首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Occupational exposure to 2,4- and 2,6-toluene diisocyanate (2,4- and 2,6-TDI) was measured during the production of flexible foam. The usefulness of urinalysis of the TDI-derived amines, 2,4- and 2,6-toluenediamine (2,4- and 2,6-TDA), for exposure assessment was compared with air monitoring. Urine samples were collected from 17 employees at two plants. The workers' personal exposure was measured using 1-(2-methoxyphenyl)-piperazine (2MP)-impregnated glass fibre filters for sampling and high-performance liquid chromatography (HPLC) with ultraviolet (UV) and electrochemical (EC) detection for quantification. The limit of detection (LOD) of 2,4- and 2,6-TDI was 0.01 microtg ml(-1) for a 20 microl injection. The precision of sample preparation, expressed as the relative standard deviation (RSD), was 0.6% with UV detection and 0.8% with EC detection at a 2,4-TDI concentration of 0.2 microg ml(-1) (n = 6). For 2,6-TDI, the corresponding RSDs were 0.5% and 0.8%. The urinary 2,4- and 2,6-TDA metabolites were determined after acid hydrolysis as heptafluorobutyric anhydride derivatives by gas chromatography-mass spectrometry. The LOD in urine was 0.35 nmol l(-1) for 2,4-TDA and 0.04 nmol l(-1) for 2,6-TDA. The precision (RSD) of six analyses of human urine spiked to a concentration of 100 nmol l(-1) was 3.7% for 2,4-TDA and 3.6% for 2,6-TDA. There was a trend for linear correlation between urinary TDA concentration and the product of airborne TDI concentration and sampling time. Urinalysis of TDA is proposed as a practical method for assessing personal exposures in workers exposed intermittently to TDI.  相似文献   

2.
A method is described for the determination of urinary 4,4'-methylenedianiline (MDA) by high-performance liquid chromatography (HPLC). MDA was extracted from hydrolyzed urine using C18 solid-phase extraction columns. The extract was analyzed by reversed-phase HPLC with electrochemical detection at a cell potential of 0.8 V. The method was very sensitive (detection limit 2.5 micrograms/l) and quantitation using 4,4'-ethylenedianiline as an internal standard correlated well with results by gas chromatography-mas spectrometry. Run-to-run precision (n = 25) averaged 8.9%. In analysis of more than 160 potentially exposed workers, MDA was detected in less than 20% of the urines and concentrations ranged up to 210 micrograms MDA per g of creatinine.  相似文献   

3.
An HPLC/fluorescence method is described, which enables the sensitive determination of airborne monomeric 4,4′-diphenyl-methane-diisocyanate (MDI). A glass fiber filter coated with 1 mg 1-(2-pyridyl)-piperazine (2PP) is used for sampling. The urea derivative MDI-2PP, which shows a high molecular absorption coefficient and exhibits a sufficient fluorescence response, is extracted from the filter by use of a 90:10 acetonitrile/DMSO mixture. Linear calibration curves were obtained for the indoor range (7.8 ng/mL to 74.7 ng/mL) and the workplace range (27.7 ng/mL to 676.0 ng/mL). A detection limit of 9.0 ng/m3 can be achieved on a total sampling volume of 1000 L. The method is easy to handle and therefore highly suitable for a routine determination of MDI in the atmosphere of workplace areas and living environments.  相似文献   

4.
An HPLC/fluorescence method is described, which enables the sensitive determination of airborne monomeric 4,4′-diphenyl-methane-diisocyanate (MDI). A glass fiber filter coated with 1 mg 1-(2-pyridyl)-piperazine (2PP) is used for sampling. The urea derivative MDI-2PP, which shows a high molecular absorption coefficient and exhibits a sufficient fluorescence response, is extracted from the filter by use of a 90:10 acetonitrile/DMSO mixture. Linear calibration curves were obtained for the indoor range (7.8 ng/mL to 74.7 ng/mL) and the workplace range (27.7 ng/mL to 676.0 ng/mL). A detection limit of 9.0 ng/m3 can be achieved on a total sampling volume of 1000 L. The method is easy to handle and therefore highly suitable for a routine determination of MDI in the atmosphere of workplace areas and living environments. Received: 17 December 1997 / Revised: 2 March 1998 / Accepted: 4 March 1998  相似文献   

