首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Summary Total-reflection X-ray fluorescence (TXRF) and inductively coupled plasma mass spectrometry (ICP-MS) were used for the analysis of two biological reference materials. The quantifications were carried out after addition of one single standard element which serves as an internal standard in both cases. The results of TXRF analysis were good to satisfactory. The method is therefore suitable for fast multielement analysis, because it needs no special calibration specimens. The results of ICP-MS analysis are at least in the order of magnitude of the certified values. In some cases recoveries fit very well. For quantitative analysis, however, the use of the standard addition method or the calibration with external standards is required.  相似文献   

2.
A calibration method has been developed which is realised in the flow injection analysis (FIA) by the gradient technique. According to this method two transient peaks, one for a sample and the other for a sample with standard addition, are recorded and compared point by point in the entire defined time range. The analytical result is estimated on the basis of information gained about the local analyte concentrations in the sample zone. The method allows the results to be reliable when both the non-linear calibration dependence and the interference effect occur. As an example, calcium in synthetic samples containing silicon, phosphate, aluminium, vanadium and titanium, and also in iron ore sample, were determined by flame atomic absorption spectrometry (FAAS). It has been proved, that the method can be effective in overcoming even extremely strong interferences, providing analytical results with average accuracy equal to ca. 5% and with precision 2–3 times inferior to that obtained by conventional FI calibration.  相似文献   

3.
The analytical performances of coupled hydride generation, integrated atom trap (HG-IAT) atomizer flame atomic absorption spectrometry (FAAS) systems were evaluated for determination of As and Se in biological and environmental reference materials. Arsenic and Se hydrides are atomized in air-acetylene flame-heated IAT. A new design of HG-IAT-FAAS hyphenated technique that would exceed the operational capabilities of existing arrangements (a water-cooled single silica tube, double-slotted quartz tube or an "integrated trap") was investigated. A dramatic improvement in detection limit was achieved compared with that obtained using anyone of the above atom trapping techniques separately. The concentration detection limits were 4 and 3 ng ml(-1) for As and Se, respectively. For a 2 min in situ preconcentration time, sensitivity enhancement, compared to FAAS, were 875 and 833 folds for As and Se, respectively, using hydride generation, atom trapping technique. The sensitivity can be further improved by increasing the collection time. The relative standard deviations (RSDs) are of the order of 5 - 9% for this hyphenated technique. The designs studied include slotted tube, water-cooled single silica tube and integrated atom trap. The accuracy was assessed by analyses of NRCC DOLT-2 (Dogfish Liver) and NIST SRM 1648 (Urban Particulate Matter) reference materials. The measured As and Se contents in two reference materials were in satisfactory agreement with the certified values.  相似文献   

4.
Nikolai Alov 《Analytical letters》2018,51(11):1789-1795
Novel rapid determination of copper-zinc ore elemental composition by total reflection X-ray fluorescence (TXRF) is proposed. Approaches for solid state sample analysis by TXRF are provided. The sample preparation is chosen to obtain the suspensions in ethylene glycol. The optimum suspension preparation conditions (sample mass, volume of dispersion medium) and the measurement conditions (internal standard element, spectra acquisition time) were determined. The sedimentation stability of suspensions was studied. It was found that the suspensions remain stable for approximately 2?min, which is sufficiently long for the sampling the suspension. The proposed technique allows determining the elemental composition of solid ore samples without sample digestion. The sample preparation time takes approximately 20?min. The relative standard deviation of the analytical results did not exceed 10%.  相似文献   

5.
The contents of Cl, Ca, K, Ti, V, Cr, Mn, Fe, Ni, Cu, Zn, As, Se, Rb, Sr, Ba and Pb in raw coal fly ash from five Bulgarian power plants were determined by total reflection X-ray fluorescence (TXRF), using gallium as the internal standard. The samples were analysed as in slurry form in Triton? X-114. The experimental parameters, such as grain size, concentrations of fly ash slurry and excitation time were optimised. For validation of the method, the certified reference material BCR-176R fly ash was used. The precision of the results obtained is characterised by a relative standard deviation of approximately 10%. The resulting data confirm the suitability of TXRF for the simultaneous determination of major, minor and trace elements in coal fly ash samples. Further advantages provided by TXRF are easy sample preparation (no sample dissolution) and the small sample amount required for analysis.  相似文献   

