1.
An emerging trend is recognised in hormone and veterinary drug residue analysis from liquid chromatography tandem mass spectrometry (LC/MS/MS) based screening and confirmation towards accurate mass alternatives such as LC coupled with time-of-flight (TOF), Fourier transform ion cyclotron resonance (FTICR) or Fourier transform orbitrap (FT Orbitrap) MS. In this study, mass resolution and accuracy are discussed for LC/MS screening and confirmation of targeted analytes and for the identification of unknowns using the anabolic steroid stanozolol and the designer beta-agonist "Clenbuterol-R" as model substances. It is shown theoretically and experimentally that mass accuracy criteria without proper mass resolution criteria yield false compliant (false negative) results, both in MS screening and MS/MS confirmation of stanozolol. On the other hand, previous medium resolution accurate mass TOFMS/MS data of the designer beta-agonist were fully confirmed by high resolution FT Orbitrap MS(n) experiments. A discussion is initiated through a proposal for additional criteria for the use of accurate mass LC/MS technologies, to be implemented in Commission Decision 2002/657/EC.  相似文献   

2.
An efficient method was developed for toxicological drug screening in urine by liquid chromatography coupled with electrospray ionization time-of-flight mass spectrometry. The method relies on a large target database of exact monoisotopic masses representing the elemental formulae of reference drugs and their metabolites. Mass spectral identification is based on matching measured accurate mass and isotopic pattern (SigmaFit) of a sample component with those in the database. Data post-processing software was developed for automated reporting of findings in an easily interpretable form. The mean and median of SigmaFit for true-positive findings were 0.0066 and 0.0051, respectively. The mean and median of mass error absolute values for true-positive findings were 2.51 and 2.17 ppm, respectively, corresponding to 0.65 and 0.60 mTh. For routine screening practice, a SigmaFit tolerance of 0.03 and a mass tolerance of 10 ppm were chosen. Ion abundance differences from urine extracts did not affect the accuracy of the automatically acquired SigmaFit or mass values. The results show that isotopic pattern matching by SigmaFit is a powerful means of identification in addition to accurate mass measurement.  相似文献   

3.
The last 2 years multi-compound methods are gaining ground as screening methods. In this study a high-resolution liquid chromatography combined with time-of-flight mass spectrometry (HRLC–ToF-MS) is tested for the screening of about 100 veterinary drugs in three matrices, meat, fish and egg. While the results are satisfactory for 70–90% of the veterinary drugs, a more efficient sample preparation or extract purification is required for quantitative analysis of all analytes in more difficult matrices like egg. The average mass measurement error of the ToF-MS for the veterinary drugs spiked at concentrations ranging from 4 to 400 μg/kg, is 3.0 ppm (median 2.5 ppm) with little difference between the three matrices, but slightly decreases with increasing concentration. The SigmaFit value, a new feature for isotope pattern matching, also decreases with increasing concentration and, in addition, shows an increase with increasing matrix complexity. While the average SigmaFit value is 0.04, the median is 0.01 indicating some high individual deviations. As with the mass measurement error, the highest deviations are found in those regions of the chromatogram where most compounds elute from the column, be it analytes or matrix compounds. The median repeatability of the method ranges from 8% to 15%, decreasing with increasing concentration, while the median reproducibility ranges from 15% to 20% with little difference between matrices and concentrations. The median accuracy is in between 70% and 100% with a few compounds showing higher values due to matrix interference. The squared regression coefficient is >0.99 for 92% of the compounds showing a good overall linearity for most compounds. The detection capability, CCβ, is within 2 times the associated validation level for >90% of the compounds studied. By changing a few conditions in the analyses protocol and analysing a number of blank samples, it was determined that the method is robust as well as specific. Finally, an alternative validation strategy is proposed and tested for screening methods. While the results calculated for repeatability, within-lab reproducibility and CCβ show a good comparison for the matrices meat and fish, and a reasonable comparison for the matrix egg, only 27 analyses are required to obtain these results versus 63 analysis in the traditional, 2002/657/EC, approach. This alternative is suggested as a cost-effective validation procedure for screening methods.  相似文献   

