首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
An electrochemical immunosensor for polychlorinated biphenyl (PCB) detection based on graphite screen-printed low-density arrays and on magnetic beads is reported.The immunological reaction for the detection of PCBs is based on a direct competitive assay using alkaline phosphatase (AP) as enzymatic label. After the immunochemical recognition, the modified magnetic beads are captured by a magnet on the surface of the graphite working electrode. The electrochemical detection is thus achieved through the addition of the AP substrate (α-naphthyl-phosphate).Two different antibodies (sIgG anti-PCB28 and rIgG anti-PCB77) were tested and compared in terms of sensitivity and ability to recognise different congeners. The developed electrochemical magneto-immunosensor (EMI) was successfully combined with solid-phase extraction (SPE) for the analysis of PCBs in milk samples. In spiked samples a recovery of 80% was obtained. The proposed strategy offers great promise for rapid, simple, cost-effective, and on-site analysis of clinical, food and environmental samples, considering also that low-density arrays allow the simultaneous analysis of different processed samples.  相似文献   

2.
S. Centi  S. Laschi  M. Mascini 《Talanta》2007,73(2):394-399
A comparison of two electrochemical immunosensing strategies for PCBs detection, based on the use of two different solid phases, is here discussed. In both cases, carbon-based screen-printed electrodes (SPEs) are used as transducers in a direct competitive immunoassay scheme, where PCBs in solution compete with the tracer PCB28-alkaline phosphatase (AP) labeled for antibodies immobilized onto the solid-phase.In the standard format (called EI strategy), SPEs are both the solid-phase for immunoassay and electrochemical transducers: in this case the immunochemical reaction occurs onto the working electrode. Finally, the enzymatic substrate is added and an electroactive product is generated and detected by electrochemical measurement. In order to improve the performances of the system, a new approach (called EMI strategy) is developed by using functionalized magnetic beads as solid phase for the competitive assay; only after the immunosensing step they are captured by a magnet onto the working surface of the SPE for the electrochemical detection.Experimental results evidenced that the configuration based on the use of separate surfaces for immunoassay and for electrochemical detection gave the best results in terms of sensitivity and speed of the analysis. The improvement of analytical performances of the immunosensor based on EMI strategy was also demonstrated by the analysis of some spiked samples.  相似文献   

3.
A simple, rapid, and highly sensitive bioelectrochemical immunoassay method based on magnetic beads (MBs) and disposable screen-printed electrodes (SPE) has been developed to detect polychlorinated biphenyls (PCBs). The principle of this bioassay is based on a direct competitive enzyme-linked immunosorbent assay using PCB-antibody-coated MBs and horseradish peroxidase (HRP)-labeled PCB (HRP-PCB). A magnetic process platform was used to mix and shake the samples during the immunoreactions and to separate free and unbound reagents after the liquid-phase competitive immunoreactions among PCB-antibody-coated MBs, PCB analyte, and HRP-PCB. After a complete immunoassay, the HRP tracers attached to MBs were transferred to a substrate solution containing o-aminophenol and hydrogen peroxide for electrochemical detection. The different parameters, including the amount of HRP-PCB conjugates, immunoreaction time, and the concentration of substrate that governs the analytical performance of the immunoassay have been studied in detail and optimized. The detection limit of 10 pg mL−1 was obtained under optimum experimental conditions. The performance of this bioelectrochemical immunoassay was successfully evaluated with untreated river water spiked with PCBs, and the results were validated by commercial PCB enzyme-linked immunosorbent assay kit, indicating that this convenient and sensitive technique offers great promise for decentralized environmental application and trace PCBs monitoring.  相似文献   

4.
构建了一种基于L-半胱氨酸、 壳聚糖、 戊二醛和纳米金层层自组装技术的新型无标记、 高灵敏电流型免疫传感器, 并用于检测3,3',4,4'-四氯联苯(PCB77). 利用示差脉冲法研究了修饰电极表面的电化学特性以及测试溶液的pH值、 孵育时间和温度对免疫传感器性能的影响. 实验结果表明, 该免疫传感器在含不同浓度PCB77的磷酸盐缓冲溶液(PBS, pH=7.4)中于35 ℃下孵育30 min后, 在含有5 mmol/L K3Fe(CN)6/K4Fe(CN)6(摩尔比1:1)和0.1 mol/L KCl的PBS溶液(pH=6.0)中测定, 响应电流与PCB77浓度在0.1~160 ng/mL范围内呈良好的线性关系, R=0.9964, 检出限为0.01 ng/mL. 该传感器制备简单、 灵敏度高、 稳定性好, 可以重复使用. 将其用于检测实际污泥样品中的PCB77, 回收率为95%~112%.  相似文献   

