首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The voltammetric behaviour of three 5-nitroimidazoles,metronidazole,tinidazole and ornidazole,was investigated,and a method was developed for the simultaneous determination of these compounds,based on their reduction at a hanging mercury drop electrode(HMDE) in pH 8.95 buffer with differential pulse voltammetric(DPV) approach.Well defined voltammetric waves with peak potentials of -692,-640 and -652 mV were observed for these compounds,respectively.It is difficult to determine them individually from their mixtures without preseparation,for their voltammetric peaks overlapped seriously,so the chemometrics were used to resolve the overlapped voltammogram and quantify the mixtures.The proposed method was successfully applied to the determination of three 5-nitroimidazoles in milk and honey samples.  相似文献   

2.
研究了呋喃唑酮在玻碳电极上的伏安行为。在 1mol LHCl底液中 ,用微分脉冲阴极溶出伏安法得到一灵敏的呋喃唑酮还原峰 ,峰电位为 0 .0 38V(vs.Ag AgCl)。峰电流与呋喃唑酮浓度在 8× 1 0 -6~ 1× 1 0 -4 mol L范围内呈线性关系 (r=0 .9984) ,检出限为 8× 1 0 -8mol L。该法已用于片剂与合成血清样品中呋喃唑酮含量的测定  相似文献   

3.
微分脉冲阴极溶出伏安法测定阿米卡星   总被引:1,自引:1,他引:0  
硫酸阿米卡星(Am ikacin sulfate)是一种氨基糖苷酸类抗生素,化学名为O-3氨基-3-脱氧-а-D-蒲吡喃糖基-(1-6)-O-[6-氨基-6-脱氧-а-D-蒲吡喃糖基-(1-4)]-N-(4-氨基-2-羟基-1-氧丁基)-2-脱氧?D-链霉胺硫酸盐。目前报道的测定方法主要有高效液相法[1]、镍毛细管电泳法[2]。本文研究了阿米卡星在玻碳电极上的电化学行为。微分脉冲溶出伏安法是一种灵敏度很高的痕量分析方法,本文利用该方法对阿米卡星进行了测定,发现阿米卡星在pH=2的盐酸底液中,产生一灵敏的还原峰,可用于定量测定。平行测定了7次,RSD为2·05%,该方法可用于注射液及血清中…  相似文献   

4.
建立中成药中胆红素定量测定的微分脉冲伏安法。在多种介质中研究胆红素在玻碳电极上的电化学行为 ,全面优化条件后 ,采用标准加入法对中成药中胆红素进行测定 ,并通过与药典中标准方法对照和干扰实验及回收率实验对本方法进行评价。在 0 .2mol·L-1HAc NaAc 5 0 %EtOH和 1 1 5mol·L-1KH2 PO4 Na2 HPO4 溶液中 ,峰电流与胆红素浓度分别在 6.2 5× 1 0 -7~ 1 .0 0× 1 0 -5mol·L-1(r=0 .9976)和 5 .0 0× 1 0 -8~ 3.0 0× 1 0 -6mol·L-1(r=0 .9939)范围内呈良好的线性关系 ,检测下限分别为 5 .0× 1 0 -8mol·L-1和 5 .0× 1 0 -9mol·L-1。众生丸和牛黄解毒片中胆红素的质量分数分别为 0 .0 86%和 0 .1 0 9% ,RSD分别为 3 4%和 3.0 % ,回收率为 96.6%~ 1 0 4 .1 % ,其结果与药典中标准方法测定结果基本一致。  相似文献   