6.
An inductively coupled plasma mass spectrometric (ICP-MS) procedure has been developed for the determination of trace elements in wine. The procedure consists in simple 1+1 dilution of the wine and semi-quantitative analysis (without external calibration) using In as internal standard. Thirty-one elements at concentrations ranging from 0.1 mg mL(-1) to 0.5 ng mL(-1) can be determined by ICP-MS analysis with and without digestion. It was investigated whether a matrix effect observed for EtOH in the wine matrix can be overcome by application of a micro-concentric nebulizer with a membrane desolvator (MCN 6000). The results obtained for the MCN 6000 are compared with those obtained by use of a conventional Meinhard nebulizer. It is shown that the observed matrix effect can only be compensated by use of an internal standard for the Meinhard nebulizer, but not for the MCN 6000. Results for ICP-MS are compared with those obtained by total reflection X-ray fluorescence spectrometry (TXRF).  相似文献   

7.
A study regarding uranium determination in seawater by total reflection X-ray fluorescence (TXRF) spectrometry is reported. Uranium, present in seawater in concentration of about 3.3 ng/mL, was selectively extracted in diethyl ether and determined by TXRF after its preconcentration by evaporation and subsequent dissolution in a small volume of 1.5% suprapure HNO3. Yttrium was used as an internal standard. Before using diethyl ether for selective extraction of uranium from seawater, its extraction behavior for different elements was studied using a multielement standard solution having elemental concentrations in 5 ng/mL levels. It was observed that the extraction efficiency of diethyl ether for uranium was about 100% whereas for other elements it was negligible. The detection limit of TXRF method for uranium in seawater samples after pre-concentration step approaches to 67 pg/mL. The concentrations of uranium in seawater samples determined by TXRF are in good agreement with the values reported in the literature. The method shows a precision within 5% (1σ). The study reveals that TXRF can be used as a fast analytical technique for the determination of uranium in seawater.  相似文献   

8.
A chemical microchip, which has a flat region on the surface, was recently designed for total reflection X-ray fluorescence (TXRF) analysis. A sample solution was introduced from an inlet by a microsyringe and flowed into a microchannel. Finally it overflowed from the well-type microchannel on the flat region. The sample solution on this region was dried, and then measured by TXRF. The TXRF spectra could be measured with a low background level. This preliminary result indicated that the edge of the well-type channel would not cause a serious problem for TXRF analysis. In addition, a good linear relationship was obtained for Zn Kα in Zn standard solution. This suggests that quantitative analysis by TXRF is feasible in combination with a chemical microchip.  相似文献   

9.
Total reflection X-ray fluorescence spectrometry (TXRF) is presented as a genuine surface analytical technique. Its low information depth is shown to be the characteristic feature differentiating it from other energy dispersive X-ray fluorescence methods used for layer and surface analysis. The surface sensitivity of TXRF and its analytical capability together with the limitations of the technique are discussed here using typical applications including the contamination control of silicon wafers, thin layer analysis and trace element determination. For buried interfaces and implantation depth profiles in silicon a combination of TXRF and other techniques has been applied successfully. The TXRF method has the particular advantage of being calibrated without the need for standards. This feature is demonstrated for the example of the element arsenic.  相似文献   

10.
Total reflection X-ray fluorescence (TXRF) analysis after the separation of matrix element was studied for the determination of trace impurity elements (Ca, Sc, V, Cr, Mn, Fe, Co, Ni and Zn) in high purity copper. Matrix copper was removed by electrolysis (0.2 A, 8 h) of a nitric acid solution. A 10 μL aliquot of the remaining solution of the electrolysis was dropped on a silicon-wafer sample-carrier and dried in a vacuum. This was repeated five times and the precipitate of five 10 μL-aliquots was analyzed by TXRF using a W-Lβ beam with an incident angle of 0.05?°. TXRF analytical values were obtained by using relative sensitivity factors of the analytes to the internal standard element (Pd). Detection limits of the analytes ranges from 0.077 ng for Zn to 0.785 ng for Ca.  相似文献   