4.
Analysis of the major drugs of abuse in meconium has been established in clinical practice for detecting fetal exposure to illicit drugs, particularly for the ready availability of the sample and ease of collection from diapers, compared with neonatal hair and urine. Very little is known about the occurrence and detection possibilities of therapeutic and licit drugs in meconium. Meconium specimens (n = 209) were collected in delivery hospitals, from infants of mothers who were suspected to be drug abusers. A targeted analysis method by liquid chromatography–triple quadrupole mass spectrometry (LC-MS/MS) was developed for abused drugs: amphetamine, methamphetamine, 3,4-methylenedioxyamphetamine, 3,4-methylenedioxymethamphetamine, morphine, codeine, 6-monoacetylmorphine, oxycodone, methadone, tramadol, buprenorphine, and norbuprenorphine. A separate LC-MS/MS method was developed for 11-nor-∆9-tetrahydrocannabinol-9-carboxylic acid. A screening method based on LC coupled to time-of-flight MS was applied to a broad spectrum of drugs. As a result, a total of 77 different compounds were found. The main drug findings in meconium were as follows: local anesthetics 82.5% (n = 172), nicotine or its metabolites 61.5% (n = 129), opioids 48.5% (n = 101), stimulants 21.0% (n = 44), hypnotics and sedatives 19.0% (n = 40), antidepressants 18.0% (n = 38), antipsychotics 5.5% (n = 11), and cannabis 3.0% (n = 5). By revealing drugs and metabolites beyond the ordinary scope, the present procedure helps the pediatrician in cases where maternal denial is strong but the infant seems to suffer from typical drug-withdrawal symptoms. Intrapartum drug administration cannot be differentiated from gestational drug use by meconium analysis, which affects the interpretation of oxycodone, tramadol, fentanyl, pethidine, and ephedrine findings.  相似文献   

5.
张洁  严丽娟  潘晨松  林立毅  张欣怡  申河清 《色谱》2012,30(10):1031-1036
利用超高效液相色谱/高分辨飞行时间质谱结合数据库建立了乳制品中19种抗生素的分析方法。样品依次经过乙腈和酸化乙腈处理后,冷冻离心浓缩,经超高效液相色谱分离,正离子扫描模式下,在10 min内对19种抗生素进行分离和检测,质量浓度在10~500或15~1000 μg/L范围内具有良好的线性关系,检出限为3~5 μg/L,平均回收率为68.4%~96.7%。加标样品的筛查结果表明,保留时间偏差不大于0.1 min,质量偏差小于5 mDa,同位素峰形匹配度不低于87.4%, 19种加标抗生素被全部检测出来,且大部分抗生素获得很高的鉴定评分。对购自本地超市的40余份乳制品进行了筛查分析,未检出阳性样品。该分析方法具有前处理简单、分析速度快、灵敏度高、质量精确度高的特点,可应用于乳制品中抗生素的快速筛查。  相似文献   

6.
Glutathione S-transferases (GSTs) isolated from maize were used to catalyze the conjugation of glutathione (GSH) with chloroacetanilide herbicides, producing stable conjugates that were structurally characterized using ultra-performance liquid chromatography/quadrupole time-of-flight mass spectrometry (UPLC/QqToF-MS) and liquid chromatography/ion trap mass spectrometry (LC/IT-MS). Enzyme-mediated dechlorination of alachlor, metolachlor, and propachlor resulted during GSH conjugation as revealed by the mass spectra of the conjugates, which was confirmed by the loss of the chlorine isotopic signature and from high accurate mass measurements. Several fragmentation patterns in the mass spectra of the chloroacetanilide-GSH conjugates can be used to verify the identities of the enzyme reaction products, such as characteristic ions corresponding to the neutral loss of glutamic acid residue (129 Da) and water (18 Da) observed in the product ion spectrum. For the first time, data are presented showing detection of chloroacetanilides that are conjugated with two GSH molecules, in addition to the known single GSH conjugates.  相似文献   

