首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
采用一种简单灵敏的方法开发了在多壁碳纳米管修饰的ZnCrFeO4糊电极(MWCNTs/ZnCrFeO4/CPE)表面测定苄丙酮香豆素的新型传感器.运用循环伏安法、差示脉冲伏安法、计时电流法和电化学阻抗谱考察了该化学修饰电极上苄丙酮香豆素的电化学性能.结果表明,MWCNTs/ZnCrFeO4/CPE电极对苄丙酮香豆素氧化表现出较高的电催化活性,在pH=4时,产生峰值氧化电流约0.97 vs Ag/AgCl参比电极.当苄丙酮香豆素浓度在0.02-920.0 μmol/L范围内,该峰电流与其呈线性关系,检测极限(3σ)为0.003 μmol/L.另外,运用差示脉冲伏安法测定了MWCNTs/ZnCrFeO/CPE电极上苄丙酮香豆素的催化反应速率常数和扩散系数.  相似文献   

2.
A chemically modified electrode is constructed based on the multi-walled carbon nanotubes (MWNTs)/4-aminobenzeresulfonic acid (4-ABSA) film-coated glassy carbon electrode. The electrocatalytic oxidation of tyrosine (Tyr) is investigated on the surface of the MWNTs/4-ABSA-modified electrode using cyclic voltammetry (CV) and differential pulse voltammetry (DPV). The prepared modified electrode shows voltammetric responses with high sensitivity and selectivity for Tyr in optimal conditions, which makes it very suitable for sub-micromolar detection of Tyr. A sensitive oxidation peak at +0.64 V is employed to determine Tyr. Good linear relationship between the oxidation peak current and the Tyr concentration in the range of 1 × 10−7 to 5 × 10−5 mol/L is obtained in phosphate buffer solution with pH 7.0. By use of modified electrode, the voltammetric detection limit for Tyr in DPV measurements is 8 × 10−8 mol/L (S/N = 3). Good sensitivity, selectivity and stability of the low-cost modified electrode make it very suitable for the determination of trace amounts of Tyr in pharmaceutical and clinical preparations.  相似文献   

3.
A sensitive electrochemical sensor for the determination of cysteamine(CA) was developed using a modified multiwall carbon nanotube paste electrode(MWCNTPE) with isoproterenol(ISPT) as a mediator.This modified electrode showed very high electrocatalytic activity for the anodic oxidation of CA.Under the optimized conditions,the electrocatalytic peak current showed a linear relationship with CA concentration in the range of 0.3–450.0 mmol/L with a detection limit of 0.09 mmol/L CA.The modified electrode was used for the determination of CA in real samples such as urine and drug samples.  相似文献   

4.
L-酪氨酸功能化多壁碳纳米管的制备及表征   总被引:1,自引:0,他引:1  
采用L-酪氨酸作为修饰剂,制备了一种新型功能化的多壁碳纳米管,并对其进行了表征。红外光谱和电化学实验均证实碳纳米管和酪氨酸是通过酰胺键共价键合的。其中,循环伏安实验中0.22V处羧基峰的消失与红外光谱中1717cm^-1处N-酰化氨基酸的-C=O峰相对应,2931和2860cm^-1处的-CH2-的伸缩振动峰的出现证明了产物的形成。  相似文献   

5.
A simple and rapid electrochemical method is developed for the determination of trace-level norfloxacin, based on the excellent properties of multi-walled carbon nanotubes (MWCNTs). The MWCNTs/Nafion film-coated glassy carbon electrode (GCE) is constructed and the electrochemical behavior of norfloxacin at the electrode is investigated in detail. The results indicate that MWCNTs modified glassy carbon electrode exhibited efficiently electrocatalytic oxidation for norfloxacin (NFX) with relatively high sensitivity, stability and life time. Under conditions of cyclic voltammetry, the current for oxidation of selected analyte is enhanced significantly in comparison to the bare GCE. The electrocatalytic behavior is further exploited as a sensitive detection scheme for the analyte determinations by linear sweep voltammetry (LSV). Under optimized condition in voltammetric method the concentration calibration range and detection limit (S/N=3) are 0.1-100 micromol/L and 5 x 10(-8)mol/L for NFX. The proposed method was successfully applied to NFX determination in tablets. The analytical performance of this sensor has been evaluated for detection of the analyte in urine as a real sample.  相似文献   

