首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 78 毫秒
1.
Gaseous ionic alkyllead species (in the ng Pb m?3 range) are collected from air by absorption in water. After extraction into n-hexane, they are propylated or butylated and quantified by gas chromatography/electrothermal atomic absorption spectrometry. Interference from inorganic lead compounds and aerosol-phase alkyllead compounds is entirely absent, whilst that from tetraalkyllead compounds is small and generally negligible. This method allows the unequivocal identification of gaseous ionic alkyllead species in the atmosphere.  相似文献   

2.
Analyses of fish and other environmental samples (clams, macrophytes, sediments and waters) from areas upstream and downstream from two alkyllead manufactures beside the St Lawrence and St Clair Rivers, Ontario, show a clear indication of elevated alkyllead levels in samples near the industries. Most species of fish contained alkyllead compounds with tetraethyllead and triethyllead as the predominant forms. Most fish from the contaminated areas contained 50–75% of total lead as alkylleads. Carp, yellow perch and white sucker were generally the most contaminated species while pike, alewife and rock bass were the least contaminated. Average alkyllead levels varied from year to year but declined steadily after 1981. For example, the geometric mean of alkyllead compounds in carp from the St Lawrence River decreased from 4207 μg kg?1 in 1981 to 2000 μg kg?1 in 1982 and to 49 μg kg?1 in 1987, reflecting the reduction of alkylleads in the effluents and the closure of one of the manufactures in 1985. Alkyllead levels were consistently lower in muscle and carcass samples in comparison with whole fish containing fatty intestines. However, muscle levels were generally equal to carcass levels. The concentrations of alkyllead compounds were generally low in clams, macrophytes, sediments and waters except from the immediate vicinity of the manufactures' final effluent discharges.  相似文献   

3.
A method for determining carbonyl emissions from motor vehicles was developed in which exhaust gases from test vehicles running on a dynamometer are directly collected in 6-L Teflon bags and then introduced into pentafluorophenyl hydrazine -coated adsorbent tubes for derivatisation and subsequent analysis of generated derivatives by GC/MS. Twenty gasoline and LPG light-duty vehicles were sampled at a vehicle inspection station in Guangzhou, China, by running test vehicles over a transient testing cycle and analysed for carbonyls. Results show that the method can achieve a detection limit of 8–28 ng m?3 for individual carbonyls with a relative standard deviation of 14.5%. Twenty-four carbonyls were identified in the gasoline vehicle exhaust gases and their total concentration was 19.2 mg m?3. For the LPG vehicles, 20 carbonyls were found in the exhaust gases with a total concentration of 4.71 mg m?3. Based on the results, carbonyl emission factors for the gasoline and LPG vehicles were estimated to be 25.0 and 7.36 mg km?1, respectively.  相似文献   

4.
An activated carbon from Coconut (Cocos nucifera) shells was prepared by physical activation with carbon dioxide and water vapor. The activated carbon obtained has a surface area of 1058 m2 g?1 and such a high micropore volume of 0.49 cm3 g?1. This carbon was studied for the removal of lead from water. Sorption studies were performed at 30 °C, at different pH and adsorbent doses, in batch mode. Lead precipitation was observed on the surface of the activated carbon. Maximum adsorption occurred at pH 9 for an adsorbent dose of 2 g L?1. Kinetic studies, at the initial concentration of 150 mg L?1 of lead, pH 5 and an adsorbent dose of 1 g L?1, yielded an equilibrium time of 50 h for this activated carbon. The kinetic data were modeled with the pseudo first order, the pseudo second order and the Bangham models. The pseudo second order model fitted the data well. The sorption rate constant (7 × 10?4 mol?1 Kg s?1) and the maximum amount of lead adsorbed (0.23 mol kg?1) are quite good compared to the data found in literature. Sorption equilibrium studies were conducted in a concentration range of lead from 0 to 150 mg L?1. In an aqueous lead solution with an initial concentration of 30 mg L?1, at pH 5, adsorbent dose 1 g L?1, activated Coconut shell carbon removed at equilibrium 100 % of the heavy metal. The equilibrium data were modeled with the Langmuir and Freundlich equations, of which the former gave the best fit. The Langmuir constants Qmax eq (0.23 mol kg?1) and KL (487667 L mol?1) are in good agreement with literature. XPS studies identified adsorbed species as lead carbonates and/or lead oxalates and precipitates as lead oxide and/or lead hydroxide on the activated carbon surface. The Coconut shell activated carbon is a very efficient carbon due to its high surface area, to the presence of many micropores on its surface and to the presence surface groups like hydroxyls promoting adsorption in the porous system and lead crystal precipitation on the activated carbon surface.  相似文献   

