首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
An improvement of the peak parking technique is described for the serial determination of cations (Na+, , K+, Mg2+, and Ca2+) and anions (Cl, , and ) using a single pump, a single eluent and a single detector. The present system used commercially-available unmodified cation exchange and anion exchange columns, which were attached to each switching valve. When 1.75 mM 5-sulfosalicylic acid was used as the eluent, serial separation of the above cations and anions was achieved in less than 20 min. The proposed ion chromatographic method was successfully applied to the serial determination of cations and anions in tap water and river water samples. The limits of detection at S/N=3 for an injection of 20 μl were 16–68 ppb (μg/l) for cations and 15–28 ppb for anions.  相似文献   

2.
The application of ion chromatography with the single pump cycling‐column‐switching technique was described for the analysis of trace inorganic anions in weak acid salts within a single run. Due to the hydrogen ions provided by an anion suppressor electrolyzing water, weak acid anions could be transformed into weak acids, existing as molecules, after passing through the suppressor. Therefore, an anion suppressor and ion‐exclusion column were adopted to achieve on‐line matrix elimination of weak acid anions with high concentration for the analysis of trace inorganic anions in weak acid salts. A series of standard solutions consisting of target anions of various concentrations from 0.005 to 10 mg/L were analyzed, with correlation coefficients r ≥ 0.9990. The limits of detection were in the range of 0.67 to 1.51 μg/L, based on the signal‐to‐noise ratio of 3 and a 25 μL injection volume. Relative standard deviations for retention time, peak area, and peak height were all less than 2.01%. A spiking study was performed with satisfactory recoveries between 90.3 and 104.4% for all anions. The chromatographic system was successfully applied to the analysis of trace inorganic anions in five weak acid salts.  相似文献   

3.
The application of ion chromatography with the column‐switching technique for the simultaneous analysis of peroxydisulfate and conventional inorganic anions in a single run is described. With this method, conventional inorganic anions were separated by consecutive elution through both the guard column and separation column, but peroxydisulfate that only passed through the guard column had a good peak shape and short retention time. A series of standard solutions consisting of target anions of various concentrations from 0.01 to 75 mg/L were analyzed, with a correlation coefficient (r) ≥ 0.9990. The limits of detection were in the range of 0.49–9.84 μg/L based on the S/N of 3 and a 25 μL injection volume. RSDs for retention time, peak area, and peak height were all <1.77%. A spiking study was performed with satisfactory recoveries between 97.6 and 103.4% for all anions. The quantitative determination of peroxydisulfate and conventional inorganic anions in surface waters was accomplished within 18 min by this column‐switching technique.  相似文献   

4.
离子色谱法同时分析啤酒中的有机酸和无机阴离子   总被引:6,自引:0,他引:6  
建立了以NaOH-甲醇混合淋洗液,离子交换色谱柱,电导检测器检测,分离啤酒中有机酸和无机阴离子的离子色谱法.结果表明:在20 min内分离出啤酒中的11种主要有机酸与无机阴离子,方法回收率和相对标准偏差分别为96.30%~104.8%和0.02%~4.0%.  相似文献   

5.
An ion chromatography(IC) system coupled with on-line column-switching technique was used to determine anions ofμg/g levels in organic chemicals of analytical reagent grade.A novel polystyrene-divinylbenzene-carbon nanotube(PS-DVB-CNT) stationary phase was utilized for matrix elimination.A calibration study was conducted by preparing and analyzing eight concentrations(between 10 and 5000μg/L) of eight standards in deionized water.The linearity was between 0.9978 and 1.And the detection limits ranged from 1.54μg/L to 10.02μg/L.A spiking study was performed on two representative organic chemicals.The recoveries were between 84.3%and 119.6%.  相似文献   

6.
An ion chromatography method is described for the simultaneous determination of anions (Cl, NO3, and SO42–) and cations (Na+, NH4+, K+, Mg2+, and Ca2+) using a single pump, a single eluent and a single detector. An anion-exchange column modified with chondroitin sulfate C facilitated the elution of the above three anions using 5 mM tartaric acid as the eluent in isocratic mode, whereas the same eluent facilitated the separation of the above five cations on a commercially-available cation-exchange column. The separation columns were connected in series via two six-port switching valves, so the required cation-exchange or anion-exchange separation could be carried out by selecting the appropriate positions for the switching valves. The separations were completed in 30 min.  相似文献   

7.
Summary The paper describes the separation of the mixture of alkynaphthalenes from distillation cuts of a pyrolysis oil, by preparative liquid chromatography on silica. The design of the system permits the connection of the columns to form multicolumn systems.The samples were first separated on a single column. The mixtures were further separated using two-column chromatography systems.The obtained fractions were analyzed by capillary gas chromatography. In most cases a substantial increase in the concentrations of the individual components was achieved. In several cases, pure compounds have been obtained. Separation efficiency increases in the following order: single column, two directly coupled collumns, two-step switching chromatography, heartcutting.  相似文献   