6.
The electroanalytical performance of bare glassy carbon electrodes (GCE) for the determination of 1‐aminonaphthalene (1‐AN) and 2‐aminonaphthalene (2‐AN) was compared with GCE modified by a Nafion permselective membrane or multiwalled carbon nanotubes and with other types of carbon‐based materials, carbon film and boron doped diamond. Nafion‐modified GCE gave the highest sensitivity and lowest detection limit (0.4 µmol L?1) for differential pulse voltammetric determination of 1‐AN. Electrochemical impedance spectroscopy gave information about the processes at the electrode surface. Simultaneous determination of 1‐AN and 2‐AN in a mixture at GCE and their determination in model samples of river water is presented.  相似文献   

7.
Guo L  Lee HK 《Journal of chromatography. A》2011,1218(52):9321-9327
Micro-solid-phase extraction (μ-SPE) was developed for the determination of trace level of 16 United States Environmental Protection Agency priority polycyclic aromatic hydrocarbons (PAHs) in river water samples with gas chromatography-mass spectrometry (GC-MS). In the μ-SPE device, multiwalled carbon nanotubes was employed as sorbent and was packed inside an porous polypropylene membrane "envelope" whose edges were heat-sealed to secure the contents. The μ-SPE device was placed in a stirred sample solution to extract the analytes. The porous polypropylene membrane envelope in μ-SPE device acts as a filter to exclude potential interferences, such as eliminating or reducing the influence of particles that are bigger than the pore size. After extraction, analyte desorption was carried out with a suitable organic solvent under ultrasonication. Important extraction parameters were optimized in detail, including the selection and amount of sorbent materials, the extraction temperature and extraction time, desorption solvent and desorption time, amount of organic modifier, agitation speed and sample ionic strength. Under the developed extraction conditions, the proposed method provided good linearity in the range of 0.1-50 μg/L, low limits of detection (4.2-46.5 ng/L), and good repeatability of the extractions (relative standard deviations, <12%, n=5). The developed μ-SPE method was successfully applied to the extraction of PAHs in river water samples. The μ-SPE method was demonstrated to be a fast and efficient method for the determination of PAHs from environmental water samples.  相似文献   

8.
In the present work, the electrochemical behavior of an antimigraine drug, almotriptan malate (ALM), on a multiwalled carbon nanotube (MWCNT) film modified glassy carbon electrode under cyclic voltammetry was described for the first time. A significant enhancement in the oxidation peak current of ALM was noticed at MWCNT‐GCE. This property was exploited to develop a simple, sensitive and time‐saving differential pulse voltammetric method for the determination of ALM in bulk and pharmaceutical samples. A linear relationship was observed between concentration and peak current with a correlation coefficient of 0.9915 in the range of 0.25–37.5 µM ALM.  相似文献   

9.
研究了苦参碱(Matrine, MT) 在多壁碳纳米管修饰玻碳电极(MWCNT/GCE)上的电化学行为. 与GCE相比, MT在MWCNT/GCE上峰电位负移120 mV, 峰电流增大约2.5倍, 表明MWCNT/GCE对MT的电化学氧化具有良好的催化作用. 同时测定并计算了MT在MWCNT/GCE上的电极过程动力学参数: 电子转移系数α、电极反应速率常数ks、扩散系数D. 运用差分脉冲伏安法对苦参碱样品含量进行测定, 相对标准偏差为0.12%~2.9%, 加标回收率为98.4%~99.0%. 该方法可用于MT的电化学定量测定.  相似文献   

10.
Biosensors based on carbon nanotubes   总被引:6,自引:0,他引:6  
Carbon nanotubes (CNTs) exhibit a unique combination of excellent mechanical, electrical and electrochemical properties, which has stimulated increasing interest in the application of CNTs as components in (bio)sensors. This review highlights various design methodologies for CNT-based biosensors and their employment for the detection of a number of biomolecules. In addition, recent developments in the fields of CNT-based chemiresistors and chemically sensitive field-effect transistors are presented. After a critical discussion of the factors that currently limit the practical use of CNT-based biosensors, the review concludes with an outline of potential future applications for CNTs in biology and medicine.   相似文献   