5.
The electrochemical solid phase micro-extraction of salicylic acid (SA) at graphite-epoxy-composed solid electrode surface was studied by cyclic voltammetry. SA was oxidized electrochemically in pH 12.0 aqueous solution at 0.70 V (vs. saturated calomel electrode) for 7 s. The oxidized product shows two surface-controlled reversible redox couples with two proton transferred in the pH range of 1.0∼6.0 and one proton transferred in the pH range of 10.0∼13.0 and is extracted on the electrode surface with a kinetic Boltzman function of i p = 3.473–4.499/[1 + e(t − 7.332)/6.123] (χ 2 = 0.00285 μA). The anodic peak current of the extracted specie in differential pulse voltammograms is proportional to the concentration of SA with regression equation of i p = −5.913 + 0.4843 c (R = 0.995, SD = 1.6 μA) in the range of 5.00∼200 μM. The detection limit is 5.00 μM with RSD of 1.59% at 60 μM. The method is sensitive and convenient and was applied to the detection of SA in mouse blood samples with satisfactory results.  相似文献   

6.
Bromadiolone, a commercially used anticoagulant rodenticide, was determined in tissues of various animals by differential pulse voltammetry with a carbon-paste electrode. Under the most suitable experimental conditions (step potential of 25?mV?s?1 and 0.2?mol?L?1 acetate buffer, pH 4.2), the limit of detection was 0.5?ng?mL?1. The electroanalytical method was consequently used to investigate the bromadiolone transport within the food chain. Pheasants were exposed to bromadiolone and then used as feed for a fox. The average levels were 528 and 198?ng of bromadiolone per gram of fresh weight of liver of pheasant and fox, respectively. Due to the surprisingly lower content of bromadiolone in the latter, a basic biochemical analysis, particularly blood coagulation, was performed. Among the parameters studied (thrombin time, prothrombin time, activated partial thromboplastin time, and fibrinogen), there was prolongation of the prothrombin time and activated partial thromboplastin time.  相似文献   

7.
A new method for the determination of nitrobenzene (NB) by differential pulse voltammetry (DPV) based on an adsorptive stripping technique was developed. Cyclic voltammetry (CV) was used in a comparative investigation into the electrochemical reduction of NB at a glassy carbon electrode (GCE). With this electrode, the sharp peak of NB appeared at −0.71 V (vs. Ag/AgCl). The experimental parameters were optimized. Studies on the effect of pH on the peak height and peak potential were carried out over the pH range ca. 9.0–11.5 with sodium carbonate/sodium hydrogen carbonate buffer solution. A solution of pH 9.9 was chosen as analytical medium. Cathodic peak currents were found to be linearly related to the concentration of NB over the range ca. 12.3–1.23 × 104 μg L−1 with relative standard deviations of ca. 3.26–6.75%. The detection limit of NB in water was 5.42 μg L−1. The interference of organic and inorganic species on the voltammetric response was also studied. The proposed method was applied to the determination of NB in wastewater samples with an average recovery of ca. 95.9–102.4%.  相似文献   

8.
Lutetium has been determined by differential pulse anodic stripping voltammetry in an acidic solution containing Zn-EDTA. Lutetium (III) ions liberated zinc (II), which was preconcentrated on a hanging mercury drop electrode and stripped anodically, resulting in peak current linearly dependent on lutetium (III) concentration. Less than 0.4 ng mL−1 lutetium could be detected after a 2 min deposition.   相似文献   

9.
The use of selective pre-concentration and differential pulse anodic stripping voltammetry (DPASV) using a carbon paste electrode modified (CPEM) with spinel-type manganese oxide has been proposed for the determination of lithium ions content in natural waters. The new procedure is based on the effective pre-concentration of lithium ions on the electrode surface containing spinel-type Mn(IV) oxide with the reduction of Mn(IV) to Mn(III) and consequently the lithium ions intercalation (insertion) into the spinel structure. The best DPASV response was reached for an electrode composition of 25% (m/m) spinel-type MnO2 in the paste, 0.1 mol l−1 tris(hydroxymethyl)aminomethane (TRIS) buffer solution of pH 8.3, scan rate of 5 mV s−1, accumulation potential of 0.3 V versus saturated calomel reference electrode (SCE), pre-concentration time of 30 s and potential pulse amplitude of 50 mV. In these experimental conditions, the proposed methodology responds to lithium ions in the concentration range of 2.8×10−6 to 2.0×10−3 mol l−1 with a detection limit of 5.6×10−7 mol l−1. The determination of the lithium ions content in different samples of natural waters samples using the proposed methodology and atomic absorption spectrophotometry are in agreement at the 95% confidence level and within an acceptable range of error.  相似文献   

