首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Enhanced chiral separation performance has been observed for ketoprofen enantiomers in capillary electrochromatography (CEC) with an open-tubular (OT) column prepared with a specific molecule imprinted polymer (MIP) on the innerwall of 50mum ID capillary. The column was prepared by in situ thermal polymerization inside the pretreated and silanized fused silica capillary. A specific diluted monomer mixture composed of S-ketoprofen, methacrylic acid (MAA, functional monomer), ethylene glycol dimethacrylate (EDMA, cross-linker), and 4-styrenesulfonic acid (4-SSA) dissolved in 9/1 (v/v) acetonitrile/2-propanol was used to fabricate the OT-MIP layer. 4-SSA was added to form a MIP layer capable of stable and strong electro-osmotic flow (EOF) over the pH range of this study securing CEC elution of ketoprofen having partial negative charge near the optimized pH. Various parameters such as buffer pH, organic modifier composition, salt concentration, and applied potential have been optimized for CEC chiral separation of ketoprofen enantiomers. Very good separation selectivity and efficiency were observed, thus the chromatographic resolution of ketoprofen enantiomers was as high as 10.5, and the number of theoretical plates of R-ketoprofen, 156,000/m (40,000/m for S-ketoprofen), which proves that the OT-MIP-CEC type approach is a promising strategy in MIP study.  相似文献   

2.
A novel monolithic silica column with zwitterionic stationary phase was prepared by in-situ covalent attachment of phenylalanine to a 3-glycidoxypropyltriethoxysilane-modified silica monolith. Due to the zwitterionic nature of the resulting stationary phase, the density and sign of the net surface charge, and accordingly the direction and magnitude of electroosmotic flow in this column during capillary electrochromatography could be manipulated by adjusting the pH values of the mobile phase. CEC separations of various acidic and basic compounds were performed on the prepared column in anodic and weakly cathodic EOF modes, respectively. The peak tailing of basic compounds in CEC on a silica column could be alleviated at optimized buffer compositions. Besides the electrophoretic mechanism and weak hydrophobic interaction, weak cation- and anion-exchange interactions are also involved in the separations of acids and bases, respectively, on the zwitterionic column.  相似文献   

3.
比值导数紫外吸收光谱法测定阿司匹林中的微量水杨酸   总被引:8,自引:0,他引:8  
本文应用比值导数吸收光谱法于药物阿司匹林中微量水杨酸含量的测定,在0.01 ̄0.12%浓度范围内比值导数光谱峰高与水杨酸浓度成正比。线性相关系数为0.9994,检出限为0.005%,样品测定回收率为95.0% ̄102.5%。将其用于阿司匹林原料中微量水杨酸杂质含量的测定,乙酰水杨酸含量在90.0% ̄99.0%范围内,不干扰微量水杨酸的测定。  相似文献   

4.
刘丽丽  乔娟  张红医  齐莉 《色谱》2020,38(9):1107-1114
针对生物体液样品开展药物的绿色高效毛细管电泳分离分析具有重要的研究意义。该研究以3种解热镇痛药(4-氨基安替比林、氨基比林及非那西汀)为研究对象,以嵌段聚合物为涂层,建立了药物的开管毛细管电色谱(OT-CEC)分析新策略。首先,采用活性/可控自由基可逆加成-断裂链转移聚合方法,合成制备得到了两亲性嵌段聚合物-聚(苯乙烯-甲基丙烯酸缩水甘油酯)(P(St-GMA)),并将其涂覆到毛细管内壁;其次,通过考察影响OT-CEC分离效率的关键因素,包括嵌段聚合物的聚合时间、涂覆毛细管嵌段聚合物的浓度、电泳运行缓冲液的种类和pH值、有机溶剂添加剂等,优化了3种解热镇痛药物的OT-CEC分离条件;最终发现,不需添加任何有机溶剂及表面活性剂,仅采用50.0 mmol/L乙酸钠-乙酸(pH 5.7)作为OT-CEC的缓冲溶液,就能实现3种解热镇痛药物的基线分离。在8.0~2.5×103μmol/L范围内,分析物峰面积与其对应的浓度呈现良好的线性关系,相关系数(R2)均大于0.995,检出限为1.0~2.5μmol/L。结果表明:P(St-GMA)在溶液中自组装...  相似文献   

