首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
The determination of uranium isotope ratios in individual particles is of great importance for nuclear safeguards. In the present study, an analytical technique by inductively coupled plasma mass spectrometry (ICP-MS) with a desolvation sample introduction system was applied to isotope ratio analysis of individual uranium particles. In ICP-MS analysis of individual uranium particles with diameters ranging from 0.6 to 4.2 μm in a standard reference material (NBL CRM U050), the use of the desolvation system for sample introduction improved the precision of 234U/238U and 236U/238U isotope ratios. The performance of ICP-MS with desolvation was compared with that of a conventionally used method, i.e., secondary ion mass spectrometry (SIMS). The analysis of test swipe samples taken at nuclear facilities implied that the performance of ICP-MS with desolvation was superior to that of SIMS in a viewpoint of accuracy, because the problems of agglomeration of uranium particles and molecular ion interferences by other elements could be avoided. These results indicated that ICP-MS with desolvation has an enough ability to become an effective tool for nuclear safeguards.  相似文献   

2.
The determination of isotope ratios in individual uranium particles is very important for nuclear safeguards. In this work, accelerator mass spectrometry (AMS), thermal ionization mass spectrometry (TIMS), and secondary ion mass spectrometry (SIMS) were applied to isotope ratio analysis of individual uranium particles and compared in terms of background, measurement accuracy, and efficiency. Several individual uranium particles (1–7 μm) from certified reference materials were used as samples. The results show that the average values of blank counting rate of 235U for AMS, FT-TIMS (FT: fission track), SEM-TIMS (SEM: scanning electron microscope), and SIMS were 7.3, 7.8, 2.7 and 2.2 cps, respectively. The relative error of 234U/235U and 234U/236U isotope ratios of the particles from U200 for AMS were within 10% and 20%, whereas the results of FT-TIMS and SIMS were within 5% and 10%, respectively. The relative error and external precision of 234U/238U and 235U/238U of the particles from U850 for the method of AMS, SEM-TIMS, and SIMS were within 10% and 5%, respectively. For 236U/238U, the average values of the relative error and external precision measured by AMS were within 5%, which measured by SEM-TIMS and SIMS were all within 10%. AMS has advantages in measuring 236U/238U. The measurement time of AMS and SEM-TIMS was shorter than that of FT-TIMS and longer than that of SIMS. It is considered that AMS and SEM-TIMS have a certain development prospect, and it is necessary to research deeply.  相似文献   

3.
The capability of inductively coupled plasma mass spectrometry (ICP-MS) for the determination of uranium isotope ratios in individual particles was determined. For this purpose, we developed an experimental procedure including single particle transfer with a manipulator, chemical dissolution and isotope ratio analysis, and applied to the analysis of individual uranium particles in certified reference materials (NBL CRM U050 and U350). As the result, the 235U/238U isotope ratio for the particle with the diameter between 0.5 and 3.9 μm was successfully determined with the deviation from the certified ratio within 1.8%. The relative standard deviation (R.S.D.) of the 235U/238U isotope ratio was within 4.2%. Although the analysis of 234U/238U and 236U/238U isotope ratios gave the results with inferior precision, the R.S.D. within 20% was possible for the measurement of the particle with the diameter more than 2.1 μm. The developed procedure was successfully applied to the analysis of a simulated environmental sample prepared from a mixture of indoor dust (NIST SRM 2583) and uranium particles (NBL CRM U050, U350 and U950a). From the results, the proposed procedure was found to be an alternative analytical tool for nuclear safeguards.  相似文献   

4.
The paper describes the application of laser ablation inductively coupled plasma mass spectrometry (LA-ICP-MS) for the isotopic analysis of individual uranium-oxide particles. The procedure developed is suitable for the accurate measurement of 234U, 235U, 236U and 238U isotopes in single actinide particles with lateral dimensions down to 10 μm. The 235U/238U isotope ratios can be obtained with a precision of a few percent relative standard deviation using a single collector ICP-MS instrument. The precision could be improved by the use of slow ablation and by taking several LA-ICP-MS replicate spectra on the same particle investigated. For the minor isotopes use of higher mass resolution (R = 4000) was necessary in some cases to avoid spectral interferences. The technique developed offers a rapid and accurate possibility for the isotopic composition determination of uranium-containing individual particles in environmental and safeguards samples.  相似文献   

