共查询到20条相似文献,搜索用时 15 毫秒
1.
Muftuler LT Gulsen G Sezen KD Nalcioglu O 《Journal of magnetic resonance (San Diego, Calif. : 1997)》2002,155(1):39-44
We have developed an MRI RF coil whose tuning can be adjusted automatically between 120 and 128 MHz for sequential spectroscopic imaging of hydrogen and fluorine nuclei at field strength 3 T. Variable capacitance (varactor) diodes were placed on each rung of an eight-leg low-pass birdcage coil to change the tuning frequency of the coil. The diode junction capacitance can be controlled by the amount of applied reverse bias voltage. Impedance matching was also done automatically by another pair of varactor diodes to obtain the maximum SNR at each frequency. The same bias voltage was applied to the tuning varactors on all rungs to avoid perturbations in the coil. A network analyzer was used to monitor matching and tuning of the coil. A Pentium PC controlled the analyzer through the GPIB bus. A code written in LABVIEW was used to communicate with the network analyzer and adjust the bias voltages of the varactors via D/A converters. Serially programmed D/A converter devices were used to apply the bias voltages to the varactors. Isolation amplifiers were used together with RF choke inductors to provide isolation between the RF coil and the DC bias lines. We acquired proton and fluorine images sequentially from a multicompartment phantom using the designed coil. Good matching and tuning were obtained at both resonance frequencies. The tuning and matching of the coil were changed from one resonance frequency to the other within 60 s. 相似文献
2.
PurposeTo evaluate the accuracy of susceptibility estimated from the principles of echo shifting with a train of observations (PRESTO) sequence using a 1.5 T MRI system, we conducted experiments on the human brain using the PRESTO sequence and compared our results with the susceptibility obtained from spoiled gradient-recalled echo (GRE) sequence with flow compensation using quantitative susceptibility mapping (QSM) reconstruction.Materials and methodsExperiments on the human brain were conducted on 12 healthy volunteers (27 ± 4 years) using PRESTO and spoiled GRE sequences on a 1.5 T scanner. The PRESTO sequence is an echo-shifted gradient echo sequence that allows high susceptibility sensitivity and rapid acquisition because of TE > TR compared with the spoiled GRE sequence. QSM analysis was performed on the obtained phase images using the iLSQR method. Estimated susceptibility maps were used for region of interest analyses and estimation of line profiles through iron-rich tissue and major vessels.ResultsOur results demonstrated that susceptibility maps were accurately estimated, without error, by QSM analysis of PRESTO and spoiled GRE sequences. Acquisition time in the PRESTO sequence was reduced by 43% compared with that in the spoiled GRE sequence. Differences did exist between susceptibility maps in PRESTO and spoiled GRE sequences for visualization and quantitative values of major blood vessels and the areas around themConclusionThe PRESTO sequence enables correct estimation of tissue susceptibility with rapid acquisition and may be useful for QSM analysis of clinical use of 1.5 T scanners. 相似文献
3.
This study quantified the impact of the well-known physiologic noise correction algorithm RETROICOR applied to a pain functional magnetic resonance imaging (FMRI) experiment at two field strengths: 1.5 and 3.0 T. In the 1.5-T acquisition, there was an 8.2% decrease in time course variance (σ) and a 227% improvement in average model fit (increase in mean R2a). In the 3.0-T acquisition, significantly greater improvements were seen: a 10.4% decrease in σ and a 240% increase in mean R2a. End-tidal carbon dioxide data were also collected during scanning and used to account for low-frequency changes in cerebral blood flow; however, the impact of this correction was trivial compared to applying RETROICOR. Comparison between two implementations of RETROICOR demonstrated that oversampled physiologic data can be applied by either downsampling or modification of the timing in the RETROICOR algorithm, with equivalent results. Furthermore, there was no significant effect from manually aligning the physiologic data with corresponding image slices from an interleaved acquisition, indicating that RETROICOR accounts for timing differences between physiologic changes and MR signal changes. These findings suggest that RETROICOR correction, as it is commonly implemented, should be included as part of the data analysis for pain FMRI studies performed at 1.5 and 3.0 T. 相似文献
4.
