首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 0 毫秒
1.
High-performance liquid chromatography (HPLC) combined with inductively coupled plasma mass spectrometry (ICPMS) has been studied as a means for the detection of carbon to provide a 'universal' method for detecting organic compounds in chromatographic eluents. Carbon is particularly difficult to ionise and the amount of carbon present in normal chromatographic systems leads to high backgrounds, making detection a challenge. Novel separation approaches were therefore employed, using either entirely aqueous eluents (at temperatures of 60 and 160 degrees C, dependent on the column used) to eliminate the organic modifier completely, or isotopically enriched solvents. For the aqueous eluents, detection limits for sulphanilamide were found to be 2.26 microg, corresponding to 1.13 micromol (0.47 micromol of carbon), injected on a conventional 4.6 mm i.d. column. The use of a narrow bore column with highly isotopically enriched 12C-methanol (99.95 atom%) as organic modifier for the mobile phase enabled the detection of 86 micromol for 13C-triple-labelled caffeine and 79 micromol for 13C-double-labelled phenacetin. The sensitive detection of 12C-compounds with 13C-enriched methanol as organic modifier proved impractical due to a lower level of isotopic enrichment (99 atom%) of this solvent, with the residual 12C-methanol resulting in significant interference.  相似文献   

2.
An automated method for high‐throughput amino acid analysis, using precolumn derivatization high‐performance liquid chromatography/electrospray mass spectrometry (HPLC/ESI‐MS), was developed and evaluated. The precolumn derivatization step was performed in the reaction port of a home‐built auto‐sampler system. Amino acids were derivatized with 3‐aminopyridyl‐N‐hydroxysuccinimidyl carbamate, and a 3 μm Wakosil‐II 3C8‐100HG column (100 × 2.1 mm i.d.) was used for separation. To achieve a 13 min cycle for each sample, the derivatization and separation steps were performed in parallel. The results of the method evaluation, including the linearity, and the intra‐ and inter‐precision, were sufficient to measure physiological amino acids in human plasma samples. The relative standard deviations of typical amino acids in actual human plasma samples were below 10%. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
With PMP chiral derivatization, the D/L-2HB and D/L-3HB enantiomers can be distinctly determined by reversed-phase chromatographic separation. In addition, the detection sensitivities were greatly enhanced by LC-ESI-MS analysis due to the introduction of easily ionizable tertiary amino group from PMP.  相似文献   

4.
The applicability of benzofurazan derivatization regents to carboxylic acids analysis in LC/ESI-MS/MS (high-performance liquid chromatography/electrospray ionization tandem mass spectrometry) was examined. The product ion spectra of DAABD-AE {4-[2-(N,N-dimethylamino)ethylaminosulfonyl]-7-(2-aminoethylamino)-2,1,3-benzoxadiazole}, DAABD-PZ {4-[2-(N,N-dimethylamino)ethylaminosulfonyl]-7-N-piperazino-2,1,3-benzoxadiazole}, DAABD-PiCZ {4-[4-carbazoylpiperidin-1-yl]-7-[2-(N,N-dimethylamino)ethylaminosulfonyl]-2,1,3-benzoxadiazole}, DAABD-ProCZ {4-[2-carbazoylpyrrolidin-1-yl]-7-[2-(N,N-dimethylamino) ethylaminosulfonyl]-2,1,3-benzoxadiazole} and DAABD-Apy {4-[2-(N,N-dimethylamino)ethylaminosulfonyl]-7-(3-aminopyrrolidin-1-yl)-2,1,3-benzoxadiazole}, and their acetylated compounds were obtained. An intense fragment ion at m/z 151 corresponding to (dimethylamino)ethylaminosulfonyl moiety was observed in each spectra, suggesting that these reagents were suitable for ESI-MS/MS analysis. DAABD-AE, DAABD-APy and DAABD-PZ were applied to the analysis of octanoic acid and it was found that DAABD-AE and DAABD-APy gave high signal intensity suitable for LC/ESI-MS/MS.  相似文献   