10.
A reliable method for simultaneous determination of three antibiotic drugs(levofloxacin,gatifloxacin and lomefloxacin) by differential pulse stripping voltammetry(DPSV) in Britton-Robinson buffer(pH 7.96) was presented.The method is based on adsorptive accumulation of the antibacterial drugs on a hanging mercury dropping electrode(HMDE),followed by the reduction of the adsorptive species by the technique of DPSV.Optimal conditions,the deposition time of 80 s,the deposition potential of—1250 mV,and the scan rate of 25 mV/s,were obtained.The linear concentration ranges of 0.010-0.080μg/mL were obtained for all these three antibiotic drugs,while the detection limits were 2.38,3.20 and 1.60ng/mL for levofloxacin,gatifloxacin and lomefloxacin,respectively.In this work,chemometrics methods,such as classical least squares(CLS),partial least squares(PLS), principle component regression(PCR) and radial basis function-artificial neural networks(RBF-ANN),were used to quantitatively resolve the overlapping signals.It was found that PCR gave the best results with total relative prediction error(RPE_T) of 7.71%.The proposed method was applied to determine these three drugs in several commercial food samples with spiked method and yielded satisfactory recoveries.  相似文献   

11.
Wei Wei Zhu  Nian Bing Li  Hong Qun Luo   《Talanta》2007,72(5):1733-1737
A stannum film electrode has been developed for the simultaneous determination of trace levels of chromium(III) and cadmium(II) by differential pulse anodic stripping voltammetry (DPASV). The stannum film electrode was generated in situ by depositing simultaneously the stannum film and the metals obtained by reduction of Cd(II) and Cr(III) at −1.4 V on a glassy carbon electrode. Then, the reduced products were oxidized by scanning the potential of the electrode from −1.4 to −0.4 V using DPASV. The electrode exhibited well-defined and separated stripping signals for both metals accompanied with a low background contribution. The possible mechanism of this design was proposed. Under the optimized working conditions, the detection limit was 2.0 and 1.1 μg l−1 for Cr(III) and Cd(II) at a deposition time of 3 min. Finally, the stannum film electrode was successfully applied to the determination of Cd(II) in tap water with satisfactory results.  相似文献   

12.
Inam R  Somer G 《Talanta》1998,46(6):1347-1355
The polarographic reduction of lead in the presence of selenite gives rise to an additional peak corresponding to the reduction of lead (Pb) on adsorbed selenium (Se) on mercury at −0.33 V. The selenium and lead content can be determined using this peak by the addition of a known amount of one of these ions first and then the second ion. The linear domain range of lead is 5.0×10−7–2.0×10−5 M and for selenium 5.0×10−7–1.0×10−5 M. Using this method 4.90×10−7 M Se(IV) and 1.47×10−6 M Pb(II) in a synthetic sample could be determined with a relative error of +2.0% and 1.8%, respectively (n=4). A recovery test after acid digestion for a synthetic sample was 97% for selenium and 96.5% for lead. The method was applied to 1 ml of digested blood, and 328±23 μg l−1 Se(IV) and 850±62 μg l−1 Pb(II) could be determined with a 90% (n=5) confidence interval.  相似文献   

