首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
The identification and structure elucidation of drug metabolites is one of the main objectives in in vitro ADME studies. Typical modern methodologies involve incubation of the drug with subcellular fractions to simulate metabolism followed by LC-MS/MS or LC-MS(n) analysis and chemometric approaches for the extraction of the metabolites. The objective of this work was the software-guided identification and structure elucidation of major and minor buspirone metabolites using capillary LC as a separation technique and ion trap MS(n) as well as electrospray ionization orthogonal acceleration time-of-flight (ESI oaTOF) mass spectrometry as detection techniques.Buspirone mainly underwent hydroxylation, dihydroxylation and N-oxidation in S9 fractions in the presence of phase I co-factors and the corresponding glucuronides were detected in the presence of phase II co-factors. The use of automated ion trap MS/MS data-dependent acquisition combined with a chemometric tool allowed the detection of five small chromatographic peaks of unexpected metabolites that co-eluted with the larger chromatographic peaks of expected metabolites. Using automatic assignment of ion trap MS/MS fragments as well as accurate mass measurements from an ESI oaTOF mass spectrometer, possible structures were postulated for these metabolites that were previously not reported in the literature.  相似文献   

2.
A novel LC/MS/MS method that uses multiple ion monitoring (MIM) as a survey scan to trigger the acquisition of enhanced product ions (EPI) on a hybrid quadrupole-linear ion trap mass spectrometer (Q TRAP) was developed for drug metabolite identification. In the MIM experiment, multiple predicted metabolite ions were monitored in both Q1 and Q3. The collision energy in Q2 was set to a low value to minimize fragmentation. Results from analyzing ritonavir metabolites in rat hepatocytes demonstrate that MIM-EPI was capable of targeting a larger number of metabolites regardless of their fragmentation and retained sensitivity and duty cycle similar to multiple reaction monitoring (MRM)-EPI. MIM-based scanning methods were shown to be particularly useful in several applications. First, MIM-EPI enabled the sensitive detection and MS/MS acquisition of up to 100 predicted metabolites. Second, MIM-MRM-EPI was better than MRM-EPI in the analysis of metabolites that undergo either predictable or unpredictable fragmentation pathways. Finally, a combination of MIM-EPI and full-scan MS (EMS), as an alternative to EMS-EPI, was well suited for routine in vitro metabolite profiling. Overall, MIM-EPI significantly enhanced the metabolite identification capability of the hybrid triple quadrupole-linear ion trap LC/MS.  相似文献   

3.
Yang X  Li P  Zhao Y  Wu Y 《色谱》2012,30(3):309-313
建立了花生中涕灭威及其代谢物涕灭威砜、涕灭威亚砜的高效液相色谱-线性离子阱三级质谱分析方法。样品经环己烷饱和的乙腈提取,凝胶渗透色谱净化后,用高效液相色谱-线性离子阱三级质谱法对样品中的目标物进行定性确证和定量分析。在Capcell PAK CR色谱柱上以含5 mmol/L NH4Ac-HAc的乙腈为流动相进行梯度洗脱分离。采用电喷雾离子源正离子模式进行三级选择离子监测,以涕灭威-d3作为3个目标物的内标物。通过比较基质匹配曲线和纯溶剂标准曲线计算回收率评估基质效应。方法的线性范围为10~500 μg/L,检出限为4~5 μg/kg。涕灭威、涕灭威砜、涕灭威亚砜在3个加标水平(10、20、40 μg/kg)的回收率为81.5%~115%,相对标准偏差为6.35%~15.1%。应用该方法对花生样品进行了测定,结果令人满意。  相似文献   

4.
The application of a new hybrid RF/DC quadrupole-linear ion trap mass spectrometer to support drug metabolism and pharmacokinetic studies is described. The instrument is based on a quadrupole ion path and is capable of conventional tandem mass spectrometry (MS/MS) as well as several high-sensitivity ion trap MS scans using the final quadrupole as a linear ion trap. Several pharmaceutical compounds, including trocade, remikiren and tolcapone, were used to evaluate the capabilities of the system with positive and negative turbo ionspray, using either information-dependent data acquisition (IDA) or targeted analysis for the screening, identification and quantification of metabolites. Owing to the MS/MS in-space configuration, quadrupole-like CID spectra with ion trap sensitivity can be obtained without the classical low mass cutoff of 3D ion traps. The system also has MS(3) capability which allows fragmentation cascades to be followed. The combination of constant neutral loss or precursor ion scan with the enhanced product ion scan was found to be very selective for identifying metabolites at the picogram level in very complex matrices. Owing to the very high cycle time and, depending on the mass range, up to eight different MS experiments could be performed simultaneously without compromising chromatographic performance. Targeted product ion analysis was found to be complementary to IDA, in particular for very low concentrations. Comparable sensitivity was found in enhanced product ion scan and selected reaction monitoring modes. The instrument is particularly suitable for both qualitative and quantitative analysis.  相似文献   

