1.
A microfluidic analytical system for the separation and detection of organic peroxides, based on a microchip capillary electrophoresis device with an integrated amperometric detector, was developed. The new microsystem relies on the reductive detection of both organic acid peroxides and hydroperoxides at -700 mV (vs. Ag wire/AgCl). Factors influencing the separation and detection processes were examined and optimized. The integrated microsystem offers rapid measurements (within 130 s) of these organic-peroxide compounds, down to micromolar levels. A highly stable response for repetitive injections (RSD 0.35-3.12%; n = 12) reflects the negligible electrode passivation. Such a "lab-on-a-chip" device should be attractive for on-site analysis of organic peroxides, as desired for environmental screening and industrial monitoring.  相似文献   

2.
A novel method for the determination of vitamin B12 by high-performance liquid chromatography with fluorescence detection is reported. The method was simple and highly sensitive with good precision. Vitamin B12 was analyzed by HPLC on a muBondapak C18 column (300x3.9 mm, 10 microm) with methanol-water (30:70) as mobile phase and fluorescence detection at 305 nm (with excitation at 275 nm). The calibration graph was linear from 1.000 to 100.0 ng ml(-1) for vitamin B12 with a correlation coefficient of 0.998 (n=6). The detection limit was 0.1 ng ml(-1). The method was successfully applied to the determination of vitamin B12 in vitamin B12 tablets, multivitamin tablets and fermentation medium. The recovery was from 94 to 102% and the relative standard deviation was in the range of 1.8 to 4.1%.  相似文献   

3.
A novel method for the trace analysis of 17beta-estradiol (E2) in river water sample was developed, which involved stir bar sorptive extraction (SBSE) with in situ acylation (first derivatization) and thermal desorption (TD) with quartz wool assisted (QWA) in tube silylation (second derivatization), followed by gas chromatography-mass spectrometry (GC-MS), and is called the "dual derivatization method." The optimum conditions for SBSE with in situ acylation, such as the volume of acetic acid anhydride and the extraction time, were investigated. In addition, the optimum conditions for TD with QWA in tube silylation, such as the volume of N,O-bis(trimethylsilyl)trifluoroacetamide (BSTFA) and the TD temperature and hold time, were investigated as well. The detection limit (S/N = 3) and the quantitation limit (S/N>10) of E2 in the river water sample were 0.5 and 2 pg ml(-1) (ppt), respectively, by the dual derivatization method. In addition, the detection limit was 0.1 pg ml(-1) by using dual derivatization method with multi-shot mode. The calibration curve for E2 was linear in the range of 0.002-10 ng ml(-1) with correlation coefficients >0.999. The average recoveries of E2 (n = 6) at the concentrations of 0.05 and 1.0 ng ml(-1) from the river water sample were 93.1 (RSD: 1.4%) and 98.4% (RSD: 0.8%), respectively, with correction using the added surrogate standard, 17beta-estradiol-(13)C(4). This simple, accurate, sensitive and selective analytical method may be applicable to the determination of trace amounts of E2 in water samples.  相似文献   

4.
Jiang L  Lu Y  Dai Z  Xie M  Lin B 《Lab on a chip》2005,5(9):930-934
This paper presents the development of a mini-electrochemical detector for microchip electrophoresis. The small size (3.6 x 5.0 cm2, W x L) of the detector is compatible with the dimension of the microchip. The use of universal serial bus (USB) ports facilitates installation and use of the detector, miniaturizes the detector, and makes it ideal for lab-on-a-chip applications. A fixed 10 M ohm feedback resistance was chosen to convert current of the working electrode to voltage with second gain of 1, 2, 4, 8, 16, 32, 64 and 128 for small signal detection instead of adopting selectable feedback resistance. Special attention has been paid to the power support circuitry and printed circuit board (PCB) design in order to obtain good performance in such a miniature size. The working electrode potential could be varied over a range of +/-2.5 V with a resolution of 0.01 mV. The detection current ranges from -0.3 x 10(-7) A to 2.5 x 10(-7) A and the noise is lower than 1 pA. The analytical performance of the new system was demonstrated by the detection of epinephrine using an integrated PDMS/glass microchip with detection limit of 2.1 microM (S/N = 3).  相似文献   

