共查询到20条相似文献,搜索用时 0 毫秒
1.
The analytical performances of two triple-quadrupole instruments, which differ in their atmospheric-pressure sources, were evaluated for native amino acid analysis. The Applied Biosystems/Sciex API 300 instrument was equipped with a turboIon Spray source and a curtain gas interface while the Waters/Micromass Quattro Ultima instrument was characterized by its Z-spray source. Liquid chromatography/mass spectrometry analysis of native amino acids requires volatile ion-pairing mobile phase additives (mainly perfluorinated carboxylic acids). The effects of the structure and concentration of the ion-pairing reagents as well as the organic modifier percentage on the electrospray response of amino acids were studied in detail. The most favourable chromatographic conditions depend strongly on the mass spectrometer used. Several instrumental parameters were also studied, including spray voltage, transmission lens voltages, temperature of desolvation and auxiliary gas flow rates. The results show substantial qualitative differences depending on the instrument geometry. The quantitative performances of the two triple-quadrupole mass spectrometers were evaluated in terms of limits of detection and quantification. The effects of the matrix on the analyte ionization were also examined, and the long-term stability of the electrospray performance was studied over 12 h using a mobile phase containing the perfluorinated ion-pairing reagents. The study provides information on the robustness of the MS instrument and its detection sensitivity towards native amino acid analysis. It appears that each instrument has its good and bad points since one provides higher sensitivity while another is more robust. 相似文献
2.
《Journal of separation science》2017,40(7):1482-1492
We developed a straightforward, robust, and relatively fast method for the analysis of amino acids by mixed‐mode high‐performance liquid chromatography coupled to electrospray ionization tandem mass spectrometry. The method does not involve derivatization and allows the detection of 21 amino acids, representing a wide range of isoelectric points, in less than 40 min. Chromatographic separation was governed by a silica‐based mixed‐mode column providing simultaneous hydrophobic and ion exchange separation mechanisms. The use of tandem mass spectrometry increased selectivity, reducing potential problems associated with poor selectivity in the chromatographic system. For an injection volume of 1 μL, we obtained detection limits <3 μM for the majority of analytes. For all analytes, a linearity of r > 0.99 was obtained, recovery in matrix was >86%, and the retention times were highly reproducible. The method was successfully applied to soil solution and fungal culture samples, demonstrating the advantages in successfully avoiding issues associated with high amounts of substances that may interfere with derivatization‐based methods. This method represents an alternative to derivatization‐based methods and can be applied in areas where sample matrices are highly complex. 相似文献
3.
Vas G Conkrite K Amidon W Qian Y Bánki K Perl A 《Journal of mass spectrometry : JMS》2006,41(4):463-469
Transaldolase (TAL) is a key enzyme of the pentose phosphate pathway (PPP). TAL deficiency is a newly recognized cause of liver cirrhosis. We have developed an ion-pair LC separation combined with negative ion electrospray MS/MS detection method to assess PPP metabolites in urine samples from TAL-deficient mice. Sedoheptulose 7-phosphate (S7P), C5-polyols D-arabitol and D-ribitol, and 6-phosphogluconate (6PG) levels were markedly increased in urine of TAL-deficient mice with respect to those of wild-type and heterozygote littermates. The detection limits of S7P, D-arabitol, and 6PG were 0.15 +/- 0.015 pmol, 3.5 +/- 0.41 pmol, and 0.61 +/- 0.055 pmol, respectively. The limit of quantitation was 0.4 +/- 0.024 nmol/ml for S7P, 1.6 +/- 0.11 nmol/ml for 6PG and 10 +/- 0.7 nmol/ml for D-arabitol. Additional metabolites, hexose 6-phosphates (m/z 259), D-ribose 5-phosphate and D-xylulose 5-phosphate (m/z 229), D-fructose 1,6-diphosphate (m/z 339), C6-polyols (m/z 181) and GSSG (m/z 611), that have been positively identified in mouse urine, showed similar levels in control and TAL-deficient mice. 相似文献
4.
Free amino acids analysis by liquid chromatography with tandem mass spectrometry in several botanicals with antioxidant character 下载免费PDF全文
A novel method based on liquid chromatography with tandem mass spectrometry for the analysis of 19 amino acids in plant materials is described. For the analysis, the plant material is extracted with 0.1 N hydrochloric acid with internal standards present in the extraction solution. The filtered extracts are injected using no clean‐up into the liquid chromatographic system coupled with a triple‐quadrupole tandem mass spectrometer with an electrospray ionization source. The analytes are separated using ion pair chromatography on a reversed‐phase column. The detection is performed in multiple‐reaction monitoring positive‐ion mode. Quantitation is obtained using calibrations. The validated procedure has been applied for the analysis of amino acids in 18 samples of plant material including botanicals with antioxidant character. The analysis requires 16 min separation time, has excellent precision and accuracy allowing amino acid analysis in a wide range of concentrations. 相似文献
5.