5.
Torriero AA  Luco JM  Sereno L  Raba J 《Talanta》2004,62(2):247-254
The electrochemical oxidation of salicylic acid (SA) has been studied on a glassy carbon electrode using cyclic voltammetry and differential pulse voltammetric (DPV) method. SA gives a single irreversible oxidation wave over the wide pH range studied. The irreversibility of the electrode process was verified by different criteria. The mechanism of oxidation is discussed. Using differential pulse voltammetry, SA yielded a well-defined voltammetric response in Britton-Robinson buffer solution, pH 2.37 at 1.088 V (versus Ag/AgCl). The method was linear over the SA concentration range: 1-60 μg ml−1. The method was successfully applied for the analysis of SA as a hydrolysis product, in solid pharmaceutical formulations containing acetylsalicylic acid (ASA).  相似文献   

6.
CEC was used to develop a method for the enantiomeric excess determination of levetiracetam, an antiepileptic drug. Different types of calibration curve were evaluated for use in the range between 0.01 and 1 mg/mL when aniracetam was used as an internal standard. The method gave comparable results when only the areas of the impurity were used in the calibration curve. The predicted detection and quantification limits from the S/N were 1.1 and 3.6 microg/mL, respectively. However, experimental results showed that LOD and LOQ were underestimated. Repeatability of injection was demonstrated by the RSD values obtained for retention time, resolution, ratios of the areas impurity/internal standard, and areas of impurity and internal standard individually, which were below or equal to 9.30%. The between-days variability experiments indicated that it is better to make a calibration curve daily. The finally selected calibration curves were used to test the accuracy of the developed method on bulk samples and Keppra tablets containing 250 mg levetiracetam. Both selected calibration curves performed similarly. The one using the internal standard information gave overall recoveries between 88 and 118%, while the one using areas gave results between 84 and 118%.  相似文献   

7.
Wu R  Zou H  Ye M  Lei Z  Ni J 《Electrophoresis》2001,22(3):544-551
A mode of capillary electrochromatography (CEC), based on the dynamical adsorption of surfactants on the uncharged monolithic stationary phases has been developed. The monolithic stationary phase, obtained by the in situ polymerization of butyl methacrylate with ethylene dimethacrylate, was dynamically modified with an ionic surfactant such as the long-chain quaternary ammonium salt of cetyltrimethylammonium bromide (CTAB) and long-chain sodium sulfate of sodium dodecyl sulfate (SDS). The ionic surfactant was adsorbed on the surface of polymeric monolith by hydrophobic interaction, and the ionic groups used to generate the electroosmotic flow (EOF). The electroosmotic mobility through these capillary columns increased with increasing the content of ionic surfactants in the mobile phase. In this way, the synthesis of the monolithic stationary phase with binary monomers can be controlled more easily than that with ternary monomers, one of which should be an ionic monomer to generate EOF. Furthermore, it is more convenient to change the direction and magnitude of EOF by changing the concentration of cationic or anionic surfactants in this system. An efficiency of monolithic capillary columns with more than 140000 plates per meter for neutral compounds has been obtained, and the relative standard deviations observed for to and retention factors of neutral solutes were about 0.22% and less than 0.56% for ten consecutive runs, respectively. Effects of mobile phase composition on the EOF of the column and the retention values of the neutral solutes were investigated. Simultaneous separation of basic, neutral and acidic compounds has been achieved.  相似文献   

8.
Methacrylate-based monolithic columns with electroosmotic flow (EOF) or very weak EOF are prepared by in situ copolymerization in the presence of a porogen in fused-silica capillaries pretreated with a bifunctional reagent. Satisfactory separations of acidic and basic compounds on the column with EOF at either low or high pH are achieved, respectively. With sulfonic groups as dissociation functionalities, sufficient EOF mobility still remains as high as 1.74 x 10(-4) cm2 s(-1) V(-1) at low pH. Under this condition, seven acidic compounds are readily separated within 5.7 min. Moreover, at high pH, the peak shape of basic compounds is satisfactory without addition of any masking amines into running mobile phase since the secondary interaction between the basic compounds and the monolithic stationary phase are minimized at high pH. Reversed-phase mechanism for both acidic and basic compounds is observed under investigated separation conditions. In addition, possibilities of acidic and basic compound separations on a monolithic column with extremely low EOF are discussed.  相似文献   

9.
Ni Y  Su S  Kokot S 《Analytica chimica acta》2006,580(2):206-215
The interactions of salicylic acid (SL) and two different site markers (warfarin for site I and ibuprofen for site II) with bovine serum albumin (BSA) in pH 7.4 Tris–HCl buffer have been investigated with the use of spectrofluorimetry. An equilibrium solution of BSA and SA was titrated separately with the two markers. This initial work showed that the binding of SL with BSA could be quite complex, and that there was probably a competitive interaction occurring between ibuprofen and SL. However, the spectral results were difficult to interpret clearly for the interaction of warfarin and SL in similar circumstances.

