共查询到20条相似文献,搜索用时 0 毫秒
1.
A new solid state fluoride ion selective electrode composed of 70% Ag2S, 10% Cu2S and 20% CaF2 has been developed. An analytically useful potential change occurred, from 1 × 10−6 to 1 × 10−1 M fluoride ion. The slope of the linear portion (1 × 10−1-1 × 10−5 M) was about 26 ± 2 mV/10-fold concentration changes in fluoride. It was found that pH change between 1 and 8 had no effect on the potential of the electrode. There was no interference of most common cations such as K+, Na+, Ca2+ and Mg2+ and anions such as Cl−, NO3−, SO42− and PO43−. The lifetime of the electrode was more than 2 years, when used at least 4-5 times a day, and the response time was about 60 s.The measurements were made at constant ionic strength (0.1 M NaNO3) and at room temperature. This electrode has been used for the determination of fluoride ion in Ankara city tap water and in bottled spring water using standard addition method. The validation of the electrode has been made with a commercial fluoride ion selective electrode (Orion) and high consistency was obtained. 相似文献
2.
An electrode for glucose has been prepared by using an iodide selective electrode with the glucose oxidase enzyme. The iodide selective electrode used was prepared from 10% TDMAI and PVC according our previous study. The enzyme was immobilized on the iodide electrode by holding it at pH 7 phosphate buffer for 10 min at room temperature. The H2O2 formed from the reaction of glucose was determined from the decrease of iodide concentration that was present in the reaction cell. The iodide concentration was followed from the change of potential of iodide selective electrode. The potential change was linear in the 4×10−4 to 4×10−3 M glucose concentration (75-650 mg glucose/100ml blood) range. The slope of the linear portion was about 79 mV per decade change in glucose concentration. Glucose contents of some blood samples were determined with the new electrode and consistency was obtained with a colorimetric method. The effects of pH, iodide concentration, the amount of enzyme immobilized and the operating temperature were studied. No interference of ascorbic acid, uric acid, iron(III) and Cu(II) was observed. Since the iodide electrode used was not an AgI-Ag2S electrode, there was no interference of common ions such as chloride present in biological fluids. The slope of the electrode did not change for about 65 days when used 3 times a day. 相似文献
3.
A highly selective and sensitive phosphate sensor has been fabricated by constructing a crystal disk consisting of variable mixtures of aluminium powder (Al), aluminium phosphate (AlPO4) and powdered copper (Cu). The membrane sensor exhibits linear potential response in the concentration range of 1.0 × 10−1 to 1.0 × 10−6 mol L−1. The proposed sensor also exhibits a fast response time of <60 s. Its detection limit is lower than 1.0 × 10−6 mol L−1. The electrode has a long lifetime and can be stored in air when not in use. The selectivity of the sensor with respect to other common ions is excellent. 相似文献
4.
5.
涂碳型PVC膜培氟沙星选择电极的研制 总被引:2,自引:0,他引:2
报道一种以盐酸培氟沙星与溴汞酸盐生成的分子缔合物为电活性物质的新型涂碳PVC膜培氟沙星选择电极。在pH 1 .5~ 4.5范围内 ,电极对培氟沙星的Nernst响应范围为 1 .0× 1 0 - 2 ~ 5 .0× 1 0 - 5mol/L ,检测限为 4.2× 1 0 - 6mol/L。方法的平均回收率为 98.5 % ,RSD为 1 .0 % 相似文献
6.
7.
A new selenite ion selective electrode using 4,6-dibromopiaselenole as active material, PVC as membrane matrix and dibutyl phthalate as plasticizer has been developed. An analytically useful potential change occurs from about 10(-6)-10(-1)M Se(IV), and the slope of the linear portion is -23.6 mV/10-fold change in Se(IV) concentration at a temperature of 21 degrees . The electrode shows fairly good selectivity for selenite ion over other anions and has been used for the successful determination of total selenium in human hair. 相似文献
8.
The influence of various factors such as solubility, the oxidation of the membrane, and the contamination of the solution, on the experimental values of the selectivity coefficients of solid state sulphide ion selective electrodes is discussed. A new method for the evaluation of very small selectivity coefficients, based on the addition of reagents forming complexes or insoluble salts with the main ion, is proposed. By means of this method, selectivity coefficients for silver, copper, cadmium and lead ion selective electrodes have been determined, which are in far better agreement with thermodynamic values than those described in the literature. 相似文献
9.