5.
A new fluorescent probe, 1,3,5,7-tetramethyl-8-(4'-aminophenyl)-4,4-difluoro-4-bora-3a,4a-diaza-s-indacence (TMABODIPY) has been developed for the determination of trace nitrite in terms of the reaction of nitrite with TMABODIPY first in acidic solution and then in alkaline solution to form diazotate, a stable and highly fluorescent reagent. The method offered the advantage of specificity, sensitivity and simplicity. The linear calibration range for nitrite was 8-300 nmol l-1s with a 3 sigma detection limit of 0.65 nmol l-1. The proposed method has been applied to monitor the trace nitrite in drinking water and vegetable without extraction.  相似文献   

6.
4,4'-Methylenedianiline was determined in human urine by micro liquid chromatography with ultraviolet detection. The combination of a thorough work-up and the high mass sensitivity of micro liquid chromatography gave the method very high sensitivity. Derivatization with pentafluoropropionic anhydride enhanced the resolution of the 4,4'-dimethylenedianiline peak. The detection limit, defined as blank plus three times the standard deviation of the blank, was 2 nmol/l of urine, for 10-microliters injection volumes. The detection limit, defined as three times the noise, was about ten times better. The within- and between-assay coefficients of variation were 4 and 6%, respectively, for samples containing 40 nmol/l. The method was applied for the monitoring of excreted 4,4'-methylenedianiline in urine, during epicutaneous skin hypersensitivity testing (patch testing).  相似文献   

7.
Inulin and p-aminohippuric acid (PAH) clearances are used for the estimation of glomerular filtration rate (GFR) and effective renal plasma flow (ERPF). A simple and rapid high-performance liquid chromatography (HPLC) method with UV detection is described for the simultaneous determination of inulin and PAH in the same chromatogram in the plasma and urine of humans. Plasma and urine samples were hydrolyzed with perchloric acid (0.7%) in boiling water. The mobile phase consisted of 0.01 M potassium dihydrogenphosphate with 0.02 M tetramethylammonium chloride and o-phosphoric acid (pH 3)-acetonitrile (94:6, v/v), pumped at a rate of 1.2 ml min-1 on a C8 reversed-phase column. Tannic acid was used as the internal standard and UV detection at 285 nm was employed. The calibration curves were linear over the concentration range of 12.5-100 mg l-1 for inulin and 6.25-50 mg l-1 for PAH with determination coefficients greater than 0.997. The method is accurate (bias < 13%) and reproducible (intra- and inter-day relative standard deviation less than 11%), with a limit of quantitation of 12.5 mg l-1 and 6.25 mg l-1 for inulin and PAH, respectively. Analytical recoveries from urine and plasma were ranged from 81 to 108% for both compounds. This fully validated method, which allows the simultaneous determination of inulin and PAH clearances, is simple, rapid (total run time < 10 min) and requires only a 200 microliters plasma or urine sample.  相似文献   

8.
A sensitive method for the determination of hyoscine (scopolamine) in urine is described. After concentration and "clean-up" on C18 and CN solid phase extraction columns, hyoscine was quantified by high performance liquid chromatography with coulometric detection (oxidation at +0.9 V). The limit of detection was 5 ng per sample and the precision for 5 mL samples containing 2 ng/mL was 12.3%. The method was applied to urine samples collected from 12 volunteers wearing Scopoderm TTS patches. The mean excretion rate of unmetabolized hyoscine was 0.45 micrograms/h and 87% of the total hyoscine was present as conjugates. Apohyoscine (aposcopolamine) was identified as a urinary metabolite. The significance of this with regard to hyoscine assays is discussed.  相似文献   

9.
A nonaqueous CE system for separation and detection of novel electron-dopable molecular wires based on p-phenylene-bis-4,4'-(1-aryl-2,6-diphenylpyridinium) oligomers is described. The method is based on the coupling of CE separation in pure organic solvent, DMF with 50 mM acetic acid, and UV detection at 338 nm. The system offers a rapid measurement in less than 20 min for two priority nanowires and their impurities. Calibration data confirmed linear response for all compounds of interest in the concentration range 0.1-1.0 mg/mL. A highly stable response was observed for repetitive injections (RSD < or = 2.8%, n = 10).  相似文献   

10.
Four different types of cross-linked polyimides based on 4,4-diphenylmethane diisocyanate (MDI) were prepared by the reaction of different types of conventional poly(amic acid) intermediates with MDI as a cross-linking agent. Subsequently, they were thermally imidized in order to obtain corresponding cross-linked polyimide structure. The results of FTIR-ATR showed that MDI can effectively react with carboxylic acid groups of PAA to form cross-linked polyimide films. TGA, FTIR-ATR and SEM analyses were carried out for characterization of cross-linked polyimide (CPI) films. Moreover, the electrical properties such as dielectric breakdown strength, dielectric constant, I-V characteristics and loss factor of MDI based cross-linked polyimides have been checked. In addition, some physical properties such as water uptake, adhesion, hardness and solubility properties of the films were investigated.The results showed that all CPI films have good insulating properties such as high dielectric breakdown voltage, low loss factor (tan δ), leakage density and excellent physical properties.  相似文献   