To extract more information from the resolution of fluorescence excitation-emission spectra, the contour plots of the fluorescence spectra indicated that the optimal excitation wavelengths for BSA, SL, warfarin and ibuprofen were different, and were found to be at 278, 295, 306 and 218 nm, respectively. The spectral information was arranged into three-way excitation-emission fluorescence matrix (EEM) stack arrays, and was submitted for analysis by the parallel factor analysis (PARAFAC) algorithm. Firstly, it was demonstrated that the estimated excitation and emission spectral responses for SL, BSA and the site markers, warfarin and ibuprofen, agreed well with the measured spectra. Then, the interpretation of the plots of simultaneously extracted (by PARAFAC) equilibrium concentrations for the above four reactants, showed that: (i) the SL primarily appears to bind in site I but at a different location from the high-affinity binding site (HAS) for warfarin, and the interaction partially overlaps with the low-affinity binding site (LAS) for warfarin. (ii) The SL may have two LAS—one in site II where the HAS for ibuprofen is located, and the other in site I at the LAS for ibuprofen. Thus, application of the PARAFAC method for the study of competitive interaction of SL and BSA with the aid of two different site markers has extracted information unobtainable by traditional methods such as the Scatchard plot, and provided useful means of data visualization.  相似文献   


10.
Capillary electrochromatography (CEC) was coupled with mass spectrometry (MS) for the separation of some selected pesticides and drug enantiomers. CEC separations were carried out in fused silica capillaries packed with either 5 μm RP18 silica or 5 μm silica modified vancomycin particles. The capillary column was connected with the MS utilizing a laboratory-made liquid-junction interface equipped with a 50 μm I.D. capillary-tip positioned at a few mm from the orifice of the MS. The CEC–MS set-up was operated without external pressure assistance during the electrochromatographic run commonly used to avoid bubble formation. However a hydrostatic pressure of a few kPa was applied only to the liquid-junction interface to optimize the ion-spray due to the low I.D. of the capillary-tip. In order to optimize the CEC–MS method, several experimental parameters were studied, namely the inlet pressure, the hydrostatic pressure into the liquid-junction interface, the type of sheath-liquid and the mobile phase. The application of an inlet pressure influenced only analyte retention times that were shortened by increasing the pressure. On the contrary the hydrostatic pressure applied to the interface increased the flow rate into the tip also increasing the ion-signal recorded in the mass spectrometry. The ion-signal raised almost linearly by increasing the outlet pressure till 3.5 kPa and then decreased. The separation of the selected pesticides was not influenced at all changing the hydrostatic pressure on the interface. Some basic enantiomeric compounds of pharmaceutical interest were successfully separated by CEC achieving good resolution. They were detected by MS with limit of detection in a range of 0.24–0.60 μg/mL.  相似文献   

11.
This study describes the ability of on-line concentration capillary electrochromatography (CEC) coupled with UV or mass spectrometry (MS) for the determination of nine common non-steroidal anti-inflammatory drugs (NSAIDs) in water samples. A series of poly(stearyl methacrylate-divinylbenzene) (poly(SMA-DVB)) monolithic columns, which were prepared by single step in situ polymerization of divinylbenzene (DVB), stearyl methacrylate (SMA) and vinylbenzenesulfonic acid (VBSA, charged monomer), were developed as separation columns for the first time. The effects of polymerization condition of monolithic columns on analyte separations were examined, and the results indicated that separation performances were markedly improved in monolithic columns prepared with short reaction time (3 h) and low SMA:DVB ratio (40/60 ratio of SMA:DVB). Subsequently, an on-line concentration step of step-gradient elution was combined to this CEC system, and by optimizing the difference in eluent strength between the sample matrix and mobile phase, all NSAIDs detection sensitivity were improved (limit of detection (LOD) was 3.4-10 μg/L for UV, and 0.01-0.19 μg/L for MS). When compared to the best CE and LC reports on NSAIDs analyses so far, this on-line concentration CEC method provided better detection ability within shorter separation time (12 min) when either UV or MS detector was employed. This is the first report for on-line concentration CEC with MS detection applied in trace solute analyses of real samples.  相似文献   