5.
We employed femtosecond Laser Ablation Multicollector Inductively Coupled Mass Spectrometry for the determination of uranium isotope ratios in a series of standard reference material glasses (NIST 610, 612, 614, and 616). The uranium in this series of SRM glasses is a combination of isotopically natural uranium in the materials used to make the glass matrix and isotopically depleted uranium added to increase the uranium elemental concentration across the series. Results for NIST 610 are in excellent agreement with literature values. However, other than atom percent 235U, little information is available for the remaining glasses. We present atom percent and isotope ratios for 234U, 235U, 236U, and 238U for all four glasses. Our results show deviations from the certificate values for the atom percent 235U, indicating the need for further examination of the uranium isotopes in NIST 610-616.  相似文献   

6.
The determination of isotopes of uranium by alpha spectrometry in different environmental components (sediments, soil, water, plants and phosphogypsum) is presented and discussed in this paper. The alpha spectrometry is a very convenient and good technique for activity concentration of natural uranium isotopes (234U, 235U, 238U) in environmental samples and provides the most accurate determination of isotopic activity ratios between 234U and 238U. The analysis were provided information about possible sources of high concentrations of uranium in the examined sites determined by anthropogenic sources. The calculation of values 234U/238U in all analyzed samples was applied to identifying natural or anthropogenic uranium origin. Activity concentration of uranium isotopes in analyzed environmental samples shows that measurement of uranium levels is of great importance for environmental and safety assessment especially in contaminated areas (phosphogypsum waste heap).  相似文献   

7.
The 234U/238U isotope ratio has been widely used as a tracer for geochemical processes in underground aquifers. Quadrupole-based inductively coupled plasma mass spectrometry (ICP-MS) equipped with a high-efficiency nebulizer and a membrane desolvator was employed for the determination of 234U/238U isotope ratios in natural water samples. The instrumental limit of detection for 234U was at the low pg L−1 level with very low sample consumption. Measurement precision (234U/238U) was 3–5% for bottled mineral water with elevated uranium concentration (>1 μg L−1). For the analysis of groundwater samples from the Almonte-Marisma underground aquifer (Huelva, Spain), uranium was stripped from stainless steel planchets that had previously been used as radiometric counting sources for alpha-particle spectrometry. Potential spectral interferences from other metals introduced during the dissolution were investigated. Matrix-matched blank solutions were needed to subtract the background on 234U due to the formation of platinum argides, and to allow for mass bias correction and background correction. The Pt appears to be an impurity present in the stainless steel, either as a minor component by itself or after extraction from the anode and a subsequent uranium electrodeposition. The 234U/238U isotope ratio data were in very good agreement with those of alpha spectrometry, while precision was improved by a factor of up to 10 and counting time was reduced down to ~20 min (10 replicate measurements).  相似文献   

8.
Certified reference material (CRM) 115, Uranium (Depleted) Metal (Uranium Assay Standard), was analyzed using a TRITON Thermal Ionization Mass Spectrometer to characterize the uranium isotope-amount ratios. The certified 235U/238U “major” isotope-amount ratio of 0.0020337 (12) in CRM 115 was determined using the total evaporation (TE) and the modified total evaporation (MTE) analytical techniques. In the MTE method, the total evaporation process is interrupted on a regular basis to allow correction of background from peak tailing, internal calibration of the secondary electron multiplier detector versus the Faraday cups, peak-centering, and ion source re-focusing. For the “minor” 234U/238U and 236U/238U isotope-amount ratio measurements using MTE, precision and accuracy comparable to conventional analyses are achieved, without compromising the quality of the 235U/238U isotope-amount ratios. Characterized values of the 234U/238U and 236U/238U isotope-amount ratios in CRM 115 are 0.000007545 (10) and 0.000032213 (84), respectively. The 233U/238U isotope-amount ratio in CRM 115 is estimated to be <5 × 10?9. The homogeneity of the CRM 115 materials is established through the absence of any statistically significant unit-to-unit variation in the uranium isotope-amount ratios. The measurements leading to the certification of uranium isotope-amount ratios are discussed.  相似文献   

