Here, we describe a novel method utilizing double stable isotope ultra performance liquid chromatography-tandem mass spectrometry to measure tissue contents and activity of phenylethanolamine N-methyltransferase (PNMT), the enzyme responsible for synthesis of the stress hormone, epinephrine. The method is based on measurement of deuterium-labeled epinephrine produced from the reaction of norepinephrine with deuterium-labeled S-adenosyl-l-methionine as the methyl donor. In addition to enzyme activity, the method allows for determination of tissue contents of PNMT using human recombinant enzyme for calibration. The calibration curve for epinephrine was linear over the range of 0.1 to 5,000 pM, with 0.5 pM epinephrine representing the lower limit of quantification. The calibration curve relating PNMT to production of deuterium-labeled epinephrine was also linear from 0.01 to 100 ng PNMT. Intra- and inter-assay coefficients of variation were respectively 12.8 % (n?=?10) and 10.9 to 13.6 % (n?=?10). We established utility of the method by showing induction of the enzyme by dexamethasone in mouse pheochromocytoma cells and strong relationships to PNMT gene expression and tissue epinephrine levels in human pheochromocytomas. Development of this assay provides new possibilities for investigations focusing on regulation of PNMT, the crucial final enzyme responsible for synthesis of epinephrine, the primary fight-or-flight stress hormone.
Figure
Assay principle of double stale isotope UPLC-MS/MS quantification of tissue content and activity of PNMT  相似文献   

2.
We describe a method for the determination of inorganic selenium in water samples via gas-phase chemiluminescence (GPCL). Se(IV) was first derivatized with 4-nitro-o-phenylenediamine to form 5-nitropiazselenol. The latter was decomposed by persulfate through photocatalytic oxidation to give Se(VI), which was reduced to Se(IV). Selenium hydride was generated from Se(IV) through reduction with sodium borohydride and then preconcentrated using cryotrapping. The cryotrapped hydride was evaporated and carried to a reaction chamber by a stream of helium, where it produced GPCL as a result of ozonation. The method exhibits a wide linear calibration range (from 0.5?μg?L?1 to 1.0?mg?L?1) with a detection limit of 0.12?μg?L?1 (for n?=?11), and a relative standard deviation of 3.90?% (at n?=?11) at 5.0?μg?L?1 level of selenium. The method was applied to the determination of inorganic selenium in water samples and gave satisfactory results.
Figure
A GPCL detection system is developed for the determination of inorganic selenium in water samples. By using analytical technique in this figure, such as derivatization, UV/ S2O 8 2- decomposition, stopped-flow injection and cryotrapping, the system can separate and preconcentrate the analyte from the matrix, then produce GPCL as a result of ozonation. The method was simple, sensitive with low-cost instrumentation.  相似文献   

3.
We report on a combination of magnetic solid-phase extraction and spectrophotometric determination of bromate. Cetyltrimethylammonium ion was adsorbed on the surface of phenyl-functionalized silica-coated Fe3O4 nanoparticles (Ph-SiO2@Fe3O4), and these materials served as the sorbent. The effects of surfactant and amount of sorbent, the composition of the desorption solution, the extraction time and temperature were optimized. Under optimized conditions, an enrichment factor of 12 was achieved, and the relative standard deviation is 2.9 % (for n?=?5). The calibration plot covers the 1–50 ng mL?1 range with reasonable linearity (r 2?>?0.998); and the limit of detection is 0.5 ng mL?1. The method is not interfered by ionic compounds commonly found in environmental water samples. It was successfully applied to the determination of bromate in spiked water samples.
Figure
Extraction of bromate ions using surfactant-coated phenyl functionalized Fe3O4 magnetic nanoparticles followed by spectrophotometric detection.  相似文献   

