首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到5条相似文献,搜索用时 0 毫秒
1.
The sensitivity of glycan analysis using nano-liquid chromatography interfaced with electrospray ionization mass spectrometry (ESI-MS) increases with the decrease of the mobile phase flow rate, accompanied by reduced ion suppression. In this study, we describe the preparation and performance of high efficiency 10 microm I.D. amine-bonded poly(vinylbenzyl chloride-divinylbenzene) hydrophilic interaction (HILIC) porous layer open tubular (PLOT) columns operated at 20 nL/min for the separation and analysis of glycan mixtures. HILIC-PLOT columns with a uniform porous polymer layer were reproducibly prepared ( approximately 4% RSD in retention time from column-to-column) via in situ polymerization, followed by one step modification with ethylenediamine. When coupled on-line with negative ESI-MS, low detection limits (0.3fmol) for a 3-sialyl-tetrasaccharide were achieved using a 2.5mx10 microm I.D. HILIC-PLOT column. A dextran ladder standard was used to evaluate the performance of the column, and high efficiency separation was achieved with detection of the dextrans up to G22 from approximately 50 fmol amounts injected. As an example of the high sensitivity of the column, MS(6) characterization of glycan structures was possible from the injection of 10 fmol of a neutral and sialylated glycan. As another example of high sensitivity LC-MS analysis of 3 ng of a PNGase F digest of ovalbumin allowed 28 N-linked glycans to be confidently identified from a single analysis. High quality MS/MS spectra for each ovalbumin glycan were acquired and manually interpreted for structure analysis. The HILIC-PLOT column is a very promising approach for LC-MS analysis of glycans at the ultratrace level.  相似文献   

2.
Precise proteomic profiling of limited levels of disease tissue represents an extremely challenging task. Here, we present an effective and reproducible microproteomic workflow for sample sizes of only 10,000 cells that integrates selective sample procurement via laser capture microdissection (LCM), sample clean-up and protein level fractionation using short-range SDS-PAGE, followed by ultrasensitive LC-MS/MS analysis using a 10 μm i.d. porous layer open tubular (PLOT) column. With 10,000 LCM captured mouse hepatocytes for method development and performance assessment, only 10% of the in-gel digest, equivalent to ~1000 cells, was needed per LC-MS/MS analysis. The optimized workflow was applied to the differential proteomic analysis of 10,000 LCM collected primary and metastatic breast cancer cells from the same patient. More than 1100 proteins were identified from each injection with >1700 proteins identified from three LCM samples of 10,000 cells from the same patient (1123 with at least two unique peptides). Label free quantitation (spectral counting) was performed to identify differential protein expression between the primary and metastatic cell populations. Informatics analysis of the resulting data indicated that vesicular transport and extracellular remodeling processes were significantly altered between the two cell types. The ability to extract meaningful biological information from limited, but highly informative cell populations demonstrates the significant benefits of the described microproteomic workflow.  相似文献   

3.
A high-throughput liquid chromatography/tandem mass spectrometry (LC/MS/MS) method, which combines on-line sample extraction through turbulent flow chromatography with a monolithic column separation, has been developed for direct injection analysis of drugs and metabolites in human plasma samples. By coupling a monolithic column into the system as the analytical column, the method enables running 'dual-column' extraction and chromatography at higher flow rates, thus significantly reducing the time required for the transfer and mixing of extracted fraction onto the separation column as well as the time for gradient separation. A strategy of assessing and reducing the matrix suppression effect on the on-line extraction LC/MS/MS has also been discussed. Experiments for evaluating the resolution, peak shape, sensitivity, speed, and matrix effect were conducted with dextromethorphan and its metabolite dextrorphan as model compounds in human plasma matrix. It was demonstrated that the total run time for this assay with a baseline separation of two analytes is less than 1.5 min.  相似文献   

4.
Hyung SW  Kim MS  Mun DG  Lee H  Lee SW 《The Analyst》2011,136(10):2100-2105
The microcapillary liquid chromatography (μLC)/tandem mass spectrometry (MS/MS) system has become a prevailing analytical platform in proteomics. Typical proteomic studies aimed at proteome-wide identification of peptides and proteins rely heavily on producing an accurate and reproducible solvent-composition gradient throughout microcapillary separation columns to improve LC separation. With the recent advent of targeted proteomic approaches utilizing the LC retention time as a physicochemical parameter for peptides, high reproducibility of LC separation additionally becomes an important factor. In this study, column temperature elevation is utilized to improve reproducibility and separation efficiency of the μLC-MS/MS system. The simple incorporation of a semi-rigid gas line heater allowed precise control of the temperature of microcapillary columns longer than 70 cm, up to 60 °C. Tryptic enolase peptides were used as a standard sample to evaluate the effect of the controlled temperature elevation on the peptide separation efficiency and reproducibility. In addition to the increased reproducibility in peptide elution time due to the controlled column temperature, the temperature elevation resulted in a decrease in the column operation pressure, which, in turn, allowed a higher solvent flow-rate to be employed using the same LC pumps, leading to further improvements in the performance of μLC systems.  相似文献   

5.
This paper describes approaches to optimize the chromatographic performance for our recently developed LC-MS platform, extended range proteomic analysis (ERPA), for comprehensive protein characterization at the ultratrace level. Large digested peptide fragments up to 10 kDa (e.g., from lysyl endopeptidase digestion) with or without modifications were well separated with high resolution using narrow bore (20 and 50 microm I.D.) poly(styrene-divinylbenzene) (PS-DVB) monolithic columns constructed by in situ solution polymerization. Importantly, the macroporous structure of the monolithic columns facilitated mass transport of large peptides with improved recovery relative to small pore size reversed-phase packings. High sequence coverage (>95%), including identification of phosphorylated and glycosylated particles was achieved for beta-casein and epidermal growth factor receptor (EGFR) at the 4 and 20 fmol levels per injection, respectively, using the 20 microm I.D. PS-DVB monolithic column. For peptides with greater ionization efficiency, the detection limit could be lowered to approximately 400 zmol. Typically, the separation system produced a peak capacity of approximately 200 for a 10 cm column. This paper demonstrates that narrow-bore monolithic columns are suitable for high sensitivity and high-resolution separation of large peptide fragments by LC-MS analysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号