5.
A new solid-phase extraction method utilising polyacrylonitrile activated carbon fibres (PAN-ACFs) as adsorbent was developed for the preconcentration of trace metal ions prior to their determination by inductively coupled plasma optical emission spectrometry (ICP-OES). The PAN-ACFs oxidised with nitric acid were characterised by FT-IR, XRD, SEM and BET analysis. Then the resulting PAN-ACFs were used as solid-phase adsorbent for simultaneously determination of trace Al(III), Be(II), Bi(III), Cr(III), Cu(II), Fe(III) and Pb(II) ions in aqueous solutions. The influences of the analytical parameters on the recoveries of the studied ions were investigated. The optimum experimental conditions of the proposed method were pH: 6.0; eluent concentration and volume: 3.0 mL of 1.5 mol L?1 nitric acid; flow rates of sample and eluent solution: 1.5 mL min?1. The preconcentration factors were found to be 67 for Al(III), Bi(III); 83 for Cr(III), Cu(II), Fe(III) and 50 for Be(II), Pb(II). The precision of this method was in range of 1.5%~3.5% and the detection limit of this metal ions was between 0.06~1.50 μg L?1. The developed method was validated by the analysis of a certified reference sample and successfully applied to the determination of trace metal ions in water samples with satisfactory results.  相似文献   

6.
A manual method for the determination of hydrogen chloride in air, based on diffusion/denuder tube separation from particulate chloride aerosol is described. When air is drawn through a tube coated with a selective absorbent (sodium fluoride), separation is achieved because gaseous hydrogen chloride diffuses much more rapidly to the tube walls than particulate chloride aerosol, which passes through virtually unabsorbed. After the sampling period (the length of which depends on the concentration of gaseous hydrogen chloride expected), the sorbed hydrogen chloride is washed from the tube and measured with a highly sensitive chloride ion-selective electrode with a mercury (I) chloride membrane. The method is examined theoretically and experimentally. The experimentally derived absorption efficiencies of the diffusion/denuder tubes were > 90% and the standard deviation of the method was 0.023 μg m?3 for hydrogen chloride concentrations of 0.16–0.55 μg m?3. Interference from particulate chloride salts was negligible; this was confirmed by tests with artificially generated aerosol particles from an aerosol generator. The diffusion/denuder tubes have high capacity; level as high as 330 μg m?3 hydrogen chloride can be sampled for 60 min without affecting performance. A detection limit of (50/t) μg m?3 can be achieved, where t is the sampling rime (min); e.g., 1μg m?3 hydrogen chloride can be detected with a sampling period of 50 min.  相似文献   

7.
Ammonia is important in atmospheric chemistry because it neutralises acidic species and increases the pH of cloud droplets. Data on the concentration of free ammonia in the atmosphere are sparse because it is difficult to separate free ammonia from particulate ammonium salt aerosol. A manual method for the determination of free ammonia in air is described based on diffusion/denuder tube separation of ammonia from ammonium salt aerosol. When air is drawn through a tube coated with a selective absorbent (here oxalic acid) separation is achieved because the gaseous species diffuses much more rapidly to the tube wall than the particles. After the sampling period (usually 1–4 h, depending on the free ammonia concentration expected), the sorbed ammonia is washed from the tube and measured potentiometrically with an ammonia probe. The method is tested theoretically and experimentally. The absorption efficiency of the coated tubes is ca. 90%. In samples of room air containing 12–28 μg m?3, the standard deviation is estimated as 1.0 μg m?3. In field use, ammonia contents were in the range 0.53–5.0 μg m?3.  相似文献   