5.
A liquid chromatographic method for vitamin K1 in milk-based infant formula is described. The vitamins are extracted from infant formula by matrix solid-phase dispersion and quantitated by reversed-phase chromatography with fluorescence detection. Vitamin K1 is converted to the fluorescent hydroquinone with a postcolumn zinc reductive reactor. The limit of detection is 12 pg, and the limit of quantitation is 38 pg on-column. Linear responses were obtained in the range 0.55-22.1 ng/ml (r2 = 0.9998). Recoveries of vitamin K1 from an analyte-fortified blank material for milk-based infant formula averaged 91.7% (n = 25). The method provides a rapid, specific, and easily controlled assay for vitamin K1 in fortified infant formula.  相似文献   

6.
Fast and sensitive packed capillary column switching liquid chromatography methodology has been developed for the determination of the pesticide rotenone in river water. Sample volumes of up to 1 ml are loaded onto a 23 x 0.25 mm, 5 microm Kromasil C18 packed capillary precolumn using a noneluting solvent composition of water-acetonitrile (99:1, v/v) at flow-rates up to 100 microl/min prior to solute backflushing onto a 200 x 0.32 mm, 3.5 microm Kromasil C18 packed capillary analytical column using a mobile phase of water-acetonitrile (30:70, v/v) at a flow-rate of 5 microl/min. The method was evaluated using river water samples spiked with rotenone in the concentration range 0.5-50 ng/ml using UV detection. The within-assay precision was between 5.0 and 7.7% relative standard deviation (RSD, n = 6) and the between assay precision was between 7.5 and 8.9% RSD (n = 6). The method was linear within the investigated mass range displaying a calibration curve correlation factor of 0.997. The mass limit of detection was 10 pg corresponding to a concentration limit of detection of 10 pg/ml, using time-of-flight mass spectrometry.  相似文献   

7.
用异丙醇-硫酸铵双水相体系,利用维生素B12的疏水性和硫酸铵的盐析作用,在高浓度无机Co2+共存的情况下可有效地实现维生素B12的选择性分离富集.对双水相体系的组成、萃取时间和pH等实验参数进行了优化,在2.0mL样品、1.1g硫酸铵和200μL异丙醇组成的双水相体系中,对50μgL-1的维生素B12溶液经过萃取分离后富集倍数为11.8.取20μL双水相体系上相进行电热原子吸收检测,线性范围为2~100μgL-1,检出限为0.6μgL-1(3σ,n=11),相对标准偏差为2.8%(50μgL-1,n=9).将所建立的方法应用于功能饮料、保健药片、牛肝等实际样品中维生素B12的含量测定,加标回收率在97%~104%之间.  相似文献   

8.
Borowsky J  Collins GE 《The Analyst》2007,132(10):958-962
The ability to separate complex mixtures of analytes has made capillary electrophoresis (CE) a powerful analytical tool since its modern configuration was first introduced over 25 years ago. The technique found new utility with its application to the microfluidics based lab-on-a-chip platform (i.e., microchip), which resulted in ever smaller footprints, sample volumes, and analysis times. These features, coupled with the technique's potential for portability, have prompted recent interest in the development of novel analyzers for chemical and biological threat agents. This article will comment on three main areas of microchip CE as applied to the separation and detection of threat agents: detection techniques and their corresponding limits of detection, sampling protocol and preparation time, and system portability. These three areas typify the broad utility of lab-on-a-chip for meeting critical, present-day security, in addition to illustrating areas wherein advances are necessary.  相似文献   

9.
This paper introduces the chemiluminescence (CL) detection in oscillating reaction-based determinations using the analyte pulse perturbation technique, a straightforward and expeditious approach to deriving quantitative analytical information from oscillating chemical reactions. The behavior of the H(2)O(2)-KSCN-CuSO(4)-NaOH oscillating system in the presence of luminol was examined by using the proposed detection method and the classical potentiometric technique. Some analytical and practical aspects of both detection systems are discussed. A new analytical method for the determination of vitamin B(6) based on the sequential perturbation produced by different amounts of this substance on the oscillating chemical system was also developed in order to assess the potential of CL detection for routine analyses. The calibration curve thus obtained was linear over the range 0.5-2.0 mumol of vitamin B(6), and the precision and throughput were also quite good (3.04% as RSD and nine samples h(-1), respectively). The proposed method was validated by determining the vitamin in pharmaceutical preparations.  相似文献   