5.
Biofunctionalizing a simple and disposable graphene oxide-modified screen-printed carbon electrode with anti-interleukin-15 antibodies has been successfully demonstrated for the first time for the label-free electrochemical detection of interleukin-15, a biomarker of early HIV infection. To improve the electrochemical reactivity and introduce carboxylic groups on the surface of screen-printed carbon electrode, high-quality graphene oxide was used for the modification of screen-printed carbon electrode. With simple modification of the screen-printed carbon electrode, the device exhibited satisfactory sensitivity, selectivity, stability, reproducibility, and regenerability. The immunosensor provided a detection limit of 3.51?ng?mL?1 and a sensitivity of 0.5655?µA cm?2?mL?ng?1. The simply constructed immunosensor thus rendered promising device for immunoreactions on the surface of the electrode.  相似文献   

6.
陈向强  何苗  施汉昌  蔡强 《分析化学》2011,39(4):443-448
将微囊藻毒素-(亮氨酸-精氨酸)-鸡卵白蛋白 (Microcystin-(leucinc-arginine)-ovalbumin,MCLR-OVA)固定在锇联吡啶聚(4-乙烯基吡啶)聚合物修饰的丝网印刷碳电极表面,制备了一种检测 MCLR的电流型免疫传感器.该传感器基于间接竞争免疫分析模式,以辣根过氧化物酶偶联的羊抗鼠...  相似文献   

7.
A multiplexed electrochemical immunoassay method was developed for simultaneous ultrasensitive measurement of tumor markers based on electrochemical stripping analysis of silver nanoparticles (Ag NPs). The Ag NPs were deposited on a disposable immunosensor array with a reduction reaction catalyzed by nanogold labels. The immunosensor array was prepared by covalently immobilizing capture antibodies on chitosan modified screen-printed carbon electrodes. Through a sandwich-type immunoreaction, antibody-functionalized Au NPs were captured onto immunosensor surface to induce the silver deposition from a silver enhancer solution. The deposited Ag NPs could be directly measured by anodic stripping analysis in KCl solution. The catalytic deposition enhanced the analytical sensitivity for detection of protein markers. The interference of dissolved oxygen could be avoided as the detection was performed with positive stripping potential range. Using carcinoembryonic antigen and α-fetoprotein as model analytes, the proposed multiplexed immunoassay method showed wide linear ranges of three orders of magnitude with the detection limits down to 3.5 and 3.9 pg mL−1, respectively. The localized silver deposition, as well as the stripping detection process, eliminated completely the electrochemical cross talk between adjacent immunosensors. The immunosensor array exhibited acceptable reproducibility, stability and accuracy, showing a promising potential in multianalyte determination for clinical application.  相似文献   

8.
An immunosensor for the detection of Listeria monocytogenes was developed. ELISA and amperometric studies were run in parallel to develop a more sensitive and rapid assay for the bacterium. Conditions for the immunosensor were primarily characterised using ELISA. A direct sandwich assay was employed and the affinities of two polyclonal (goat and rabbit) and one monoclonal (mouse) anti-L. monocytogenes antibodies were compared using this format. Owing to low sensitivity being obtained with all antibodies, biotin-avidin amplification and an indirect sandwich assay were employed. The system was then transferred to screen-printed electrodes (SPEs), the primary antibody being immobilised by cross-linking with 1-ethyl-3-(3-dimethylaminopropyl)-carbodiimide, and the mode of detection being amperometric. Various parameters (limit of detection, working range, incubation time, cross-reactivity) of the systems were characterised. The effect of direct incubation in milk is also discussed. The final immunosensor had a working range of 1 x 10(6)-1 x 10(3) cells ml-1 and a detection limit of 9 x 10(2) cells ml-1. The assay took about 3.5 h to complete.  相似文献   