《Biomedical chromatography : BMC》2018,32(7)
A highly sensitive method was developed for the analysis of short‐chain perfluorinated alkyl acids (PFAAs) in serum samples using solid‐phase extraction (SPE) coupled with ion chromatography–electrospray ionization–mass spectrometry. The synthesized amino‐functionalized graphene oxide nanocomposites were used as an SPE sorbent for the enrichment of trace analytes and purification of samples. They exhibited high selectivity to polar compounds. The suppressor was employed to remove counterions and reduce background signals of mobile phase. These two crucial steps could effectively eliminate matrix effects and enhance analytical sensitivity. The lowest limits of quantification were 2.0 μg L−1 for perfluorobutanoic acid and perfluorovaleric acid, 1.0 μg L−1 for perfluorocaproic acid and 0.50 μg L−1 for perfluorobutane sulfonic acid, respectively. The procedure was successfully applied for determination of trace PFAAs in 25 serum samples. Mean recoveries ranged from 86.3 to 101.4% with relative standard deviations of 1.6–6.8%. The method allowed an excellent separation and quantification of short‐chain PFAAs that were difficult to analyze by conventional chromatography. 相似文献
6.
Analysis of stable and radioactive isotopes from bone collagen provides useful information to archaeologists about the origin and age of bone artifacts. Isolation and analysis of single amino acids from the proteins can provide additional and more accurate information by removing contamination and separating a bulk isotope signal into its constituent parts. In this paper, we report a new method for the separation and isolation of underivatized amino acids from bone collagen, and their analysis by isotope ratio MS and accelerator MS. RP chromatography is used to separate the amino acids with nonpolar side chains, followed by an ion pair separation to isolate the remaining amino acids. The method produces single amino acids with little or no contamination from the separation process and allows for the measurement of accurate stable isotope ratios and pure samples for radiocarbon dating. 相似文献
7.
《Journal of separation science》2018,41(3):689-696
Chemical warfare agents such as organophosphorus nerve agents, mustard agents, and psychotomimetic agent like 3‐quinuclidinylbenzilate degrade in the environment and form acidic degradation products, the analysis of which is difficult under normal analytical conditions. In the present work, a simultaneous extraction and derivatization method in which the analytes are butylated followed by gas chromatography and mass spectrometric identification of the analytes from aqueous and soil samples was carried out. The extraction was carried out using ion‐pair solid‐phase extraction with tetrabutylammonium hydroxide followed by gas chromatography with mass spectrometry in the electron ionization mode. Various parameters such as optimum concentration of the ion‐pair reagent, pH of the sample, extraction solvent, and type of ion‐pair reagent were optimized. The method was validated for various parameters such as linearity, accuracy, precision, and limit of detection and quantification. The method was observed to be linear from 1 to 1000 ng/mL range in selected ion monitoring mode. The extraction recoveries were in the range of 85–110% from the matrixes with the limit of quantification for alkyl phosphonic acids at 1 ng/mL, thiodiglycolic acid at 20 ng/mL, and benzilic acid at 50 ng/mL with intra‐ and interday precisions below 15%. The developed method was applied for the samples prepared in the scenario of challenging inspection. 相似文献
8.
The kinetic method has been extended to enantiomeric excess (ee) determinations on amino acids present in mixtures. Singly charged trimeric clusters [Cu(II)(ref*)(2)(A(m)) - H](+) are readily generated by electrospraying solutions containing Cu(II), a chiral reference ligand (ref*), and the amino acids (analytes A(m), m = 1-3). A trimeric cluster ion for each amino acid is individually mass-selected and then collisionally activated to cause dissociation by competitive loss of either the reference ligand or the analyte. For each analyte in the mixture, as shown from separate experiments, the logarithm of the ratio of the fragment abundances for the complex containing one enantiomer of this analyte expressed relative to that for the fragments of the corresponding complex containing the other enantiomer is linearly related to the enantiomeric composition of the amino acid. Formation and dissociation of each trimeric complex ion are shown to occur independently of the presence of other analytes. Chiral selectivity appears to be an intrinsic property and the chiral selectivity R(chiral(m)) measured from the mixture of analytes is equal to R(chiral) measured for the pure analyte. The sensitive nature of the methodology and the linear relationship between the logarithm of the fragment ion abundance ratio and the optical purity, characteristic of the kinetic method, allow the determination of chiral impurities of less than 2% ee in individual compounds present in mixtures by simply recording the ratios of fragment ion abundances in a tandem mass spectrum. 相似文献
9.
