首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 10 毫秒
1.
A new rapid flow injection procedure for the simultaneous determination of nitrate, nitrite and ammonium in single flow injection analysis system is proposed. The procedure combines on-line reduction of nitrate to nitrite and oxidation of ammonium to nitrite with spectrophotometric detection of nitrite by using the Griess-llosvay reaction. The formed azo dye was measured at 543 nm. The influence of reagent concentration and manifold parameters were studied. Nitrite, nitrate and ammonium can be determined within the range of 0.02–1.60 μg mL−1, 0.02–1.60 μg mL−1 and 0.05–1.40 μg mL−1, respectively. R.S.D. values (n = 10) were 2.66; 1.41 and 3.58 for nitrate, nitrite and ammonium, respectively. This procedure allows the determination and speciation of inorganic nitrogen species in soils with a single injection in a simple way, and high sampling rate (18 h−1). Detection limits of 0.013, 0.046 and 0.047 μg mL−1were achieved for nitrate, nitrite and ammonium, respectively. In comparison with others methods, the proposed one is more simple, it uses as single chromogenic reagent less injection volume (250 mL in stead of 350 mL) and it has a higher sampling rate.  相似文献   

2.
基于苯胺与亚硝酸盐的重氮化反应及反应产物与甲萘酚的显色,借助流动分析技术,实现了海水中苯胺含量的分析测定。体系以30.9g/L的NaCl做载液、人工海水配制标准样品,对各个影响因素进行了优化。苯胺浓度在0.01~1.0mg/L范围内与相对峰高呈线性关系,线性方程ΔH(mV)=200.53ρ+1.0728(n=8,ρ为苯胺浓度mg/L),相关系数R2=0.9982。方法的检出限(3σ)为0.005mg/L,相对标准偏差(RSD)为4.8%(n=11)。考察了共存离子、不同盐度样品对分析测定的影响。用于实际海水样品的分析,回收率为95.8%~106.6%。  相似文献   

3.
建立了连续测定NO2-和NO3-的柱后在线衍生结合流动注射光度分析体系.阴离子交换柱(HPIC-AS3)分离水样中的NO2-和NO3-,洗脱液依次将NO2-和NO3-洗脱流经镀铜镉还原柱,NO3-在线还原为NO2-,与对氨基苯磺酸溶液和N-(1-萘基)-乙二胺溶液合并,在λmax=500 nm处对NO2-和NO3-产生的红色染料进行光度连续检测.NO2-和NO3-的线性范围分别为0.01~1.0mg/L和0.02~2.0 mg/L,检出限分别为0.004和0.008 ng/L.方法用于雨水、湖水和自来水中痕量NO2-和NO3-的同时连续测定.  相似文献   

4.
Zhengjun G  Xinshen Z  Guohe C  Xinfeng X 《Talanta》2005,66(4):1012-1017
A simple, accurate, sensitive and selective flow injection catalytic kinetic spectrophotometric method for rapid determination of trace amounts of selenium is proposed in this paper. The proposed method is based on the accelerating effect of Se(IV) on the reaction of ethexlenediamine tetrecetic acid disodium salt (EDTA) and sodium nitrate with ammonium iron(II) sulfate hexahydrate in acidic media. The absorbance intensity was registered in this reaction solution at 440 nm. The calibration graph is linear in the range of 5 × 10−9-2 × 10−7 and 2 × 10−7-2 × 10−6 g ml−1. The detection limit is 2 × 10−9 g ml−1. The relative standard deviation was 3.4% for 5 × 10−8 g ml−1 Se(IV) (n = 11), 2.7% for 5 × 10−7 g ml−1 Se(IV) (n = 11). This method is very simple, rapid and suitable for automatic and continuous analysis. The presented system has been applied successfully to determination of Se(IV) of seawater samples.  相似文献   

5.
A new rapid and sensitive FI method is reported for spectrophotometric determination of trace chromium(VI) in electroplating waste water. The method is based on the reaction of Cr(VI) with sodium diphenylamine sulfonate (DPH) in acidic medium to form a purple complex (lambda(max) = 550 nm). Under the optimized conditions, the calibration curve is linear in the range 0.04-3.8 microg ml(-1) at a sampling rate of 30 h(-1). The detection limit of the method is 0.0217 microg ml(-1), and the relative standard deviation is 1.1% for eight determinations of 2 microg ml(-1) Cr(VI). The proposed method was applied to the determination of chromium in electroplating waste water with satisfactory results.  相似文献   