9.
A set of six samples, collected worldwide from various uranium ore mining facilities, was analysed for uranium isotopic composition by high accuracy isotope mass spectrometry. The goal of this article was twofold: to measure isotopic variations between samples of different geographical origin and to produce calibrated isotope ratios with the smallest achievable uncertainty (as defined according to the ISO Guide to the Expression of Uncertainty in Measurement). In the first step, the molar ratio of the isotopes 235U and 238U, n(235U)/n(238U), was measured using a UF6-gas-inlet isotope mass spectrometer (VARIAN MAT 511). This instrument was calibrated against gravimetrically prepared synthetic isotope mixtures thus allowing SI-traceable measurements to be made. The ratios of the “minor isotopes” to 238U [n(234U)/n(238U) and n(236U)/n(238U)] were determined in a second step using a thermal ionisation mass spectrometer with high abundance sensitivity (Finnigan MAT262-RPQ-PLUS). The mass-fractionation correction was done internally using the result of the n(235U)/n(238U) measurement. As a result, the complete measured uranium isotopic composition is traceable to the SI system. For all ratios n(234U)/n(238U), n(235U)/n(238U), and n(236U)/n(238U) significant differences for samples of different origin were found. Regarding the n(236U)/n(238U) results, only two samples, one of them from the Oklo reactor in Gabon, showed significant presence of 236U. For all other samples an upper limit for n(236U)/n(238U) of about 6 × 10−10, mainly dependent on the instrumentation, was found. As a result of this study we propose values for the isotope abundances of natural uranium for the “Best Measurement from a Single Terrestrial Source” and the “Range of Natural Variations” in the IUPAC-table of the “Isotopic Composition of the Elements.”  相似文献   

10.
A fission track technique was used as a sample preparation method for subsequent isotope abundance ratio analysis of individual uranium containing particles with secondary ion mass spectrometry (SIMS) to measure the particles with higher enriched uranium efficiently. A polycarbonate film containing particles was irradiated with thermal neutrons and etched with 6 M NaOH solution. Each uranium containing particle was then identified by observing fission tracks created and a portion of the film having a uranium containing particle was cut out and put onto a glassy carbon planchet. The polycarbonate film, which gave the increases of background signals on the uranium mass region in SIMS analysis, was removed by plasma ashing with 200 W for 20 min. In the analysis of swipe samples having particles containing natural (NBL CRM 950a) or low enriched uranium (NBL CRM U100) with the fission track–SIMS method, uranium isotope abundance ratios were successfully determined. This method was then applied to the analysis of a real inspection swipe sample taken at a nuclear facility. As a consequence, the range of 235U/238U isotope abundance ratio between 0.0276 and 0.0438 was obtained, which was higher than that measured by SIMS without using a fission track technique (0.0225 and 0.0341). This indicates that the fission track–SIMS method is a powerful tool to identify the particle with higher enriched uranium in environmental samples efficiently.  相似文献   