13.
面粉中增白剂过氧化苯甲酰的示差脉冲伏安法测定   总被引:4,自引:2,他引:2  
研究了以二氯甲烷作为萃取剂,二氯甲烷-乙酸(1.5×10-2mol/L)为底液,四丁基高氯酸铵(0.01mol/L)为支持电解质,玻碳电极作为工作电极,采用示差脉冲伏安法测定过氧化苯甲酰。过氧化苯甲酰的阴极峰电位为-0.045V(vs.Ag/AgCl),峰电流与过氧化苯甲酰浓度在2.5×10-6~1.0×10-4mol/L范围内呈良好的线性关系,检出限为2.5×10-7mol/L。本法可直接用于小麦面粉中增白剂过氧化苯甲酰的测定。  相似文献   

14.
Simultaneous determination of sulfite and thiosulfate at sub-ppm levels in petroleum and its distillates was investigated using a convenient, accurate and sensitive procedure. This method involved preliminary extraction of the sample followed by detection via differential pulse polarography (DPP) at a dropping mercury electrode. In this procedure, an appropriate amount of sample was shaken with a recommended volume of 0.25% (w/w) sodium acetate solution. The mixture was filtered in two steps and was then ready for DPP. The method was free from interferences from hydrogen sulfide, elemental sulfur, organic sulfides, and thiophene. Various instrumental factors such as scan rate, pulse height, initial and final potential, and purge time were optimized. The 3σ detection limits were 410 and 125 ng g−1 for sulfite and thiosulfate, respectively. At 5 μg g−1 level in samples, the relative standard deviations (n=4) were 2.51 and 1.15% for sulfite and thiosulfate, respectively. The proposed method was applied to real samples containing input feeds, distillates and fuel oils from Abadan Petroleum Refinery in the south of Iran.  相似文献   

15.
Solid paraffin-based carbon paste electrodes modified with 2-aminothiazole organofunctionalized silica have been applied to the anodic stripping determination of copper ions in ethanol fuel samples without any sample treatment. The proposed method comprised four steps: (1) copper ions preconcentration at open circuit potential directly in the ethanol fuel sample; (2) exchange of the solution and immediate cathodic reduction of the absorbate at controlled potential; (3) differential pulse anodic stripping voltammetry; (4) electrochemical surface regeneration by applying a positive potential in acid media. Factors affecting the preconcentration, reduction and stripping steps were investigated and the optimum conditions were employed to develop the analytical procedure. Using a preconcentration time of 20 min and reduction time of 120 s at −0.3 V versus Ag/AgClsat a linear range from 7.5 × 10−8 to 2.5 × 10−6 mol L−1 with detection limit of 3.1 × 10−8 mol L−1 was obtained. Interference studies have shown a decrease in the interference effect according to the sequence: Ni > Zn > Cd > Pb > Fe. However, the interference effects of these ions have not forbidden the application of the proposed method. Recovery values between 98.8 and 102.3% were obtained for synthetic samples spiked with known amounts of Cu2+ and interfering metallic ions. The developed electrode was successfully applied to the determination of Cu2+ in commercial ethanol fuel samples. The results were compared to those obtained by flame atomic absorption spectroscopy by using the F-test and t-test. Neither F-value nor t-value have exceeded the critical values at 95% confidence level, confirming that there are no significant differences between the results obtained by both methods.  相似文献   

