor revealed good selectivity over a wide variety of other cations including alkali, alkaline earth, heavy and transition metals and could be used in the pH range of 2.0-9.0. This electrode was successfully applied for the determination of Co2+in real samples and as an indicator electrode in potentiometric titration of cobalt ions. 相似文献
8.
Nahid Tavakkoli Zahra Khojasteh Hashem Sharghi Mojtaba Shamsipur 《Analytica chimica acta》1998,360(1-3):203-208
Four different 9,10-anthraquinone derivatives were studied to characterize their abilities as lead ion carrier in PVC membrane electrodes. The electrode based on 1,8-dihydroxy-2,7-bis(prop-2′-enyl)-9,10-anthraquinone exhibits a Nernstian response for Pb2+ ions over a wide concentration range (2.0×10−3–2.0×10−6 M). The response time of the sensor is 30 s and the membrane can be used for more than four months without observing any deviation. The electrode revealed comparatively good selectivities with respect to alkali, alkaline earth and some transition and heavy metal ions. It was used as an indicator electrode in potentiometric titration of sulfate ions with a lead ion solution. 相似文献
9.
A novel salicylate-selective electrode based on a Sn(IV) complex of salicylal-imino acid Schiff base
A novel poly(vinyl chloride) membrane electrode with high selectivity toward salicylate (Sal–), based on the use of the salicylal-imino acid Schiff base dibenyl complex of Sn(IV) [Sn(IV)-SIADBen] as ionophore is described. The influence of lipophilic charged additives on the performance of the electrode was studied. The results suggested that Sn(IV)-SIADBen according to a positively-charged carrier mechanism. The influence of several other variables was investigated in order to optimize the potentiometric response and selectivity of the electrode. The electrode based on Sn(IV)-SIADBen, with 30.44 wt% PVC, 64.55 wt% plasticizer [dioctyl phthalate (DOP)], 3.81 wt% ionophore, and 1.2 wt% anionic additive exhibited a linear response for the Sal– ion over the concentration range 1.0×10–1 to 2.5×10–6 mol l–1, and displayed an anti-Hofmeister selectivity sequence as follows: salicylate perchlorate > thiocyanate > benzoate > iodide > nitrate > chloride > nitrite acetate > citrate > sulfate. UV-Visible absorption spectra were used to examine the specific interaction of salicylate with the ionophore. The electrode was applied to clinical medical analysis, and the results obtained were consistent with those obtained by conventional methods. 相似文献
10.
Two new PVC membrane electrodes that are highly selective to Ag(I) ions were prepared using (L1) calyx[4]arene (L2) as two suitable neutral carriers. The silver(I) ion selective electrodes exhibit a good response for silver ion over a wide
concentration range of 1.0 × 10−1 to 4.2 × 10−6 M (L1) and 1.0 × 10−1 to 6.5 × 10−6 M (L2) with a Nernstian slope of 60 mV per decade (L1) and 58 mV per decade (L2) at 25°C, and was found to be very selective, precise, and usable within the pH range 4.0–8.0. They have a response time
of <15 s and can be used for at least 3 months without any measurable divergence in potential. The proposed sensors show a
fairly good discriminating ability towards Ag+ ion in comparison to some hard and soft metal ions. The electrodes were used as indicator electrodes in the potentiometric
titration of silver ion and in the determination of Ag+ in photographic emulsion and radiographic and photographic films.
Published in Russian in Elektrokhimiya, 2009, Vol. 45, No. 7, pp. 862–868.
The article is published in the original. 相似文献
11.
A new poly(vinyl chloride) (PVC) membrane ion‐selective electrode based on bis‐salicyladehyde‐diaminjodipropylamine (BSDDA) as an ion carrier was successfully applied to the detection of Hg2+ ions. This electrode displayed good selectivity toward Hg2+ in comparison with other metal ions and exhibited a Nernstian slope of 30.5 ± 0.4 mV per decade of Hg2+ over a concentration range of 9.5 × 10?7 to 6.4 × 10?2 M of Hg2+ in the pH range 1.5 to 3.5. The detection limit was 7.0 ± 0.2 × 10?7 M and response time was about 10 s to 25 s. The electrode can be used at least 2 months without apparent divergence in potential. In addition, the effects of experimental parameters such as membrane composition, nature and amounts of plasticizer and additive were investigated. The proposed electrode could be used as an indicator electrode in the detection of Hg2+ in samples. 相似文献
12.