8.
The aim of this study was to evaluate the surface adsorption capacity of CrFeO3 nanoparticle‐loaded activated carbon (CrFeO3‐NPs–AC) for the removal of a cationic dye (methyl violet, MV). CrFeO3‐NPs were hydrothermally synthesized and loaded on AC followed by characterization using X‐ray diffraction, field‐emission scanning electron microscopy and energy‐dispersive and Fourier transform infrared spectroscopies. The CrFeO3‐NPs were tested for in vitro antibacterial activities against Gram‐positive (Staphylococcus aureus) and Gram‐negative (Pseudomonas aeruginosa) bacteria. Minimum inhibitory and minimum bactericidal concentrations of CrFeO3‐NPs–AC were obtained to be 50 and 100 μg ml?1, respectively, against S. aureus and 25 and 50 μg ml?1 against P. aeruginosa. These results indicated the antibacterial properties of CrFeO3‐NPs–AC. To investigate the adsorption process, several systematic experiments were designed by varying parameters such as adsorbent mass, pH, initial MV concentration and sonication time. The adsorption process was modelled and the optimal conditions were determined to be 0.013 g, 7.4, 15 mg l?1 and 8 min for adsorbent mass, pH, MV concentration and sonication time, respectively. The real experimental data were found to be efficiently explained by response surface methodology and genetic algorithm model. Kinetic studies for MV adsorption showed rapid sorption dynamics described by a second‐order kinetic model, suggesting a chemisorption mechanism. Then, the experimental equilibrium data obtained at various concentrations of MV and adsorbent masses were fitted to conventional Langmuir, Freundlich, Temkin and Dubinin–Radushkevich isotherm models. Dye adsorption equilibrium data were fitted well to the Langmuir isotherm. From the Langmuir model, the maximum monolayer capacity was calculated to be 65.67 mg g?1 at optimum adsorbent mass.  相似文献   

9.
Single phase gasoline–ethanol–water mixture was prepared for performing standardization with aqueous standards and for the elimination of difficulties with pipetting of gasoline. Standard addition calibration method was applied to the determination of Cu, Pb and Co in gasoline by electrothermal atomic absorption spectrometry. Good agreements were found for the analysis results of the present “direct” method compared with those obtained by digesting gasoline in microwave furnace with nitric acid. The limit of detection values were 1.5 μg kg−1 Co, 2.5 μg kg−1 Cu and 4.0 μg kg−1 Pb in original gasoline samples.  相似文献   

10.
This paper presents the results of atmospheric air quality research in Tczew (adjacent to the Vistula River) on the content of BTEX compounds. procedure applied during the sampling of the analytes from the air used the passive sampling technique (diffusive passive sampler, Radiello®). For determination of BTEX compounds in atmospheric air, two-stage thermal desorption technique combined with gas chromatography (TD-GC-FID) was applied.

Research was conducted from March to December 2011. The annual average concentration of benzene, toluene, ethylbenzene and total xylenes determined in atmospheric air for the monitoring period were: 0.87 μg m–3, 2.9 μg m–3, 1.3 μg m–3 and 5.9 μg m–3, respectively. In order to pre-identify potential sources of emissions of BTEX compounds, statistical analysis was carried out. This determined interactions between specified concentration levels of BTEX compounds in atmospheric air for the monitored area.  相似文献   

11.
A procedure for the determination of atmospheric particulate lead by flameless atomic absorption spectrometry is described. Aerosols are collected on 10-cm Whatman 41 filters with high-volume pumps. The lead is removed from a one-eighth sector of the filter by two ultrasonic treatments in 0.1 M nitric acid for 10 and 5 min, respectively. Investigations, including comparison with samples pre-ashed at low temperature, indicated that the lead was completely recovered. Routinely 20-μ1 amounts of the solution are injected into a graphite tube and the % absorption at 283.3 nm is measured. The elements normally encountered in atmospheric aerosols do not interfere. The sensitivity for 24-h samples is 0.01 μg m?3 of air. Sampling time can be reduced to a few minutes in urban air when a larger segment of the filter is used and a larger volume is injected. The reproducibility of the complete procedure is 3% for a typical lead concentration of 0.35 μg m?3. The method was applied to short-period variations of the lead concentration in urban air.  相似文献   

12.
An on-line column preconcentration method based on the combined use of ammonium O,O-diethyldithiophosphate and activated carbon or polyurethane foam as adsorbents has been developed for the determination of Pb in water samples. The complexed Pb was eluted with ethanol and determined by flame atomic absorption spectrometry. The optimum preconcentration conditions are given for each adsorbent. The enrichment factors were 63 and 294, and the detection limits (3σ) 3?μg?L–1 and 0.8?μg?L–1, respectively, for the carbon and foam systems. When the optimized procedures were applied to the determination of Pb in water samples the recovery efficiency was > 96%.  相似文献   