10.
In the last decade, saliva has been advocated as a non-invasive alternative to blood as a diagnostic fluid. However, use of saliva has been hindered by the inadequate sensitivity of current methods to detect the lower salivary concentrations of many constituents compared to serum. Furthermore, developments in the areas related to lab-on-a-chip systems for saliva-based point of care diagnostics are complicated by the high viscosity and heterogeneous properties associated with this diagnostic fluid. The biomarker C-reactive protein (CRP) is an acute phase reactant and a well-accepted indicator of inflammation. Numerous clinical studies have established elevated serum CRP as a strong, independent risk factor for the development of cardiovascular disease (CVD). CVD has also been associated with oral infections (i.e. periodontal diseases) and there is evidence that systemic CRP may be a link between the two. Clinical measurements of CRP in serum are currently performed with "high sensitivity" CRP (hsCRP) enzyme-linked immunosorbent assay (ELISA) tests that lack the sensitivity for the detection of this important biomarker in saliva. Because measurement of salivary CRP may represent a novel approach for diagnosing and monitoring chronic inflammatory disease, including CVD and periodontal diseases, the objective of this study was to apply an ultra-sensitive microchip assay system for the measurement of CRP in human saliva. Here, we describe this novel lab-on-a-chip system in its first application for the measurement of CRP in saliva and demonstrate its advantages over the traditional ELISA method. The increased sensitivity of the microchip system (10 pg ml(-1) of CRP with 1000-fold dilution of saliva sample) is attributed to its inherent increased signal to noise ratio, resulting from the higher bead surface area available for antigen/antibody interactions and the high stringency washes associated with this approach. Finally, the microchip assay system was utilized in this study to provide direct experimental evidence that chronic periodontal disease may be associated with higher levels of salivary CRP.  相似文献   

11.
建立了高效液相色谱二极管阵列检测(HPLC-DAD)法同时测定丹参滴注液中丹参素、原儿茶醛、迷迭香酸和丹酚酸B四种水溶性成分的含量。采用DiamonsilTMC18色谱柱(250×4.6 mm,5μm),以甲醇和5%冰乙酸为流动相进行梯度洗脱,流速为1.0mL/min,柱温30℃,检测波长为286 nm。在此色谱条件下四种水溶性成分可完全分离。丹参素、原儿茶醛、迷迭香酸和丹酚酸B的线性范围分别为0.2192~1.934μg(r=0.9999),0.03508~0.2456μg(r=1.0000),0.2592~1.814μg(r=1.0000),0.3864~2.705μg(r=0.9999)。平均回收率丹参素为102.6%,相对标准偏差(RSD)为0.55%;原儿茶醛为103.5%,RSD为0.42%;迷迭香酸为99.8%,RSD为0.68%;丹酚酸B为102.8%,RSD为0.49%。该方法简单、快速,四组分分离良好,可用于丹参滴注液的质量控制。  相似文献   

12.
Methods for Vitamin B5 determination in food products remain limited by their low sensitivity and poor selectivity. Here, we have developed a liquid chromatography-mass spectrometry (LC-MS) method for Vitamin B5 determination in wide range of fortified food products. Vitamin B5 was extracted from food samples by heat treatment and analysed by LC-MS in the positive mode using electrospray ionisation (ESI). Vitamin B5 was quantified using hopantenic acid (HOPA) as internal standard after their separation on a C18 narrow-bore column with a gradient of mobile phase made of water/acetonitrile and trifluoroacetic acid (TFA) 0.025%. MS with single ion monitoring mode at mass m/z 220 was used for Vitamin B5 quantification. Calibration curve between 0.5 and 10 microg/ml of Vitamin B5 was linear (r2=0.9993) and the detection limit was determined to be 800 pg. The overall quantitative efficiency of the method was evaluated using Nestle reference sample (infant formula). The intra-assay RSD was 4.8% (n=8), the inter-assay RSD 6.4% (n=4) and the recoveries of the spiked samples were above 95%. Application of the LC-MS method to Vitamin B5 determination in wide range of fortified food products including three US National Institute of Standards and Technology (NIST) reference samples (RM 8435, RM 8415 and SRM 1546) shows consistent results with those obtained by microbiology and recoveries of Vitamin B5 between 93 and 104% for the spiked samples.  相似文献   

13.
A system using a microwave induced plasma, as an emission source was optimized for total mercury determinations. The system contains a flow injection section in which mercury is reduced and deposited on a gold/platinum collector, and carried to the emission source. The microwave was generated in a Surfatron cavity. An experimental design was applied to optimize parameters concerning plasma conditions, amalgamation, desorption and mercury vapor generation. The limit of detection of the method was 14 pg ml(-1) of mercury, using peak area mode while LDs was 1.3 pg ml(-1) using peak height mode, with a 2% RSD and a linear dynamic range of almost three orders of magnitude. The accuracy was assessed using a certified reference material of atmospheric particulate National Institute of Standards and Technology (NIST) 2704. No significant difference at 95% confidence level was observed between the certified value and our result.  相似文献   