4.
We have recently developed a multiplex mass spectrometry imaging (MSI) method which incorporates high mass resolution imaging and MS/MS and MS3 imaging of several compounds in a single data acquisition utilizing a hybrid linear ion trap-Orbitrap mass spectrometer (Perdian and Lee, Anal. Chem. 82, 9393–9400, 2010). Here we extend this capability to obtain positive and negative ion MS and MS/MS spectra in a single MS imaging experiment through polarity switching within spiral steps of each raster step. This methodology was demonstrated for the analysis of various lipid class compounds in a section of mouse brain. This allows for simultaneous imaging of compounds that are readily ionized in positive mode (e.g., phosphatidylcholines and sphingomyelins) and those that are readily ionized in negative mode (e.g., sulfatides, phosphatidylinositols and phosphatidylserines). MS/MS imaging was also performed for a few compounds in both positive and negative ion mode within the same experimental set-up. Insufficient stabilization time for the Orbitrap high voltage leads to slight deviations in observed masses, but these deviations are systematic and were easily corrected with a two-point calibration to background ions.
Figure
?  相似文献   

5.
We report on a simple, sensitive and reliable method for the cloud point extraction of antimony (Sb) and its subsequent spectrophotometric detection. It is based on the color reaction of Sb (III) with iodide in acidic medium and subsequent micelle-mediated extraction of tetraiodoantimonate using a non-ionic surfactant in the absence of any chelating agent. The effects of reaction and extraction parameters were optimized. The calibration plot is linear in the range of 0.80–95?ng?mL?1 of antimony in the sample solution, with a regression coefficient (r) of 0.9994 (for n?=?9). The detection limit (at SNR?=?3) is 0.23?ng?mL?1, and the relative standard deviations at 10 and 70?ng?mL?1 of antimony are 3.32 and 1.85?% (at n?=?8), respectively. The method compared favorably to other methods and was applied to determine antimony in seawater, anti-leishmania drug (glucantime), and human serum.
Figure
This method is based on the extraction of yellow iodoantimonous acid (HSbI4) into surfactant-rich phase of Triton X-114 when trivalent antimony in sulfuric acid solution is treated with an excess of potassium iodide solution.  相似文献   

6.
The use of the direct inlet probe–atmospheric-pressure chemical ionization (DIP-APCI) ion source developed in our laboratory coupled to a high resolution Q-TOF MS for the quantitative analysis of coumarin in different cinnamon samples was demonstrated in this study. Extraction of coumarin from various cinnamon samples was followed by DIP-APCI-mass spectrometry (MS) and liquid chromatography (LC)-MS analysis. For quantification, an external calibration with and without the use of stable isotope-labeled coumarin as internal standard was compared. The results obtained by DIP-APCI-MS and LC-MS were in good agreement. Even without the use of an internal standard satisfying linearity (R 2?>?0.997), recovery (94–104 % for spiking levels between 100 and 5,000 mg/kg) and intra- and interday repeatability (2.2–13.8 %RSD) was demonstrated using DIP-APCI-MS. To reduce the number of samples requiring quantitative analysis, the possibility of semi-quantitative screening of coumarin directly from powdered cinnamon using DIP-APCI-MS was shown. The analysis of woodruff-flavored beverages and cinnamon-flavored chewing gum by DIP-APCI-MS resulted in the formation of an artifact interfering with coumarin detection. As with other ambient ionization methods, special attention has to be paid to possible spectral interferences due to isobaric substances present in the sample matrix or formed from matrix components after ionization. The temperature-programmed vaporization in DIP-APCI-MS combined with the use of stable isotope-labeled coumarin as internal standard helped in recognizing this interference.
Figure
?  相似文献   

7.
The capsid of hepatitis B virus (HBV) is a major viral antigen and important diagnostic indicator. HBV capsids have prominent protrusions (‘spikes’) on their surface and are unique in having either T?=?3 or T?=?4 icosahedral symmetry. Mouse monoclonal and also human polyclonal antibodies bind either near the spike apices (historically the ‘α-determinant’) or in the ‘floor’ regions between them (the ‘β-determinant’). Native mass spectrometry (MS) and gas-phase electrophoretic mobility molecular analysis (GEMMA) were used to monitor the titration of HBV capsids with the antigen-binding domain (Fab) of mAb 3120, which has long defined the β-determinant. Both methods readily distinguished Fab binding to the two capsid morphologies and could provide accurate masses and dimensions for these large immune complexes, which range up to ~8 MDa. As such, native MS and GEMMA provide valuable alternatives to a more time-consuming cryo-electron microscopy analysis for preliminary characterisation of virus-antibody complexes.
Figure
Monitoring the binding of the antigen-binding domain (Fab) of mAb 3120 to hepatitis B capsids by native MS and GEMMA  相似文献   

