首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 25 毫秒
1.
A systematic study is presented in which multilayers of different composition (W/Si, Mo/Si, Pd/B4C), periodicity (from 2.5 to 5.5 nm) and number of layers have been characterized. In particular, the intrinsic quality (roughness and reflectivity) as well as the performance (homogeneity and coherence of the outgoing beam) as a monochromator for synchrotron radiation hard X‐ray micro‐imaging are investigated. The results indicate that the material composition is the dominating factor for the performance. By helping scientists and engineers specify the design parameters of multilayer monochromators, these results can contribute to a better exploitation of the advantages of multilayer monochromators over crystal‐based devices; i.e. larger spectral bandwidth and high photon flux density, which are particularly useful for synchrotron‐based micro‐radiography and ‐tomography.  相似文献   

2.
Advances in resonant inelastic X‐ray scattering (RIXS) have come in lockstep with improvements in energy resolution. Currently, the best energy resolution at the Ir L3‐edge stands at ~25 meV, which is achieved using a diced Si(844) spherical crystal analyzer. However, spherical analyzers are limited by their intrinsic reflection width. A novel analyzer system using multiple flat crystals provides a promising way to overcome this limitation. For the present design, an energy resolution at or below 10 meV was selected. Recognizing that the angular acceptance of flat crystals is severely limited, a collimating element is essential to achieve the necessary solid‐angle acceptance. For this purpose, a laterally graded, parabolic, multilayer Montel mirror was designed for use at the Ir L3‐absorption edge. It provides an acceptance larger than 10 mrad, collimating the reflected X‐ray beam to smaller than 100 µrad, in both vertical and horizontal directions. The performance of this mirror was studied at beamline 27‐ID at the Advanced Photon Source. X‐rays from a diamond (111) monochromator illuminated a scattering source of diameter 5 µm, generating an incident beam on the mirror with a well determined divergence of 40 mrad. A flat Si(111) crystal after the mirror served as the divergence analyzer. From X‐ray measurements, ray‐tracing simulations and optical metrology results, it was established that the Montel mirror satisfied the specifications of angular acceptance and collimation quality necessary for a high‐resolution RIXS multi‐crystal analyzer system.  相似文献   

3.
A quantitative analysis of the crucial characteristics of currently used and promising materials for X‐ray refractive optics is performed in the extended energy range 8–100 keV. According to the examined parameters, beryllium is the material of choice for X‐ray compound refractive lenses (CRLs) in the energy range 8–25 keV. At higher energies the use of CRLs made of diamond and the cubic phase of boron nitride (c‐BN) is beneficial. It was demonstrated that the presence of the elements of the fourth (or higher) period has a fatal effect on the functional X‐ray properties even if low‐Z elements dominate in the compound, like in YB66. Macroscopic properties are discussed: much higher melting points and thermal conductivities of C and c‐BN enable them to be used at the new generation of synchrotron radiation sources and X‐ray free‐electron lasers. The role of crystal and internal structure is discussed: materials with high density are preferable for refractive applications while less dense phases are suitable for X‐ray windows. Single‐crystal or amorphous glass‐like materials based on Li, Be, B or C that are free of diffuse scattering from grain boundaries, voids and inclusions are the best candidates for applications of highly coherent X‐ray beams.  相似文献   

4.
A microelectromechanical‐systems‐based calorimeter designed for use on a synchrotron nano‐focused X‐ray beamline is described. This instrument allows quantitative DC and AC calorimetric measurements over a broad range of heating/cooling rates (≤100000 K s?1) and temperature modulation frequencies (≤1 kHz). The calorimeter was used for high‐resolution thermal imaging of nanogram‐sized samples subjected to X‐ray‐induced heating. For a 46 ng indium particle, the measured temperature rise reaches ~0.2 K, and is directly correlated to the X‐ray absorption. Thermal imaging can be useful for studies of heterogeneous materials exhibiting physical and/or chemical transformations. Moreover, the technique can be extended to three‐dimensional thermal nanotomography.  相似文献   

5.
The first application of a pnCCD detector for X‐ray scattering experiments using white synchrotron radiation at BESSY II is presented. A Cd arachidate multilayer was investigated in reflection geometry within the energy range 7 keV < E < 35 keV. At fixed angle of incidence the two‐dimensional diffraction pattern containing several multilayer Bragg peaks and respective diffuse‐resonant Bragg sheets were observed. Since every pixel of the detector is able to determine the energy of every incoming photon with a resolution ΔE/E? 10?2, a three‐dimensional dataset is finally obtained. In order to achieve this energy resolution the detector was operated in the so‐called single‐photon‐counting mode. A full dataset was evaluated taking into account all photons recorded within 105 detector frames at a readout rate of 200 Hz. By representing the data in reciprocal‐space coordinates, it becomes obvious that this experiment with the pnCCD detector provides the same information as that obtained by combining a large number of monochromatic scattering experiments using conventional area detectors.  相似文献   