5.
A method for simultaneous determination of 10 first-generation histamine H1 receptor blockers in feeds by ultra-high-performance liquid chromatography triple quadrupole mass spectrometry combined with solid phase extraction. Instrument conditions, extraction solvents, and purification methods have been optimized. Under the optimum conditions, these analytes were separated effectively at 6 min. These feeds have been extracted by acid acetonitrile and purified by mixed cation exchange solid-phase extraction. The performance of this method meets the requirements of veterinary residue detection in feeds in China. It is appropriate for the confirmatory monitoring and quantitative analysis of 105 feed samples, five kinds of histamine H1 receptor blockers have been detected in 10 samples.  相似文献   

6.
Imatinib (Gleevec) is an anticancer drug that inhibits specific protein kinases involved in cell proliferation. Whereas this drug is considered to have opened a new era, various mechanisms of resistance have been associated with imatinib relapse. Drug disposition in cancer cells including influx, efflux and drug metabolism is one mechanism that remains to be more thoroughly investigated. Moreover, recent genomic studies have revealed that some isozymes of cytochrome P450 (CYP) are possibly associated with the treatment outcome. Therefore, this research paper investigates the role of the activity of CYP1A1, 1A2, 1B1, 3A4, 4F2 and 4F3A/B on the fate of imatinib. First, a study of imatinib fragmentation was effected using electrospray triple-quadrupole and linear ion trap tandem mass spectrometers (MSn). Accurate mass determinations were performed at enhanced mass resolution for the identification of some product ions that were not predicted by two fragmentation softwares. Whereas the quadrupole MS was not designed for accurate mass measurement, delta mass errors were below 20 ppm. Then, a biotransformation study was effected in vitro. Imatinib metabolites were produced in microsomal incubations containing CYP isozymes. Imatinib and metabolites were extracted from incubation mixtures by protein precipitation, and supernatants were injected into a liquid chromatography equipment coupled with MS(n). Hydrophobic interaction liquid chromatography resolved one demethylated-, two hydroxy- and three N-oxide metabolites. Various rates of metabolite formation were observed between CYP isozymes. Liquid chromatography with deuterium oxide-containing mobile phase (H/D exchange) or incorporation of (18)O from H(2) (18)O added in the incubations was performed to elucidate the metabolite structure. Various MS(n) product scans (n < or = 4) were acquired on the linear ion trap or on the triple-quadrupole MS. Postulated structures of new metabolites are addressed.  相似文献   

7.
Liquid secondary ion mass spectrometry (L-SIMS) of six new functionalized macrocycles was investigated. All six compounds yielded abundant fragment ions and protonation molecular ions [M + H](+) under L-SIMS conditions. The proposed fragmentation mechanisms were supported by high-resolution accurate mass data from Fourier transform ion cyclotron resonance mass spectrometric and MS(n) experiments on using sustained off-resonance irradiation collision-induced dissociation.  相似文献   

8.
Triple-stage quadrupole (TSQ) electrospray ionization (ESI) tandem mass spectrometry (MS/MS) and ion trap ESI-MS/MS can be used to cleave protonated molecules to produce carbocations and neutral molecules in the positive ion mode. Dissociation products which correspond to protonated forms of neutral fragment molecules can also be trapped and detected. These protonated molecules in turn can cleave via carbocation cleavage, ipso cleavage, onium cleavage or McLafferty or related rearrangements. One can elucidate the structures of metabolites from the differences in m/z ratios of the fragments arising from the original drug compound and its metabolite. This strategy for structural elucidation is further facilitated by estimates of the reactivity of drugs with oxygen diradicals involved in cytochrome P-450 cycles.  相似文献   