11.
4,4′-Methylene diphenyl diisocyanate (MDI) is one of the most important isocyanates in the industrial production of polyurethane and other MDI-based synthetics. Because of its high reactivity, it is known as a sensitizing agent, caused by protein adducts. Analysis of MDI is routinely done by determination of the nonspecific 4,4′-methylenedianiline as a marker for MDI exposure in urine and blood. Since several publications have reported specific adducts of MDI and albumin or hemoglobin, more information about their existence in humans is necessary. Specific adducts of MDI and hemoglobin were only reported in rats after high-dose MDI inhalation. The aim of this investigation was to detect the hemoglobin adduct 5-isopropyl-3-[4-(4-aminobenzyl)phenyl]hydantoin (ABP-Val-Hyd) in human blood for the first time. We found values up to 5.2 ng ABP-Val-Hyd/g globin (16 pmol/g) in blood samples of workers exposed to MDI. Because there was no information available about possible amounts of this specific MDI marker, the analytical method focused on optimal sensitivity and selectivity. Using gas chromatography–high-resolution mass spectrometry with negative chemical ionization, we achieved a detection limit of 0.02 ng ABP-Val-Hyd/g globin (0.062 pmol/g). The robustness of the method was confirmed by relative standard deviations between 3.0 and 9.8 %. Combined with a linear detection range up to 10 ng ABP-Val-Hyd/g globin (31 pmol/g), the enhanced precision parameter demonstrates that the method described is optimized for screening studies of the human population.  相似文献   

12.
This paper describes the validation of a micellar electrokinetic capillary chromatography method for the direct determination of the 3-O-glucuronides of entacapone and its (Z)-isomer, the main urinary metabolites of entacapone in humans. Entacapone is a novel drug which, as a potent inhibitor of catechol-O-methyltransferase (COMT), is used as an adjunct in the standard therapy of Parkinson's disease. The 3-O-glucuronide of another COMT inhibitor, nitecapone, was used as internal standard (I.S.). The validation experiments were performed by using spiked urine samples that were extracted with Sep-Pak C18 cartridges before analysis. Determinations were carried out in a buffer of pH 7.0 containing 25 mM of phosphate, 50 mM of borate and 20 mM of sodium dodecyl sulfate, and by applying 15 kV over a 67 cm (60 cm to the detector) x 75 microns fused-silica capillary. UV detection was at 335 nm. The validity of the method was assessed by investigating the identity of the analytes, selectivity, limit of quantitation, linearity, within-day precision, extraction recovery, between-day precision and accuracy, electroosmotic flow stability and analyte stability. The method proved to be reproducible, sufficiently selective and accurate. Extraction recoveries of the analytes were > 94%. The limit of quantitation (LOQ) was 2 micrograms/ml and the assay was linear in the range 2-150 micrograms/ml with correlation coefficients better than 0.999 for both glucuronides. The repeatability of the method, expressed as the ratio of corrected peak area of the analytes to that of I.S., gave RSD values of < 5% even at the LOQ. Between-day precision (RSD) was < 7.5% for both glucuronides at 7.5 micrograms/ml. Determination of the glucuronide concentrations in urine samples of 34 patients treated with entacapone either orally (200 mg) or intravenously (25 mg) showed the method to be suitable for monitoring the concentrations of the glucuronide of entacapone after both oral and intravenous administration and those of the glucuronide of its (Z)-isomer after oral administration. The limited long term stability of the system requires, however, frequent recalibration in applications involving long sample series.  相似文献   

13.
B Gammelgaard  O J?ns  B Nielsen 《The Analyst》1992,117(3):637-640
A method for the simultaneous determination of chromium(iii) and chromium(vi) in a flow system based on chemiluminescence was developed. A Dionex cation-exchange guard column was used to separate chromium(iii) from chromium(vi), and chromium(vi) was reduced by potassium sulfite, whereupon both species were detected by use of the luminol-hydrogen peroxide chemiluminescence system. Linear calibration for both species was established over the concentration range 1-1000 micrograms l-1. The precision at the 20 micrograms l-1 level was 3.5% for chromium(iii) and 3.3% for chromium(vi), respectively. The detection limit was 0.5 micrograms l-1 for both species. Data were in agreement with Zeeman-effect background corrected atomic absorption spectrometry measurements.  相似文献   