6.
7.
A spectrometer for resonant inelastic X‐ray scattering (RIXS) is proposed where imaging and dispersion actions in two orthogonal planes are combined to deliver a full two‐dimensional map of RIXS intensity in one shot with parallel detection at incoming hvin and outgoing hvout photon energies. Preliminary ray‐tracing simulations with a typical undulator beamline demonstrate a resolving power well above 11000 with both hvin and hvout near 930 eV, with a vast potential for improvement. Combining this instrument – nicknamed hv2 spectrometer – with an X‐ray free‐electron laser source simplifies its technical implementation and enables efficient time‐resolved RIXS experiments.  相似文献   

8.
A new system of slits called `spiderweb slits' have been developed for depth‐resolved powder or polycrystalline X‐ray diffraction measurements. The slits act on diffracted X‐rays to select a particular gauge volume of sample, while absorbing diffracted X‐rays from outside of this volume. Although the slit geometry is to some extent similar to that of previously developed conical slits or spiral slits, this new design has advantages over the previous ones in use for complex heterogeneous materials and in situ and operando diffraction measurements. For example, the slits can measure a majority of any diffraction cone for any polycrystalline material, over a continuous range of diffraction angles, and work for X‐ray energies of tens to hundreds of kiloelectronvolts. The design is generated and optimized using ray‐tracing simulations, and fabricated through laser micromachining. The first prototype was successfully tested at the X17A beamline at the National Synchrotron Light Source, and shows similar performance to simulations, demonstrating gauge volume selection for standard powders, for all diffraction peaks over angles of 2–10°. A similar, but improved, design will be implemented at the X‐ray Powder Diffraction beamline at the National Synchrotron Light Source II.  相似文献   

9.
Core–shell X‐ray emission spectroscopy (XES) is a valuable complement to X‐ray absorption spectroscopy (XAS) techniques. However, XES in the hard X‐ray regime is much less frequently employed than XAS, often as a consequence of the relative scarcity of XES instrumentation having energy resolutions comparable with the relevant core‐hole lifetimes. To address this, a family of inexpensive and easily operated short‐working‐distance X‐ray emission spectrometers has been developed. The use of computer‐aided design and rapid prototype machining of plastics allows customization for various emission lines having energies from ~3 keV to ~10 keV. The specific instrument described here, based on a coarsely diced approximant of the Johansson optic, is intended to study volume collapse in Pr metal and compounds by observing the pressure dependence of the Pr Lα emission spectrum. The collection solid angle is ~50 msr, roughly equivalent to that of six traditional spherically bent crystal analyzers. The miniature X‐ray emission spectrometer (miniXES) methodology will help encourage the adoption and broad application of high‐resolution XES capabilities at hard X‐ray synchrotron facilities.  相似文献   

10.
A new set‐up is presented to measure element‐selective magnetization dynamics using the ALICE chamber [Grabis et al. (2003), Rev. Sci. Instrum. 74 , 4048–4051] at the BESSY II synchrotron at the Helmholtz‐Zentrum Berlin. A magnetic‐field pulse serves as excitation, and the magnetization precession is probed by element‐selective X‐ray resonant magnetic scattering. With the use of single‐bunch‐generated X‐rays a temporal resolution well below 100 ps is reached. The ALICE diffractometer environment enables investigations of thin films, described here, multilayers and laterally structured samples in reflection or diffuse scattering geometry. The combination of the time‐resolved set‐up with a cryostat in the ALICE chamber will allow temperature‐dependent studies of precessional magnetization dynamics and of damping constants to be conducted over a large temperature range and for a large variety of systems in reflection geometry.  相似文献   

11.
In this paper the choice between bending magnets and insertion devices as sample illuminators for a hard X‐ray full‐field microscope is investigated. An optimized bending‐magnet beamline design is presented. Its imaging speed is very competitive with the performance of similar microscopes installed currently at insertion‐device beamlines. The fact that imaging X‐ray microscopes can accept a large phase space makes them very well suited to the output characteristics of bending magnets which are often a plentiful and paid‐for resource. There exist opportunities at all synchrotron light sources to take advantage of this finding to build bending‐magnet beamlines that are dedicated to transmission X‐ray microscope facilities. It is expected that demand for such facilities will increase as three‐dimensional tomography becomes routine and advanced techniques such as mosaic tomography and XANES tomography (taking three‐dimensional tomograms at different energies to highlight elemental and chemical differences) become more widespread.  相似文献   