9.
During the course of decoction, the components of herbal formula interact with each other, such that chemical extraction characteristics are altered. The crude drugs, Lilium brownii (Baihe) and Rhizoma Anemarrhenae (Zhimu), are the herbal constituents of Baihe Zhimu decoction, a traditional herbal formula. To investigate the chemical interaction between Baihe and Zhimu when decocting together, eight marker components in Baihe Zhimu decoction were simultaneously characterized and quantified in one run by a hybrid triple quadrupole linear ion trap mass spectrometer in the multiple reactions monitoring–information dependent acquisition–enhanced product ion mode. The results showed that Zhimu significantly suppressed the extraction of phenolic glycosides (the components from Baihe) when co‐decocting, and Baihe clearly suppressed the extraction of xanthones and steroidal saponins (the components from Zhimu). Overall, the presently developed method would be a preferred candidate for the investigation of the chemical interaction between herbal medicines.  相似文献   

10.
Ten different samples with 13 previously identified saponin structures from Quillaja saponaria Molina were investigated by electrospray ionization ion trap multiple-stage mass spectrometry (ESI-ITMS(n)) in positive and negative ion modes. Both positive and negative ion mode MS(1)-MS(4) spectra were analyzed, showing that structural information on the two oligosaccharide parts in the saponin can be obtained from positive ion mode spectra whereas negative ion mode spectra mainly gave information on one of the oligosaccharide parts. Analysis of MS(1)-MS(4) spectra identified useful key fragment ions important for the structural elucidation of Quillaja saponins. A flowchart involving a stepwise procedure based on key fragments from MS(1)-MS(3) spectra was constructed for the identification of structural elements in the saponin. Peak intensity ratios in MS(3) spectra were found to be correlated with structural features of the investigated saponins and are therefore of value for the identification of terminal monosaccharide residues.  相似文献   

11.
The aim of the present study was to develop a practical method for the characterization of coumarins in Radix Glehniae by liquid chromatography–mass spectrometry (LC–MS). First, 10 coumarin standards (including two pairs of isomers) were studied, and mass spectrometry fragmentation patterns and elution time rules for the coumarins were found. Then, an extract of Radix Glehniae was analyzed by the combination of two scan modes, i.e., multiple ion monitoring-information-dependent acquisition-enhanced product ion mode (MIM-IDA-EPI) and precursor scan information-dependent acquisition-enhanced product ion mode (PREC-IDA-EPI) on a hybrid triple quadrupole-linear ion trap mass spectrometer. A total of 41 coumarins were identified on the basis of their mass spectrometry fragmentation patterns. This is the first time that these two scan modes have been combined to characterize chemical constituents in traditional Chinese medicine. This new method allowed the identification of coumarins in Radix Glehniae in trace amounts. The methodology proposed in this study could be valuable for the structural characterization of coumarins from complex natural and synthetic sources.  相似文献   

12.
With the recent trend towards mass spectrometer miniaturization, the fabrication of mass analyzers and other ion optical components is being performed at scales where critical dimensions range from several millimeters to several micrometers. Depending on the sizes of the objects and the nature of the fabrication method used, electrode surface roughness can become non‐negligible and affect the analytical performance of the mass analyzer. In this work, a method of characterizing surface roughness is introduced through the concept of spatial roughness frequency. The roughness of a given surface is quantitatively described using spatial roughness components at a series of frequencies and with characteristic intensities. Based on this concept, an analytical method has been developed to describe the electromagnetic field inside an electrode assembly including consideration for the electrode roughness. The methodology is applied in simplified form to cylindrical and rectilinear ion trap analyzers. Four types of surface finishes were applied to ion trap electrodes of various sizes to illustrate the surface roughness effects on the high‐order fields and to compare the analytical performance of the ion traps. Application of this method to arrays of large numbers of micro‐scale ion traps has enabled the impact of fabrication methodology to be evaluated in terms of mass resolution for the ion trap arrays. Copyright © 2008 John Wiley & Sons, Ltd.  相似文献   

13.
The fragmentation of heterocyclic amines (HAs) in an ion trap was studied by means of the infusion of methanolic solutions containing the compounds under assay, and using an atmospheric pressure chemical ionization (APCI) as ion source. The MS(n) spectra obtained for compounds included in the same family, either aminoimidazoazaarenes (AIAs) or carbolines, were compared in order to propose fragmentation pathways for each HA. Moreover, labelled AIAs were used to establish the mechanisms. The protonated molecule was always obtained, but subsequent fragmentation was different for both families. In the case of AIAs, major product ions came from the fragmentation of the aminoimidazole moiety, thus the base peak in MS(2) corresponded to the loss of the methyl group, and losses of C(2)NH(3) and CN(2)H(2) were also observed. Further fragmentation occurred in the heterocyclic rings, mainly with losses of HCN and CH(3)CN. For carbolines, the most important product ions came from the loss of ammonia, except for harman and norharman, the loss of a methyl group for methylated carbolines or the loss of diverse fragments from the heterocyclic rings. In some cases, ion-molecule reactions into the ion trap were observed. For instance, for AalphaC or MeAalphaC one ion originating from these reactions corresponded to the base peak.  相似文献   