7.
A new method based on ultra-performance liquid chromatography (UPLC) quadrupole time-of-flight mass spectrometry ((Q-ToF)-MS) was developed for the analysis of 32 biologically active compounds including anti-inflammatories, analgesics, lipid regulators, psychiatric drugs, anti-ulcer agents, antibiotics, beta-blockers and phytoestrogens. This new method allows chromatographic analysis in 14 min, with instrumental detection limits from 2 to 84 pg, and limits of quantification ranging from 0.1 to 15 ng/L in tap water, and from 2 to 300 ng/L in wastewater. The potential of liquid chromatography with triple quadrupole mass spectrometry (LC/QqQ-MS) was compared with that of UPLC/(Q-ToF)-MS for the analysis of biologically active compounds in water samples. LC/Q-ToF provides accurate mass information and a significantly higher mass resolution than quadrupole analyzers. The available mass resolution of ToF instruments diminishes the problem of isobaric interferences and helps the analysis of trace compounds in complex samples. In this work UPLC/Q-ToF chromatograms were recorded containing full scan spectral data. The m/z values of analytes were extracted from the total ion chromatogram (TIC) and the accurate masses of the compounds were obtained. In addition, to increase the selectivity of ToF measurements a narrow accurate mass interval (20 m m/z units mass window) was used to reconstruct the chromatographic traces. However, regarding quantitative performance in terms of dynamic range and limits of detection (LODs), typical LODs achieved by QqQ instruments operating in multiple-reaction monitoring (MRM) mode ranged from 1 to 50 ng/L in wastewater, and the linear response for QqQ instruments generally covers three orders of magnitude. This is an important advantage over ToF instruments and one of the reasons why QqQ instruments are widely used in quantitative environmental analysis.  相似文献   

8.
Geniposide, an iridoid glycoside, is an important and characteristic compound in the fruits of Gardenia jasminoides Ellis, a commonly used medicinal herb in Chinese traditional and folk medicine for the treatment of inflammation and jaundice. However, few studies have been carried out on the metabolism of geniposide. In this study, we have established a rapid and sensitive method using ultra‐performance liquid chromatography coupled with electrospray ionization quadrupole time‐of‐flight tandem mass spectrometry (UPLC/ESI‐QTOF‐MS) for analysis of the metabolic profile of geniposide in rat urine after oral administration. A total of ten metabolites were detected and identified by comparing their fragmentation patterns with that of geniposide using Metabolynx? and MassFragment? software tools. The results revealed that the principal metabolism pathways of geniposide in rat occurred after deglycosylation of the irdoid glycoside take place and this is followed by glucuronidation and the pyran‐ring cleavages. The major metabolite, the glucuronic acid conjugate of genipin as observed in vivo, was further confirmed by the in vitro enzymatic study. The results of this work have demonstrated the feasibility of the UPLC/ESI‐QTOF‐MS approach for rapid and reliable characterization of metabolites from iridoid compounds. Copyright © 2011 John Wiley & Sons, Ltd.  相似文献   

9.
Findings of illegal hormone preparations such as syringes, bottles, cocktails, and so on, are an important information source for the nature of the current abuse of anabolic steroids and related compounds as growth-promoting agents in cattle. A new screening method for steroids in cocktails is presented based on liquid chromatography (LC) with diode-array UV-absorbance detection and electrospray ionization time-of-flight mass spectrometry (ESI-TOFMS). Accurate mass measurements were performed at a mass resolution of 4000 using continuous introduction of a lock mass through a second (electro)sprayer. Similar experiments were carried out using dual-sprayer quadrupole time-of-flight mass spectrometry (ESI-QTOFMS/MS) at a mass resolution of 10 000 with data-dependent MS/MS acquisition; i.e. beyond an intensity threshold for the [M + H](+) ions, MS/MS spectra were automatically acquired at three different collision energies. Elemental compositions were calculated for precursor and product ions and it is shown that the combined information from LC retention behavior, UV spectra, elemental compositions, and accurate mass MS/MS spectra yield a fast impression of the steroids present in the complex mixture. Using a new software tool for structure elucidation of MS/MS spectra, an additional non-steroidal additive was identified as well.  相似文献   