6.
The method is based on spectrophotometric determination of Fe(II) and Fe(III) at a single wavelength (530 nm) with the use of a dedicated reversed-flow injection system. In the system, EDTA solution is injected into a carrier stream (HNO3) and then merged with a sample stream containing a mixture of sulfosalicylic acid and 1,10-phenanthroline as indicators. In an acid environment (pH ≅ 3) the indicators form complexes with both Fe(III) and Fe(II), but EDTA replaces sulfosalicylic acid, forming a more stable colourless complex with Fe(III), whereas Fe(II) remains in a complex with 1,10-phenenthroline. As a result, the area and minimum of the characteristic peak can be exploited as measures corresponding to the Fe(III) and Fe(II) concentrations, respectively. The analytes were not found to affect each other's signals, hence two analytical curves were constructed with the use of a set of standard solutions, each containing Fe(II) and Fe(III). Both analytes were determined in synthetic samples within the concentration ranges of 0.05–4.0 and 0.09–6.0 mg L−1, respectively, with precision less than 1.5 and 2.6% (RSD) and with accuracy less than 4.3 and 5.6% (RE). The method was applied to determination of the analytes in water samples collected from artesian wells and the results of the determination were consistent with those obtained using the ICP-OES technique.  相似文献   

7.
Flow injection analysis (FIA) procedures for the Spectrophotometric determination of phenol involving in-line concentration by solvent and sorbent extraction have been developed. The imine product formed in the reaction between phenol and 4-aminoantipyrine (4-AAP) is either extracted into chloroform (solvent extraction) or is temporarily retained on C18-modified silica material contained in a microcolumn (sorbent extraction). In the latter case two variants of detection have been used namely the Spectrophotometric measurement of the methanolic eluent containing the concentrated dye and at-column optosensing of the retained reaction product followed by methanol elution to maintain reversibility of the process. In the solvent extraction procedure a 10-fold increase of sensitivity compared to the common FIA method without extraction is achieved but no corresponding improvement in detectability is observed. Under optimized conditions the detection limit amounts to 8 μg l−1. Using sorbent extraction methodology, high concentration factors can be obtained when large sample volumes are used. The only limitation in getting correspondingly lower detection limits are an increasingly high and variable blank value with sampling volume. The detection limits obtained for measurement of the absorbance in the eluent and on-column optosensing are 11 μg l−1 and 0.4 μg l−1, respectively. A study of the extractability of various phenol derivates using both solvent and sorbent extraction revealed lower relative response rates compared to the FIA method without extraction. Phenolics that possess an additional acidic group are present in ionized form at the high pH of the assay and are not extractable at all.  相似文献   

8.
测定水中痕量Cr(Ⅵ)的电渗泵顺序注射分光光度法   总被引:4,自引:0,他引:4       下载免费PDF全文
采用电渗泵顺序注射-分光光度法对水中痕量Cr(Ⅵ)进行了测定,方法通过改变电渗泵流量,流动方向及阀注入时间,实现试剂和样品的定量注入和反应时间的控制;泵工作电压为直流200V,流量为0.45mL/min显色剂采用二苯碳酰二肼,显色剂进样时间为30s,样品进样时间为15s,反应生成的紫红色配合物在540nm处检测,该法线性范围为0.010-1.20mg/L Cr(VI),检出限为3.4μg/L,应用该法成功地进行了地表水中Cr(Ⅵ)的测定。  相似文献   

9.
For the first time, an ion chromatographic method for the simultaneous determination of the disinfection by-products bromate, chlorite, chlorate, and the so-called seven standard anions, fluoride, chloride, nitrite, sulfate, bromide, nitrate and orthophosphate is presented. The separation of the ten anions was carried out using a laboratory-made high-capacity anion-exchanger. The high capacity anion-exchanger allowed the direct injection of large sample volumes without any sample pretreatment, even in the case of hard water samples. For quantification of fluoride, chloride, nitrite, sulfate, bromide, nitrate, orthophosphate and chlorate, a conductivity detection method was applied after chemical suppression. The post-column reaction, based on chlorpromazine, was optimized for the determination of chlorite and bromate. The method detection limit for bromate measured in deionized water is 100 ng/l and for chlorite, it is 700 ng/l. In hard drinking water, the method’s detection limits are 700 ng/l (bromate) and 3.5 μg/l (chlorite). The method’s detection limits for the other eight anions, determined by conductivity detection, are between 100 μg/l (nitrite) and 1.6 mg/l (chlorate).  相似文献   

10.
A highly sensitive catalytic quenching spectrofluorimetric method was described for the determination of V(V) based on its catalytic effect on the oxidation of 1,8-diaminonaphthalene by potassium bromate with Tiron as an activator in weakly acidic medium and the reaction mechanism was investigated. The reaction was followed spectrofluorimetrically by measuring the fluorescence intensity of 1,8-diaminonathphlene (DAN) (λex=356 nm, λem=439 nm) at a fixed time of 5 min from initiation of the reaction. Under the optimum conditions, vanadium(V) can be determined in the range 0.05-50.0 ng ml−1 with a S.D.=0.024 for 15 times measurements. The detection limit of the method was down to 0.0088 ng ml−1 and the catalytic reaction activation energy was found to be 43.92 kJ mol−1. The proposed method was tested for the determination of vanadium(V) in rice and natural water samples.  相似文献   