《Journal of separation science》2018,41(1):385-397
This review presents an overview and recent progress of strategies for detecting isomerism in peptides, with focus on d /l epimerization and the various isomers that the presence of an aspartic acid residue may yield in a protein or peptide. While mass spectrometry has become a majorly used method of choice within proteomics, isomerism is inherently difficult to analyze because it is a modification that does not yield any change in mass of the analyte. Here, several techniques used for analysis of peptide isomerism are discussed, including enzymatic assays, liquid chromatography, and capillary electrophoresis. Recent progress in method development using mass spectrometry is also discussed, including labeling strategies, fragmentation techniques, and ion‐mobility spectrometry. 相似文献
10.
Na Guo Dawei Yang Xiaofang Yang Han Yan Bin Fan Jingang Dai Yan Lei Dan Yan 《Journal of separation science》2019,42(20):3173-3181
A rapid, sensitive, and widely applicable method for the simultaneous quantitative analysis of 20 underivatized amino acids in different biological matrices, including serum, plasma, and tissue homogenates, using ultra high performance liquid chromatography with tandem mass spectrometry was developed and validated. Only 4 µL of serum, plasma, or tissue homogenate was extracted with 996 µL of solution (1.7 mM ammonium formate in 85% acetonitrile containing 0.1% formic acid) containing 100 ng/mL phenylalanine‐d5 as an internal standard without any further derivatization step. In addition, the matrix effects were small because a large volume of extraction solution was used. The total run time including reequilibration was 13 min. The results of linearity, accuracy, repeatability, precision, limits of detection, limits of quantification, and sample stability were sufficient to allow the measurement of the amino acids in different biological matrices. We conclude that our method is rapid, sensitive, and widely applicable and represents an improvement over other currently available technologies. 相似文献
11.
Individuals with maple syrup urine disease (MSUD) have an inherited metabolic disorder resulting in a deficiency in the branched-chain keto-acid dehydrogenase complex. As a result, these individuals have elevated concentrations of the branched-chain amino acids valine, isoluecine, allo-isoleucine, and leucine. MSUD presents in the first few days of life and progression may lead to irreversible intellectual disability, coma, cerebral edema, and death. However, early diagnosis and intervention can mitigate or eliminate many of the potential adverse effects. Consequently, it is important to develop techniques to screen for MSUD. We have developed an LC-MS/MS assay for the diagnosis of MSUD. The method is amenable to high-throughput formats due to the minimal sample prep required. The assay was shown to be robust, precise, and accurate. Finally, we identified and addressed some of the problems associated with working with bloodspots and implemented satisfactory approaches to overcoming these problems. 相似文献
12.
《Journal of mass spectrometry : JMS》2018,53(10):997-1004
Ionization efficiency (IE) in mass spectrometry (MS) has been studied for many different compounds, and different IE scales have been constructed in order to quantitatively characterize IE. In the case of MS, derivatization has been used to increase the sensitivity of the method and to lower the limits of detection. However, the influence of derivatization on IE across different compounds and different derivatization reagents has not been thoroughly researched, so that practitioners do not have information on the IE‐enhancing abilities of different derivatization reagents. Moreover, measuring IE via direct infusion of compounds cannot be considered fully adequate. Since derivatized compounds are in complex mixtures, a chromatographic method is needed to separate these compounds to minimize potential matrix effects. In this work, an IE measurement system with a chromatographic column was developed for mainly amino acids and some biogenic amines. IE measurements with liquid chromatography electrospray ionization mass spectrometry (LC/ESI/MS) were carried out, and IE scales were constructed with a calibration curve for compounds with and without derivatization reagent diethyl ethoxymethylenemalonate. Additionally, eluent composition effects on ionization were investigated. Results showed that derivatization increases IE for most of the compounds (by average 0.9 and up to 2‐2.5 logIE units) and derivatized compounds have more similar logIE values than without derivatization. Mobile phase composition effects on ionization efficiencies were negligible. It was also noted that the use of chromatographic separation instead of flow injection mode slightly increases IE. In this work, for the first time, IE enhancement of derivatization reagents was quantified under real LC/ESI/MS conditions and obtained logIE values of derivatized compounds were linked with the existing scale. 相似文献
13.