8.
5-Hydroxymethylfurfural (HMF) was analyzed in 17 botanical varieties of honey from 12 countries. A recently developed high-performance thin-layer chromatographic (HPTLC) method was limited because of increased matrix effects at higher honey sample loading. Therefore, the method was modified to achieve higher sensitivity and eliminate matrix interference by use of rectangular application combined with a focusing step. The HPTLC results were compared with results from the new spectrophotometric Reflectoquant hydroxymethylfurfural assay. Both methods had quantification limits of 4 mg kg?1 and were suitable for rapid quantification of HMF in honey at the strictest regulated level of 15 mg kg?1. Comparable results were obtained for the 17 honey samples, with a mean deviation of 2.9 mg kg?1 (15 %). The optimized HPTLC method was proved to be highly matrix-robust and was validated for the 17 different honey matrices (correlation coefficients ≥0.9994 (n?=?6), mean intra-day precision 3.2 % (n?=?3 within a plate; n?=?2 repeated within a day), mean inter-day precision 3.7 % (n?=?3), mean reproducibility over the whole procedure including sample preparation 4.1 % (n?=?2), and mean recovery 106.9 % (n?=?5 different concentrations; n?=?4 different honey matrices). Recovery for a range of different application volumes, and thus for different honey matrix loading, differed by only ≤4.2 %. HMF results when calculated by use of external calibration and by use of the standard addition method varied by 8.8 %. Both revealed that any matrix effect was minor and that the original matrix interference problem was successfully solved.
Figure
HPTLC separation of HMF from honey matrix for honey with very low HMF content  相似文献   

9.
Liquid chromatography negative ion electrospray ionisation tandem mass spectrometry has been used for characterisation of naturally occurring prenylated fungal metabolites and synthetic derivatives. The fragmentation studies allow an elucidation of the decomposition pathways for these compounds. It could be shown, that the prenyl side chain is degraded by successive radical losses of C5 units. Both the benzoquinones and the phenolic derivatives display significant key ions comprising the aromatic ring. In some cases, the formation of significant oxygen-free key ions could be evidenced by high-resolution MS/MS measurements. Furthermore, the different types of basic skeletons, benzoquinones and phenol type as well as cyclic prenylated compounds, can be differentiated by their MS/MS behaviour.
Figure
Fruiting bodies of Suillus bovinus, the structure of boviquinone-4 and its negative ion MS2 spectrum  相似文献   

10.
A sensor for hydrogen peroxide is described that is based on an indium tin oxide electrode modified with Fe3O4 magnetic nanoparticles which act as a mimic for the enzyme peroxidase and greatly improve the analytical performance of the sensor. The amperometric current is linearly related to the concentration of H2O2 in the range from 0.2 mM to 2 mM, the regression equation is y?=?-0.5–1.82x, the correlation coefficient is 0.998 (n?=?3), and the detection limit is 0.01 mM (S/N?=?3). The sensor exhibits favorable selectivity and excellent stability.
Figure
Using the peroxidase mimic property of Fe3O4 magnetic nanoparticles (MNPs), a sensitive electrochemical method with favorable analytical performance for the determination of hydrogen peroxide (H2O2) was developed.  相似文献   

11.
A glassy carbon electrode (GCE) was modified with nickel(II) hydroxide nanoparticles and a film of molybdenum sulfide. The nanocomposite was prepared by two-step electrodeposition. Scanning electron microscopy reveals that the nanoparticles are uniformly deposited on the film. Cyclic voltammetry and chronoamperometry indicate that this modified GCE displays a remarkable electrocatalytic activity towards nonenzymatic oxidation of glucose. Response is linear in the 10–1,300 μM concentration range (R 2 ?=?0.9987), the detection limit is very low (5.8 μM), response is rapid (< 2 s), and selectivity over ascorbic acid, dopamine, uric acid, fructose and galactose is very good.
Figure
An efficient nonenzymatic glucose sensor based on Ni(OH)2/MoSx nanocomposite modified glassy carbon electrode has been fabricated via a two-step electrodeposition approach. The resulting nonenzymatic sensor exhibits excellent properties toward glucose detection, such as low detection limit, fast response and noticeable selectivity.  相似文献   