A new selenite ion selective electrode using solid salts of Ag(2)Se and Cu(2)S has been developed. Detailed information is provided concerning the composition, working pH and conditioning of the electrode. The change of potential with concentration is found to be linear in the range of 10(-5)-10(-2) M, the slope of the linear portion is 28 mV/10-fold change in selenite concentration. The effect of other ions on selenite response is evaluated and selenium content of anodic slime is determined. 相似文献
10.
本文报道了茜素S电极的研制和应用。比较了季铵盐、季鏻盐、碱性染料和邻二氮菲金属配合盐作为活性物质、各种介体溶剂以及活性物质在膜相中的含量对电极性能的影响。以三辛基甲基氯化铵制成的PVC膜型电极对茜素S在2×10~(-4)~5×10~(-7)M浓度范围内呈Nernstian响应,检测下限为2×10~(-7)M。测定了一些阴离子的选择系数,ClO_4~-,CNS~-,I~-以及能与茜素S配合的金属离子有明显干扰。报道了以茜素S电极为指示电极,用EDTA和茜素S为滴定剂滴定钪和稀土的情况。以茜素8电位滴定钪及钴-钐合金中的钐,都获得良好的结果。 相似文献
11.
12.
应用循环伏安法和线性扫描伏安法研究了双氯芬酸钠在多壁碳纳米管修饰电极上的电化学行为,建立了一种直接测定双氯芬酸钠的电分析方法.在0.1 mol/L HClO4溶液中,双氯芬酸钠的氧化峰电位在0.38 V(vs Ag/AgCl),峰电流与浓度在2.0×10-7 mol/L~7.0 × 10-6 mol/L范围内呈线性关系,开路富集3 min后检出限为9.0×10-8 mol/L.5×10-6 mol/L双氯芬酸钠溶液平行测定10次的相对标准偏差(RSD)为4.5%.已用于扶他林片剂中双氯芬酸钠的测定. 相似文献
13.
Tahereh PoursaberiMorteza Hosseini Massoud TaghizadehHooshang Pirelahi Mojtaba ShamsipurMohammad Reza Ganjali 《Microchemical Journal》2002,72(1):77-83
A highly selective electrode for iodide ion based on a thiopyrilium derivative as an excellent ionophore is described. At pH 5.5-8.0, the electrode responds to iodide ion in a linear range from 1.0×10−1 to 8.0×10−7 M with a slope of 60.2 mV per decade, and a detection limit of 2.0×10−7 M. Selectivity coefficients determined with the match potential method (MPM) indicate that the interference from inorganic and organic anions is very small. The proposed sensor shows a fast response time of approximately 15 s. It was applied as an indicator electrode in titration of iodide with Ag+. 相似文献
14.
15.
The response characteristics of the solid state cyanide ion selective electrode towards some benzylnitriles are investigated. In 10M KOH solution, the electrode exhibits nearly Nernstian response over the concentration range of 10–2 to 10–4
M of various substituted benzylnitriles with an anionic slope of 53–59 mV/concentration decade. The response time varies from 10 to 20 min depending on both the nature of the substituent group and the concentration of the nitrile compound. Direct potentiometric measurement of some nitrile compounds at the concentration level of 0.01 to 1 mg/ml shows an average recovery of 98.2% and a mean standard deviation of 2.3%. Many nitrogen functional groups do not interfere. 相似文献
16.
17.
18.
The thermodynamic pressure parameter has been thoroughly used with mastership by Gérard Demazeau throughout his rich career in solid state chemistry and materials sciences and more recently in biosciences. After a review of such works, focus is made in this topical article on his contribution together with his team in the field of hard materials based on light elements B, C, N with a proposition of a new ultra-hard carbon nitride C2N on one hand and on the structural transformations under high pressures of perovskite into postperovskite with a change of dimensionality from 3D to 2D and related oxides, regarding the arrangement of octahedra, on the other hand. Investigation and concepts first arising from experimental observables are shown to be aided and accelerated via first principles calculations of energy and energy-related quantities. 相似文献
19.
20.
以Ag/AgCl丝为基体依次外涂含0.1 mol/L KCl的琼脂凝胶膜及含四苯硼-司帕沙星缔合物的PVC膜,制备了一种双涂膜司帕沙星选择电极。采用正交设计法,研究了离子缔合物的种类、活性物在膜中的浓度及增塑剂三因素对电极的影响。电极的线性范围为1.0×10-5~1.0×10-3mol/L,检出限为2.4×10-6mol/L,斜率为28.8 mV/decade(16℃),可直接用于司帕沙星片剂的含量测定,回收率为99.6%~101.1%,结果与文献法一致。 相似文献