Characterization of N,N‐dimethyl amino acids by electrospray ionization–tandem mass spectrometry 下载免费PDF全文
V. Naresh Chary B. Sudarshana Reddy Ch. Dinesh Kumar R. Srinivas S. Prabhakar 《Journal of mass spectrometry : JMS》2015,50(5):771-781
Methylation is an essential metabolic process for a number of critical reactions in the body. Methyl groups are involved in the healthy function of the body life processes, by conducting methylation process involving specific enzymes. In these processes, various amino acids are methylated, and the occurrence of methylated amino acids in nature is diverse. Nowadays, mass‐spectrometric‐based identification of small molecules as biomarkers for diseases is a growing research. Although all dimethyl amino acids are metabolically important molecules, mass spectral data are available only for a few of them in the literature. In this study, we report synthesis and characterization of all dimethyl amino acids, by electrospray ionization–tandem mass spectrometry (MS/MS) experiments on protonated molecules. The MS/MS spectra of all the studied dimethyl amino acids showed preliminary loss of H2O + CO to form corresponding immonium ions. The other product ions in the spectra are highly characteristic of the methyl groups on the nitrogen and side chain of the amino acids. The amino acids, which are isomeric and isobaric with the studied dimethyl amino acids, gave distinctive MS/MS spectra. The study also included MS/MS analysis of immonium ions of dimethyl amino acids that provide information on side chain structure, and it is further tested to determine the N‐terminal amino acid of the peptides. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
14.
Holcapek M Volná K Jandera P Kolárová L Lemr K Exner M Církva A 《Journal of mass spectrometry : JMS》2004,39(1):43-50
High-performance liquid chromatography/mass spectrometry (HPLC/MS) analysis of anionic species such as sulphonic acid dyes and intermediates requires volatile ion-pairing mobile phase additives. Six di- and trialkylammonium acetates were compared with tetraalkylammonium salts and ammonium acetate in the concentration range 0-20 mmol l(-1) as mobile phase additives for HPLC/MS of polysulphonated compounds. The effects of the structure and concentration of the ion-pairing reagents on the electrospray response of mono-, di- and tetrasulphonic aromatic acids and acid dyes were studied in detail. Further, five different mass analysers and instrument geometries were compared. A higher signal decrease is observed with linear geometry instruments in comparison to orthogonal or even Z-spray geometry mass spectrometers. The concentration of mobile phase additives has a significant influence on the abundance ratios of multiply charged ions in the mass spectra of polysulphonated compounds. The competing ions of sulphonic acids may also cause significant signal suppression. 相似文献
15.
Carmela Maria Montone Michela Antonelli Anna Laura Capriotti Chiara Cavaliere Giorgia La Barbera Susy Piovesana Aldo Lagan 《Journal of separation science》2019,42(10):1938-1947
An analytical method for determining seleno‐methionine, methyl‐seleno‐cysteine, and seleno‐cystine in wheat bran was developed and validated. Four different extraction procedures were evaluated to simultaneously extract endogenous free and conjugated seleno‐amino acids in wheat bran in order to select the best extraction protocol in terms of seleno amino acid quantitation. The extracted samples were subjected to a clean‐up by a reversed phase/strong cation exchange solid‐phase extraction and analyzed by chiral hydrophilic interaction liquid chromatography‐tandem mass spectrometry. The optimized extraction protocol was employed to validate the methodology. Process efficiency ranged from 58 to 112% and trueness from 73 to 98%. Limit of detection and limit of quantification were lower than 1 ng/g. Four wheat bran samples were analyzed for both total Se and single seleno‐amino acids determination. The results showed that Se‐ seleno‐methyl‐l selenocysteine was the major seleno‐amino acid in wheat bran while seleno‐methionine and seleno‐cysteine were both minor species. 相似文献
16.
17.