11.
Optimisation of total-reflection X-ray fluorescence for aerosol analysis   总被引:1,自引:0,他引:1  
The capabilities of total-reflection X-ray fluorescence (TXRF) analysis were investigated to develop an efficient, simple, rapid and low cost analytical method for aerosols. The technique involves direct impaction of airborne particulate matter on the quartz sample-reflector discs for TXRF. Special attention was paid to bounce-off effects, and hence the aerosol size distributions for the impactor stages; influence of siliconizing the quartz discs on the adhesion of particles; choice of the internal standard; local distribution of the material deposited on the quartz disc; and alternative materials for aerosol collection. Moreover, the proposed method could be used in combination with a one-stage impactor for total aerosol mass collection and analysis.  相似文献   

12.
An inductively coupled plasma mass spectrometric (ICP–MS) procedure has been developed for the determination of trace elements in wine. The procedure consists in simple 1+1 dilution of the wine and semi-quantitative analysis (without external calibration) using In as internal standard. Thirty-one elements at concentrations ranging from 0.1 mg mL–1 to 0.5 ng mL–1 can be determined by ICP–MS analysis with and without digestion. It was investigated whether a matrix effect observed for EtOH in the wine matrix can be overcome by application of a micro-concentric nebulizer with a membrane desolvator (MCN 6000). The results obtained for the MCN 6000 are compared with those obtained by use of a conventional Meinhard nebulizer. It is shown that the observed matrix effect can only be compensated by use of an internal standard for the Meinhard nebulizer, but not for the MCN 6000. Results for ICP–MS are compared with those obtained by total reflection X-ray fluorescence spectrometry (TXRF).  相似文献   

13.
Oolong tea from the Fujian Province is very popular at home and abroad, especially in Taiwan and Southeast Asia. In order to elucidate the possibilities to compensate the need state of people to essential elements by the national drink,a set of samples of oolong tea from the Fujian Province were analyzed by total reflection X-ray fluorescence (TXRF), a fairly new efficient method in the field of multielement analysis. After addition of a single internal standard element (e.g. gallium) to a solution of tea leaves digested by acid or to an acidified tea infusion, a portion of 5 μ1 was dried on a sample carrier and then analyzed by TXRF.  相似文献   

14.
《Analytical letters》2012,45(9):1571-1578
Abstract

The present paper describes the evaluation and application of internal standard for the determination of copper in fruit juices, employing Fast Sequential Flame Atomic Absorption Spectrometry (FS FAAS). The internal standards tested were indium, cobalt, and nickel using correlation graphs. However, indium was used, considering the composition of the samples. After this step, copper was determined in fruit juices using indium as internal standard. This method allows the determination of copper with a limit of quantification of 0.011 mg L?1. The fruit juice samples selected for analysis were of grape, orange, pineapple, peach, cashew, and strawberry. The contents of copper in these samples varied from 0.02 to 0.42 mg L?1. The analytical results were compared with the results obtained by analysis of these samples after complete mineralization using acid digestion and determination employing FS FAAS. The statistical comparison by a t-test (95% confidence level) showed no significant difference between the results. The relative standard deviations (RSD) with and without the use of the internal standard for a copper solution containing 0.4 mg L?1 were of 0.62 and 1.94%, respectively. The use of indium as internal standard provided more accurate analytical results, as well as better analytical performance for the determination of copper in juice samples.  相似文献   

15.
In this study, a fast and simple method is proposed for determination of arsenic in wine employing inductively coupled plasma atomic emission spectroscopy and internal standard technique. First Co, Bi, V and Y were evaluated as internal standards to minimize transport interferences. All samples and reference solutions were automatically spiked by autosampler, eliminating the need for manual dilutions. The result demonstrated that vanadium can be used as an internal standard. The experimental parameters (plasma power and nebulization flow rate) were optimized. The relative standard deviations (R.S.D) of measurements varied from 1.1 to 6.0% and 3.2 to 8.7% (n = 12) with and without internal standardization, respectively. Recoveries in the 95-103% range for As spiked samples were obtained.  相似文献   