8.
Summary Retention characteristics of metoprolol have been studied in reversed phase mode on RP2, RP8 and CN columns. The plots of retention time as a function of the acetonitrile content and of the ionic strength of the mobile phase permitted the choice of the best conditions to separate metoprolol from plasma components by switching of these three types of columns.Human plasma (0.5–1 ml) diluted with water is first injected on a RP2 column (25–40 m particle diameter, prepared by dry packing) and rinsed with water. The sample is then back eluted with acetonitrile-0.022 M acetate buffer (7525, v:v) and switched to a CN column (10 cm long, 5 m particle diameter). The heart cut of the eluate is selected and loaded on a RP8 analytical column (25 cm long, 5 m particle diameter) with acetonitrile-0.088 M acetate buffer (7525, v:v) as mobile phase.Auto-sampler and switching valves are actuated automatically by a computing integrator based on a fixed time schedule. The duration of one cycle is about 30 min, but the last analytical step is about 15 min and represents the time interval between two injections. Metoprolol, its alpha-hydroxy metabolite and the internal standard are detected by fluorescence (ex= 225 nm; em > 320 nm).Presented at the 14th International Symposium on Chromatography London, September, 1982  相似文献   

9.
A two-dimensional ion chromatography (2D-IC) approach has been developed which provides greater resolution of complex samples than is possible currently using a single column. Two columns containing different stationary phases are connected via a tee-piece, which enables an additional eluent flow and independent control of eluent concentration on each column. The resultant mixed eluent flow at the tee-piece can be varied to produce a different eluent concentration on the second column. This allows analytes strongly retained on the first column to be separated rapidly on the second column, whilst maintaining a highly efficient, well resolved separation of analytes retained weakly on the first column. A group of 18 inorganic anions has been separated to demonstrate the utility of this approach and the proposed 2D-IC method provided separation of this mixture with resolution of all analytes greater than 1.3. Careful optimisation of the eluent profiles on both columns resulted in run times of less than 28 min, including re-equilibration. Separations were performed using isocratic or gradient elution on the first column, with an isocratic separation being used on the second column. Switching of the analytes onto the second column was performed using a gradient pulse of concentrated eluent to quickly elute strongly retained analytes from the first column onto the second column. The separations were highly repeatable (RSD of 0.01–0.12% for retention times and 0.08–2.9% for peak areas) and efficient (typically 8000–260,000 plates). Detection limits were 3–80 ppb.  相似文献   

10.
An ion chromatography (IC) method has been proposed for the determination of seven common inorganic anions (F(-), H(2)PO(4)(-), NO(2)(-), Cl(-), Br(-), NO(3)(-), and SO(4)(2-)) and/or five common inorganic cations (Na(+), NH(4)(+), K(+), Mg(2+), and Ca(2+)) using a single pump, a single eluent and a single detector. The present system used cation-exchange and anion-exchange columns connected in series via a single 10-port switching valve. The 10-port valve was switched for the separation of either cations or anions in a single chromatographic run. When 1.0mM trimellitic acid (pH 2.94) was used as the eluent, the seven anions and the five cations could be separated on the anion-exchange column and the cation-exchange column, respectively. The elution order was found to be F(-)相似文献   

11.
This work reports an ion chromatographic (IC) method for the quantitative determination of inorganic cations (Na+, K+, Mg2+ and Ca2+) in biodiesel samples that were synthesized from different vegetable oils and fat. The proposed method uses water extraction, heating and ultrasound. The limits of detection (LOD) for each ion, in milligrams of the analyte per kilogram of biodiesel (mg kg−1), were respectively: 0.11 (Na+); 0.42 (K+); 0.23 (Ca2+); and 0.36 (Mg2+). The accuracy of the method was studied through recovery tests. For comparison, two samples were also analyzed using an Inductively Coupled Plasma Optical Emission Spectrometry (ICP-OES) procedure. The paired Student t test and the Snedecor F test showed that both methods offer equivalent results in terms of accuracy and precision. The operational simplicity, accuracy and precision of the proposed method suggest that it can be a good alternative for the determination of inorganic cations in biodiesel samples.  相似文献   

12.
Summary A method is presented for the separation of purine and pyrimidine nucleotides, nucleosides and bases in one analysis. This method uses both the ion-exchange and the reversed-phase modes for the analysis of these compounds. The modes are coupled through automatic switching valves. The use of these valves permits the isolation of either column during the analysis. The nucleotides are separated on an anion-exchange column and the nucleosides and bases on a C-18 column. Total analysis time is approximately one hour, and a very small volume of a sample can be analyzed. The technique is flexible and mobile phase conditions for one column can be altered without affecting the resolution on the other column. The method is applicable to biological matrices.  相似文献   