Caroline Mesmann Monica Sigovan Lise-Prune Berner Adva Abergel François Tronc Y. Berthezène P. Douek Loic Boussel 《Magnetic resonance imaging》2014
Purpose
To compare diffusion weighted imaging with background suppression (DWIBS) sequence with classic spectral diffusion sequence (DWI) with and without respiratory gating in mediastinal lymph node analysis at 3 T.Materials and methods
26 patients scheduled for mediastinoscopic lymph node analysis, prospectively undergone a thoracic 3 T MRI with DWIBS (FatSat = STIR; TR/TE = 6674.1/44.7 ms; IR = 260 ms) and DWI sequences (FatSat = SPIR; TR/TE = 1291/59.6 ms) (b = 0-400-800 s/mm2) with and without (free breathing) respiratory gating.Images at b = 800 were analyzed by two radiologists. They performed qualitative analysis of fat-sat homogeneity and motion artifacts, rated from 0 to 4, and quantitative evaluation by studying signal to background (STB) of lymph nodes.Results
Quality of fat suppression was significantly higher for DWIBS than for DWI both for free-breathing (score 3.48 ± 0.65 vs. 1.76 ± 0.96, p < 0.0001) and respiratory-gated scans (3.17 ± 0.77 vs. 1.72 ± 0.73, p = 0.0001). Similarly, artifacts were reduced with DWIBS (3.16 ± 0.47 vs. 1.76 ± 0.59, p < 0.0001; 3.0 ± 0.73 vs. 2.04 ± 0.53, p = 0.0001). Quantitative analysis showed higher STB with DWIBS (3.26 ± 1.83 vs. 0.98 ± 0.44, p < 0.0001; 3.56 ±, 2.09 vs. 0.92 ± 0.59, p < 0.0001). Gating did not improve image quality and STB on DWIBS (p > 0.05).Conclusion
In thoracic MRI, ungated DWIBS sequence improves fat-sat homogeneity, reduces motion artifacts and increases STB of lymph nodes. Respiratory gating does not improve DWIBS image quality. 相似文献5.
Carballido-Gamio J Xu D Newitt D Han ET Vigneron DB Majumdar S 《Magnetic resonance imaging》2007,25(5):665-670
Diffusion tensor imaging (DTI) of the lumbar spine could improve diagnostic specificity. The purpose of this work was to determine the feasibility of and to validate DTI with single-shot fast spin-echo (SSFSE) for lumbar intervertebral discs at 1.5 and 3 T. Six normal volunteers were scanned with DTI-SSFSE using an eight- and a three-b-value protocol at 1.5 and 3 T, respectively. Apparent diffusion coefficient (ADC) values were computed and validated based on those obtained at 1.5 T from corresponding diffusion tensor scans using line scan diffusion imaging (LSDI), a technique that has been previously validated for use in the spine. Pearson correlation coefficients for LSDI and DTI-SSFSE ADC values were .88 and .89 for 1.5 and 3 T, respectively, with good quantitative agreement according to the Bland-Altman method. Results indicate that DTI-SSFSE is a candidate as a clinical sequence for obtaining diffusion tensor images of the lumbar intervertebral discs with scan times shorter than 4 min. 相似文献
6.
The objective of this study was to implement a clinically relevant multi-slice multi-echo imaging sequence in order to quantify multi-component T2 relaxation times for normal volunteers at both 1.5 and 3 T. Multi-echo data were fitted using a nonnegative least square algorithm. Twelve echo data with nonlinear echo sampling were acquired using a receive-only eight-channel phased array coil and volume head coil for phantoms and normal volunteers, and compared to 32-echo data with linear echo sampling. It was observed that the performance of the 180 degrees refocusing trains was more spatially uniform for the receive-only eight-channel phased array coil than for the head coil, particularly at 3 T. The phantom study showed that the estimated T2 relaxation times were accurate and reproducible for both single- and multi-slice acquisition from a commercial phantom with known T2 relaxation times. Short T2 components (T2 <50 ms) were mainly observed within the white matter for normal volunteers, and the fraction of short T2 water components (i.e., myelin water) was 7-12% of total water. It was observed that the calculated myelin water fraction map from the nonlinearly sampled 12-echo data was comparable with that from the linearly sampled 32-echo data. Quantification of T2 relaxation times from multi-slice images was accomplished with a clinically acceptable scan times (16 min) for normal volunteers by using a nonselective T2 prep imaging sequence. The use of the eight-channel head coil involved more accurate quantification of T2 relaxation times particularly when the number of echoes was limited. 相似文献
7.