14.
Analysis of 4,4'-methylenebis(2-cholroaniline) (MOCA) or its metabolites in urine has been considered as the appropriate method to assess MOCA exposures through inhalation and skin absorption. MOCA and its metabolite, N-acetyl 4,4'-methylenebis(2-chloroaniline) (acetyl-MOCA), are analyzed using methods either limited by sensitivity or sample preparation. Therefore, a solid-phase extraction (SPE) and liquid chromatography/tandem mass spectrometry (LC/MS/MS) method was developed to simultaneously analyze MOCA and acetyl-MOCA in urine to serve as biomarkers for MOCA exposure. Protein was precipitated by using acetonitrile, and SPE were applied to clean up samples to eliminate the matrix effect and to improve the recovery. The limit of quantitation of this method was at 1.0 ng/mL for MOCA and 0.03 ng/mL for acetyl-MOCA (signal-to-noise (S/N) ratio = 10). Urinary MOCA and acetyl-MOCA levels in MOCA-exposed workers were analyzed and quantitated to be 191.9 +/- 373.2 (mean +/- standard deviation (SD)) and 11.79 +/- 23.8 ng/mL (N = 54) with the median values 38.6 and 1.8 ng/mL, respectively. MOCA concentrations are significantly correlated with their corresponding acetyl-MOCA levels in urine (Spearman correlation coefficient r = 0.916, p < 0.001). These results show that this method has been successfully developed and provides high-throughput potential to analyze MOCA and acetyl-MOCA to serve as exposure biomarkers for future study of the potential health effects associated with MOCA exposures.  相似文献   

15.
S E Fowles  D M Pierce 《The Analyst》1989,114(11):1373-1375
A rapid, sensitive and reliable reversed-phase high-performance liquid chromatographic (HPLC) method with UV detection has been developed for the assay of a novel anti-herpes agent, 9-(4-hydroxy-3-hydroxymethylbut-1-yl)guanine (BRL-39123), in human plasma and urine. The drug and the internal standard, the structural analogue BRL-42377, were extracted from the biological matrix by adsorption on a cation-exchange column and were subsequently eluted under alkaline conditions prior to HPLC. The method is reproducible, with coefficients of variation of ca. 5%, and linear from 0.1 to at least 30 micrograms ml-1 in plasma and from 50 to at least 2000 micrograms ml-1 in urine. The method has been used extensively to measure BRL-39123 in plasma and urine samples generated during clinical studies and is adequate for defining pharmacokinetics at projected therapeutic doses.  相似文献   

16.
K Jedrzejczak  V S Gaind 《The Analyst》1992,117(9):1417-1420
A highly sensitive and specific gas chromatographic-mass spectrometric (GC-MS) assay for the determination of 4,4'-methylenebis(2-chloroaniline) (MBOCA) in urine is reported. It is based on the solvent extraction of the hydrolysed MBOCA conjugates, together with deuterium-labelled benzidine-d8 added as an internal standard, and a two-phase derivatization procedure involving use of pentafluoropropionic anhydride in the presence of ammonia as the phase-transfer catalyst. The reaction is complete within 2 min at room temperature. The pentafluoropropyl derivatives are determined by use of capillary column GC-MS with selected-ion monitoring in the negative ion chemical ionization mode. The lower limit of detection for MBOCA was 1 microgram dm-3 and the calibration graph showed linearity between 10 and 250 micrograms dm-3. The recovery of the analyte added to pooled urine was above 86%. Thirty urine specimens from workers employed in a polyurethane-producing plant were analysed for MBOCA by this method.  相似文献   

17.
Using a common spectrofluorometer to measure the intensity of Rayleigh light-scattering (RLS), a method for determination of nucleic acids has been developed. At pH 10.24 and ionic strength 0.01 mol l-1 (NaCl), the Rayleigh light-scattering of the tetra-(N-hexadecylpyridiniumyl) porphyrin (TC16PyP) is greatly enhanced by nucleic acids in the presence of cetyltrimethylammonium bromide (CTMAB), with the scattering peak located at 311.8 nm. The enhanced RLS intensity is in proportion to the concentration of calf thymus DNA (ctDNA) in the range 0.2-6.0 microg ml-1 and to that of fish sperm DNA (fsDNA) in the range 0.05-3.0microg ml-1. The limits of detection are 0.016 microg ml-1 for calf thymus DNA and 0.023 microg ml-1 for fish sperm DNA when the concentration of TPP was chosen 2.0 x 10(-6) mol l-1. Four synthetic samples were determined satisfactorily.  相似文献   