9.
A novel electrochemical immunosensor was developed for the determination of the hormone prolactin. The design involved the use of screen-printed carbon electrodes and streptavidin-functionalized magnetic particles. Biotinylated anti-prolactin antibodies were immobilized onto the functionalized magnetic particles and a sandwich-type immunoassay involving prolactin and anti-prolactin antibody labelled with alkaline phosphatase was employed. The resulting bio-conjugate was trapped on the surface of the screen-printed electrode with a small magnet and prolactin quantification was accomplished by differential pulse voltammetry of 1-naphtol formed in the enzyme reaction using 1-naphtyl phosphate as alkaline phosphatase substrate. All variables involved in the preparation of the immunosensor and in the electrochemical detection step were optimized. The calibration plot for prolactin exhibited a linear range between 10 and 2000 ng mL(-1) with a slope value of 7.0 nA mL ng(-1). The limit of detection was 3.74 ng mL(-1). Furthermore, the modified magnetic beads-antiprolactin conjugates showed an excellent stability. The immunosensor exhibited also a high selectivity with respect to other hormones. The analytical usefulness of the immnunosensor was demonstrated by analyzing human sera spiked with prolactin at three different concentration levels.  相似文献   

10.
A method has been developed for peak identification of PCBs in GC with ECD detection under different temperature programs and isothermal conditions on two commonly used columns (DB-5 and DB-1701). This was achieved by means of accurate calibration of retention times based on the concept of the relative retention index P (i) and retention times of the selected PCB internal standards. The P (i) was calculated from the predicted retention times with the database of the retention parameters (A, B) and the migration equations. Through comparison of the calibrated and experimental retention times of PCBs in technical samples, it was shown that the developed method was effective for correct PCB comprehensive, quantitative, congener-specific (CQCS) analyses.  相似文献   

11.
An immunosensor for rapid and low level detection of the bacterial pathogen Salmonella enterica Serovar Typhimurium was designed and developed based upon label‐free electrochemical impedance spectroscopy and correlated to viable cell counts. The immunosensor was fabricated by electroplating gold onto a disposable printed circuit board (PCB) electrode by immobilizing monoclonal antibody (MAb) specific against Salmonella typhimurium cell surface lipopolysaccharide (LPS) onto the surface of the electrode. Use of mass‐fabricated and electroplated PCB electrodes allowed for disposable, highly sensitive, and rapid detection of Salmonella in an aqueous environment. Results demonstrate that in purified solution, Salmonella can be detected as low as 10 CFU in a 100 μL volume and label‐free and rapid manner in fewer than 90 s. The cost effective approach described here can be used for detection of pathogens with relevance for healthcare, food, and environmental applications.  相似文献   

12.
Qi H  Ling C  Ma Q  Gao Q  Zhang C 《The Analyst》2012,137(2):393-399
A novel electrochemical immunosensor array for the simultaneous detection of multiple tumor markers was developed by incorporating electrochemically addressing immobilization and one signal antibody strategy. As a proof-of-principle, an eight-electrode array including six carbon screen-printed working electrodes was used as a base array for the analysis of two important tumor markers, carcinoembryonic antigen (CEA) and α-fetoprotein (AFP) and a horseradish peroxidase-labeled antibody was employed as a signal antibody. The immunosensor in the array was fabricated in sequence by covalently coupling the capture antibody onto the surface of the desired working electrode, which was firstly electrochemically addressably grafted with an aminophenyl group by reduction of in situ generated aminophenyl diazonium cation generated from p-phenylenediamine, using glutaraldehyde as cross-linker. This allowed the selective immobilization of the capture antibody at the desired position on a single array via an electrochemical operation. The immunoassay in sandwich mode was performed by specifically binding the targets, second antibodies and one signal antibody to the immunosensor array. The result showed that the steady current density was directly proportional to the concentration of target CEA/AFP in the range from 0.10 to 50 ng mL(-1) with a detection limit of 0.03 ng mL(-1) for CEA and 0.05 ng mL(-1) for AFP (S/N = 3), respectively. This work demonstrates that the employment of an electrochemically addressing method for the fabrication of an immunosensor array and one signal antibody is a promising approach for the determination of multiple tumor markers in clinical samples.  相似文献   