A comparative study of myo-inositol quantification using LCmodel at 1.5 T and 3.0 T with 3 D 1H proton spectroscopic imaging of the human brain 总被引:2,自引:0,他引:2
Myo-inositol is a strongly coupled system and resonates at four chemical shift positions. At 1.5 T, only the singlet component at 3.57 ppm is detected. However, at 3 T this resonance is resolved into its components at 3.55 ppm and 3.61 ppm. Due to the increased spectral resolution and signal-to-noise ratio, it is anticipated that the quantification of myo-inositol should improve at 3 T. Using data from normal controls and the LCmodel quantification procedure, we found that the quantification precision, reproducibility and detection sensitivity of myo-inositol is significantly better at 3 T relative to 1.5 T. 相似文献
8.
BackgroundDiffusion MRI (dMRI) data acquisition protocols are well-established on modern high-field clinical scanners for human studies. However, these protocols are not suitable for the chimpanzee (or other large-brained mammals) because of its substantial difference in head geometry and brain volume compared with humans. Therefore, an optimal dMRI data acquisition protocol dedicated to chimpanzee neuroimaging is needed.MethodsA multi-shot (4 segments) double spin-echo echo-planar imaging (MS-EPI) sequence and a single-shot double spin-echo EPI (SS-EPI) sequence were optimized separately for in vivo dMRI data acquisition of chimpanzees using a clinical 3T scanner. Correction for severe susceptibility-induced image distortion and signal drop-off of the chimpanzee brain was performed and evaluated using FSL software. DTI indices in different brain regions and probabilistic tractography were compared. A separate DTI data set from n=34 chimpanzees (13 to 56 years old) was collected using the optimal protocol. Age-related changes in diffusivity indices of optic nerve fibers were evaluated.ResultsThe SS-EPI sequence acquired dMRI data of the chimpanzee brain with approximately doubled the SNR as the MS-EPI sequence given the same scan time. The quality of white matter fiber tracking from the SS-EPI data was much higher than that from MS-EPI data. However, quantitative analysis of DTI indices showed no difference in most ROIs between the SS-EPI and MS-EPI sequences. The progressive evolution of diffusivity indices of optic nerves indicated mild changes in fiber bundles of chimpanzees aged 40 years and above.ConclusionThe single-shot EPI-based acquisition protocol provided better image quality of dMRI for chimpanzee brains and is recommended for in vivo dMRI study or clinical diagnosis of chimpanzees (or other large animals) using a clinical scanner. Also, the tendency of FA decrease or diffusivity increase in the optic nerve of aged chimpanzees was seen but did not show significant age-related changes, suggesting aging may have less impact on optic nerve fiber integrity of chimpanzees, in contrast to previous results for both macaque monkeys and humans. 相似文献
9.
Choi S Cunningham DT Aguila F Corrigan JD Bogner J Mysiw WJ Knopp MV Schmalbrock P 《Magnetic resonance imaging》2011,29(6):739-751
Diffusion tensor imaging (DTI) and advanced related methods such as diffusion spectrum and kurtosis imaging are limited by low signal-to-noise ratio (SNR) at conventional field strengths. DTI at 7 T can provide increased SNR; however, B0 and B1 inhomogeneity and shorter T2? still pose formidable challenges. The purpose of this study was to quantify and compare SNR at 7 and 3 T for different parallel imaging reduction factors, R, and TE, and to evaluate SNRs influences on fractional anisotropy (FA) and apparent diffusion coefficient (ADC). We found that R>4 at 7 T and R≥2 at 3 T were needed to reduce geometric distortions due to B0 inhomogeneity. For these R at 7 T, SNR was 70-90 for b=0 s/mm2 and 22-28 for b=1000s/mm2 in central brain regions. SNR was lower at 3 T (40 for b=0 s/mm2 and 15 for b=1000 s/mm2) and in lateral brain regions at 7 T due to B1 inhomogeneity. FA and ADC did not change with MRI field strength, SENSE factor or TE in the tested range. However, the coefficient of variation for FA increased for SNR <15 and for SNR <10 in ADC, consistent with published theoretical studies. Our study demonstrates that 7 T is advantageous for DTI and lays the groundwork for further development. Foremost, future work should further address challenges with B0 and B1 inhomogeneity to take full advantage for the increased SNR at 7 T. 相似文献
10.