Mojtaba Shamsipur Ahmad Soleymanpour Morteza Akhond Hashem Sharghi Mohammad Ali Naseri 《Analytica chimica acta》2001,450(1-2):37-44
A new modified carbon paste electrode (CPE) based on a recently synthesized Schiff base complex of Fe(III) as a suitable carrier for I− ion is described. The electrode exhibits a super Nernstian slope of 71.0±0.3 mV per decade for I− ion over a wide concentration range from 1.0×10−6 to 5.0×10−1 M, with a low detection limit of 6.5×10−7 M. It has a relatively fast response time, a satisfactory reproducibility and relatively long life time. The proposed sensor shows a fairly good selectivity toward I− ion in comparison to other common anions. The potentiometric response is independent of the pH of the test solution in the pH range 3.5–10.0. Spectrophotometric studies confirmed the redox-type response mechanism of the electrode toward iodide ion. The proposed electrode was used as an indicator electrode in potentiometric titration of iodide ion. 相似文献
13.
Ashok Kumar Singh Ravindra Pratap Singh Sameena Mehtab 《Journal of inclusion phenomena and macrocyclic chemistry》2008,60(1-2):9-15
A new polystyrene based membrane electrode of methyl substituted 6,7:13,14-dibenzo-2,4,9,11-tetraphenyl-1,5,8,12-tetraazacyclotetradeca-1,4,6,8,11,13-hexaene
(I) with sodium tetraphenylborate (NaTPB) and dibutyl phthalate (DBP) as anion excluder and plasticizing agent was prepared and
investigated as Hg (II)-selective electrode. The electrode exhibits a Nernstian response for Hg (II) ions over a wide concentration
range of 1.0 × 10−1–8.9 × 10−6 M with a slope of 30 ± 1 mV per decade concentration. It has a response time of 10 s and can be used for at least 4 months
without any divergence in potentials. The membrane works satisfactorily in a partially non-aqueous medium up to a maximum
30% (v/v) content of methanol and ethanol. The proposed sensor revealed good selectivity over a wide variety of other cations
including alkali, alkaline earth, heavy and transition metal ions and could be used in a pH range of 2.5–5.0. Normal interferents
like Ag+, Cd2+ and Pb2+ low interfere in the working of the electrode. The electrode was successfully used in the direct determination of Hg2+ in aqueous solution. 相似文献
14.
The suitability of a xanthone derivative, 1-hydroxy-3-methyl-9H-xanthen-9-one (HMX) as a neutral ionophore for the preparation of a polyvinylchloride (PVC) membrane electrode for aluminum(III) ions was investigated. The prepared electrode exhibits a Nernstian response for Al3+ ions over a wide concentration range (1.0 × 10−6 to 1.6 × 10−1 M) with a limit of detection 6.0 × 10−7 M. It has a relatively fast response time and can be used for at least three months without any considerable divergence in potentials. The proposed membrane electrode revealed very good selectivity for Al3+ ions over a wide variety of other cations and could be used at a working pH range of 3.0-8.5. It was used as an indicator electrode in potentiometric titration of aluminum ions with EDTA and in the determination of Al3+ in different real samples. 相似文献
15.
Shamsipur M Javanbakht M Mousavi MF Ganjali MR Lippolis V Garau A Tei L 《Talanta》2001,55(6):507-1054
Three different mixed aza-thioether crowns containing a 1,10-phenanthroline sub-unit were investigated to characterize their abilities as copper(II) ion carriers in PVC-membrane electrodes. The electrode based on L1 exhibited a Nernstian response for Cu2+ ions over a wide concentration range (2×10−1 to 1×10−5 M) with a limit of detection of 8.0×10−6 M (0.5 p.p.m.). The response time of sensor is 15 s, and the membrane can be used for more than 3 months without observing any deviation. The electrode revealed comparatively good selectivities with respect to many alkali, alkaline earth, transition and heavy metal ions, and could be used in a pH range of 2.5–5.5. It was applied to the direct determination and potentiometric titration of the copper(II) ion. 相似文献
16.