11.
The method exploits the possibilities of flow injection gradient titration in a system of reversed flow with spectrophotometric detection. In the developed approach a small amount of titrant (EDTA) is injected into a stream of sample containing a mixture of indicators (sulfosalicylic acid and 1,10-phenanthroline). In acid environment sulfosalicylic acid forms a complex with Fe(III), whereas 1,10-phenanthroline forms a complex with Fe(II). Measurements are performed at wavelength λ = 530 nm when radiation is absorbed by both complexes. After injection EDTA replaces sulfosalicylic acid and forms with Fe(III) more stable colourless complex. As a result, a characteristic “cut off” peak is registered with a width corresponding to the Fe(III) concentration and with a height corresponding to the Fe(II) concentration. Calibration was performed by titration of four two-component standard solutions of the Fe(II)/Fe(III) concentrations established in accordance with 22 factorial plan. The method was tested with the use of synthetic samples and then it was applied to the analysis of water samples taken from artesian wells. Under optimized experimental conditions Fe(II) and Fe(III) were determined with precision less than 0.8 and 2.5% (RSD) and accuracy less than 3.2 and 5.1% (relative error) within the concentration ranges of 0.1-3.0 and 0.9-3.5 mg L−1 of both analytes, respectively.  相似文献   

12.
阐述了一种基于碱性条件下,采用还原液将硝酸盐还原为亚硝酸盐,从而实现淡水中硝酸盐的还原液-流动注射分光光度检测方法,通过优化实验确定了最优分析条件。硝酸盐浓度在50~2000μg/L范围内与峰高呈良好的线性关系,方法检出限3.5μg/L,相对标准偏差0.90%(n=15,500μg/L)。方法应用于环境水样中硝酸盐的检测,加标回收率为95.0%~100.2%。该方法避免了镉还原柱再生处理,简化了操作,易于实现无人值守式的在线自动监测。  相似文献   

13.
Vanessa G.K. Almeida 《Talanta》2007,71(3):1047-1053
This paper reports the development of a reversed flow injection system for the spectrophotometric determination of Sb(III) and total Sb in antileishmanial drugs. The analytical system is based on the selective reaction between Sb(III) and bromopyrogallol red (BPR) with the decrease of the absorbance at 555 nm. Total Sb concentration was determined after reduction of all Sb(V) to Sb(III) with KI and ascorbic acid. The influence of system variables (chemical and flow type) and the possible interference of high amounts of Sb(V) on Sb(III) was studied as well as the suitable conditions for preparation of samples. It was verified that the use of Triton X-100 enhanced the sensitivity of the methodology and that the previous sonication of the samples was fundamental to achieve accurate results. Under optimized conditions the reversed FIA system was able to process 63 samples per hour with a detection limit of 29 ng ml−1 and a R.S.D. of 3.8% (0.25 μg ml−1 level). Real samples of commercial antileishmanial drugs were analyzed, being observed no statistical difference between the results obtained by the developed system and FAAS or manual methodology in relation to total Sb concentration.  相似文献   

14.
Praus P 《Talanta》2004,62(5):977-982
An isotachophoresis (ITP)–capillary zone electrophoresis (CZE) combination was used for the determination of chlorite in drinking waters. No sample preparation is needed and no interfering by other anions in tap water was observed. The reached limits of detection with conductivity detector were 0.012–0.017 mg l−1. By four-fold sample loading with a 30 μl valve, 0.005 mg l−1 of chlorite was determined with R.S.D.=3.3%. The concentrations of 0.05 and 0.20 mg l−1 were measured with R.S.D. of 2.2 and 2.7%, respectively. The recoveries of chlorite from drinking water were 96–106% in the range of 0.02–0.20 mg l−1. The R.S.D. values of migration times (inter-day) were up to 1.3%. The time for analysis is about 15 min.  相似文献   

15.
《Analytical letters》2012,45(10):1989-1998
Abstract

A sensitive and selective spectrophotometric flow injection analysis (FIA) method with chlorophosphonazo-mN has been developed for the determination of uranium(VI) in standard ore samples. Most of interfering ions are effectively eliminated by the masking reagent of diethylenetriaminepentaacetic acid (DTPA). In the U(VI)-chlorophosphonazo-mN system, the maximum absorption wavelength is at 680 nm and Beer's law is obeyed in the range of 1 to 15 μg ml?1. The correlation coefficient of the calibration curve is 0.9998, the sampling frenquency is 60 h?1, and the detection limit for uranium(VI) is 0.5 μg ml?1. The composition of the U(VI)-chlorophosphonazo-nN complex was established to be 1:2 by flow-through spectrophotometric and conventional molar ratios methods.  相似文献   