13.
We present two kinds of electrochemical immunoassays for the tumor necrosis factor α (TNF-α) which is a protein biomarker. The antibody against TNF-α was immobilized on a graphite screen-printed electrode modified with poly-anthranilic acid (ASPE). The first is based on impedimetry (and thus label-free) and the target antigen (TNF-α) is captured by the surface of the modified electrode via an immunoreaction upon which impedance is changed. This sensing platform has a detection limit of 5.0 pg mL?1. In the second approach, the monoclonal antibodies on the modified electrode also bind to the target antigen (TNF-α), but detection is based on a sandwich immunoreaction. This is performed by first adding secondary anti-TNF-α antibodies labeled with horseradish peroxidase, and then detecting the response of the sandwich system by adding hydrogen peroxide and acetaminophen as a probe system for HRP activity. This immunosensor also has a very low detection limit (3.2 pg mL?1). The experimental conditions of both assays were studied and optimized via electrochemical impedance spectroscopy and differential pulse voltammetry. The method was then applied to the determination of TNF-α in serum samples where it displayed high sensitivity, selectivity and reproducibility.
Figure
A novel electrochemical immunosensor capable of sensitive and selective detection of tumor necrosis factor α is developed. It is based on the poly-anthranilic acid modified graphite screen-printed electrodes. Validation was made by analyzing human serum.  相似文献   

14.
Human serum certified reference material (CRM), NMIJ CRM 7407-a, for the analysis of polychlorinated biphenyls (PCBs) was developed by the National Metrology Institute of Japan. A pool of commercially available human serum was used as a raw material of the CRM. This sample is in the form of a liquid comprising approximately 4 g stored in a cryogenic polypropylene vial. Homogeneity assessment was performed, and the material was homogeneous enough for PCB 118, PCB 138, PCB 153, and PCB 194: the relative uncertainties due to inhomogeneity were 2.5–10.5%. The results obtained from the stability assessment indicated that the target PCBs were stable: the relative uncertainties due to instability were 0–14.7%. The certification was carried out using two different types of GC columns for each target PCB to avoid interferences on GC separation; the certified values of the target PCBs (PCB 118, PCB 138, PCB 153, and PCB 194) were 9.7–129.8 ng/kg. This is the first frozen human serum CRM in which PCBs were determined by isotope dilution mass spectrometry.  相似文献   

15.
Zhang M  Dai W  Yan M  Ge S  Yu J  Song X  Xu W 《The Analyst》2012,137(9):2112-2118
An ultrasensitive electrochemiluminescence (ECL) immunosensor was developed using PtAg@carbon nanocrystals (CNCs) as excellent labels based on carbon nanotubes-chitosan/AuNPs (CNT-CHIT/AuNPs) composite modified screen-printed carbon electrodes (SPCEs) for prostate protein antigen (PSA) detection. The CNCs were obtained simply by electro-oxidation of graphite with abundant carboxyl groups at their surfaces. The PtAg bimetallic nanocomposites with hierarchically hollow structures were fabricated through simple replacement reaction using dealloyed nanoporous silver (NPS) as both a template and reducing agent. Structure characterization was obtained by means of transmission electron microscope (TEM) and scanning electron microscope (SEM) images. The PtAg@CNCs composites exhibit a 6 times higher ECL intensity than the pure CNCs labeled anti-PSA. The as-prepared CNT-CHIT/AuNPs composite can attach more antibody than pure CNTs. Due to the dual-amplification techniques, the concentrations of PSA were obtained in the range from 1 pg mL(-1) to 50 ng mL(-1) with a detection limit of 0.6 pg mL(-1). Finally, the as-proposed ECL immunosensor has the advantages of high sensitivity, specificity and stability and could become a promising technique for tumor marker detection.  相似文献   

16.
非等间隔PCBs保留指数体系在光解行为研究中的应用   总被引:1,自引:0,他引:1  
苗秀生  储少岗  徐晓白 《色谱》1997,15(6):465-469
利用Chu等已建立的多氯联苯(PCBs)非等间隔保留指数体系,由文献中的相对保留时间计算出全部209种PCBs同类物(Congener)的保留指数(IPCB)。利用IPCB结合GC-MS对PCB87、PCB138和PCB169三种同类物的光解产物进行了定性分析,发现其光解产物主要为低氯代联苯。实验结果证明,非等间隔保留指数体系IPCB在PCBs同类物的定性分析中具有准确、实用、快捷、方便等优点。  相似文献   