11.
The exploitation of antibiotics has caused many side effects on the agriculture, environment, and human health. The existing methods have numerous shortcomings in determining gentamicin (GEN), a broad-spectrum antibiotic that causes nephrotoxicity and ototoxicity when found in excess. Here, an immunosensing platform to detect GEN using multiwalled carbon nanotubes (MWCNTs) and molybdenum disulfide (MoS2) nanocomposite, deposited electrophoretically on indium tin oxide (ITO) glass has been developed. A novel 2-D graphene analog MoS2@ MWCNTs nanocomposite was made via a facile and low-cost hydrothermal technique using l-cysteine to achieve remarkable electrochemical properties. Subsequently, a highly sensitive electrochemical immunosensor was fabricated by assembling monoclonal antibodies against gentamicin (anti-GEN) on a MoS2@MWCNTs modified ITO electrode. The hetero-nanostructure formed on the immunosensor surface appeared relatively good conductor for accelerating the electron transfer. GEN was determined on anti-GEN modified electrodes by utilizing the differential pulse voltammetry technique by measuring the difference in current owing to the transfer of electrons directly between the redox species and immunoelectrodes. Under optimal experimental conditions, the fabricated immunosensor had a wide linear detection range of 1 × 10?6–40 μg/mL, a high sensitivity of 13.55 μA (log μg/mL)?1 and a low limit of detection and limit of quantification of 0.039 μg/mL and 0.130 μg/mL, respectively. The developed immunosensor also exhibits high reproducibility, repeatability, and good selectivity against various interferences. This electrochemical immunosensor having MoS2 modified MWCNTs displays the excellent potential for the point-of-care device for GEN testing.  相似文献   

12.
Yang P  Wei W  Tao C 《Analytica chimica acta》2007,585(2):331-336
Novel nano-silver coated multi-walled carbon nanotube composites were prepared and used to fabricate a modified electrode. The application of the nano-silver coated multi-walled carbon nanotube composites modified electrode for determination of trace thiocyanate is demonstrated for the first time. The influence of substrate, pH and interference of coexisting substances was investigated for response properties of the electrode. There was a linear relationship at the range 2.5 × 10−9 to 5 × 10−8 mol L−1 and 5 × 10−8 to 1 × 10−6 mol L−1 of thiocyanate with the decrement of anodic DPV peak currents. The limit of detection was 1 × 10−9 mol L−1(S/N = 3). The constructed electrode showed excellent reproducibility and stability. Actual urine and saliva samples of smoker and non-smoker were analyzed and satisfactory results were obtained. This method provides a new way to construct any electrode for biological and environmental analysis.  相似文献   

13.
Chen L  Chen W  Ma C  Du D  Chen X 《Talanta》2011,84(1):104-108
A novel solid-phase microextraction (SPME) fiber coated with multiwalled carbon nanotubes/polypyrrole (MWCNTs/Ppy) was prepared with an electrochemical method and used for the extraction of pyrethroids in natural water samples. The results showed that the MWCNTs/Ppy coated fiber had high organic stability, and remarkable acid and alkali resistance. In addition, the MWCNTs/Ppy coated fiber was more effective and superior to commercial PDMS and PDMS/DVD fibers in extracting pyrethroids in natural water samples. Under optimized conditions, the calibration curves were found to be linear from 0.001 to 10 μg mL−1 for five of the six pyrethroids studied, the exception being fenvalerate (which was from 0.005 to 10 μg mL−1), and detection limits were within the range 0.12-0.43 ng mL−1. The recoveries of the pyrethroids spiked in water samples at 10 ng mL−1 ranged from 83 to 112%.  相似文献   

14.
Rajesh N. Hegde 《Talanta》2009,79(2):361-368
A simple and rapid electrochemical method was developed for the determination of trace-level trazodone, based on the excellent properties of multi-walled carbon nanotubes (MWCNTs). The MWCNT-modified glassy carbon electrode was constructed and the electrochemical behavior of trazodone was investigated in detail. The cyclic voltammetric results indicate that MWCNT-modified glassy carbon electrode can remarkably enhance electrocatalytic activity towards the oxidation of trazodone in neutral solutions. It leads to a considerable improvement of the anodic peak current for trazodone, and allows the development of a highly sensitive voltammetric sensor for the determination of trazodone. Trazodone could effectively accumulate at this electrode and produce two anodic peaks at about 0.73 V and 1.00 V. The electrocatalytic behavior was further exploited as a sensitive detection scheme for the trazodone determination by differential-pulse voltammetry. Under optimized conditions, the concentration range and detection limit are 0.2-10 μM and 24 nM, respectively for trazodone. The proposed method was successfully applied to trazodone determination in pharmaceutical samples. The analytical performance of this sensor has been evaluated for detection of analyte in urine as a real sample.  相似文献   