12.
X‐ray magnetic circular dichroism (XMCD) has become in recent years an outstanding tool for studying magnetism. Its element specificity, inherent to core‐level spectroscopy, combined with the application of magneto‐optical sum rules allows quantitative magnetic measurements at the atomic level. These capabilities are now incorporated as a standard tool for studying the localized magnetism in many systems. However, the application of XMCD to the study of the conduction‐band magnetism is not so straightforward. Here, it is shown that the atomic selectivity is not lost when XMCD probes the delocalized states. On the contrary, it provides a direct way of disentangling the magnetic contributions to the conduction band coming from the different elements in the material. This is demonstrated by monitoring the temperature dependence of the XMCD spectra recorded at the rare‐earth L2‐edge in the case of RT2 (R = rare‐earth, T = 3d transition metal) materials. These results open the possibility of performing element‐specific magnetometry by using a single X‐ray absorption edge.  相似文献   

13.
In the development of full‐field transmission X‐ray microscopy for basic study in science and technology, a condenser capable of providing intense illumination with high uniformity and stability on tested specimens in order to achieve high‐quality images is essential. The latest design of a square‐shaped condenser based on diffractive gratings has demonstrated promising uniformity in illumination. This paper describes in more detail the development of such a beam shaper for hard X‐rays at 10 keV with regard to its design, manufacture and optical characterization. The effect of the grating profile on the diffracted intensity has been theoretically predicted by numerical simulation using the finite‐difference time‐domain method. Based on this, the limitations of the grating‐based condenser are discussed.  相似文献   

14.
Thermal treatment of mineral ores such as ilmenite can initiate phase transformations that could affect their activation or deactivation, subsequently influencing their ability to dissolve in a leaching agent. Most laboratory‐based X‐ray diffraction (XRD) studies were carried out ex situ in which realistic diffraction patterns could not be obtained simultaneously with occurring reactions and were time‐consuming. The availability of synchrotron‐radiation‐based XRD not only allows in situ analysis, but significantly shortens the data recording time. The present study details the design of a robust high‐temperature microfurnace which allows thermal processing of mineral ore samples and the simultaneous collection of high‐resolution synchrotron XRD data. In addition, the application of the manufactured microfurnace for in situ study of phase transformations of ilmenite ore under reducing conditions is demonstrated.  相似文献   

15.
An in‐vacuum undulator (IVU) with a tapered configuration was installed in the 8C nanoprobe/XAFS beamlime (BL8C) of the Pohang Light Source in Korea for hard X‐ray nanoprobe and X‐ray absorption fine‐structure (XAFS) experiments. It has been operated in planar mode for the nanoprobe experiments, while gap‐scan and tapered modes have been used alternatively for XAFS experiments. To examine the features of the BL8C IVU for XAFS experiments, spectral distributions were obtained theoretically and experimentally as functions of the gap and gap taper. Beam profiles at a cross section of the X‐ray beam were acquired using a slit to visualize the intensity distributions which depend on the gap, degree of tapering and harmonic energies. To demonstrate the effect of tapering around the lower limit of the third‐harmonic energy, V K‐edge XAFS spectra were obtained in each mode. Owing to the large X‐ray intensity variation around this energy, XAFS spectra of the planar and gap‐scan modes show considerable spectral distortions in comparison with the tapered mode. This indicates that the tapered mode, owing to the smooth X‐ray intensity profile at the expense of the highest and most stable intensity, can be an alternative for XAFS experiments where the gap‐scan mode gives a considerable intensity variation; it is also suitable for quick‐XAFS scanning.  相似文献   

16.
A molded‐loose‐powder technique using a small powdered sample (100 mg) was developed for the X‐ray fluorescence analysis of 22 components (Na2O, MgO, Al2O3, SiO2, P2O5, K2O, CaO, TiO2, MnO, Fe2O3, V, Cr, Ni, Cu, Zn, Rb, Sr, Y, Zr, Nb, Ba, and Pb) in ancient pottery. This loose powder specimen was prepared by pressing the small powdered sample into a sample holder, formed from a stainless steel disk (48‐mm diameter × 0.8‐mm height) with a hole (11‐mm diameter), by hand. Calibration standards were prepared by homogenizing chemical reagents containing these 22 analytes using the concentration ranges of 166 ancient potteries and three clay materials from Japan. The calibration curves of these benchmark mixtures exhibited a good linearity (correlation coefficient, r = 0.990–1.000), accuracy, and reproducibility compared with those of other synthesized specimens and three reference standards. The lower limits of detection were less than tens of mg kg?1 (e.g., 94 mg kg?1 for Na2O, 11 mg kg?1 for P2O5, 1.1 mg kg?1 for Rb, and 0.9 mg kg?1 for Y). Using the present method, we determined 22 components in two prehistoric potteries from Japan. The advantage of this method is that only a small amount of sample is required, which can be prepared easily and rapidly and reused for other analyses. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