5.
Three N-substituted maleimides were tested as derivatizing reagents; N-(4-anilinophenyl) maleimide (APM) was the most favorable in terms of sensitivity and reactivity. N-Acetyl-l-cysrteine, glutathione, l-cysteine and d-penicillamine were readily converted into the adducts with APM. Picogram levels of these thiol compounds were separated and quantified.  相似文献   

6.
Fuh MR  Hsieh CJ  Tai YL 《Talanta》1999,49(5):158-1075
This paper describes a newly developed high performance liquid chromatography/electrospray/mass spectrometry (HPLC/ES/MS) method for the determination of flunarizine (FZ) in artificial cerebrospinal fluid. The optimization for the detection of FZ in biological fluid by LC/ES/MS was investigated. The effects of solvent composition, the addition of modifier and flow rate on the detection of FZ by ES/MS were examined. The detection limit of this method (0.8 nM) proved to be much better than previously reported methods. Satisfactory accuracy (98.2–106.0%) of this newly developed method was obtained. The application of this method was demonstrated by analyzing FZ in rat microdialysis samples.  相似文献   

7.
The applicability of 3‐pyridyl isothiocyanate, p‐(dimethylamino)phenyl isothiocyanate and m‐nitrophenyl isothiocyanate as the derivatization reagents for amines in high‐performance liquid chromatography/electrospray ionization–tandem mass spectrometry (LC/ESI‐MS/MS) was examined. The generated derivatives of amines with these reagents were favorably separated on the reversed‐phase column and detected by ESI‐MS/MS. The C–N bond of the generated thiourea structure was efficiently cleaved by collision‐induced dissociation and gave the single and intense product ion. Among the three reagents, 3‐pyridyl isothiocyanate was the most suitable as the derivatization reagent with regard to the reactivity to amines and the detection sensitivity. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
9.
A liquid chromatography (LC)/mass spectrometry method was developed for the determination of selected biogenic amines in various fish and other food samples. It is based on a precolumn derivatization of the amines with succinimidylferrocenyl propionate under formation of the respective amides and their reversed-phase liquid-chromatographic separation with subsequent electrospray ionization mass-spectrometric detection. Deuterated putescine, cadaverine, and histamine are added prior to the derivatization as internal standards that are coeluted, thus allowing excellent reproducibility of the analysis to be achieved. Depending on the analyte, the limits of detection were between 1.2 and 19.0 mg/kg, covering between 2 and 3 decades of linearity. The limit of detection and the linear range for histamine are suitable for the surveillance of the only defined European threshold for biogenic amines in fish samples. Compared with the established ortho-phthalaldehyde (OPA)/LC/fluorescence method, the newly developed method allows an unambiguous identification of the biogenic amines by their mass spectra in addition to only retention times, a fivefold acceleration of the separation, and independency from the sample matrix owing to the isotope-labeled internal standards. Various fish, calamari, and salami samples were successfully analyzed with the new method and validated with an independent OPA/LC/fluorescence method.  相似文献   

10.
Each year increasing numbers of proteins are submitted for routine characterization by liquid chromatography/mass spectrometry (LC/MS). This paper reports a solution that transforms routine LC/MS analysis of proteins into a fully automated process that significantly reduces analyst intervention. The solution developed, protein open-access (OA) LC/MS, consists of web-enabled sample submission and registration, automated data processing, data interpretation, and report generation. Sample submissions and results are recorded in a LIMS that utilizes an Oracle database. The protein sequence is captured during the sample submission process, stored in the database, and utilized to determine the theoretical protein molecular weight. This calculated mass is used to set the parameters for transformation of the mass-to-charge spectra to the mass domain and evaluate the presence or absence of the desired protein. Three protein OA-LC/MS instruments have been deployed in our facility to support protein characterization, purification, and modification efforts.  相似文献   

11.
Over the last decade, time-of-flight (TOF) instruments have increasingly been used as quantitation tools. In addition, because of their high resolving power, they can be used for verification of empirical formulas. Historically, TOF instruments have had limited quantitation capabilities because of their narrow dynamic range. However, recent advances have improved these limitations. This review covers the rationale for using TOF for LC detection, and describes the many methods currently in the literature for the quantitation of pharmaceuticals, environmental pollutants, explosives and many phytochemicals.  相似文献   