15.
An electrochemical sensor for doxycycline hyclate(DC)detection with high sensitivity and good selectivity is reported.The sensor was fabricated by electro-polymerization of molecularly imprinted polymers(MIPs)in the presence of DC onto multi-walled carbon nanotubes modified glassy carbon electrode(MWCNTs/GCE).The MWCNTs can significantly increase the current response of the sensor,leading to enhanced sensitivity.The MIPs provide selective recognition sites for DC detection.The experimental parameters,such as the polymer monomer concentration,supporting electrolyte pH,the time for electro-polymerization and the incubation time of the sensor with DC were optimized.Under optimized experimental conditions,the sensor displayed a linear range of 0.05μmol/L-0.5μmol/L towards DC detection,with the detection limit of 1.3×10^-2μmol/L.The sensor was successfully applied for recovery test of DC in human serum samples.  相似文献   

16.
The selective isolation of acidic proteins using a thin layer of multiwalled carbon nanotubes (MWNTs) functionalized with polydiallyldimethylammonium chloride (PDDA) was demonstrated. A certain amount (20 ml) of a suspension of PDDA-functionalized MWNTs that had been well dispersed by sonication was filtered through an MF-Millipore membrane with a pore aperture of 1.2 μm, and a uniform layer of PDDA-MWNT composites with a thickness of ca. 5 μm formed on the membrane. A 4 × 1 cm piece of the obtained membrane was supported by a stainless steel wire mesh and was then sandwiched between two PTFE films with grooved flow-through channels to form an extraction module. This module with a flow inlet and outlet was incorporated into a sequential injection system for performing the on-line separation and preconcentration of acidic protein, i.e., bovine serum albumin (BSA), and the BSA retained on the layer was eluted with a citrate buffer used as stripping reagent. In addition to a significant reduction in flow resistance, a dynamic sorption capacity of 3.8 mg mg−1 or 1.4 mg cm−2 for BSA was achieved using the layer-based system—a 146-fold improvement over that obtained using a packed microcolumn mode. A sample volume of 2.0 ml yielded an enrichment factor of 17, a retention efficiency of 100% and a recovery of 95%, along with a sampling frequency of 20 h−1 and a RSD value of 2.8% at 25 μg ml−1 for BSA. The practical applicability of the system was demonstrated by isolating acidic proteins (especially human serum albumin) from whole blood. Figure Selective isolation of acidic proteins with a composite thin layer of multi-walled carbon nanotubes functionalized with poly-diallyldimethylammonium chloride  相似文献   

17.
Salimi A  Hallaj R 《Talanta》2005,66(4):967-975
The performance of preheated glassy carbon electrode modified with carbon nanotubes is described. First glassy carbon electrode is heated for 5 min at 50 °C, then abrasive immobilization of multiwall carbon nanotubes on a preheated glassy carbon electrode was achieved by gentle rubbing of electrode surface on a filter paper supporting carbon nanotubes. Carbon nanotubes (CNTs)-modified glassy carbon electrodes exhibit strong and stable electrocatalytic response toward thiols oxidation in wide pH range. These properties permit an important decrease in over voltage for the oxidation of thiocytosine, glutathione and l-cysteine, as well as a dramatic increase in the peak currents in comparison with bare glassy carbon electrode. Furthermore, the thiols amperometric response of the coated electrodes is extremely stable, with more than 95% of the initial activity after 30 min stirring of 0.1 mM thiols. The electrocatalytic behavior is further exploited as a sensitive detection scheme for thiols detection by hydrodynamic amperometry. The substantial decrease in the overvoltage of the thiols oxidation associated with a stable amperometric response and antifouling properties of nanotubes films allow the development of highly sensitive thiols sensor without using any redox mediator. Such ability of carbon nanotubes to promote the thiols electron transfer reaction, short response time (5 s) and long-term stability, low detection limit, extended linear concentration range, high sensitivity suggest great promise for thiols amperometric sensors and detector for chromatographic analysis of thiol derivatives.  相似文献   