14.
从理论上讲, 离子阱质谱仪的性能是由阱内电场分布决定的,而电场分布又是由组成离子阱的电极几何结构和离子阱工作电压决定的. 对于矩形离子阱, 即使不考虑其几何结构的偏差, 其阱内的电场分布一般也很复杂. 在矩形离子阱内, 除四极电场外, 还包含多种成分的其他各种高阶场, 它们直接影响离子在阱内的运动轨迹和离子阱质谱的性能. 由于各种电场成分对离子阱内离子运动的影响非常复杂, 还很难从数学上给出精确的解析解, 使得目前从理论上还无法预测高阶场成分对质谱性能的影响. 本工作通过测定不同几何结构的矩形离子阱的稳定图, 从实验上比较了不同场半径, 即不同电场分布条件下的离子阱质谱性能的差别. 实验中, 通过改变离子阱的几何比例结构, 详细测定了不同结构的矩形离子阱的稳定图特征, 并与实验测得的质谱分析结果进行比较. 同时, 我们还详细介绍了矩形离子阱质谱的稳定图的测定方法, 并根据得到的不同情况下的稳定图结构分析了离子阱的质谱性能. 研究结果表明: 可以通过比较试验得到的稳定图结构来判断其离子阱质谱仪的性能如质量分辨能力等. 此外, 实验结果还发现: 对于y方向拉伸结构的矩形离子阱, 其实验绘制得到的是不完整的稳定图. 但根据稳定图边界的特点, 通过采用四极直流电压调制的方法, 可以对y方向拉伸结构的矩形离子阱的性能进行改善, 极大地提高了阱的质量分辨能力.  相似文献   

15.
Trimethoprim (TMP) and diaveridine (DVD) are used in combination with sulfonamides and sulfaquinoxlaine as an effective antibacterial agent and antiprotozoal agent, respectively, in humans and animals. To gain a better understanding of the metabolism of TMP and DVD in the food-producing animals, the metabolites incubated with liver microsomes of pigs were analyzed for the first time with high-performance liquid chromatography combined with hybrid ion trap/time-of-flight mass spectrometry. Seven TMP-related and six DVD-related metabolites were characterized based on the accurate MS2 spectra and known structure of the parent drug, respectively. The metabolites of TMP were identified as two O-demethylation metabolites, a di-O-demethylation metabolite, two N-oxides metabolites, a hydroxylated metabolite on the methylene carbon and a hydroxylated metabolite on the methyl group. DVD was also biotransformed to two O-demethylation metabolites, a di-O-demethylation metabolite, an N-oxide metabolite, a hydroxylation metabolite on the methylene carbon and a hydroxylation metabolite followed by O-demethylation. The results indicate that the two compounds have similar biotransformation pathways in pigs. O-Demethylation was the major metabolic route of TMP and DVD in the pig liver microsomes. The proposed metabolic pathways of TMP and DVD in liver microsomes will provide a basis for further studies of the in vivo metabolism of the two drugs in food-producing animals.  相似文献   

16.
The fragmentation of fragile ions during the application of an isolation waveform for precursor ion selection and the resulting loss of isolated ion intensity is well‐known in ion trap mass spectrometry (ITMS). To obtain adequate ion intensity in the selected reaction monitoring (SRM) of fragile precursor ions, a wider ion isolation width is required. However, the increased isolation width significantly diminishes the selectivity of the channels chosen for SRM, which is a serious problem for samples with complex matrices. The sensitive and selective quantification of many lipid molecules, including ceramides from real biological samples, using a linear ion trap mass spectrometer is also hindered by the same problem because of the ease of water loss from protonated ceramide ions. In this study, a method for the reliable quantification of ceramides using SRM with near unity precursor ion isolation has been developed for ITMS by utilizing alternative precursor ions generated by in‐source dissociation. The selected precursor ions allow the isolation of ions with unit mass width and the selective analysis of ceramides using SRM with negligible loss of sensitivity. The quantification of C18:0‐, C24:0‐ and C24:1‐ceramides using the present method shows excellent linearity over the concentration ranges from 6 to 100, 25 to 1000 and 25 to 1000 nM, respectively. The limits of detection of C18:0‐, C24:0‐ and C24:1‐ceramides were 0.25, 0.25 and 5 fmol, respectively. The developed method was successfully applied to quantify ceramides in fetal bovine serum. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