17.
A novel set‐up has been designed and used for synchrotron radiation X‐ray high‐resolution powder diffraction (SR‐HRPD) in transmission geometry (spinning capillary) for in situ solid–gas reactions and processes in an isobaric and isothermal environment. The pressure and temperature of the sample are controlled from 10?3 to 1000 mbar and from 80 to 1000 K, respectively. To test the capacities of this novel experimental set‐up, structure deformation in the porous material zeolitic imidazole framework (ZIF‐8) by gas adsorption at cryogenic temperature has been studied under isothermal and isobaric conditions. Direct structure deformations by the adsorption of Ar and N2 gases have been observed in situ, demonstrating that this set‐up is perfectly suitable for direct structural analysis under in operando conditions. The presented results prove the feasibility of this novel experimental station for the characterization in real time of solid–gas reactions and other solid–gas processes by SR‐HRPD.  相似文献   

18.
Total scattering from nanocrystalline materials recorded on the Australian Synchrotron powder diffraction beamline has been analysed to produce atomic pair distribution functions (PDFs) for structural analysis. The capability of this beamline, which uses the massively parallel Mythen II detector, has been quantified with respect to PDF structure analysis. Data were recorded to a wavevector magnitude, Q, of 20.5 Å?1, with successful PDFs obtained for counting times as short as 10 s for crystalline LaB6 and 180 s for nanocrystalline (47 Å) anatase. This paper describes the aspects of a PDF experiment that are crucial to its success, with reference to the outcomes of analysis of data collected from nanocrystalline TiO2 and microcrystalline LaB6 and IrO2.  相似文献   

19.
The effects of varying LiPF6 salt concentration and the presence of lithium bis(oxalate)borate additive on the electronic structure of commonly used lithium‐ion battery electrolyte solvents (ethylene carbonate–dimethyl carbonate and propylene carbonate) have been investigated. X‐ray Raman scattering spectroscopy (a non‐resonant inelastic X‐ray scattering method) was utilized together with a closed‐circle flow cell. Carbon and oxygen K‐edges provide characteristic information on the electronic structure of the electrolyte solutions, which are sensitive to local chemistry. Higher Li+ ion concentration in the solvent manifests itself as a blue‐shift of both the π* feature in the carbon edge and the carbonyl π* feature in the oxygen edge. While these oxygen K‐edge results agree with previous soft X‐ray absorption studies on LiBF4 salt concentration in propylene carbonate, carbon K‐edge spectra reveal a shift in energy, which can be explained with differing ionic conductivities of the electrolyte solutions.  相似文献   

20.
Newtonian fluid dynamics simulations were performed using the Navier–Stokes–Fourier formulations to elucidate the short time‐scale (µs and longer) evolution of the density and temperature distributions in an argon‐gas‐filled attenuator for an X‐ray free‐electron laser under high‐repetition‐rate operation. Both hydrodynamic motions of the gas molecules and thermal conductions were included in a finite‐volume calculation. It was found that the hydrodynamic wave motions play the primary role in creating a density depression (also known as a filament) by advectively transporting gas particles away from the X‐ray laser–gas interaction region, where large pressure and temperature gradients have been built upon the initial energy deposition via X‐ray photoelectric absorption and subsequent thermalization. Concurrent outward heat conduction tends to reduce the pressure in the filament core region, generating a counter gas flow to backfill the filament, but on an initially slower time scale. If the inter‐pulse separation is sufficiently short so the filament cannot recover, the depth of the filament progressively increases as the trailing pulses remove additional gas particles. Since the rate of hydrodynamic removal decreases while the rate of heat conduction back flow increases as time elapses, the two competing mechanisms ultimately reach a dynamic balance, establishing a repeating pattern for each pulse cycle. By performing simulations at higher repetition rates but lower per pulse energies while maintaining a constant time‐averaged power, the amplitude of the hydrodynamic motion per pulse becomes smaller, and the evolution of the temperature and density distributions approach asymptotically towards, as expected, those calculated for a continuous‐wave input of the equivalent power.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号