10.
The resolution of asparagine-linked oligosaccharides in glycopeptides was carried out by combination of the transglycosylation reaction and ultra-performance liquid chromatography with electrospray ionization time-of-flight mass spectrometry (UPLC-ESI-TOF-MS). The resolution of the oligosaccharides is based on the enzymic transglycosylation reaction with Endo-beta-N-acetylglucosaminidase (Endo-M) isolated from Mucor hiemalis. The oligosaccharides were transferred to a fluorescent acceptor (NDA-Asn-GlcNAc) with Endo-M to produce the fluorescent oligosaccharides. In the present research, the enzyme was also immobilized in the well of a microassay plate by the sol-gel technique. The transglycosylation reaction was easily managed due to the immobilization. Furthermore, multiple use was possible by the encapsulated Endo-M. The resulting fluorescent oligosaccharides were separated by UPLC and efficiently detected by ESI-TOF-MS. Several oligosaccharides in ovalbumin were successfully identified by the proposed procedure.  相似文献   

11.
A high-resolution ultra-performance liquid chromatography/time-of-flight mass spectrometry (UPLC/TOFMS) method using in-source collision-induced dissociation (CID) was developed for globally profiling oxylipin-containing galactolipids in Arabidopsis wounded leaves. MS and pseudo-MS/MS spectra were obtained during a single analytical run by switching a lens of the TOFMS transfer optics from low to high voltage. Numerous known galactolipids were observed, and four novel mono- or di-galactosyl monoacylglycerides (MGMGs or DGMGs) containing oxophytodienoic acid (OPDA) or dinor-oxophytodienoic acid (dn-OPDA), esterified respectively at the sn1 and the sn2 positions, were identified. Rapid microisolation of the galactolipids followed by alkaline and enzymatic hydrolyses enabled the release of the esterified oxylipins, which allowed for the unambiguous characterization of the oxylipin-containing monoacylglycerides. Their strong induction in response to wounding indicates that these compounds are probably lysogalactolipids formed from galactosyldiglycerides in the injured tissues.  相似文献   

12.
An ultra-performance liquid chromatography/time-of-flight mass spectrometry (UPLC/TOF-MS)-based metabolomic approach was developed to characterize the metabolic profile associated with isoproterenol (ISO)-induced myocardial infarction (MI). Analysis of the serum samples revealed distinct changes in the biochemical patterns of ISO-induced rats. A multivariate statistical method, supervised partial least squares-discriminant analysis (PLS-DA), was then used for screening of potential biomarkers. As a result, 13 lipid biomarkers, including lysophosphatidylcholines (Lyso-PCs) and fatty acids were identified by the accurate mass measurement of TOF-MS. The relationship between abnormal lipid metabolism and the formation of MI were also studied. This work demonstrates the utility of UPLC/TOF-MS-based metabolic profiling combined with multivariate analysis as a powerful tool to further investigate the pathogenesis of cardiovascular diseases.  相似文献   

13.
Over the last decade, time-of-flight (TOF) instruments have increasingly been used as quantitation tools. In addition, because of their high resolving power, they can be used for verification of empirical formulas. Historically, TOF instruments have had limited quantitation capabilities because of their narrow dynamic range. However, recent advances have improved these limitations. This review covers the rationale for using TOF for LC detection, and describes the many methods currently in the literature for the quantitation of pharmaceuticals, environmental pollutants, explosives and many phytochemicals.  相似文献   

14.
The fact that the effects of herbal medicines (HMs) are brought about by their chemical constituents has created a critical demand for powerful analytical tools performing the chemical analysis to assure their efficacy, safety and quality. Liquid chromatography coupled to mass spectrometry (LC–MS) is an excellent technique to analyze multi-components in complex herbal matrices. Due to its inherent characteristics of accurate mass measurements and high resolution, time-of-flight (TOF) MS is well-suited to this field, especially for qualitative applications. The purpose of this article is to provide an overview on the potential of TOF, including the hybrid quadrupole- and ion trap-TOF (QTOF and IT-TOF), hyphenated to LC for chemical analysis in HMs or HM-treated biological samples. The peculiarities of LC–(Q/IT)TOF-MS for the analysis of HMs are discussed first, including applied stationary phase, mobile-phase selection, accurate mass measurements, fragmentation and selectivity. The final section is devoted to describing the applicability of LC–(Q/IT)TOF-MS to routine analysis of multi-components, including target and non-target (unknown) compounds, in herbal samples, emphasizing both the advantages and limitations of this approach for qualitative and quantitative purposes. The potential and future trends of fast high-performance liquid chromatography (HPLC) (e.g. rapid resolution LC and ultra-performance LC) coupled to (Q)TOF-MS for chemical analysis of HMs are highlighted.  相似文献   