14.
Determination of small amounts of vitamin K1 (0.8 microg/g) in nutritional supplements with high fat content (20 mg/g) was performed by solid-phase extraction and high-performance liquid chromatography (HPLC) with fluorescence detection after reduction on a platinum oxide catalyst. The concentration ratio of plant oils to vitamin K1 (0.8 microg/g) was about 25,000:1. A sample solution was applied to a solid-phase extraction cartridge and vitamin K1 was eluted with ethanol, followed by HPLC. The proposed method was simple, rapid (analysis time: ca. 12 min), sensitive [detection limit: ca. 0.1 pg per injection (100 microl) at a signal-to-noise ratio of 3:1], highly selective and reproducible [relative standard deviation: ca. 1.3%. (n=5)]. The calibration graph of vitamin K1 was linear in the range of 0-2 pg per injection (100 microl). Recovery of vitamin K1 was over 90% by the standard addition method.  相似文献   

15.
《Analytical letters》2012,45(7):1245-1263
Abstract

Sensitive and simple second derivative UV spectrophotometric and HPLC with fluorometric detection methods were developed for cycloserine based on derivatization with 9-chloro-10-methyl acridinium triflate (CMAT) to yield a reaction product which absorbs in the UV at 361 nm and is fluorescent using excitation and emission wavelengths of 257 nm and 475 nm, respectively. The CMAT derivatization reaction takes 30 minutes at 70°C. Cycloserine was linear in the 0.3 – 5.0 μg/ml range (r=0.999, n=5) for the second derivative UV method and the 0.8 – 5 μg/ml range for the HPLC method (r=0.999, n=5). The limit of detection for cycloserine in the HPLC method can be improved to 0.15 μg/ml with the addition of glacial acetic acid to the analytical sample. The HPLC assay was applied to the determination of cycloserine in spiked human urine samples. The correlation coefficient (r) was in the 0.999 range and sensitivity was at the low pg/ml level.  相似文献   

16.
This paper shows an analytical methodology based on solid-phase extraction by XAD-2 adsorbent and gas chromatography (GC) coupled with nitrogen-phosphorus (NPD) and ion-trap mass spectrometry detectors (ITMS) in negative chemical ionization (NCI) mode analyses for investigating organophosphorus pesticides (OPs) at trace levels (in nanograms per cubic meter) in the atmosphere: in particular, we set up a procedure for analyzing 38 OPs. For the analytical methodology linearity responses have been obtained in GC-NPD (r > 0.9982) and GC-NCI/ITMS (r > 0.9974) in a large linearity range (0.10-500 pg μL(-1) in both cases) whereas the limits of detection range between 0.01 and 0.03 pg μL(-1) in both the techniques with a relative standard deviation (RSD) below 9.0 in both cases. Particular attention has been devoted to investigate the effect of different solvents (n-hexane, benzene, chloroform, carbon disulfide, acetonitrile) on the OP recovery as well the breakthrough volumes have been evaluated (100% recovery up to 4,286 L g(-1)). The study has also investigated the OP recoveries at different sampling flow rates (1.5 and 2.0 L min(-1)) for determining the optimal conditions for sample collection. Finally, the whole approach has been successfully applied to real samples collected in four different areas in the Molise region (Central Italy) during different seasons: the results show that parathion-ethyl, dimethoate, omethoate, and malathion are present in all periods at low levels (ranging between 70 and 10 ng m(-3)): their levels in such periods can be correlated with spraying as well atmospheric conditions favoring the dispersion/accumulation of these pollutants.  相似文献   

17.
提出了用芯片电泳分离-激光诱导荧光光谱法测定儿茶酚胺类物质的方法。采用自制的无泵负压进样系统,避免了进样歧视效应。在优化的条件下,去甲肾上腺素(NE)、多巴胺(DA)和肾上腺素(E)可在1 min内完全分离。3种儿茶酚胺的平均迁移时间依次为30.59,37.23,46.43 s,其相对标准偏差(n=7)依次为1.10%,1.28%,0.45%。3种物质的线性范围为0.3~5.0 mg.L-1(NE及DA)和0.05~4.0 mg.L-1(E),检出限(3S/N)依次为30,30,10μg.L-1。  相似文献   

