首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
A reversed-phase high-performance liquid chromatographic method with electrochemical detection for the quantitative determination of diclofenac potassium in plasma was developed. Naproxen was used as the internal standard. The drug and internal standard were isolated from plasma by extraction with dichloromethane and 2 M hydrochloric acid. Chromatographic separation was performed on a C18 column with methanol-water (68:32, v/v) adjusted to pH 3.2 with phosphoric acid as mobile phase. The oxidation potential for detection was established by constructing a voltammogram for diclofenac. The quantification limit for diclofenac in plasma was 5 ng mL(-1). Linearity of the method was confirmed in the range 5-2000 ng mL(-1), correlation coefficient 0.9998. Within-day relative standard deviations (RSDs) ranged from 0.66 to 14.00% and between-day RSDs from 0.59 to 15.78%. The method was successfully applied for the determination of pharmacokinetic parameters after ingestion of a 50 mg dose of diclofenac. Studies were performed on 18 healthy volunteers of both sexes.  相似文献   

3.
A simple and sensitive method for the determination of thiamazole in serum by high-performance liquid chromatography with electrochemical detection is described. Thiamazole in serum was quantified without an extraction procedure at concentrations down to 10 ng/ml. This method was applied to determine the serum concentration of the drug in two healthy volunteers given a single oral dose of 10 mg of thiamazole. The concentration of the drug reached a maximum at 3-4 h after the oral dose and two elimination phases were observed.  相似文献   

4.
S. Ito  T. Kato  K. Fujita 《Chromatographia》1986,21(11):645-647
Summary 5-S-Cysteinyldopamine, a new metabolite of dopamine, was determined in urine by high-performance liquid chromatography with electrochemical detection. The catechol was detected in 14 of 21 melanoma patients and 7 of 21 normal subjects; the highest values were 657 μg/day for melanoma patients and 44 μg/day for normal subjects. These results suggest that the cysteine conjugate may arise from autoxidation of dopamine but tyrosinase may also participate in the oxidation.  相似文献   

5.
6.
An air-sampling method for bisphenol A utilizing 13-mm glass fibre filters was developed. The collection efficiency and desorption characteristics were determined. Liquid chromatographic conditions were optimized for the electrochemical detection of bisphenol A. Detection under acidic and alkaline conditions is discussed. The detection minimum is 25 ng/m3 for a 60-1 sample.  相似文献   

7.
Glutathione in biological samples is extracted by perchloric acid and separated by ion-paier chromatography on a RP-18 phase. In a post-column reaction, glutathione is converted to an isoindole derivative by reaction with o-phthalaldehyde and detected at a galssy carbon electrode at 800 mV v. Ag/AgCl/3 M KCl. The detection limit is 40 pmol of glutathione injected.  相似文献   

8.
A rapid method for the analysis of deoxynivalenol (DON) was developed using high-performance liquid chromatography (HPLC) with reductive electrochemical detection (ED). Deoxynivalenol produced by Fusarium roseum growing on solid cornmeal and rice substrates and from naturally contaminated wheat was extracted and quantitated via ED. DON levels in wheat were verified by gas chromatography and structurally confirmed by mass spectrometry. DON was optimally resolved by HPLC employing a radially compressed octadecylsilane column and a mobile phase of deoxygenated methanol-40 mM borate buffer (35:65) at a flow-rate of 1.0 ml/min. Under these conditions DON exhibited an average retention time of 3.6 min. Reductive ED (-1.4 V) allowed a 12-fold increase in sensitivity and greater selectivity than classical UV absorption at 224 nm. A detection limit for DON of 25 pg/microliter was achieved under these conditions. The determination of DON in crude grain extracts was hindered by extractable interfering substances, whereas ED was more functional-group selective (i.e. reduction of the carbonyl moiety). ED permits a direct quantitation of DON from crude grain extracts and may facilitate the determination of this agent and associated metabolites in biological samples.  相似文献   