12.
We have developed a method for in-situ construction of a porous network-like silver film on the surface of a glassy carbon electrode (GCE). It is based on a galvanic replacement reaction where a layer of copper nanoparticles is first electrodeposited as a sacrificial template. The silver film formed possesses a porous network-like structure and consists of an assembly of numerous nanoparticles with an average size of 200 nm. The electrode displays excellent electrocatalytic activity, good stability, and fast response (within 2 s) toward the reduction of nitrate at a working potential of ?0.9 V. The catalytic currents linearly increase with the nitrate concentrations in the range of 0.08–6.52 mM, with a detection limit of 3.5 μM (S/N?=?3) and a repeatability of 3.4 % (n?=?5).
Figure
A facile method was developed for in situ construction of a porous network-like Ag film on a glassy carbon electrode by a galvanic replacement reaction, where a layer of Cu nanoparticles previously electrodeposited as a sacrificial template. Thus-formed Ag film displays excellent electrocatalytic activity, good stability, and fast response (within 2 s) toward nitrate reduction.  相似文献   

13.
We report on the synthesis and evaluation of aminated-CoFe2O4/SiO2 nanoparticles that can serve as a selective solid-phase sorbent for the extraction of cadmium ion. The nanoparticles consist of a magnetic CoFe2O4 core and an amino-modified silica shell. They can efficiently extract cadmium(II) ion and then can be isolated from the sample solution due to the magnetic nature of the core. The effects of the experimental conditions on the extraction process were optimized. Cadmium was then quantified by hydride generation atomic fluorescence spectrometry. The resulting calibration curve is linear in the concentration range of 0.01–10 μg?L?1, the instrumental detection limits (3σ) is 3.15 ng?L?1 and the relative standard deviation is 4.9 % at the 1.0 μg?L?1 level (for n?=?11). The enrichment factor is 50 (for 50 mL samples), and the adsorbent can be used for at least 45 cycles of preconcentration and elution. The method was applied to the determination of cadmium in environmental water samples, and successfully validated by analyzing two certified reference materials.
Figure
Magnetic solid-phase extraction coupled with hydride generation atomic fluorescence spectrometry for the determination of cadmium is described.  相似文献   

14.
In this work, (3,6-bis(2,3-dihydrothieno[3,4-b][1,4]dioxin-5-yl)-9-(4-vinylbenzyl)-9H-carbazole) (EDOTVBCz) comonomer was chemically synthesized and characterized by Fourier transform infrared (FTIR), proton nuclear magnetic resonance, and carbon nuclear magnetic resonance spectroscopy. EDOTVBCz was electrocoated on glassy carbon electrode (GCE) in various initial molar concentrations ([EDOTVBCz]0?=?1.0, 1.5, 2.0, and 3.0) in 0.1 M lithium perchlorate (LiClO4)/acetonitrile (CH3CN). P(EDOTVBCz)/GCE was characterized by cyclic voltammetry, FTIR reflectance-attenuated total reflection spectroscopy, scanning electron microscopy–energy dispersive X-ray analysis, atomic force microscopy, and electrochemical impedance spectroscopy (EIS). EIS was used to determine the capacitive behaviors of modified GCE via Nyquist, Bode magnitude, Bode phase, and admittance plots. The highest low-frequency capacitance value was obtained as C LF?=?~2.35 mF cm?2 for [EDOTVBCz]0?=?3.0 mM. Double-layer capacitance of the polymer/electrolyte system was calculated as C dl?=?~2.78 mF cm?2 for [EDOTVBCz]0?=?1.0 and 3.0 mM. The maximum phase angle was obtained as θ?=?~76.7o for [EDOTVBCz]0?=?1.0, 1.5, 2.0, and 3.0 mM at the frequency of 20.6 Hz. AC impedance spectra of P(EDOTVBCz)/LiClO4/CH3CN was obtained by performing electrical equivalent circuit model of R(Q(R(CR))) with linear Kramers–Kronig test.
Figure
SEM-EDX analysis of P(EDOTVBCz)/CFME EDX point analysis inset: SEM point analysis, [EDOTVBCz]0?=?3 mM. Chronoamperometric method of constant potential at 1.6 V, 300 s in 0.1 M LiClO4/CH3CN  相似文献   