12.
Several acidic xylooligosaccharides containing unsaturated “hexenuronic acid” units, i.e. 4-deoxy-L -threo-hex-4-enopyranosy-lurinic acid (4-ΔU) units, were separated as their alditol derivatives by capillary zone electrophoriesis in 438 mM borate buffer (pH 10.3) and were detected selectively at the μM level on-column UV detection at 232 nm. These acidic oligosaccharides were obtained from birch and pine kraft pulps on enzymatic hydrolysis with endoxylanases and subsequent treatment with other Trichoderma reesei enzymes. Under the conditions empolyed, acidic 4-ΔU-containing xylooligosaccharides with a molecular size renging from trisaccharides up to nonasaccharides could be separated. Oligosaccharides with higher molecular mass were detected first. Two 4-ΔU-xylotetraose isomers, with the 4-ΔU-group linked to different xylose units in the iligosaccharide backbone, could be resolved from each other with a resolution of about 1. By using a disaccharide (4-ΔU α-(1 → 4) linked to N-acetyl glucosamine) as a model compound the minimum detectable concentration was determined as 10 μM.  相似文献   

13.
建立了一种新的开管毛细管电色谱法以用于开展药物与血小板相互作用研究.该方法利用物理吸附将血小板固定于毛细管内壁,并通过改变血小板进样时间控制涂层长度.根据涂层长度与药物淌度的关系,建立了药物与血小板结合常数的计算方程,得出阿司匹林与血小板的结合常数为0.579g-1L,大于阴性对照品帕珠沙星与血小板的结合常数0.249g-1L.最后,用亲和萃取法所得结果与本方法对比,说明了本方法能够用于评价抗凝血药物与血小板的相互作用.  相似文献   

14.
Summary Acidic and neutral compounds have been separated by strong anion-exchange capillary electrochromatography (SAXCEC) dynamically modified by addition of sodium dodecylsulfate (SDS). It was found that separation of neutral solutes by SAXCEC without addition of SDS is difficult because of the weak interaction of the solutes with the hydrophilic packing surface. The hydrophobicity of the packing surface increases on addition of SDS to the mobile phase, however, and the capacity of separating neutral solutes increases. Acidic solutes are retained, mainly because of the ion-exchange properties of this system. The influence of mobile phase composition, e.g. SDS concentration, ionic strength, and organic modifier fraction, on the retention of acidic and neutral solutes was investigated. Three acids and five neutral solutes were separated in only 5 min under optimized conditions, because the direction of the strong electroosmotic flow (EOF) was the same as that of electrophoretic migration of the acids under the conditions used. The repeatability of this system in terms of migration time relative standard deviation (RSD) is good—less than 0.48% for 10 consecutive runs of all the solutes tested. Column efficiencies for acids were > 125000 plates m−1; those for neutral solutes varied from 25000 to 100000 plates m−1.  相似文献   

15.
In completion of an earlier defined generic chiral screening approach, a generic separation strategy for basic, bifunctional, and neutral compounds was proposed and evaluated. This strategy adds to a previously defined strategy for acidic compounds. The screening experiment of the actual strategy used a mobile phase of 5 mM phosphate buffer pH 11.5/ACN (30/70 v/v), a temperature of 25 degrees C, and a voltage of 15 kV. The selected chiral stationary phases were Chiralpak AD-RH, Chiralcel OD-RH, Chiralcel OJ-RH, and Chiralpak AS-RH, all based on polysaccharide selectors. It was seen that 31 out of 48 test compounds were partially or baseline-resolved under screening conditions. After execution of the optimization steps of the strategy, this number increased to 41, with a total of 21 baseline-separated compounds. Combined with the results obtained from the acidic test set examined in the earlier defined strategy, of all tested compounds 82.5% showed enantioselectivity and 49.2% could be baseline-separated.  相似文献   

16.
Liu S  Xie Z  Wu X  Lin X  Guo L  Chen G 《Journal of chromatography. A》2005,1092(2):258-262
In this paper, the pressurized capillary electrochromatography (pCEC) with UV detection was utilized for the separation and determination of three structurally related estrogens, such as diethylstilbestrol (DES), hexestrol (HEX) and dienestrol (DE), which were difficult to be separated by capillary electrophoresis (CE) and HPLC due to their similarity in the structure and charge-to-mass ratios. Experiments were carried out in a commercially available pCEC instrument using a capillary column packed with 3 microm octadecyl silica (ODS). Surfactant sodium dodecyl sulfate (SDS) was introduced in the mobile phase to enhance the speed of analysis. The effective factors on the retention time and separation resolution, such as the applied voltage, supplementary pressure, the pH and the concentration of the buffer solution, the concentration of SDS, and the content of acetonitrile in the mobile phase, were evaluated. Based on the investigation, 31% (v/v) acetonitrile and 69% (v/v) of 10 mmol/L phosphate buffer (pH 6.5) containing 1.0 mmol/L SDS at an applied voltage of -12 kV and a supplementary pressure of 1000 psi were found to be the optimal conditions for pCEC to separate the three estrogens. The method also had been applied to the analysis of fish muscle samples spiked with estrogens.  相似文献   