13.
Steam activated carbons from oil-palm shells were prepared and used in the adsorption of phenol. The activated carbon had a well-developed mesopore structure which accounted for 45% of the total pore volume. The BET surface area of the activated carbon was 1183 m2/g and a total pore volume of 0.69 cm3/g using N2 adsorption at 77 K. The adsorption capacity of the activated carbon for phenol was 319 mg/g of adsorbent at 298 K. The adsorption isotherms could be described by both the Langmuir-Freundlich and the Langmuir equations. The adsorption kinetics consisted of a rapid initial uptake phase, followed by a slow approach to equilibrium. A new multipore model is proposed that takes into account of a concentration dependent surface diffusion coefficient within the particle. This model is an improvement to the traditional branched pore model. The theoretical concentration versus time curve generated by the proposed model fitted the experimental data for phenol adsorption reasonably well. Phenol adsorption tests were also carried out on a commercial activated carbon known as Calgon OLC Plus 12×30 and the agreement between these adsorption data and the proposed model was equally good.  相似文献   

14.
Two series of activated carbon have been prepared by chemical activation of Amygdalus Scoparia shell with phosphoric acid or zinc chloride for the removal of Pb(II) ions from aqueous solutions. Several methods were employed to characterize the active carbon produced. The surface area was calculated using the standard Brunauer-Emmet-Teller method. The microstructures of the resultant activated carbon were observed by scanning electron microscopy. The chemical composition of the surface resultant activated carbon was determined by Fourier transform infrared spectroscopy. In the batch tests, the effect of pH, initial concentration, and contact time on the adsorption were studied. The data were fitted with Langmuir and Freundlich equations to describe the equilibrium isotherms. The maximum adsorption capacity of Pb(II) on the resultant activated carbon was 36.63 mg g−1 with H3PO4 and 28.74 mg g−1 with ZnCl2. To regenerate the spent adsorbents, desorption experiments were performed using 0.25 mol L−1 HCl. Here we propose that the activated carbon produced from Amygdalus Scoparia shell is an alternative low-cost adsorbent for Pb(II) adsorption.  相似文献   

15.
A 2,2′‐azinobis (3‐ethylbenzothiazoline‐6‐sulfonate) diammonium salt (ABTS)‐multiwalled carbon nanotubes (MWCNTs) nanocomposite/Bi film modified glassy carbon (GC) electrode was constructed for the differential pulse stripping voltammetric determination of trace Pb2+ and Cd2+. This electrode was more sensitive than ABTS‐free Bi/GC and Bi/MWCNTs/GC electrodes. Linear responses were obtained in the range from 0.5 to 35 μg L?1 for Cd2+ and 0.2 to 50 μg L?1 Pb(II), with detection limits of 0.2 μg L?1 for Cd2+ and 0.1 μg L?1 for Pb2+, respectively. This sensor was applied to the simultaneous detection of Cd2+ and Pb2+ in water samples with satisfactory recovery.  相似文献   

16.
Abstract

In the present work, a novel composite consisting of magnetite, activated carbon from spent coffee grounds and natural clay (MACCC) was prepared by a one-pot synthesis method via a simultaneous activation and magnetization processes. Various techniques (XRD, FTIR, SEM, TEM, EDX, BET) were utilized to characterize the synthesized composite before utilizing it as an adsorbent for removal of Cu(II), Ni(II) and Pb(II) ions from aqueous solutions. Conditions for removal of heavy metals were thoroughly optimized as 25?°C, pH of 5.5, adsorbent dosage of 2?g L?1, and a contact time of 60?min. Three models of pseudo first-, second-order and intraparticle diffusion as well as three models of Langmuir, Freundlich, and Temkin were used to analyze kinetics and isotherms of the adsorption process. Thermodynamics was discussed completely. Regeneration and recyclability of the adsorbent were also evaluated. Based on the analysis of experimental results, a possible adsorption mechanism of heavy metals onto the synthesized composite was proposed. The maximum capacities caculated from Langmuir model followed the order of Pb(II) > Cu(II) > Ni(II) as 143.56, 96.16 and 84.86?mg·g?1, respectively. The overall results indicated that MACCC is a potential adsorbent for removal of toxic Pb(II), Cu(II) and Ni(II) ions from wastewater due to simple preparation, high removal efficiency and good recyclability.  相似文献   