9.
10.
The possibility of the amperometric detection of a number of pesticides, such as benomyl, thiram, linuron, metoxuron, desmedipham, dicuron, lenacil, and fludioxonil, widely used in agrochemical practice was studied. The effect of the working electrode material (glassy carbon, nickel, and gold) and the type of the electrochemical cell on the value of the analytical signal was studied using the example of thiram. It was found that the optimum potential of the working electrode in analyzing a pesticide mixture was 1400 mV. The dependence of the analytical signal on the pesticide concentration was shown to be linear. The detection limits for the analytes were calculated. Using a 100-μL sample loop, all of the studied pesticides can be determined at the level of the maximum permissible concentration (MPC). The amperometric determination of seven pesticides at the level of MPC in real samples was shown by the examples of model mixtures dissolved in tap water and beetroot juice.  相似文献   

11.
A rapid HPLC method with electrochemical detection for the determination of free and total sulphite and ascorbic acid in beer and other beverages is presented. Interferences of these compounds are discussed, in addition to the behaviour in buffer solutions of different pH. Only a dilution step is required before injecting the sample into the chromatographic system. To obtain better specificity for these compounds, two different working electrodes (platinum for sulphite and carbon glass for ascorbic acid) with distinct potentials are used.  相似文献   

12.
13.
14.
15.
A simple and sensitive HPLC method that does not require derivatization for determining cholesterol has been developed. Investigation of voltammetric behavior of cholesterol showed that cholesterol could be oxidized on a glassy carbon electrode in non-aqueous solvents. This was applied to the development of a method by HPLC with electrochemical detection (HPLC-ED). The HPLC-ED was optimized using the separation of cholesterol and oxysterols including 26-hydroxycholesterol and 24S-hydroxycholesterol. The separation was carried out with a Develosil C30-UG-3 column; acetonitrile-2-propanol (9:1, v/v) containing 50mM LiClO(4) as a mobile phase; and an applied potential at 1.9V versus Ag/AgCl. The current peak height was linearly related to the amount of cholesterol injected from 0.5-100 microM (r>0.999). The detection limit (S/N=3) of cholesterol was 0.36 microM (1.8 pmol). Cholesterol at 100 microM was directly detected with a relative standard deviation (RSD) of less than 1.0% (n=8). Total cholesterol and free cholesterol in control human serum were determined by the present method with the recovery of more than 90% and the RSD (n=6) of less than 3.0%.  相似文献   

16.
17.
A method for the determination of oestriol in pregnancy urine by normal-phase high-performance liquid chromatography with electrochemical detection is described. A large-volume wall-jet cell with an Ag-Ag+ reference electrode was used as the detector system. The limit of detection obtained is comparable to that of electrochemical detection following reversed-phase liquid chromatography. One of the advantages of electrochemical detection with normal-phase systems is that adsorption problems are minimized.  相似文献   

18.
A procedure for determining human platelet monoamine oxidase (MAO) with dopamine (DA) as substrate is described. High-performance liquid chromatography (HPLC) with electrochemical detection (ED) was used to separate and detect components of the reaction mixture. The method for platelet preparation was also improved and only 2 ml of blood were required. Following a 10-min incubation of the platelet preparation with DA in 0.1 M Tris buffer (pH 9.0), excess DA substrate was removed by adsorption on a cation-exchange resin. The reaction product, 3,4-dihydroxyphenylacetaldehyde, was adsorbed on acid-washed alumina, eluted with 0.1 M perchloric acid and analyzed by HPLC. Simple, clean chromatograms were obtained with good reproducibility using 3,4-dihydroxybenzylamine as an internal standard. The within-sample, between-samples and between-day relative standard deviations were 0.9, 3.7 and 6.1%, respectively. The apparent Michaelis constant and maximum velocity were 0.10 mM and 0.37 nmol/min.mg protein, respectively. This HPLC-ED method offers a good alternative to methods using radioactivity.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号