11.
This paper presents the application of a multicollector inductively coupled plasma mass spectrometer (MC–ICP–MS)—a Nu Plasma HR—equipped with three ion-counting multipliers and coupled to a laser ablation system (LA) for the rapid and sensitive determination of the 235U/238U, 236U/238U, 145Nd/143Nd, 146Nd/143Nd, 101Ru/(99Ru+99Tc) and 102Ru/(99Ru+99Tc) isotope ratios in microsamples collected in the vicinity of Chernobyl. Microsamples with dimensions ranging from a hundred μm to about 1 mm and with surface alpha activities of 3–38 mBq were first identified using nuclear track radiography. U, Nd and Ru isotope systems were then measured sequentially for the same microsample by LA–MC–ICP–MS. The application of a zoom ion optic for aligning the ion beams into the ion counters allows fast switching between different isotope systems, which enables all of the abovementioned isotope ratios to be measured for the same microsample within a total analysis time of 15–20 min (excluding MC–ICP–MS optimization and calibration). The 101Ru/(99Ru+99Tc) and 102Ru/(99Ru+99Tc) isotope ratios were measured for four microsamples and were found to be significantly lower than the natural ratios, indicating that the microsamples were contaminated with the corresponding fission products (Ru and Tc). A slight depletion in 146Nd of about 3–5% was observed in the contaminated samples, but the Nd isotopic ratios measured in the contaminated samples coincided with natural isotopic composition within the measurement uncertainty, as most of the Nd in the analyzed samples originates from the natural soil load of this element. The 235U/238U and 236U/238U isotope ratios were the most sensitive indicators of irradiated uranium. The present work yielded a significant variation in uranium isotope ratios in microsamples, in contrast with previously published results from the bulk analysis of contaminated samples originating from the vicinity of Chernobyl. Thus, the 235U/238U ratios measured in ten microsamples varied in the range from 0.0073 (corresponding to the natural uranium isotopic composition) to 0.023 (corresponding to initial 235U enrichment in reactor fuel). An inverse correlation was observed between the 236U/238U and 235U/238U isotope ratios, except in the case of one sample with natural uranium. The heterogeneity of the uranium isotope composition is attributed to the different burn-up grades of uranium in the fuel rods from which the microsamples originated. Electronic supplementary material The online version of this article (doi:) contains supplementary material, which is available to authorized users.  相似文献   

12.
As a result of the accident at the Chernobyl nuclear power plant (NPP) the environment was contaminated with spent nuclear fuel. The 236U isotope was used in this study to monitor the spent uranium from nuclear fallout in soil samples collected in the vicinity of the Chernobyl NPP. Nuclear track radiography was applied for the identification and extraction of hot radioactive particles from soil samples. A rapid and sensitive analytical procedure was developed for uranium isotopic ratio measurement in environmental samples based on double-focusing inductively coupled plasma mass spectrometry (DF–ICP–MS) with a MicroMist nebulizer and a direct injection high-efficiency nebulizer (DIHEN). The performance of the DF–ICP–MS with a quartz DIHEN and plasma shielded torch was studied. Overall detection efficiencies of 4×10–4 and 10–3 counts per atom were achieved for 238U in DF–ICP–QMS with the MicroMist nebulizer and DIHEN, respectively. The rate of formation of uranium hydride ions UH+/U+ was 1.2×10–4 and 1.4×10–4, respectively. The precision of short-term measurements of uranium isotopic ratios (n = 5) in 1 μg L–1 NBS U-020 standard solution was 0.11% (238U/235U) and 1.4% (236U/238U) using a MicroMist nebulizer and 0.25% (235U/238U) and 1.9% (236U/238U) using a DIHEN. The isotopic composition of all investigated Chernobyl soil samples differed from those of natural uranium; i.e. in these samples the 236U/238U ratio ranged from 10–5 to 10–3. Results obtained with ICP–MS, α- and γ-spectrometry showed differences in the migration properties of spent uranium, plutonium, and americium. The isotopic ratio of uranium was also measured in hot particles extracted from soil samples.  相似文献   