15.
Ultra-performance liquid chromatography coupled to tandem mass spectrometry (UPLC–MS–MS) has been used for screening and quantification of 32 pesticides and metabolites in two fruit matrices. The compounds investigated belonged to different chemical families of insecticides, acaricides, fungicides, and herbicides; several metabolites were also included. Quantification was conducted using matrix-matched standards calibration; response was a linear function of concentration in the range tested (10–500 ng mL−1). The method was validated with blank samples of lemon and raisin spiked at 0.01 and 0.1 mg kg−1, and recoveries were satisfactory, between 70 and 110%, for most of the pesticides tested and relative standard deviations were below 15% (n = 5 at each spiking level). Excellent sensitivity resulted in limits of detection for all compounds well below 0.01 mg kg−1, with the limit of quantification being validated at 0.01 mg kg−1. The UPLC system generates narrow peaks (approx. 5 s), thus increasing peak height and improving sensitivity. This improved separation efficiency facilitates adequate resolution not only of the analytes but also of matrix interferences compared with conventional HPLC. The method developed could also resolve some geometric isomers. The main advantage of this approach is the high sample throughput achieved because of the short analysis time, which enables satisfactory separation of all the compounds in less than 5 min per sample.  相似文献   

16.
Liquid chromatography coupled to orthogonal acceleration time-of-flight mass spectrometry (LC/TOF) provides an attractive alternative to liquid chromatography coupled to triple quadrupole mass spectrometry (LC/MS/MS) in the field of multiresidue analysis. The sensitivity and selectivity of LC/TOF approach those of LC/MS/MS. TOF provides accurate mass information and a significantly higher mass resolution than quadrupole analyzers. The available mass resolution of commercial TOF instruments ranging from 10 000 to 18 000 full width at half maximum (FWHM) is not, however, sufficient to completely exclude the problem of isobaric interferences (co-elution of analyte ions with matrix compounds of very similar mass). Due to the required data storage capacity, TOF raw data is commonly centroided before being electronically stored. However, centroiding can lead to a loss of data quality. The co-elution of a low intensity analyte peak with an isobaric, high intensity matrix compound can cause problems. Some centroiding algorithms might not be capable of deconvoluting such partially merged signals, leading to incorrect centroids.Co-elution of isobaric compounds has been deliberately simulated by injecting diluted binary mixtures of isobaric model substances at various relative intensities. Depending on the mass differences between the two isobaric compounds and the resolution provided by the TOF instrument, significant deviations in exact mass measurements and signal intensities were observed. The extraction of a reconstructed ion chromatogram based on very narrow mass windows can even result in the complete loss of the analyte signal. Guidelines have been proposed to avoid such problems. The use of sub-2 microm HPLC packing materials is recommended to improve chromatographic resolution and to reduce the risk of co-elution. The width of the extraction mass windows for reconstructed ion chromatograms should be defined according to the resolution of the TOF instrument. Alternative approaches include the spiking of the sample with appropriate analyte concentrations. Furthermore, enhanced software, capable of deconvoluting partially merged mass peaks, may become available.  相似文献   