12.
液相色谱/元素分析-同位素比值质谱联用法鉴定蜂蜜掺假   总被引:8,自引:0,他引:8  
费晓庆  吴斌  沈崇钰  丁涛  李丽花  路颖 《色谱》2011,29(1):15-19
采用液相色谱/元素分析-同位素比值质谱联用法(LC/EA-IRMS)对国内蜂蜜掺假情况进行了研究。基于测定得到的38个纯正蜂蜜样品的碳同位素δ13C值数据,提出了纯正蜂蜜样品的δ13C值要求: 蛋白质和蜂蜜的δ13C差值(Δδ13CP-H)≥~0.95‰,果糖和葡萄糖的δ13C差值(Δδ13CF-G)在~0.64‰至0.53‰范围内,各个组分间的δ13C最大差值(Δδ13Cmax)<2.09‰。对150个日常检测样品、蜂农和蜂蜜供应商的蜂蜜样品分别采用本文建立的LC/EA-IRMS和国家标准方法(EA-IRMS)进行鉴定,LC/EA-IRMS方法检出58个掺有C3或C4植物糖浆的阳性样品,而EA-IRMS方法仅检出7个掺有C4植物糖浆的阳性样品,可见新方法大大提高了对蜂蜜掺假的鉴别能力。  相似文献   

13.
A sensitive liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed to determine carbocysteine in human plasma using 2-pyridylacetic acid as the internal standard (IS). The method employed derivatization with 10 M hydrochloric acid/methanol, which significantly improved the ionization efficiency of carbocysteine. After methanol-induced protein precipitation of plasma samples, carbocysteine and the IS were derivatized and subjected to LC/MS/MS analysis using atmospheric pressure chemical ionization. The method has a lower limit of quantitation of 20 ng/mL for a 0.2-mL plasma aliquot. The intra- and inter-day precision (RSD), calculated from quality control (QC) samples, was less than 7%. The accuracy, determined using QC samples, was within +/- 1%. The method offered increased sensitivity, selectivity and speed of analysis over existing methods. The method was utilized to support clinical pharmacokinetic studies of carbocysteine in volunteers following oral administration.  相似文献   

14.
Off-line two-dimensional liquid chromatography with tandem mass spectrometry detection (2D-LC/MS-MS) was used to separate a set of metabolomic species. Water-soluble metabolites were extracted from Escherichia coli and Saccharomyces cerevisae cultures and were immediately analyzed using strong cation exchange (SCX)-hydrophilic interaction chromatography (HILIC). Metabolite mixtures are well-suited for multidimensional chromatography as the range of components varies widely with respect to polarity and chemical makeup. Some currently used methods employ two different separations for the detection of positively and negatively ionized metabolites by mass spectrometry. Here we developed a single set of chromatographic conditions for both ionization modes and were able to detect a total of 141 extracted metabolite species, with an overall peak capacity of ca. 2500. We show that a single two-dimensional separation method is sufficient and practical when a pair or more of unidimensional separations are used in metabolomics.  相似文献   

15.
Two new algorithms for automated processing of liquid chromatography/mass spectrometry (LC/MS) data are presented. These algorithms were developed from an analysis of the noise and artifact distribution in such data. The noise distribution was analyzed by preparing histograms of the signal intensity in LC/MS data. These histograms are well fit by a sum of two normal distributions in the log scale. One new algorithm, median filtering, provides increased performance compared to averaging adjacent scans in removing noise that is not normally distributed in the linear scale. Another new algorithm, vectorized peak detection, provides increased robustness with respect to variation in the noise and artifact distribution compared to methods based on determining an intensity threshold for the entire dataset. Vectorized peak detection also permits the incorporation of existing algorithms for peak detection in ion chromatograms and/or mass spectra. The application of these methods to LC/MS spectra of complex biological samples is described.  相似文献   