16.
Hu C  Wu K  Dai X  Hu S 《Talanta》2003,60(1):17-24
A simple and effective chemically modified carbon paste electrode (CMCPE) for the simultaneous determination of lead(II) and cadmium(II) was developed in this work. The electrode was prepared by the addition of diacetyldioxime into a carbon paste mixture. Pb2+ and Cd2+ were preconcentrated on the surface of the modified electrode by complexing with diacetyldioxime and reduced at a negative potential (−1.10 V). Then the reduced products were oxidized by differential pulse stripping. The fact that two stripping peaks appeared on the voltammograms at the potentials of −0.65 V (Cd2+) and −0.91 V (Pb2+) demonstrates the possibility of simultaneous determination of Pb2+ and Cd2+. Under the optimized working conditions, calibration graphs were linear in the concentration ranges of 1.0×10−7-1.5×10−5 mol l−1 (Pb2+) and 2.5×10−7-2.5×10−5 mol l−1 (Cd2+), respectively. For 5 min preconcentration, detection limits of 1×10−8 mol l−1 (Pb2+) and 4×10−8 mol l−1 (Cd2+) were obtained at the signal noise ratio (SNR) of 3. To evaluate the reproducibility of the newly developed electrode, the measurements of 5×10−7 mol l−1 Pb2+ and Cd2+ were parallel carried out for six times at different electrodes and the relative standard deviations were 2.9% (Pb2+) and 3.2% (Cd2+), respectively. Interferences by some metals were investigated. Only Ni2+ and Hg2+ apparently affected the peak currents of Pb2+ and Cd2+. The diacetyldioxime modified carbon paste electrode was applied to the determination of Pb2+ and Cd2+ in water samples. The results indicate that this electrode is sensitive and effective for the simultaneous determination of Pb2+ and Cd2+.  相似文献   

17.
The chlorite ion is an unavoidable by-product of the disinfection of drinking water by means of chlorine dioxide. The maximum concentration values of chlorite accepted in many countries regulations range from 0.2 to 1.0 mg L–1. A simple, inexpensive and quickly set up voltammetric procedure for the on-site determination of chlorite in drinking water networks is described. This procedure is suitable for the whole range of applications in drinking water plants. A useful cell for on-field analysis has been developed. Surface morphology and behaviour of carbon-based working electrodes have been investigated by voltammetry and atomic force microscopy (AFM). Actual samples of different types of water networks have been analysed for chlorite concentration.  相似文献   

18.
采用线性循环溶出伏安法和差分脉冲溶出伏安法对磺胺嘧啶在电活化玻碳电极上的电化学行为进行了研究。玻碳电极在PBS溶液中(pH 7.0),用恒电位法在1.7 V阳极氧化400 s,在B-R缓冲溶液中,磺胺嘧啶在1.02V(vs.Ag/AgCl)处有一良好的氧化峰,在0.02~0.25 V/s范围内,其氧化峰电流与扫描速率呈良好线性关系,表明电极过程为受吸附控制的不可逆过程。差分脉冲溶出伏安法的氧化峰电流(Ipa)与磺胺嘧啶浓度1×10-6~1×10-4mol/L范围内呈良好的线性关系(r=0.9977),检出限为8.7×10-7mol/L(S/N=3)。方法已用于分析磺胺嘧啶片剂的分析。  相似文献   

19.
Procedures for the determination of indomethacin and acemethacin by differential pulse adsorptive stripping voltammetry with a mercury electrode have been described and optimised. The selection and optimization of the experimental parameters was done using factorial and central composite designs. Indomethacin and acemethacin in urine were determined by this method with good results and without the need for tedious prior separation. For routine calibration and calculation of the ‘capacity to detect’, the robust regression method least median squares (LMS) has been proposed.  相似文献   

20.
A method comprising matrix exchange differential pulse stripping voltammetry (DPSV) at a gold film electrode has been proposed for the determination of small quantities of arsenic in pure gold. A wall-jet cell (WJC) and an on-line deoxygenation system were used to facilitate matrix exchange. The gold(I) cyanide complex was formed to avoid gold deposition on the electrode together with the arsenic. The pH of the sample solutions were adjusted to 3, as alkaline solutions gold(I) cyanide produced interference and the uncomplexed cyanide led to passivation of the gold film electrode. Matrix exchange electrolytes consisting of 4 mol l−1 hydrochloric acid or a combination of 2 mol l−1 sulphuric acid and 0.2 mol l−1 hydrochloric acid could be utilised. Arsenic concentrations as low as 0.1 mg l−1, could readily be detected in a gold matrix with a 60 s deposition time. While, cobalt and silver did not interfere with the arsenic determination, copper interfered even when present at similar concentrations to that of arsenic.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号