Anna C. Stamm Chadwick L. Wright Michael V. Knopp Petra Schmalbrock Johannes T. Heverhagen 《Magnetic resonance imaging》2013
Purpose
Time-of-flight (ToF) and phase contrast (PC) magnetic resonance angiographies (MRAs) are noninvasive applications to depict the cerebral arteries. Both approaches can image the cerebral vasculature without the administration of intravenous contrast. Therefore, it is used in routine clinical evaluation of cerebrovascular diseases, e.g., aneurysm and arteriovenous malformations. However, subtle microvascular disease usually cannot be resolved with standard, clinical-field-strength MRA. The purpose of this study was to compare the ability of ToF and PC MRA to visualize the cerebral arteries at increasing field strengths.Materials and Methods
The Institutional Review Board-approved study included eight healthy volunteers (age: 36±10 years; three female, five male). All subjects provided written informed consent. ToF and PC MRAs were obtained at 1.5, 3 and 7 T. Signal intensities of the large, primary vessels of the Circle of Willis were measured, and signal-to-noise ratios were calculated. Visualization of smaller first- and second-order branch arteries of the Circle of Willis was also evaluated.Results
The results show that both ToF and PC MRAs allow the depiction of the large primary vessels of the Circle of Willis at all field strengths. Ultrahigh field (7 T) provides only small increases in the signal-to-noise ratio in these primary vessels due to the smaller voxel size acquired. However, ultrahigh-field MRA provides better visualization of the first- and second-order branch arteries with both ToF and PC approaches. Therefore, ultrahigh-field MRA may become an important tool in future neuroradiology research and clinical care. 相似文献11.
In this study the possible adverse effects of in utero exposure to magnetic resonance (MR) conditions at 1.5 Tesla were examined. Thirty-five children between 1 and 3 years of age, and nine children between 8 and 9 years of age, that were exposed to MR during the third trimester of pregnancy, were checked for possible adverse effects in a follow-up study. Data on pregnancy and birth, the results of a neurological examination at 3 months, their medical documentary with emphasis on eye and ear functioning, and a questionnaire answered by their mothers were collected and evaluated. In five children abnormal test results were observed, that had no relation to the MR exposure. No harmful effects of prenatal MR exposure in the third trimester of pregnancy were detected in this study. 相似文献
12.
Magnetic resonance spectroscopy (MRS) has long been considered the golden standard for non-invasive measurement of tissue fat content. With improved techniques for fat/water separation, imaging has become an alternative to MRS for fat quantification. Several imaging models have been proposed, but their performance relative to MRS at very low fat contents is yet not fully established. In this work, imaging and spectroscopy were compared at 1.5 T and 3 T in phantoms with 0-3% fat fraction (FF). We propose a multispectral model with individual a priori R2 relaxation rates for water and fat, and a common unknown R2′ relaxation. Magnitude and complex image reconstructions were also compared. Best accuracy was obtained with the imaging method at 1.5 T. At 3 T, the FFs were underestimated due to larger fat-water phase shifts. Agreement between measured and true FF was excellent for the imaging method at 1.5 T (imaging: FFmeas= 0.98 FFtrue− 0.01%, spectroscopy: FFmeas= 0.77 FFtrue+ 0.08%), and fair at 3 T (imaging: FFmeas= 0.91 FFtrue− 0.19%, spectroscopy: FFmeas= 0.79 FFtrue+ 0.02%). The imaging method was able to quantify FFs down to approx. 0.5%. We conclude that the suggested imaging model is capable of fat quantification with accuracy and precision similar to or better than spectroscopy and offers an improvement vs. a model with a common R2* relaxation only. 相似文献
13.