15.
We report on a method for the extraction of the lanthanide ions La(III), Sm(III), Nd(III) and Pr(III) using a carbon-ferrite magnetic nanocomposite as a new adsorbent, and their determination via flow injection ICP-OES. The lanthanide ions were converted into their complexes with 4-(2-pyridylazo)resorcinol, and these were adsorbed onto the nanocomposite. Fractional factorial design and central composite design were applied to optimize the extraction efficiencies to result in preconcentration factors in the range of 141–246. Linear calibration plots were obtained, the limits of detection (at S/N?=?3) are between 0.5 and 10 μg?L?1, and the intra-day precisions (n?=?3) range from 3.1 to 12.8 %. The method was successfully applied to a certified reference material.
Figure
Superparamagnetic activated carbon based nanocomposite was synthesized and applied for extraction and determination of some rare earth elements in water samples  相似文献   

16.
Ceramide is a key metabolite in both anabolic and catabolic pathways of sphingolipids. The very long fatty acyl chain ceramides N-(docosanoyl)-sphing-4-enine (Cer(22:0)) and N-(tetracosanoyl)-sphing-4-enine (Cer(24:0)) are associated with multiple biological functions. Elevated levels of these sphingolipids in tissues and in the circulation have been associated with insulin resistance and diabetes. To facilitate quantification of these very long chain ceramides in clinical samples from human subjects, we have developed a sensitive, accurate, and high-throughput assay for determination of Cer(22:0) and Cer(24:0) in human plasma. Cer(22:0) and Cer(24:0) and their deuterated internal standards were extracted by protein precipitation and chromatographically separated by HPLC. The analytes and their internal standards were ionized using positive-ion electrospray mass spectrometry, then detected by multiple-reaction monitoring with a tandem mass spectrometer. Total liquid chromatography–tandem mass spectrometry (LC-MS/MS) runtime was 5 min. The assay exhibited a linear dynamic range of 0.02–4 and 0.08–16 μg/ml for Cer(22:0) and Cer(24:0), respectively, in human plasma with corresponding absolute recoveries from plasma at 109 and 114 %, respectively. The lower limit of quantifications were 0.02 and 0.08 μg/ml for Cer(22:0) and Cer(24:0), respectively. Acceptable precision and accuracy were obtained for concentrations over the calibration curve ranges. With the semi-automated format and short LC runtime for the assay, a throughput of ~200 samples/day can easily be achieved.
Figure
LC-MS/MS chromatograms for Cer(22:0) and Cer(24:0) in LLOQ, in which the analyte and internal standard are shown in blue and red, respectively  相似文献   

17.
Since sarcosine and d,l-alanine co-elute on reversed-phase high-performance liquid chromatography (HPLC) columns and the tandem mass spectrometer cannot differentiate them due to equivalent parent and fragment ions, derivatization is often required for analysis of sarcosine in LC/MS systems. This study offers an alternative to derivatization by employing partial elimination of sarcosine by enzymatic oxidation. The decrease in apparent concentration from the traditionally merged sarcosine–alanine peak associated with the enzymatic elimination has been shown to be proportional to the total sarcosine present (R 2?=?0.9999), allowing for determinations of urinary sarcosine. Sarcosine oxidase was shown to eliminate only sarcosine in the presence of d,l-alanine, and was consequently used as the selective enzyme. This newly developed technique has a method detection limit of 1 μg/L (parts per billion) with a linear range of 3 ppb–1 mg/L (parts per million) in urine matrices. The method was further validated through spiked recoveries of real urine samples, as well as the analysis of 35 real urine samples. The average recoveries for low, middle, and high sarcosine concentration spikes were 111.7, 90.8, and 90.1 %, respectively. In conclusion, this simple enzymatic approach coupled with HPLC/MS/MS is able to resolve sarcosine from d,l-alanine leading to underivatized quantification of sarcosine.
Figure
Enzymatic elimination of sarcosine from alanine  相似文献   