13.
离子色谱法测定乙二醇中微量有机酸和无机阴离子   总被引:2,自引:0,他引:2  
建立了以YSA-8阴离子交换柱的离子色谱法分析乙二醇中微量有机酸和无机阴离子的方法,比较了进样乙二醇浓度对F-及有机酸测定结果的影响,进样乙二醇质量分数低于8.5%时,能够得到较准确的数据.用本法对所测的有机酸和无机阴离子检出限均在8.9 μg/L以下,线性相关系数r在0.996~0.999范围内,标准样中各物质的离子峰面积的相对标准偏差(RSD)在4.2%以下(n=11),对乙二醇质量分数约为8.5%的样品中F-及有机酸的加标回收率在91.6%~100.0%之间,乙二醇含水料直接测定无机阴离子的加标回收率在91.8%~104.8%之间.  相似文献   

14.
Conventional silica columns dynamically modified with cetyltrimethylammonium ions were evaluated for the determination of UV-absorbing bromide, nitrate, and nitrite in seawater samples. Cetyltrimethylammonium, which is a quaternary ammonium ion, was dynamically introduced onto silica surfaces. The first layer of the modifier was introduced by electrostatic interaction, whereas the second layer was introduced by hydrophobic interaction. The latter layer worked as the anion-exchange sites. The modified conventional silica columns could be used for separation of inorganic anions. Separation of authentic mixture of five anions was achieved within 17 min. The addition of 0.1 mM cetyltrimethylammonium ion to the eluent improved the repeatability of the retention time. Seawater samples could be directly injected onto the prepared conventional silica columns, and bromide, nitrate, and nitrite levels were determined to be 69, 0.13, and 0.016 ppm, respectively.  相似文献   

15.
I. Isildak 《Chromatographia》1999,49(5-6):338-342
Summary An all solid-state contact tubular PVC-matrix membrane electrode has been applied for potentiometric detection of inorganic and organic monovalent anions using phosphate and hydrogen phosphate eluents at low concentrations. This is a “monovalent detection method” as the selectivity of the electrode towards monovalent anions results in some other anions being undetected unless the concentration of those other anions is higher than 10−3 mol dm−3 in the sample solution injected. It takes only eight minutes to complete the separation with a good resolution. Theoretical and practical considerations are discussed, and in particular, sensitivity, linearity, detection limit and dynamic behaviour are presented. The use of an all solid-state contact bromide-selective electrode as a detector offers so far the best simultaneous sensitivity toward all anions when compared with other detection methods. Determination of Cl and NO3 ions in river, rain and drinking water samples without any further sample preconcentration has been successfully achieved. The detection limit is sub-ppb for most of anions in a 20 μL injection volume.  相似文献   

16.
实验采用超声提取离子色谱法测定土壤中常见无机阴离子的含量,以正交试验优化土壤中阴离子的提取条件。研究土壤粒径、料液比、提取功率、提取时间对土壤中阴离子提取量的影响。结果表明:土壤中阴离子提取的最佳条件为A1B2C3D3。即超纯水为提取液,土壤粒径为180μm,料液比为1:30,超声波作用时间为40 min,提取功率为320W,提取次数为一次。该方法可用于土壤中常见可溶性无机阴离子含量的提取测定。  相似文献   

17.
In this work,a novel hollow fiber membrane extractor was set up to extract inorganic anions from ethyl acetate using deionized water.Inorganic anions in slightly soluble organic solvents can be determined by the in-line hollow fiber membrane extractor coupled with ion chromatography at first time.Different aspects of the extraction procedure such as magnetic stirring speed, extraction flow rate and extraction time were optimized to achieve high extraction efficiency and good separation results. Satisfact...  相似文献   

18.
19.
A new capillary electrophoretic approach for simultaneous separation of fast anions and cations is demonstrated. Indirect UV detection at 214 nm in conjunction with electromigration sampling from both ends of the capillary was developed. Two electrolyte systems based on imidazole-nitrate and copper(II)-ethylenediamine-nitrate were investigated for the simultaneous separation of chloride, sulphate, hydrocarbonate, potassium, ammonium, calcium, sodium and magnesium ions. Experimental parameters that were evaluated included a nature of UV chromophore, pH of electrolyte, a nature of complexing agent. The method permits the excellent separation of three anions and five cations in only 4 min using electrolyte system containing 2.5 mmol l−1 Cu(NO3)2, 5 mmol l−1 ethylenediamine and 1 mmol l−1 fumaric acid at pH 8.5 adjusted with tetraethylammonium hydroxide.  相似文献   

20.
Ion-exclusion chromatography (ICE) followed by ion chromatography (IC) was used for the determination of trace anionic contaminants in concentrated weak acids. The ICE separation was used as a pretreatment step to isolate the contaminant anions of strong acids from the excess of matrix ions. Then a fraction containing the analyte ions was separated using IC with suppressed conductivity detection. Microbore–ion-exchange columns were chosen to address the increased purity requirements for use of these concentrated acids in semiconductor applications. The chromatographic conditions were optimized for determining trace chloride, sulfate, phosphate, and nitrate in concentrated 24.5% (v/v) hydrofluoric acid; trace chloride, sulfate, and nitrate in concentrated 85% (w/w) phosphoric acid and trace chloride and sulfate in concentrated 0.7% (v/v) glycolic acid. Method detection limits for the anions of interest were below 100 μg/l.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号