17.
Bismuth film modified and chemically activated carbon micro‐thread electrodes were investigated for the simultaneous determination of Cd(II) and Pb(II) using square wave anodic stripping voltammetry. The carbon thread electrode was characterised using both surface and electrochemical techniques. Electrochemical impedance spectroscopy (EIS) studies demonstrated that the H2SO4/IPA‐treated carbon thread electrode showed a much improved resistance response (Rct=23 Ω) compared to the IPA‐untreated carbon thread (Rct=8317 Ω). Furthermore, parameters such as the effect of deposition potential, deposition time and Bi(III) concentration were explored using square wave voltammetry. Detection limits (S/N=3) for Cd(II) and Pb(II) were found to be 1.08 µg L?1 and 0.87 µg L?1, respectively and response was found to be linear over the range 5–110 µg L?1. The proposed Bi/IPA‐treated carbon thread electrode exhibited a high selectivity towards Cd(II) and Pb(II) even in the presence of a range of heavy metals and is capable of repetitive and reproducible measurements, being attributed to the high surface area, geometry and electrode treatment characteristics. The proposed metal ion sensor was employed to determine cadmium and lead in river water samples and % RSD was found to be 5.46 % and 5.93 % for Cd(II) and Pb(II) respectively (n=3). Such facile sensing components favour the development of cost effective portable devices for environmental sample analysis and electrochemical applications.  相似文献   

18.
In this work,we reported a simultaneous determination approach for Pb(II),Cd(II)and Zn(II)atμg L 1concentration levels using differential pulse stripping voltammetry on a bismuth film electrode(BiFE).The BiFE could be prepared in situ when the sample solution contained a suitable amount of Bi(NO)3,and its analytical performance was evaluated for the simultaneous determination of Pb(II),Cd(II)and Zn(II)in solutions.The determination limits were found to be 0.19μg L 1for Zn(II),and0.28μg L 1for Pb(II)and Cd(II),with a preconcentration time of 300 s.The BiFE approach was successfully applied to determine Pb(II),Cd(II)and Zn(II)in tea leaf and infusion samples,and the results were in agreement with those obtained using an atomic absorption spectrometry approach.Without Hg usage,the in situ preparation for BiFE supplied a green and acceptability sensitive method for the determination of the heavy metal ions.  相似文献   

19.
A novel adsorbent, 3-amino-propylsilica gel-multi-walled carbon nanotubes (APSG-MW), was prepared by chemical bonding multi-walled carbon nanotubes on silica gel. The surface area of APSG-MW was 98 m2/g, and the particle size was between 60 and 80 mesh with the average size of 215.0 μm. The adsorption capability of the new adsorbent to volatile organic compounds (VOCs) was measured. The effect of water to the adsorbent and its stability during storage were also investigated. Duplicate precision (DP) and distributed volume pair (DVP) on the basis of the EPA TO-17 criteria were estimated. The results showed that the sampling precision of the adsorbent was more superior compared to the MWCNTs because of the better air permeability. The new adsorbent was successfully applied in the determination of VOCs in ambient indoor air.  相似文献   

20.
《Electroanalysis》2006,18(2):177-185
In this article, the results of some recent investigations on two types of bismuth‐modified carbon paste electrodes are presented. In the first study, the bismuth‐film carbon paste electrode (BiF‐CPE) operated in situ and employed in anodic stripping voltammetry of Cd(II) and Pb(II) at the low μg L?1 level was of interest in view of choosing the proper Bi(III)‐to‐Me(II) concentration ratios (where Me: Pb or Cd). Such optimization has resulted in significant improvement of detection limits down to 1.0 μg L?1 Cd and 0.8 μg L?1 for Pb, which allowed us to apply the BiF‐CPE for analysis of selected real samples of tap and sea water. The BiF‐CPE was also further investigated for its application in highly alkaline media. In this case, attention was focused on the complex‐forming capabilities of the OH ions and their effect on the anodic stripping characteristics of some heavy metals (i.e. Cd, Pb, Tl) as well as upon the formation of the bismuth film itself. The last example deals with the continuing characterization of the recently introduced carbon paste electrodes modified with bismuth powder (Bi‐CPEs) which combine the advantageous properties of carbon paste material with the favorable electrochemical properties of bismuth. Three series of electrodes, differing either in the content of metallic bismuth (from 8 to 50% w/w) or in the type of the carbon powder used (two spectroscopic types of graphite and powdered glassy carbon), were compared and the respective relations to the optimal carbon paste composition evaluated. Attractive electroanalytical performance of the Bi‐CPE in anodic stripping voltammetry is demonstrated for selected model mixtures of heavy metals (Mn, Zn, Cd, Pb, Tl, and In).  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号