Technical evaluation of in vivo abdominal fat and IMCL quantification using MRI and MRSI at 3 T 总被引:1,自引:0,他引:1
Li X Youngren JF Hyun B Sakkas GK Mulligan K Majumdar S Masharani UB Schambelan M Goldfine ID 《Magnetic resonance imaging》2008,26(2):188-197
OBJECTIVES: The objectives of this study were to develop protocols that measure abdominal fat and calf muscle lipids with magnetic resonance imaging (MRI) and magnetic resonance spectroscopy (MRS), respectively, at 3 T and to examine the correlation between these parameters and insulin sensitivity. MATERIALS AND METHODS: Ten nondiabetic subjects [five insulin-sensitive (IS) subjects and five insulin-resistant (IR) subjects] were scanned at 3 T. Visceral adipose tissue (VAT) and subcutaneous adipose tissue (SAT) were segmented semiautomatically from abdominal imaging. Intramyocellular lipids (IMCL) in calf muscles were quantified with single-voxel MRS in both soleus and tibialis anterior muscles and with magnetic resonance spectroscopic imaging (MRSI). RESULTS: The average coefficient of variation (CV) of VAT/(VAT+SAT) was 5.2%. The interoperator CV was 1.1% and 5.3% for SAT and VAT estimates, respectively. The CV of IMCL was 13.7% in soleus, 11.9% in tibialis anterior and 2.9% with MRSI. IMCL based on MRSI (3.8+/-1.2%) were significantly inversely correlated with glucose disposal rate, as measured by a hyperinsulinemic-euglycemic clamp. VAT volume correlated significantly with IMCL. IMCL based on MRSI for IR subjects was significantly greater than that for IS subjects (4.5+/-0.9% vs. 2.8+/-0.5%, P=.02). CONCLUSION: MRI and MRS techniques provide a robust noninvasive measurement of abdominal fat and muscle IMCL, which are correlated with insulin action in humans. 相似文献
14.
Do Van Truong Nguyen Tuan Hung Takahiro Shimada Takayuki Kitamura 《Surface science》2012,606(15-16):1331-1339
Ferroelectric thin film with the perovskite ABO3 structure have been widely used in technology applications, e.g., actuators in MEMS/NEMS and nonvolatile random access memories (FeRAM). In order to clarify the effect of the shear strain on the ferroelectricity, the PbTiO3 thin film as a typical one is chosen. The focus of this study is to put on the PbO-terminated (1? × ?1) and c(2? × ?2) surfaces and the TiO2-terminated (1? × ?1) surface. Based on ab initio density functional theory calculations with the local density approximation, we have found out that in both the PbO and TiO2-terminated (1? × ?1) models, the ferroelectricity in the PbO layers was enhanced under the positive shear strain while it was suppressed under the negative one. For the TiO2 layers, the ferroelectricity was slightly enhanced and sharply suppressed under the positive and negative shear strains, respectively. In the PbO-terminated (2? × ?2) model, the AFE phase was suppressed by the FE phase under the positive shear strain while the opposite trend was found under the negative shear strain. For the PbO layers, the ferroelectricity was enhanced under the positive and negative shear strains. For the TiO2 layers, the influence of the negative shear strain on the ferroelectricity was larger than that of the positive one. In addition, the ideal strength of the PbTiO3 thin film with the different terminations was investigated as well. 相似文献
15.
16.