17.
Ultra-performance liquid chromatography (UPLC) was investigated as an alternative to high-performance liquid chromatography (HPLC) for analyzing pharmaceutical drug candidates. We previously developed a 96-well-based high-speed solubility assay system (HSSOL) using HPLC/UV and a LogD assay system (HSLogD) using HPLC/MS [Y. Dohta, T. Yamashita, S. Horiike, T. Nakamura, T. Fukami, Anal. Chem. 79 (2007) 8312]. We have introduced the UPLC/MS system into this previously developed HSSOL system to increase throughput. Results obtained by the UPLC/MS and HPLC/UV systems showed good agreement, validating the usefulness of the UPLC/MS system. A high-speed solubility assay system was developed employing the UPLC/MS system, thereby tripling the throughput.  相似文献   

18.
Withdrawal of the support for the REMEDi HS drug profiling system has necessitated its replacement within our laboratories with an alternative broad toxicological screening technique. To this end, a novel method, based on ultra-performance liquid chromatography (UPLC) and time-of-flight (TOF) mass spectrometry, was developed for the routine analysis of urine samples. Identification was achieved by comparison of acquired data to libraries containing more than 300 common drugs and metabolites, and was based on a combination of retention time, exact mass and fragmentation patterns. Validation data for the method is presented and comprised an evaluation of the following parameters: precision; transferability of the methodology between the six collaborating laboratories; specificity; extraction recovery and stability of processed samples; matrix effects and sensitivity.This paper presents the benefits of supplementary fragmentation data with particular regard to increasing specificity and confidence of identification and its usefulness with overdosed samples. The utility of the method was assessed by the parallel analysis of 30 authentic urine samples using the REMEDi HS and UPLC-TOF. The latter provided enhanced detection, leading to the identification of twice as many drugs. Furthermore it did not miss any compounds that were identified by REMEDi HS. The UPLC-TOF findings were further verified by a combination of data from three other conventional screening techniques, i.e., GC-MS, HPLC-DAD and UPLC-MS/MS.  相似文献   

19.
This study sought to develop techniques for LC/MS-based metabolomics and to verify that an MS/MS spectral tag (MS2T) could be used in practical secondary metabolite profiling. The retention time (RT), precursor ions, and fragment ions generated by nozzle-skimmer fragmentation were determined using ultra-performance liquid chromatography/time-of-flight mass spectrometry (UPLC/TOF-MS) and compared with the MS2T. A standard mix was analyzed with UPLC/TOF-MS under the same conditions as were used to construct the MS2T. The difference in RT for the standards was less than 0.15 min and the average RSD was about 2.8%, suggesting that the analysis was highly repeatable. Both precursor ions and fragment ions were observed when the cone voltage was 75 V. Experimental data and fragmentation pattern in the MS2T annotation list were highly similar. Wild-type and cas-1 mutant Arabidopsis thaliana samples treated with an elicitor were analyzed using UPLC/TOF-MS. Sixty-five peaks were successfully annotated. Fragment ions were observed with nozzle-skimmer fragmentation in 50 of 65 (77%) peaks. The reliability of annotation may have increased as a result of fragment ions. Results of multivariate analysis suggested that cas-1 was related to induction of the biosynthesis of these flavonoids. The devised method facilitated practical secondary metabolite profiling.  相似文献   

20.
Hugan tablet is a Chinese medicine preparation. It is composed of Bupleuri Radix, Artemisiae Scopariae Herba, Isatidis Radix, Schisandrae Chinensis Fructus, Suis Fellis Pulvis, and Vigna radiata L. It has the effects of dispersing stagnated liver qi, strengthening the spleen and eliminating food to be used for the treatment of chronic hepatitis and early cirrhosis. However, the chemical composition of Hugan tablet is complex and not fully understood, which hampers the research in pharmacology. In this study, a reliable method for the rapid analysis and identification of the chemical components in Hugan tablet by their characteristic fragments and neutral losses using ultra-performance liquid chromatography-quadrupole-exactive orbitrap mass spectrometry was developed. A total of 144 chemical components were tentatively identified, including 57 organic acids, 19 flavonoids, 23 alkaloids, 18 lignans, 7 saponins, and 20 others. These components may be the active ingredients of Hugan tablet. The established method can systematically and rapidly analyze the chemical components in Hugan tablet, which provides a basis for the pharmacodynamic substance study and is meaningful for the quality control of Hugan tablet.  相似文献   