A new highly Tl(I)-selective PVC membrane electrode based on tetrathia macrocycle 6,7: 14,15-dibenzo-5,8,13,16-tetraoxo-1,4,9,12-tetrathiacyclohexadecane [Bz2O4(16)aneS4] (I) as membrane carrier, o-nitrophenyloctyl ether (o-NPOE) as solvent mediator and potassium tetrakis(p-chlorophenyl)borate (KTpClPB) as lipophilic additive has been developed. The best performance was given by the membrane of macrocycle (I) with composition 3:120:1.5:50 (I:o-NPOE:KTpClPB:PVC). This electrode exhibits a Nernstian response to Tl(I) ions in the concentration range 1.0 × 10−1-2.23 × 10−6 M with a slope of 58.2 mV/decade of concentration and a detection limit of 1.58 × 10−6 M. The response time of the sensor is 12 s and can be used over a period of 4 months with good reproducibility. The proposed electrode revealed good selectivity over a wide variety of other cations including alkali, alkaline earth, heavy and transition metals. The electrode works well over a pH range of 3.2-11.5 and in partially non-aqueous medium with up to 30% organic content. The sensor was also used as an indicator electrode in potentiometric titration of Tl(I) ions with KI solution. 相似文献
17.
Mohammad Reza Ganjali Tahereh Poursaberi Leila Haji-agha Babaei Shohre Rouhani Mohammad Yousefi Maryam Kargar-Razi Abolghasem Moghimi Hossein Aghabozorg Mojtaba Shamsipur 《Analytica chimica acta》2001,440(2):5376-87
A PVC membrane electrode based on bis-2-thiophenal propanediamine (TPDA) coated directly on graphite is described. The electrode exhibits a Nernstian response for Cu2+ over a very wide concentration range (1.0×10−1 to 6.0×10−8 M) with a detection limit of 3.0×10−8 M (2.56 ng ml−1). It has a fast response time and can be used for at least 2 months without any major deviation. The proposed sensor revealed very good selectivities for Cu2+ over a wide variety of other metal ions and could be used in the pH range of 3.0–7.0. It was successfully used for direct determination of copper in black tea and as an indicator electrode in potentiometric titration of copper ion. 相似文献
18.
Tahereh PoursaberiMorteza Hosseini Massoud TaghizadehHooshang Pirelahi Mojtaba ShamsipurMohammad Reza Ganjali 《Microchemical Journal》2002,72(1):77-83
A highly selective electrode for iodide ion based on a thiopyrilium derivative as an excellent ionophore is described. At pH 5.5-8.0, the electrode responds to iodide ion in a linear range from 1.0×10−1 to 8.0×10−7 M with a slope of 60.2 mV per decade, and a detection limit of 2.0×10−7 M. Selectivity coefficients determined with the match potential method (MPM) indicate that the interference from inorganic and organic anions is very small. The proposed sensor shows a fast response time of approximately 15 s. It was applied as an indicator electrode in titration of iodide with Ag+. 相似文献
19.
《Journal of Saudi Chemical Society》2014,18(5):555-560
A new PVC membrane based strontium(II) ion-selective electrode has been constructed using acetophenone semicarbazone as a neutral carrier. The sensor exhibits a Nerstian response for strontium(II) ion over a wide concentration range 1.0 × 10−2–1.0 × 10−7 M with the slope of 29.4 mV/per decade. The limit of detection was 2.7 × 10−8 M. It was relatively fast response time (<10 s for concentration ⩾1.0 × 10−3 and <15 s for concentration of ⩾1.0 × 10−6 M) and can be used for 8 months without any considerable divergence in potentials. The proposed sensor revealed relatively good selectivity and high sensitivity for strontium(II) over a mono, di, trivalent cation and can be used in a pH range of 2.5–10.5. It was also successfully used as an indicator electrode in potentiometer titration and in the analysis of concentration in various real samples. 相似文献
20.
A PVC membrane electrode for lead ions based on 5,5′-dithiobis-(2-nitrobenzoic acid) as membrane carrier was prepared. The electrode exhibits a Nernstian response for Pb2+ over a wide concentration range (1.0×10−2–4.0×10−6 M). It has a relatively fast response time and can be used for at least 3 months without any divergence in potentials. The proposed electrode revealed good selectivities for Pb2+ over a wide variety of other metal ions and could be used in a pH range of 2.0–7.0. It was used as an indicator electrode in potentiometric titration of lead ions and in direct determination of lead in water samples. 相似文献