18.
A sensitive, accurate and precise liquid chromatography/tandem mass spectrometry (LC/MS(2)) method was developed for the quantification of salmeterol in the urine of horses. The method consists of a liquid-liquid extraction with tert-butylmethyl ether and isopropanol at pH 12 after enzymatic hydrolysis. The extracts are analysed using an LC/MS system equipped with an electrospray ionisation (ESI) probe. Method validation showed excellent linearity, specificity, accuracy, precision and intra-laboratory repeatability and reproducibility. The limit of quantitative detection was 0.25 ng/mL and the limit of detection was 0.125 ng/mL. The excretion profile was determined after administration of 500 microg salmeterol (Serevent) to four standard-bred mares via a metered dose inhaler (MDI) with an Equinehaler adapter. Salmeterol was detected from 1 h until 12 h post-administration. Maximum urinary concentrations varied between 2.3 and 14.9 ng/mL.  相似文献   

19.
Li Z  Zhu Z  Jan T  Pan J 《The Analyst》1999,124(8):1227-1231
A new very sensitive and selective chromogenic reagent, meso-tetra-(3,5-dibromo-4-hydroxylphenyl)porphyrin [T(DBHP)P], was synthesized and studied for the determination of trace lead in detail. In 0.10 mol l-1 NaOH medium, lead reacts with T(DBHP)P to form a 1:2 yellow complex, which gives a maximum absorption at 479 nm; 0-0.48 microgram ml-1 Pb(II) obeyed Beer's law. The molar absorptivity of the complex and Sandell's sensitivity are 2.5 x 10(5) 1 mol-1 cm-1 and 0.000812 microgram cm-2, respectively. Second-derivative spectrophotometry is better than conventional spectrophotometry in sensitivity and selectivity, and its limit of quantification, limit of detection and relative standard deviation are 0.70 ng ml-1, 0.21 ng ml-1 and 1.0%, respectively. Ca (3250-fold), Mg (2000-fold), Sr (1000-fold), Ba (750-fold), Al (1000-fold), Bi (500-fold), Fe (2000-fold), Co (750-fold), Ni (1000-fold), Cu (750-fold), Zn (1250-fold), Cd (2500-fold) and Ag (550-fold) do not interfere with the determination of lead. The chromogenic system is remarkably superior to other reagents, especially porphyrin compounds. The influence caused by oxygen in air or in solution can be easily eliminated by adding Na2SO3. The reaction is very stable, the stability constant of the complex being 1.2 x 10(45). The chromogenic reaction is completed within 1 min at room temperature when 8-hydroxylquinoline is used as catalyst. The proposed method has been applied to the direct determination of trace lead in clinical samples. The accuracy and precision are both very satisfactory.  相似文献   

20.
The assay of malondialdehyde (MDA) is widely used in clinical chemistry laboratories to investigate lipid peroxidation in oxidative pathologies. In the present work, the thiobarbituric acid (TBA) reaction was carried out on plasma, human erythrocytes and fibroblasts. The reagents used were those of the fluorimetry MDA kit manufactured by Sobioda. We have defined the application of this kit to high-performance liquid chromatography. This adaptation satisfied the criteria of good analytical practice. The detection limit was 2.5 pmol per injection. The retention time of the MDA-TBA2 peak (4.96 +/- 0.07 min) led to excellent resolution of the complex. The within-assay (6-12%) and between-assay (11-12%) precisions were satisfactory. The analytical recovery of MDA after spiking samples of human plasma with tetraethoxypropane standards varied from 70 to 100%. The mean lipoperoxide concentration determined in 32 healthy adults (20-40 years) was 1.04 +/- 0.23 mumol l-1 in plasma. Applied to the erythrocytes of fifteen laboratory workers, the method furnished physiological values of 0.59 +/- 0.21 mumol l-1. Concentrations were significantly higher in chronic renal dialysis patients (4.15 +/- 2.35 mumol l-1. The MDA content of fibroblasts cultured in standard medium was 0.38 +/- 0.04 mumol per g of protein and increased (5.78 +/- 1.38 mumol per g of protein) if the cells were grown in an iron-enriched medium. This accurate high-performance liquid chromatographic method for detection of MDA is the first one which can be applied to plasma, red blood cells and cultured cells. This technique will prevent false positives and should make inter-laboratory comparisons possible.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号