17.
The concentration of anti-transglutaminase antibodies in human sera is an important analytical marker for the diagnosis of the autoimmune disorder celiac disease. In this work, an immunosensor for the electrochemical detection of anti-transglutaminase antibodies in human sera was developed. The immunosensor is based on the immobilization of transglutaminase onto screen-printed gold electrodes which were covered with a polyelectrolyte layer of poly (sodium-4-styrensulfonic acid). The antigen-antibody interaction was evaluated using an amplification step: incubation with peroxidase (POD)-labeled immunoglobulins and subsequent biocatalytic oxidation of 3-amino-9-ethylcarbazole (AEC). Changes in the interfacial properties of the sensor electrode were determined by electrochemical impedance spectroscopy (EIS). Impedance spectra could be fitted to a Randles equivalent circuit containing a constant phase element (CPE). Furthermore, it was shown that impedance measurements could be simplified by performing EIS at only two selected frequencies, without loss of reliability. Incubation of these disposable immunosensor chips with various anti-transglutaminase antibody concentrations resulted in changes in their charge transfer resistance (Rct). Thereby, a calibration graph could be established. Finally, immunosensors were used for characterizing different human sera with respect to their anti-transglutaminase autoantibody concentration of the IgG and IgA type.  相似文献   

18.
A membrane based heterogeneous competitive enzyme-linked immunosorbent assay (ELISA) was used in this work to develop an immunosensor for the detection of a common herbicide, isoproturon. A screen-printed carbon working electrode with carbon counter and silver–silver chloride pseudo-reference electrode was utilized incorporating a membrane fixed into intimate contact with the working electrode to facilitate signal transduction. The membrane containing an immobilized isoproturon–ovalbumin conjugate was laminated onto the carbon working electrode and horseradish peroxidase (HRP) labeled polyclonal antibody was then applied for the competitive assay. Two different amperometric systems, hydroquinone and o-phenylenediamine (OPD) mediation reduction were utilised and the properties of the resultant sensors were compared. A flow injection apparatus was also developed utilising the immunosensor. Limits of detection for isoproturon (LLD90) were found to be as low as 0.84 ng mL−1. The senor was also validated using spiked extracted soil samples and also isoproturon contaminated samples.  相似文献   

19.
This work designed a simple, sensitive, and low-cost immunosensor for the detection of protein marker by using a carbon sphere/gold nanoparticle (CNS/AuNP) composite as an electrochemical label. The nanoscale carbon spheres, prepared with a hydrothermal method by using glucose as raw material, were used to load AuNPs for labeling antibody by electrostatic interaction, which provided a feasible pathway for electron transfer due to the remarkable conductivity. The disposable immunosensor was constructed by coating a polyethylene glycol (PEG) film on a screen-printed carbon-working electrode and then immobilizing capture antibody on the film. With a sandwich-type immunoassay format, the analyte and then the CNS/AuNP-labeled antibody were successively bound to the immunosensor. The bound AuNPs were finally electro-oxidized in 0.1 M HCl to produce AuCl(4)(-) for differential pulse voltammetric (DPV) detection. The high-loading capability of AuNPs on CNS for the sandwich-type immunorecognition led to obvious signal amplification. By using human immunoglobulin?G (IgG) as model target, the DPV signal of AuNPs after electro-oxidized at optimal potential of +1.40?V for 40?s showed a wide linear dependence on the logarithm of target concentration ranging from 10?pg mL(-1) to 10?ng mL(-1). The detection limit was around 9?pg mL(-1). The immunosensor showed excellent analytical performance with cost effectivity, good fabrication reproducibility, and acceptable precision and accuracy, providing significant potential application in clinical analysis.  相似文献   

20.
《Analytical letters》2012,45(17):2690-2704
A disposable immunosensor for the detection of Escherichia coli O157:H7 based on a multiwalled carbon nanotube–sodium alginate nanocomposite film was constructed. The nanocomposite was placed on a screen-printed carbon electrode, and horseradish peroxidase-labeled antibodies were immobilized to E. coli O157:H7 on the modified electrode to construct the immunosensor. The modification procedure was characterized by atomic force microscopy and cyclic voltammetry. Under optimal conditions, the proposed immunosensor exhibited good electrochemical sensitivity to E. coli O157:H7 in a concentration range of 103–1010 cfu/mL, with a relatively low detection limit of 2.94 × 102 cfu/mL (S/N = 3). This immunosensor exhibited satisfactory specificity, reproducibility, stability, and accuracy, making it a potential alternative tool for early assessment of E. coli O157:H7.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号