18.
A novel glassy carbon electrode (GCE) modified with a composite film of poly (4-vinylpyridine) (P4VP) and multiwalled carbon nanotubes (P4VP/MWCNT GCE) was used for the voltammetric determination of paracetamol (PCT). This novel electrode displayed a combined effect of P4VP and MWCNT on the electro-oxidation of PCT in a solution of phosphate buffer at pH 7. Hence, conducting properties of P4VP along with the remarkable physical properties of MWCNTs might have combined effects in enhancing the kinetics of PCT oxidation. The P4VP/MWCNT GCE has also demonstrated excellent electrochemical activity toward PCT oxidation compared to that with bare GCE and MWCNT GCE. The anodic peak currents of PCT on the P4VP/MWCNT GCE were about 300 fold higher than that of the non-modified electrodes. By applying differential pulse voltammetry technique under optimized experimental conditions, a good linear ratio of oxidation peak currents and concentrations of PCT over the range of 0.02–450 μM with a limit of detection of 1.69 nM were achieved. This novel electrode was stable for more than 60 days and reproducible responses were obtained at 99% of the initial current of PCT without any influence of physiologically common interferences such as ascorbic acid and uric acid. The application of this electrode to determine PCT in tablets and urine samples was proposed.  相似文献   

19.
Acetaminophenol or paracetamol is one of the most commonly used analgesics in pharmaceutical formulations. Acetaminophen is electroactive and voltammetric mechanistic studies for the electrode processes of the acetaminophenol/N-acetyl-p-quinoneimine redox system are presented. Carbon nanotubes modified screen-printed electrodes with enhanced electron transfer properties are used for the study of the electrochemical-chemical oxidation mechanism of paracetamol at pH 2.0.Quantitative analysis of paracetamol by using its oxidation process (in a Britton-Robinson buffer solution pH 10.0) at +0.20 V (vs. an Ag pseudoreference electrode) on an untreated screen-printed carbon electrode (SPCE) was carried out. Thus, a cyclic voltammetric based reproducible determination of acetaminophen (R.S.D., 2.2%) in the range 2.5 × 10−6 M to 1 × 10−3 M, was obtained. However, when SPCEs are used as amperometric detectors coupled to a flow injection analysis (FIA) system, the detection limit achieved for paracetamol was 1 × 10−7 M, one order of magnitude lower than that obtained by voltammetric analysis. The repeatability of the amperometric detection with the same SPCE is 2% for 15 successive injections of 10−5 M acetaminophen and do not present any memory effect.Finally, the applicability of using screen-printed carbon electrodes for the electrochemical detection of paracetamol (i.e. for quality control analysis) was demonstrated by using two commercial pharmaceutical products.  相似文献   

20.
Quercetin can effectively accumulate at multi-walled carbon nanotubes-paraffin oil paste electrodes (CNTPE) and cause a sensitive anodic peak at around 0.32 V (vs. SCE) in a 0.10 M phosphate buffer solution (pH = 4.0). Under optimized conditions, the anodic peak current is linear to quercetin concentration in the ranges of 2.0 × 10− 9−1.0 × 10− 7 M and 1.0 × 10− 7−2.0 × 10− 5 M, and the regression equations are ip (μA) = 0.0017 + 0.928c (μM, r = 0.999) and ip (μA) = 0.183 + 0.0731c (μM, r = 0.995), respectively. This paste electrode can be regenerated by repetitively cycling in a blank solution for about 2 min. A 1.0 × 10− 6 M quercetin solution is measured for 10 times using the same electrode regenerated after every determination, and the relative standard deviation of the peak current is 1.7%. The method has been applied to the determination of quercetin in hydrolysate product of rutin and the recovery is 99.2–102.6%. In comparison with graphite paste electrode, carbon nanotubes-nujol paste electrode and carbon nanotubes casting film modified glassy carbon electrode, the CNTPE gives higher ratio of signal to background current and better defined voltammetric peak.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