18.
We report on a novel method for on-line cloud point extraction (CPE) for preconcentration of cadmium ions. It is based on electromagnetic induction-assisted heating (EMIH) of iron particles in a packed bed contained in a quartz tube that acts as an on-line CPE enrichment column. The cadmium complex of 1-(2-pyridylazo)-2-naphthol is quantitatively retained by the column under the cloud point temperature with the help of EMIH. The column was then eluted with alcoholic borax buffer at room temperature and on-line coupled to FAAS. Under optimum conditions, the limit of detection (3 sb/b) and limit of quantification (10 sb/b) are 0.21 μg?L?1 and 0.70 μg?L?1 of Cd(II), respectively, and the relative standard deviation is 3.8 % (for n?=?8; at 20 ng?mL?1). An enhancement factor of 76 is typically achieved. The correlation coefficient of the calibration graph using the present method was 0.9986. The method was successfully applied to determine Cd(II) in water samples
Figure
An on-line cloud point extraction method was developed. Iron particles packed bed acts as an enrichment column. The cadmium complex of 1-(2-pyridylazo)-2-naphthol is quantitatively retained by the column under the cloud point temperature with the help of electromagnetic induction-assisted heating technique  相似文献   

19.
Trace levels of the veterinary antibiotic compound sulfadiazine (SDZ) can be determined in agricultural drainage water samples with this new method. Optimized sample pretreatment and solid-phase extraction was combined with liquid chromatography coupled to tandem mass spectrometry (SPE LC-MS/MS) using positive electrospray ionization. The linear dynamic range for the LC-MS/MS was assessed from 5 μg/L to 25 mg/L with a 15-point calibration curve displaying a coefficient of correlation r 2?=?0.9915. Agricultural drainage water spiked at a concentration of 25 ng/L gave recoveries between 63 and 98 % (relative standard deviation 15 %), while at 10 ng/L, it showed a lower recovery of 32 % (relative standard deviation 47 %). The final SPE LC-MS/MS method had a limit of detection (LOD)Method and a limit of quantification (LOQ)Method of 7.5 and 23 ng/L agricultural drainage water, respectively. Determination of SDZ, spiked at a realistic concentration of 50 μg/L, in artificial drainage water (ADW) containing common and high levels of phosphate (0.05, 0.5, and 5 mg/L) gave recoveries between 70 and 92 % (relative standard deviation 7.4–12.9 %). Analysis of the same realistic concentration of SDZ in ADW, spiked with common and high levels of dissolved organic carbon (2, 6, and 15 mg/L) confirmed the possible adaptation of a tandem solid-phase extraction (strong anion exchange (SAX)-hydrophilic-lipophilic balance (HLB)) followed by liquid chromatography-tandem mass spectrometry methodology. Recoveries obtained ranged from 104 to 109 % (relative standard deviation 2.8–5.2 %). The new methods enable determination of the veterinary antibiotic compound SDZ in agricultural drainage water from field experiments and monitoring schemes for phosphate- and dissolved organic carbon (DOC)-rich water samples in intensive farming areas.
Figure
Clean-up and up-concentration of sulfadiazine from agricultural drainage water  相似文献   

20.
We report on the synthesis of Fe3O4-functionalized metal-organic framework (m-MOF) composite from Zn(II) and 2-aminoterephthalic acid by a hydrothermal reaction. The magnetic composite is iso-reticular and was characterized by FTIR, X-ray diffraction, SEM, magnetization, and TGA. The m-MOF was then applied as a sorbent for the solid-phase extraction of trace levels of copper ions with subsequent quantification by electrothermal AAS. The amount of sorbent applied, the pH of the sample solution, extraction time, eluent concentration and volume, and desorption time were optimized. Under the optimum conditions, the enrichment factor is 50, and the sorption capacity of the material is 2.4 mg g?1. The calibration plot is linear over the 0.1 to 10 μg L?1 Cu(II) concentration range, the relative standard deviation is 0.4 % at a level of 0.1 μg L?1 (for n?=?10), and the detection limit is as low as 73 ng L?1. We consider this magnetic MOF composite to be a promising and highly efficient material for the preconcentration of metal ions.
Figure
Magnetic metal-organic frameworks was synthesized and used as a new sorbent for lead adsorption with detection by electrothermal atomic absorption spectrometry.  相似文献   