16.
建立了微波消解前处理,全反射X射线荧光法(TXRF)同时测定松花粉中K、Ca、Ti、Mn、Fe、Ni、Cu、Zn和Rb9种生命元素含量的分析方法.松花粉原料经过微波消解前处理后,采用全反射X射线荧光光谱净计数、QXAS分析软件解谱和单一内标法进行定量分析.比较了干灰化法、湿消解法和微波消解法3种前处理方法的效果,并确立微波消解法作为样品前处理方法.用微波消解- TXRF法测定了花粉标准物质中的上述9种元素,并计算得到其仪器检出限(LLD)为0.002~0.054 mg/L,方法检出限(LDM)为0.004~0.122 mg/kg.TXRF法测定各元素的相对标准偏差(RSDs)为1.0%~5.5%.该方法操作简单、样品用量少、检出限低,对实际样品松花粉的测定结果与ICP - MS法无显著性差异.  相似文献   

17.
Total reflection X-ray fluorescence (TXRF) analysis after the separation of matrix element was studied for the determination of trace impurity elements (Ca, Sc, V, Cr, Mn, Fe, Co, Ni and Zn) in high purity copper. Matrix copper was removed by electrolysis (0.2 A, 8 h) of a nitric acid solution. A 10 μL aliquot of the remaining solution of the electrolysis was dropped on a silicon-wafer sample-carrier and dried in a vacuum. This was repeated five times and the precipitate of five 10 μL-aliquots was analyzed by TXRF using a W-Lβ beam with an incident angle of 0.05 °. TXRF analytical values were obtained by using relative sensitivity factors of the analytes to the internal standard element (Pd). Detection limits of the analytes ranges from 0.077 ng for Zn to 0.785 ng for Ca. Received: 25 December 1997 / Revised: 30 March 1998 / Accepted: 2 April 1998  相似文献   

18.
The method of using the Compton peak as internal standard in total reflection X-ray fluorescence (TXRF) determination is established for trace element determination of Fe, Cu, Zn, Se and Pt in human serum and of Cu and Zn in homogenized brain samples. A new method of spectrometer sensitivity calibration using spiked matrices with known amounts of trace elements is tested against established methods of matrix matching as well as internal element addition. The analytical results with the proposed procedure are compared to a certified international standard and to values with Atomic Absorption Spectrometry (AAS) obtaining analytical results of comparable accuracy and precision. The method is adequate for routine clinical analysis as it has the advantages of requiring very small amounts of material and simple preparations, which avoids the chemical digestion stage.  相似文献   

19.
The analytical performance of coupled volatile species generation-integrated atom trap (VSG-IAT) atomizer flame atomic absorption spectrometry (FAAS) system was evaluated for determination of Cd and Pb in reference materials. Lead using formation of PbH4 and Cd0 vapors are atomized in air-acetylene flame-heated IAT. A new design of VSG-IAT-FAAS hyphenated technique that would exceed the operational capabilities of existing arrangements (a water-cooled single silica tube, double-slotted quartz tube or an “integrated trap”) was investigated. A dramatic improvement in detection limit was achieved compared with that obtained using either of the above atom trapping techniques separately. The concentration detection limits, defined as 3 times the blank standard deviation (3σ), were 0.05 and 0.40 ng mL− 1 for Cd and Pb, respectively. For a 120 s in situ pre-concentration time, sensitivity enhancement compared to flame AAS, was 500 and 575 folds for Cd and Pb, respectively, using volatile species generation-atom trapping technique. The sensitivity can be further improved by increasing the collection time. The precision, expressed as RSD, was 4.4% and 4.1% (n = 6) for Cd and Pb, respectively. The designs studied include slotted tube, single silica tube and integrated atom trap-cooled atom traps. The accuracy of method was verified using certified reference materials (PLANTS 3 and IAEA/W-4) by standard addition calibration technique. The measured Cd and Pb contents in two reference materials were in satisfactory agreement with the certified values.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号