13.
Zheng J  Yamada M 《Talanta》2006,68(3):932-939
The determination of uranium is important for environmental radioactivity monitoring, which investigates the releases of uranium from nuclear facilities and of naturally occurring radioactive materials by the coal, oil, natural gas, mineral, ore refining and phosphate fertilizer industries, and it is also important for studies on the biogeochemical behavior of uranium in the environment. In this paper, we describe a quadrupole ICP-MS (ICP-QMS)-based analytical procedure for the accurate determination of U isotope ratios (235U/238U atom ratio and 234U/238U activity ratio) in sediment samples. A two-stage sample cleanup using anion-exchange and TEVA extraction chromatography was employed in order to obtain accurate and precise 234U/238U activity ratios. The factors that affect the accuracy and precision of U isotope ratio analysis, such as detector dead time, abundance sensitivity, dwell time and mass bias were carefully evaluated and corrected. With natural U, a precision lower than 0.5% R.S.D. for 235U/238U atom ratio and lower than 2.0% R.S.D. for 234U/238U activity ratio was obtained with less than 90 ng uranium. The developed analytical method was validated using an ocean sediment reference material and applied to an investigation into the uranium isotopic compositions in a sediment core in a brackish lake in the vicinity of U-related nuclear facilities in Japan.  相似文献   

14.
Nearshore surface sediments from various locations of the West Coast of India were leached by saturated ammonium carbonate solution for the extraction of uranium isotopes. The reagent chosen was found to have high efficiency for leaching uranium isotopes without attacking the mineral core of the sediment particle. The activity ratios of234U/238U are in the range of 1.11 to 1.14 and the activity ratios of235U/235U are in the range of 0.045 to 0.047. The respective activity ratios in leachates, and residues after removal of surface organic matter from the sediment particles by treatment with hydrogen peroxide and 0.05M HCl, revealed disequilibrium between238U and234U only in the surface organic matter. The activity ratios of234U/238U and235U/238U have also been determined in some seawater samples from the Arabian Sea.  相似文献   

15.
Samples of coastal marine sediments of the East Coast of India were leached with a saturated solution of ammonium carbonate for the extraction of uranium from the sediment particle surface without attacking the mineral core of the particles. All the sediment samples were found to exhibit a234U/238U activity ratio in the range of 1.07 to 1.14. On removal of surface organic matter, the234U/238U activity ratio is close to 1.00, indicating that the anomaly between238U and234U exists only on the labile surface layer. However, no such variations are observed in235U/238U activity ratios. These ratios are close to 0.045 which is the same as that of natural uranium.  相似文献   

16.
A simple, rapid and reliable method was developed for the simultaneous determination of uranium and plutonium isotopes by alpha-spectrometry using a single source. A new uranium tracer230U was applied as well as the236Pu tracer to determine overall yields of uranium and plutonium isotopes throughout the entire procedure employed. The analytical procedure consists of sample leaching with 8N HNO3 solution, purification by solvent extraction, simultaneous electrodeposition of U and Pu, and subsequent alpha-spectrometry with a silicon detector. In the solvent extraction using TOA/xylene from 8N HNO3 solution, the preferential extractability of Pu rather than U permits to purify simultaneously the trace amounts of Pu and the macro amounts of U, as in the case of ordinary soil samples, resulting in favourable peak heights for both isotopes. From a single alpha-spectrum, the determinations of238U,234U (and their ratio of234U/238U),239+240Pu, and238Pu contents were conveniently carried out after correcting the overall yields obtained from230U and236Pu activities in the same spectrum. This analytical method was satisfactorily applied to the determination of U and Pu isotope contents in some soils.  相似文献   