16.
This work proposes a new procedure for on-line electro-oxidative leaching and spectrophotometric determination of uranium in ore samples. By associating a conventional flow injection system, used for uranium determination with Arsenazo III, with an on-line system for electro-oxidative leaching, a fully integrated system was assembled. The systems were integrated after achieving optimum conditions for uranium determination and leaching. According to the results obtained in the present work, a current density of 280 mA cm−2 generated enough hypochlorite ions in the electrolyte solution (3.6 mol L−1 HCl + 2% (w/v) NaCl) to promote quantitative oxidation of U(IV) to U(VI) thus improving the extraction efficiency. The slurry density did not significantly affect the performance of the system and the increasing temperature resulted in a decrease in extraction efficiency. This methodology was applied in the determination of U3O8 in four ore samples and the results obtained agreed with those obtained by ICP-MS after conventional wet acid digestion of the samples.  相似文献   

17.
在碱性条件下,佐米曲谱坦对鲁米诺-K3[Fe(CN)6]化学发光体系有较强的抑制作用,据此建立了佐米曲谱坦的流动注射化学发光分析法。该法的化学发光抑制值ΔI与佐米曲谱坦质量浓度在2.0×10-6~1.2×10-4g/mL范围内,呈良好的线性关系,检出限为7.6×10-7g/mL。对2.5×10-5g/mL佐米曲谱坦测定的相对标准偏差为1.2%(n=11)。方法适用于佐米曲谱坦片中佐米曲谱坦的测定。  相似文献   

18.
《Analytical letters》2012,45(1-3):284-297
A multisyringe flow injection system for the spectrophotometric determination of bromate in water is proposed, based on the oxidation of phenothiazine compounds by bromate in acidic medium. Several phenothiazines were tested, including chlorpromazine, trifluoperazine, and thioridazine. Higher sensitivity and lower LOD were attained for chlorpromazine. Interference from nitrite, hypochlorite, and chlorite was eliminated in-line, without any changes in the manifold. The automatic methodology using chlorpromazine allowed the determination of bromate between 25 and 750 µg L?1, with LOD of 6 µg L?1, good precision (RSD < 1.6%, n = 10), and determination frequency of 35 h?1.  相似文献   

19.
《Analytical letters》2012,45(6):949-964
Abstract

This work describes an attempt to have a flow injection analysis (FIA) system for Orciprenaline with potentiometric and spectrophotometric detectors working sequentially. The potentiometric detection was performed using an orciprenaline ion-selective electrode made of orciprenaline ion-associate with phosphotungstic acid incorporated in a PVC matrix membrane, followed by sequential spectrophotometric detection of the same sample using the reaction of orciprenaline with phosphomolybdic acid in alkaline medium and measurement at 670 nm using a USB2000 fiber-optic spectrophotometer. The method was applied and validated for the assay of different samples that are 1.0 × 10?2–1.0 × 10?7 M orciprenaline, and the recovery values for Alupent® tablets, plasma and urine sample ranged from 99.39–100.93, 99.87–100.57, and 98.83–100.64 respectively for the potentiometric detector and 99.66–100.58, 99.78–100.69 and 99.12–100.92 respectively for the sequential spectrophotometric detector. It was found that using the double detection system compensated for both the unselectivity of the spectrophotometric method and the low detection limit of the potentiometric method (6.3 × 10?4 M). Although two detectors were used in the measurements, the method is still very simple to design and apply, in addition to being rapid and less expensive than other more sophisticated techniques applied in the literature and can therefore be used for other pharmaceutical compounds as well.  相似文献   

20.
Nakano S  Tanaka E  Mizutani Y 《Talanta》2003,61(2):203-210
A highly sensitive flow-injection method is proposed for the catalytic determination of vanadium(V) at sub-nanogram per milliliter levels using a new indicator reaction. The method is based on the catalytic effect of vanadium(V) on the bromate oxidation of N,N′-bis(2-hydroxyl-3-sulfopropyl)-tolidine. 1,2-Dihydroxybenzene-3,5-disulfonate was used as an activator in the vanadium(V)-catalyzed reaction and significantly enhanced the sensitivity of the method. Vanadium(V) in the range 0.01-3.0 ng ml−1 was easily determined with sampling rate of about 30 h−1. Vanadium(IV) could be also determined. The limit of detection (S/N=3) was 0.008 ng ml−1 and the relative standard deviations were 1.4 and 1.6% for ten determinations of 0.2 ng ml−1 vanadium(IV) and vanadium(V), respectively. Interferences from metal ions could be suppressed by the addition of ethylenediamine-N,N,N′,N′-tetrakis(methylenephosphonic acid) as a masking agent. The proposed method was successfully applied to the determination of vanadium in water samples.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号