16.
Findings of illegal hormone preparations such as syringes, bottles, cocktails, and so on, are an important information source for the nature of the current abuse of anabolic steroids and related compounds as growth-promoting agents in cattle. A new screening method for steroids in cocktails is presented based on liquid chromatography (LC) with diode-array UV-absorbance detection and electrospray ionization time-of-flight mass spectrometry (ESI-TOFMS). Accurate mass measurements were performed at a mass resolution of 4000 using continuous introduction of a lock mass through a second (electro)sprayer. Similar experiments were carried out using dual-sprayer quadrupole time-of-flight mass spectrometry (ESI-QTOFMS/MS) at a mass resolution of 10 000 with data-dependent MS/MS acquisition; i.e. beyond an intensity threshold for the [M + H](+) ions, MS/MS spectra were automatically acquired at three different collision energies. Elemental compositions were calculated for precursor and product ions and it is shown that the combined information from LC retention behavior, UV spectra, elemental compositions, and accurate mass MS/MS spectra yield a fast impression of the steroids present in the complex mixture. Using a new software tool for structure elucidation of MS/MS spectra, an additional non-steroidal additive was identified as well.  相似文献   

17.
18.
For the detection of anabolic steroid residues in bovine urine, a highly sensitive liquid chromatographic/electrospray ionization tandem mass spectrometric (LC/ESI-MS/MS) method was developed using both positive and negative ionization. For four compounds the ESI mode was not sensitive enough and gas chromatographic/mass spectrometric GC/MS detection was therefore still necessary as a complementary method. The sample clean-up consisted of solid-phase extraction (SPE) on a C(18) column followed by enzymatic hydrolysis and a second solid-phase extraction on a combination of a C(18) and a NH(2) column. After this last SPE clean-up, the eluate was split into two equal aliquots. One aliquot was further purified and after derivatization used for GC/MS analysis. The other aliquot was analyzed with LC/MS/MS in both ESI+ and ESI- modes. The method was validated according to the European Commission Decision 2002/657/EC. Decision limits (CCalpha) were between 0.16 and 1 ng ml(-1) for the compounds detected with the LC/MS/MS method. The developed method is used in routine analysis in our laboratory.  相似文献   

19.
This work describes a novel method for rapid screening of unknown metabolites in urine samples that narrows down the list of potential metabolites. Prior to analysis by liquid chromatography/electrospray ionization mass spectrometry (LC/ESI-MS), urine samples were prepared using solid-phase extraction (SPE). Automatic curve resolution was used for deconvolution of the LC/MS data, followed by peak alignment. Preprocessed data were then used for metabolite pattern recognition using principal component analysis (PCA), parallel factor analysis (PARAFAC), and multilinear partial least squares (N-PLS). This approach enabled the rapid detection of metabolites of citalopram in urine by maximizing the information extracted. The metabolites thus identified were compared with earlier studies on the metabolism of citalopram. In addition, new, unreported metabolites were found and characterized by LC/MS/MS and accurate mass measurements. A combination of data from positive and negative ionization enhanced the identification of metabolites.  相似文献   

20.
An analytical method was developed for the determination in urine of 2 metabolites of diazinon: 6-methyl-2-(1-methylethyl)-4(1H)-pyrimidinone (G-27550) and 2-(1-hydroxy-1-methylethyl)-6-methyl-4(1H)-pyrimidinone (GS-31144). Two of the urine sample preparation procedures presented rely on gas chromatography/mass selective detection (GC/MSD) in the selected ion monitoring mode for determination of G-27550. For fast sample preparation and a limit of quantitation (LOQ) of 1.0 ppb, urine samples were purified by using ENV+ solid-phase extraction (SPE) columns. For analyte confirmation at an LOQ of 0.50 ppb, classical liquid/liquid partitioning was used before further purification in a silica SPE column. An SPE sample preparation procedure and liquid chromatography/electrospray ionization/mass spectrometry/mass spectrometry (LC/ESI/MS/MS) were used for both G-27550 and GS-31144. The limit of detection was 0.01 ng for G-27550 with GC/MSD, and 0.016 ng when LC/ESI/MS/MS was used for both G-27550 and GS-31144. The LOQ was 0.50 ppb for G-27550 when GC/MSD and the partitioning/SPE sample preparation procedure were used, and 1.0 ppb for the SPE only sample preparation procedure. The LOQ was 1.0 ppb for both analytes when LC/ESI/MS/MS was used.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号