17.
The smear samples of the penetrator were analyzed for the determination of the uranium composition. The obtained relative composition (m/m) of uranium isotopes in all the smear samples is in the range of 99.76-99.78% for 238U, 0.000659-0.000696% for 234U, 0.213-0.234% for 235U, and 0.00274-0.00328% for 236U, showing characteristics of depleted uranium (DU). The uranium concentrations in Kosovo soil and water samples as well as biological samples were investigated. It was found that the uranium concentrations in the Kosovo soil samples are in the range of 11.3-2.26·105 Bq·kg-1 for 238U, 10.3-3.01·104 Bq·kg-1 for 234U, 0.60-3251 Bq·kg-1 for 235U, and £0.019-1309 Bq·kg-1 for 236U. The obtained activity ratios are in the range of 0.112-1.086 for 234U/238U, 0.0123-0.1144 for 235U/238U, and 0-0.0078 for 236U/238U, indicating the presence of DU in about 77% of the surface soil samples. At a specific site, the DU inventory in the surface soil is about 140 mg·cm-2, which is 1.68·106 times higher as the estimated mean DU dispersion rate in the region. The uranium concentrations in Kosovo lichen, mushroom, bark, etc., are in the range of 1.97-4.06·104 Bq·kg-1 for 238U, 0.48-5158 Bq·kg-1 for 234U, 0.032-617 Bq·kg-1 for 235U, and £0.019-235 Bq·kg-1 for 236U with mean activity ratios of 0.325±0.0223 for 234U/238U, of 0.0238±0.0122 for 235U/238U, and 0.0034±0.0028 for +U/238U, indicating the presence of DU in the entire sample. On the contrary, the uranium concentrations in Kosovo water samples are low, compared with the water samples collected in central Italy, indicating the presence of negligible amount of DU. The uranium isotopes in Kosovo waters do not constitute a risk of health at the present time. This revised version was published online in July 2006 with corrections to the Cover Date.  相似文献   

18.
Uranium concentration in groundwater reflect both redox conditions and uranium content in host rock. In the present study an attempt has been made to study the uranium concentration and activity ratios of uranium isotopes to present the geochemical conditions of the groundwater in Malwa region of Punjab state, India and the reason for high uranium levels and variation of activity ratios from secular equilibrium conditions. Uranium concentration in groundwater samples was found to be in the range of 13.9 ± 1.2 to 172.8 ± 12.3 μg/l with an average value of 72.9 μg/l which is higher than the national and international guideline values. On the basis of uranium concentration, the groundwater of the study region may be classified as oxidized aquifer on normal uranium content strata (20 %) or oxidized aquifer on enhanced uranium content strata (80 %). The 238U, 235U and 234U isotopic concentration in groundwater samples was found to be in the range of 89.2–1534.5, 4.4–68.5, and 76.4–1386.2 mBq/l, respectively. Activity ratios of 234U/238U varies from 0.94 to 1.85 with a mean value of 1.11 which is close to unity that shows secular equilibrium condition. High value of 234U isotope than 238U may be due to alpha recoil phenomenon. The plot of AR of 234U/238U against the total uranium content in log scale reveals that the groundwaters of the study region either belongs to stable accumulation or normal oxidized aquifer.  相似文献   

19.
A round-robin for uranium isotopic analysis in two solutions with different concentrations prepared and certified by the Institute for Reference Materials and Measurements (IRMM, Geel, Belgium) was organized by CETAMA, a division of the Commissariat à l’énergie Atomique (CEA: French Atomic Energy Commission Fourteen laboratories took part in the program using twenty-five different instruments (ICP-QMS, ICP-SFMS and TIMS). For each solution and each isotopic ratio, a statistical analysis based on standard ISO 5725 was carried out to calculate the mean, the repeatability and reproducibility standard deviations, the z-score and zeta-score, the bias with respect to the target values, and to compare their precision. The mean measurement results for the 234U/238U and 235U/238U isotopic ratios show no significant biases compared with the target values, whatever is the analytical technique. The results were much less satisfactory for the 236U/238U isotopic ratio, for which only the laboratories specialized in traces analyses and/or precise isotopic analyses submitted results in good agreement with the target values. A detailed discussion is given in this article.  相似文献   

20.
The234U/238U and235U/238U ratios from uranium compounds by -spectrometry technique have been obtained. Ten commercially available uranium reagents were analyzed. The well-separated peaks corresponding to uranium isotopes are evident, providing an energy spectrum of the -particles of uranium isotopes. It was found that some commerical uranium salts were depleted in234U and235U.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号