17.
李振群  贾丽 《色谱》2020,38(9):1046-1056
手性药物通过与生物体内生物大分子之间的手性匹配与分子识别来发挥药理作用。两个对映体与体内手性环境相互作用的不同导致每个对映体表现出不同的药理活性、代谢过程、代谢速率及毒性等药代动力学特征。因此发展手性药物的拆分方法,对于手性药物的开发和生产过程的质量监控具有重要意义。分子印迹聚合物(MIPs)是以目标分子作为模板而制备的高分子聚合物,它具有特定的空间分子结构和官能团,对目标分子具有高度的特异性识别能力。基于该特点,MIPs非常适合于手性药物的拆分和纯化。毛细管电色谱(CEC)可同时基于毛细管电泳和液相色谱的分离机理对目标物进行分离,因此具有高分离效率和高选择性的特点。将MIPs材料作为CEC的固定相,可将这两种技术的优势结合,从而实现对手性药物的高效拆分。MIPs材料在1994年首次应用于CEC手性拆分,此后该研究领域开始获得关注和发展。MIPs材料主要通过4种模式在CEC中实现手性拆分,分别是作为开管柱、填充柱和整体柱的固定相以及分离介质中的准固定相。该综述以这4种模式作为分类基准,根据MIPs制备所需的材料和分离对象对其在CEC手性拆分中的应用进行了总结,揭示了MIPs在CEC手性...  相似文献   

18.
Peak compression effects in capillary electrochromatography of basic drug substances using a strong cation-exchanger have been studied. Extremely narrow peaks with apparent efficiencies of several million plates per meter could be obtained when the composition of the sample zone differed from that of the mobile phase. The increased efficiencies were predominately observed when the analyte had an elution time similar to that of the electroosmotic flow marker. Peak compression was found to be reproducible and could be obtained for all investigated basic drug substances by altering the composition of the mobile phase in such a way that the analyte co-eluted with the sample zone. An explanation of the observed phenomena is proposed. A sample zone differing in composition from the mobile phase will disturb the equilibrium between the stationary and mobile phase. The elution rate of an analyte will consequently be different when residing inside the sample zone. If the analyte migrates through the sample zone at a higher speed than the rest of the mobile phase and is strongly retained after passing through a boundary in the sample zone, a continuous stacking can be obtained trapping the analyte as a very narrow band.  相似文献   

19.
This work describes the separation of acidic, basic and neutral organic compounds as well as inorganic anions in a single run by capillary electrochromatography employing a stationary phase which exhibits both strong anion-exchange and reversed-phase chromatographic characteristics. The positive surface charge of this stationary phase provided a substantial anodic electroosmotic flow. The analytes were separated by a mixed-mode mechanism which comprised chromatographic interactions (hydrophobic interactions, ion-exchange) as well as electrophoretic migration. The influence of ion-exchange and hydrophobic interactions on the retention/migration of the analytes could be manipulated by varying the concentration of a competing ion and/or the amount of organic modifier present in the background electrolyte. Additionally the effects of pH changes on both the chromatographic interactions as well as the electrophoretic migration of the analytes were investigated.  相似文献   

20.
Online sample concentration of acidic drugs by transient isotachophoresis (t-ITP) with the injection of a base is described in capillary zone electrophoresis (CZE). A positively coated capillary was conditioned with background electrolyte (ammonium acetate at pH 6). A long plug of sample solution (S) prepared in ammonium acetate was then hydrodynamically injected followed by the base (tetrapropylammonium hydroxide). A negative voltage was applied and caused the hydroxide ions from the base to penetrate the S zone and created a pH junction that swept through the S zone. The analytes stack at the junction where the mechanism of focusing was transient ITP with the acetate and hydroxide ions as leading and terminating ions, respectively. The concentrated analytes separated in co-EOF CZE once the hydroxide was exhausted. The base stacking strategy was tested using hypolipidemic, nonsteroidal anti-inflammatory, and diuretic drugs, and afforded 19-37 improvements in peak height.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号