17.
Laser-ablation ion trap mass spectrometry (LA-ITMS) is applied for the analysis of rare-earth elements in soil samples. The target elements studied in this work were ytterbium (Yb) and samarium (Sm). The isotopic compositions of these elements were analyzed for standard samples with chip shape, the western phosphate rock sample (NIST SRM-694), and soil samples collected near our laboratory. For metal samples of Sm and Yb, isotopes of these elements as well as oxide forms were clearly identified. For the case of soil samples only a tentative assignment on the mass peaks were performed due to the complicated mass spectra that originated from the oxide forms of various rare-earth elements.  相似文献   

18.
This paper presents the development of a fast multi-residue method for the determination of 49 pharmaceuticals and 6 metabolites from different therapeutic classes in water resources by means of Ultra-performance™ liquid chromatography (UPLC) coupled to tandem mass spectrometry. The use of the UPLC technology enabled all the 55 compounds to be separated chromatographically in less than 9 min (6.3 min positive mode and 2.7 min negative mode) and with a total analysis time of 18 min when considering column conditioning. Improved resolution, sensitivity and a reduction of matrix effects were obtained under these conditions. Unequivocal identification and quantification of the target compounds was also performed by using the dual acquisition modes of the hybrid triple quadrupole-linear ion trap (QqLIT) system. Triple quadrupole mode by means of selected reaction monitoring (SRM) was used for quantification, whilst a second SRM transition together with information-dependent analysis (IDA) experiments was used for confirmation. Additionally, one general, single solid-phase extraction (SPE) method was developed by using Oasis HLB cartridges. Quality parameters of the method in wastewaters were established obtaining a fast, robust, reproducible and cost-effective method for all the target pharmaceuticals. Finally, the optimized SPE-UPLC/QqLIT method was used for the analysis of the target compounds in wastewaters from Spain. Thirty-one out of fifty-five compounds were identified in the samples collected.  相似文献   

19.
A generic and efficient homolog-targeted approach was used to expand screening and detection of target class of sulfonamides and structural analogs, based on a fast single-tube extraction/partitioning-multifunction adsorption cleanup (SEP/MAC) for class-specific fragmentation-dependent acquisition with a liquid chromatography–hybrid triple-quadrupole linear ion trap mass spectrometer (LC–QqLIT). By combining the two-stage process conducted in a single tube as one-pot protocol, the straightforward SEP/MAC procedure was optimized to offer clean extracts with reasonable recovery (71–109% with RSDs < 20%) and decreased matrix interferences (−9 to 19%) of multiresidual sulfonamide extraction from different tissue samples. The novel use of neutral loss scan of 66 Da (NLS) or precursor ion scanning of m/z 108 (PreS) in positive ion mode was found to achieve more comprehensive coverage of protonated molecular ions of a wide array of sulfonamides including N4-acetyl and hydroxylamine metabolites plus their possible dimers. Moreover, the PreS-triggered automatically enhanced product ion spectral acquisition enabled simultaneous screening, profiling and confirmation of an unlimited number of analytes belonging to the sulfonamide class within a single analysis. The validation and application results of the generic SEP/MAC-based LC–QqLIT strategy consistently demonstrated favorable performances with acceptable accuracy (67–116%), precision (RSDs < 25%), and sensitivity (LOQs ≤ 7.5 ng g−1) to meet the acceptance criteria for all the sulfonamide–tissue combinations. Thus, the integration of the matrix-independent SEP/MAC procedure and the multiparameter matching algorithm with the unit-resolution LC–QqLIT instrument can serve as a valuable semi-targeted discovery strategy for rapid screening and reliable quantitative/confirmatory analysis of real samples.  相似文献   

20.
Due to the varying toxicity the species of organotins in their widespread applications, it is important for analytical methods to address their speciation. Traditional methods call for the hydrolysis and subsequent derivatization of the organotins before analysis. These methods can be time‐consuming, derivatization can be incomplete and high levels of background interference produce difficulties in identification and quantification. The use is described of a non‐derivatization and non‐hydrolysis micro‐liquid chromatography–electrospray/ion trap mass spectrometry for separation and detection of the organotins. Copyright © 1999 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号