18.
A new doping control screening method has been developed, for the analysis of doping agents in human urine, using HPLC/orbitrap with in-source collision-induced dissociation and atmospheric pressure chemical ionization. The developed method allows the detection of 29 compounds, including agents with antiestrogenic activity, beta(2) agonists, exogenous anabolic steroids, and other anabolic agents. The mass accuracy of this method is better at 2 ppm using an external reference. The detection limit for all compounds tested was better than 100 pg/ml. The recoveries of most analytes were above 70%. The measured median repeatability values for doping agents included in the method at concentrations of 1 and 10 ng/ml were 21 and 17%, respectively. The relative standard deviation (RSD) of the intraday precision (n = 6) ranged from RSD = 16-22%, whereas the interday precision (n = 18), ranged from RSD = 17-26%, depending on the solute concentration investigated.  相似文献   

19.
This paper presents a capillary electrophoresis poly(methyl methacrylate) (PMMA) based microchip for electrochemical detection applications featuring embedded gold nanoelectrode ensemble (GNEE) working and decoupler electrodes. In fabricating the microchip, the GNEE films are pressed directly onto the metallic electrode structures using a hot embossing technique, and the microfluidic channels are then sealed using a low-temperature azeotropic solvent bonding method. The detection performance of the microchip is evaluated using dopamine and catechol analytes for illustration purposes. The experimental results show that the GNEE working electrode provides a significantly higher signal response than that obtained from a bulk gold electrode when applied to the detection of dopamine analyte. Compared to a conventional bulk palladium decoupler electrode, the GNEE decoupler electrode reduces both the amplitude of the charge current (3.5 nA vs. 18.7 nA) and the baseline drift at higher separation voltages. The measured baseline current drift for the microchip equipped the proposed GNEE decoupler electrode is around three times smaller than the microchip with the palladium decoupler electrode under the applied separation electric field from 40 V/cm to 240 V/cm. Finally, when detecting a mixture of 1mM dopamine and 1mM catechol, the calculated signal response of the microchip with a GNEE decoupler electrode is approximately five times higher than that obtained from a microchip with a bulk Pd decoupler electrode, resulting in the detection limit of 1 microM for the proposed GNEE-based microchip device. Overall, the results indicate that the proposed capillary electrophoresis-electrochemical detection (CE-ED) microchip with embedded GNEE working and decoupler electrodes provides an ideal solution for sample detection in lab-on-a-chip and micro total analysis applications.  相似文献   

20.
The present work displays capillary liquid chromatographic column switching methodology tailored for determination of benzo[a]pyrene tetrol isomers in biological matrices using on-line fluorescence and micro-electrospray ionization mass spectrometric detection. A well-established off-line crude solid phase extraction procedure was used in order to make the method compatible with several biological matrices. The solid phase extraction eluates were evaporated to dryness, redissolved in 1.0 ml methanol:water (10:90, v/v), loaded onto a 0.32 mm I.D. x 40 mm 5 microm Kromasil C(18) pre-column for analyte enrichment and back-flushed elution onto a 0.30 mm I.D. x 150 mm 3.5 microm Kromasil C(18) analytical column. The samples were loaded with a flow rate of 50 microl min(-1) and the tetrols were separated at a flow rate of 4 microl min(-1) with an acetonitrile:10 mM ammonium acetate gradient from 10 to 90%. A sample loading flow rate up to 50 microl min(-1) was allowed. The fluorescence excitation and emission were set to 342 and 385 nm, respectively, while mass spectrometric detection of the benzo[a]pyrene tetrols was obtained by monitoring their [M - H](-) molecular ions at m/z 319. The method was validated over the concentration range 0.1-50 ng ml(-1) benzo[a]pyrene tetrols in a cell culture medium with 100 microl injection volume, fluorescence detection and the first eluting tetrol isomer as model compound, resulting in a correlation coefficient of 0.993. The within-assay (n= 6) and between-assay (n= 6) precisions were determined to 2.6-8.6% and 3.8-9.6%, respectively, and the recoveries were determined to 97.9-102.4% within the investigated concentration range. The mass limit of detection (by fluorescence) was 3 pg for all the tetrol isomers, corresponding to a concentration limit of detection of 30 pg ml(-1) cell culture medium. The corresponding mass spectrometric mass limits of detection were 4-10 pg, corresponding to concentration limits of detection of 40-100 pg ml(-1) cell culture medium.  相似文献   