Bhidayasiri R Bronstein JM Sinha S Krahl SE Ahn S Behnke EJ Cohen MS Frysinger R Shellock FG 《Magnetic resonance imaging》2005,23(4):549-555
Deep brain stimulation (DBS) is used increasingly in the field of movement disorders. The implanted electrodes create not only a prior risk to patient safety during MRI, but also a unique opportunity in the collection of functional MRI data conditioned by direct neural stimulation. We evaluated MRI-related heating for bilateral neurostimulation systems used for DBS with an emphasis on assessing clinically relevant imaging parameters. Magnetic resonance imaging was performed using transmit body radiofrequency (RF) coil and receive-only head RF coil at various specific absorption rates (SARs) of RF power. In vitro testing was performed using a gel-filled phantom with temperatures recorded at the electrode tips. Each DBS electrode was positioned with a single extension loop around each pulse generator and a single loop at the "head" end of the phantom. Various pulse sequences were used for MRI including fast spin-echo, echo-planar imaging, magnetization transfer contrast and gradient-echo techniques. The MRI sequences had calculated whole-body averaged SARs and local head SARs ranging from 0.1 to 1.6 W/kg and 0.1 to 3.2 W/kg, respectively. Temperature elevations of less than 1.0 degrees C were found with the fast spin-echo, magnetization transfer contrast, gradient-echo and echo-planar clinical imaging sequences. Using the highest SAR levels, whole-body averaged, 1.6 W/kg, local exposed-body, 3.2 W/kg, and local head, 2.9 W/kg, the temperature increase was 2.1 degrees C. These results showed that temperature elevations associated with clinical sequences were within an acceptable physiologically safe range for the MR conditions used in this evaluation, especially for the use of relatively low SAR levels. Notably, these findings are highly specific to the neurostimulation systems, device positioning technique, MR system and imaging conditions used in this investigation. 相似文献
17.
The 300 MHz (7 T) water proton resonances of suspensions of red blood cells containing paramagnetic deoxyhemoglobin or methemoglobin can be resolved into two broad lines assignable to intra- and extracellular water which undergoes rapid T2 relaxation by diffusion in magnetic field gradients induced by the intracellular paramagnets. The width of the resolved lines allowed an estimate of the maximum contribution that diffusion makes to T2 relaxation at 7 T. The dependence of the diffusion contribution on the square of the strength of the static magnetic field suggest that diffusion makes a small contribution to water proton T2 relaxation at 1.5 T compared to 7 T, and a negligible one at 0.5 T in early and intermediate hematomas containing deoxyhemoglobin or methemoglobin in intact red blood cells. At the lower field strengths, water proton T2 relaxation is apparently dominated by the rapid chemical exchange (mean lifetime tau = 10 msec) between the intra- and extracellular environments. 相似文献
18.
The interleaved-spiral magnetic resonance imaging (MRI) technique was implemented and optimized on a Bruker Biospec 47/30
scanner. The method gives rise to high-resolution images with a time saving factor of up to 8, as compared to the conventional
approach. A multifunctional pulse sequence for the fast interleaved-spiral MRI was composed. These functions include spin
intensity imaging, transverse relaxation timeT
2 and apparent diffusion-weighted imaging. The method was used to obtain the dynamic responses of a rat brain during ischemia. 相似文献
19.
20.
The Raman line shapes of the ν1(A 1)C-H and C-D stretching fundamentals in liquid CHCl3 and CDCl3 have been measured as a function of pressure from 1 bar to 4·5 kbar within the temperature range 30°C to 90°C. Densities have also been determined under the same experimental conditions. The vibrational relaxation rates are obtained from the isotropic component of the Raman band and the experimental results can be summarized as follows: (i) as T increases at constant density the vibrational relaxation rate increases; (ii) at constant T, the increase in density produces an increase in the relaxation rate; (iii) an increase in temperature at constant pressure results in an increased relaxation rate. The above three cases hold for the CDCl3 liquid, whereas only (ii) may be stated for the CHCl3 liquid. The experimental vibrational data are interpreted in terms of the Kubo stochastic line-shape theory and the collinear-isolated-binary-collision model proposed by Fischer and Laubereau. Application of the Kubo formalism shows that vibrational dephasing is the dominant relaxation mechanism and that the modulation is fast both in liquid CHCl3 and CDCl3. Interpretation in terms of the binary collision dephasing model leads to the following results: (i) the pure dephasing mechanism seems to be the dominant broadening mechanism for the isotropic Raman line shapes studied; (ii) the calculated dephasing rates as a function of density and temperature show agreement with the experimental data. In these calculations the elastic collision times are obtained from the modified Enskog theory. 相似文献