Eunju Cha Sohee Kim Hee Won Kim Kang Mi Lee Ho Jun Kim Oh‐Seung Kwon Jaeick Lee 《Biomedical chromatography : BMC》2016,30(4):555-565
The relationships between the ionization profile, sensitivity, and structures of 64 exogenous anabolic steroids (groups I–IV) was investigated under electrospray ionization (ESI) conditions. The target analytes were ionized as [M + H]+ or [M + H–nH2O]+ in the positive mode, and these ions were used as precursor ions for selected reaction monitoring analysis. The collision energy and Q3 ions were optimized based on the sensitivity and selectivity. The limits of detection (LODs) were 0.05–20 ng/mL for the 64 steroids. The LODs for 38 compounds, 14 compounds and 12 compounds were in the range of 0.05–1, 2–5 and 10–20 ng/mL, respectively. Steroids including the conjugated keto‐functional group at C3 showed good proton affinity and stability, and generated the [M + H]+ ion as the most abundant precursor ion. In addition, the LODs of steroids using the [M + H]+ ion as the precursor ion were mostly distributed at low concentrations. In contrast, steroids containing conjugated/unconjugated hydroxyl functional groups at C3 generated [M + H ? H2O]+ or [M + H ? 2H2O]+ ions, and these steroids showed relatively high LODs owing to poor stability and multiple ion formation. An LC‐MS/MS method based on the present ionization profile was developed and validated for the determination of 78 steroids (groups I–V) in human urine. Copyright © 2015 John Wiley & Sons, Ltd. 相似文献
18.
Talaty ER Van Stipdonk MJ Hague MJ Provenzano FA Boese CA 《Journal of mass spectrometry : JMS》2002,37(1):31-40
The ring opening of 1,3-di-tert-butylaziridinone by tert-butylamine and aniline was investigated by using electrospray ionization and collision-induced dissociation in an ion trap mass spectrometer in conjunction with (15)N labeling of the two amine nucleophiles. Using the MS(n) capabilities of the ion trap instrument, we were able to monitor the retention of the (15)N label through successive fragmentation steps. Both amines exhibited a remarkable degree of selectivity in that they both cleaved exclusively the 1,3-bond (the alkyl-nitrogen bond). This result is in contrast to that obtained previously with methylamine, which cleaved just the opposite bond, namely, the 1,2-bond (the acyl-nitrogen bond). These contrasting results could not have been predicted by previously published guidelines. 相似文献
19.
Martinović S Veenstra TD Anderson GA Pasa-Tolić L Smith RD 《Journal of mass spectrometry : JMS》2002,37(1):99-107
The post-genomic era and increased demands for broad proteome measurements have greatly increased the needs for protein identification. We describe a strategy that uses accurate mass measurements and partial amino acid content information to unambiguously identify intact proteins, and show its initial application to the proteomes of Escherichia coli and Saccharomyces cerevisiae. Proteins were extracted from the organisms grown in minimal medium or minimal medium to which isotopically labeled leucine (Leu-D(10)) had been added. The two protein extracts were mixed and analyzed by capillary isoelectric focusing (CIEF) coupled with Fourier transform ion cyclotron resonance mass spectrometry (FTICR). The incorporation of the isotopically labeled residue has no effect on the CIEF separation of proteins, and both isotopically labeled and unlabeled versions of specific proteins are observed within the same mass spectrum. The difference in the mass of the unlabeled and labeled proteins is used to determine the number of Leu residues present in a particular protein. Proteins can then often be unambiguously identified based on their accurately determined molecular mass and the additional constraint provided by number of Leu residues. The identities of proteins were further confirmed by repeating CIEF/FTICR measurements with samples that contain other isotopically labeled amino acid residues (e.g. His, Arg, Ile, Phe, Lys). A theoretical study of the amino acid composition (for a difference in the amino acid sequence) showed the constraints needed in order to identify the protein unambiguously. Additionally, the mass differences between the predicted and the experimental accurate mass measurement provide insights into the nature of simple post-translational modifications. 相似文献
20.
建立了离子色谱-质谱联用技术测定活性污泥样品中高氯酸盐的分析方法。以高容量、强亲水性的IonPacAS20(2mm)阴离子交换柱为分析柱,EGC在线产生等浓度KOH为淋洗液,淋洗液经抑制成水后将样品带入质谱检测。ESI-MS-MS以多元反应监测模式监控100.8/84.9、98.8/66.9、100.8/68.9和98.8/82.9离子对,以98.8/82.9离子对的峰面积进行定量。该方法对高氯酸盐的检出限(S/N=3)为0.01μg/L,高氯酸盐在0.05~100μg/L浓度范围内具有良好的线性,线性相关系数r=0.9988。0.2μg/L的标准溶液重复进样9次,高氯酸盐峰面积的相对标准偏差(RSD)为2.3%。运用该方法测定采自不同地区的活性污泥样品中的高氯酸盐,并对样品加标回收,得回收率在88.5%~102.2%之间。 相似文献